Loading...
12-86 4OF7-0841b IN i 11 G E IC 0 Q 00 N 0 N i:3 I N 0 a- a Q w 11"01 zl w U I 1 2 3 4 1 5 6 7 8 9 10 11 12 13 14 15 16 1 A A.1 B B.8 C D D.8 E E.6 F.2 F.3 G.2 G.8 H.1 H.2 H.8 I.5 I.7 I.3 J.2 J.6 I I I I I I I I I II I II II I I S I I 1 A/C UNIT 4A/ AUXILIARY RAIN PAN FC -A5 RESEAL 1/2" CW RESEAL A 202 - - A -203 - -I - ST -A2 , - - -�- - -�- - - I - -�- -- -- -�- - - 1.1 UNDER FL SLAB CORRIDOR 9 I 3/4" H.B. I 3 4ETS( PD PD E WL S' RWL (260 SF) ' DN. 1CLG. ' 47 SAN STACK Rb0M� /4 RWL P 467 SF) lA I S 3" N� DN UP ST -Al DN e5 STA K 1 1 0 FICECD STACK 1 1 2" W DN' A/C UNIT 1 , I i I CW I FC -A6 CD I CD 5 3 4" AU 2" D. DN e , 4" RWL WL I 1 / DRAIN PAN 2 112" CW DN CW I II (1925 SF) 2 t " S I 1 1/ e 1 4 SAN STACK e 1 1�4 "VENT WIL ' 3"VENT STACK ' e 6"RWL I 1 -3 2"CD STACK 1 1 /4 "CW DN CW ' 4 "VENT UP + +16' -o I RAMP UP +18' -0° A -205 RA P UP + BELOW FLR. i ORRIDOR II (3.1 I CD I A -206 6"RAINWATER DN. 1 1 SERVI E CORRIDOR TO 15T I -6 - - - -- 2 1/1' I I CLG. I ' - - - -- - - - - - - DN - - - - - - - ice- - - - - -- 4 6"VENT 1P_/ 6"SAN FROM ABOVE , I ' 4"SAN STACK S I I I 6" RWL RWL 6050SF) jj 3"VENT STACK I I I ST -A4 5 - - - - - --E�3-- - - 1 1 1/4" \ 2j I 3 "vENr STACII S CD I ' 14 3/41(2) A/C UNIT "CD ACK 1 I 8 2 I Cr GW & VENT GW ' AUXZ AN DRAINS CD 4 "SAN STACKI I I I 1" EF LINE AND 2 f 1 1/4" EWH PAN DRAINS I I II 1 \--3/4 A/C UNIT ST -A3 AUX., PAN DRAIN WL "U 3 "(275SF)UP WL ABV. CLG. 4 15 5SF) 4"(1800SF)DN 4 i i , A -207 t I RESTAURANT -TD06 ENANT -D01 ' 8A 2"CD STACK 1 2" EL TANK ' - - - - - - - - - - - - - - - - - - - - - VENT , J-3/4! HB (:: 6 1 UP DN I 1 I CD s S CD GW CW ABOVE CEIL " 1 �� - I , 4 ' 2"CD STACK ' - - - - - 3 , RWL (6. Y�'RELJEF LINE & 1 1/ " -4 SAN STACK - - - " - - - 1 - ` - - 1 - - - - - - F - , R 1425 SF 12 .W.H. PAN DRAIN 3�NT STACK 4 I ABOVE 2ND. I 1 4 �, 1 1 '7 1 1 GW FL CLG. I I ° 1 2 "CD ACK , i 1 6"GW AC W 1A 8L 66 5L SF) 9B 4 "GAS, CA 4! RE-SEAL 7 12 40SF e , I I ABV. CLG. TI w 1 W - - - - - - - - -� 3 cg ' ' ' ' , ' _ ' 3"C ' ROOM TO 3RD FL RISE FROM 1ST FL WATER HEATER (EWH -2) W/ PUM I 1 2" HW & C TO P 8A , CORRID R AS IER AMC" REQUIREM 1 1-47C1 1 , 2" ESCALATOR RA L OP ABOVE CEIL W 1 4 W L OP OVE CEIL � I I I RWL RWL ' (171 ' (4025 S) 9 ' , FOR DETAILED DESIGN OF THIS / I 1 8" RWL I AREA, SEE ENLARGED PLUMBING 1 , RWL--\ (9880 SF) PLAN ON SHEET A -P4.01 g- - - - - - - - - - - - - 4, - - - - - - - - - -- - - , I , 1 1 1 I I C840 1 1 (2 10 SF) / , I / I , RWL 4" t 1550 Z F UP 1 KEY PLAN D A B c 17 1 18 1 1 �Tr � A 7,\'T 1. ALL DRAINAGE PIPING 4" AND LARGER SHALL 11 1L U,%//11 >-uu u, iL u BE SLOPED AT 118" PER FOOT MINIMUM. 2. ALL DRAINAGE PIPING 3" AND SMALLER SHALL ��OUP BE SLOPED AT 1/4" PER FOOT MINIMUM M 3. ® INDICATES ELECT. RM., TEL RM. NATIONAL CITY CENTEI AND /OR ELEVATOR EQUIP-T. RM. BELOW. P �, BOX 7033 AVOID INSTALLING PIPING BELOW SECOND FLOOR IN THESE AREAS. INDIANAPOLIS, ICI 46207 (317) 636 -1600 N.6 0 0.3 0.6 0.9 1 I I I " N. TO WH. n III I L K i THIS COA RAS COMPANY Y 1111 Lincoln Road Mail Suite 510 Miami Beach, FL. 33139 (305) 532 -0433 I I� I A -232 I I I C9 I I aeOVE , CORRIDOR I CLG. I I I I o I I w - I _ - T I I E - 8 CD Cn __j I I i I I I I I I I H o L_ --1 UE/ 1 .5 L. L. M.2 M.5 M.6 N.1 0 0.3 0.6 0.9 P.2 --J � w 13 1193 )DN. N o (500 SF) S _ _ 9.7 " I A- 6 , - - - - - - - - - - - - NLO A- 18 1 31 23 +20' -0 3 "AD I I I - - - I - - , I EL -A5 P - - - I (6DSF) I - I - - I - I - - I - - - - \ - ' wL - I PLANTER I I t I 10.1 - l/ / C770 AD i p I B,L,W�{ ' ° T� A- 30 � PLANTER �, SF I 0 A-2 0 rLIC. ELEV. SF) 3 "AD I I I 4 CW LOOP BE OW THIRD , < ) 18 9" RAMP CORR I \ I \ FLOOR LEVEL, OR CO NIT. / / /f A -22 I I 0 ® EL -A6 UP VES E' SEE SHED B -�3.0 / 1 / TENANT )1B H 2�- r / / I A -221 1 DN 4. 0 0 _ - DRAIN Cr m rl T T -EO1/, CD WL RWL L RW " CW 11 14 (11180 SF) L 1 ) A7 1 �/ ,4 ®1/ I 10 , V C" 1 I 1 I 1 a z _/ (770 SF� - ' T -E -T- . ' TVENT STA K ST- ' 7 PLANTER / D P 3 � •� .47 4! SAN STAC 4801 SF 2"CID STACK 4" _ 1 1 10 ° 1 I\ 1 GW 4 UCN A -225 I I L TENANT -E02 (13so�j/ , YO ' 1 CD -224 I � / , , CW CD �' ,AD ' ' ' \ 3"VENT S GW I e ' 13 (65 F) 1 I \ , RWL , e e ^ / � 11, 12 ' -I 1 1 I I 1 11 4" AD 4 250 SF 1�8"RWL TENANT -'EO3 11 11 4 01 4 )� RW ,� , - - -- - - - -- - - -- - -- -�" (el 66 S l� p S�) ° '� � S (7350 SF) 109(1 SF � A -2 1 1 / \ / / ( Y TENAN - 04 A 2ND 1 \ I \ I *�6 RW // / , , CLG. �� / A42 ®1 TENANT- 05 0 s6 12.5 I 17', , I I I I I � � /� I I \ I I I I I ° ' , WL 4" R�VL I ° ®1/ I 18 (2740 SF 1 �C590 1 ) SF /5-011--f /FT / (1170 SF) / 6 "RWL 580 G.4 G.7 (4145 SF) L / F.7 / / /H.t` 17 II I ( I�D (4 ApD / / H.5 I I I I I G 3 / / H.7 _\ - 13.� G.6 1 ,I ' \\ ° I.2 14.1 ,� I \ I.9 / 1 I BLDG. A SEC ND FLO R PLU BI PLAN \ \ \ , ,� A-3 ' SCALE.1 /16 -1 -0 \ _/ X�\ \ 1 2 3 4 5 6 7 8 0 10 11 _ TYP. + - 90SF) 1 - L - - RAP N - - - - - - 10'4 I / - - 5960 S.W. 57TH AVE. " MP uP 2 z WL 1 i I I 1 1 I i \\ �� MIAMI, FLORIDA 33143 AD E� 24 (OSF) , , 1 1�' 3' ,, - � � \ � TEL (305) 666 -5474 WL FAX (305) 666 -4994 _ _ _ AA 0002416 I I A -233 I \ L EB 0002354 CORRIDOR 3"P R r( A� WL A -232 CORRIDOR \ DRAIN , ,I' \ \ MARIO H. GUTIERREZ, P.E. - ' COR IDOR - - ' - _ N_ - _ \ - - 1 ' ` 1 \ FL. MECHANICAL ENGINEER ITt17Tl I 1rt?I �} REG. NO. 0019687 � ITC IT I I D 1 4 I (39 ) 1s IIIIIIIIII IIIIIIIIIIIIIII ' z C T 1 �� ' IIII ASE 1111111 IIII ' ' " � , � 4 "CW L�J�P BLOW TH�R IIII I I I I (IIII ' I FL00 LEVEL.,1 FOR CO \ \ SEE H ET C- P3.02 IIII III I I. (1�SF) l l l l l l l l l I I I l r l� l /•• cw �. D �1= , �/ [-(6190SF) 6"RWL \ UP I " GW 6.� _ _ �, r, . (6860SF) DN - I �4 SAN S - 1 - 5 - 2" CD STAG CD CD A -235 i �3"VENT 15 2 "CD� 3• S 3. (700 SF) YyH \ 14 TENANT -F01 SAN 1 ' \ _ I I \ _ ISSUE DATE 1 3" AD I \ ®1/8" Fr 4260 SF *29L 550 SF) ( ) ( 70 REVISION DATE \�3" AD I " I ` -O� 08 -07 -96 ' - PRICING DOC. - - - - - - - - - - - - IN I I 1 _ 12 -10 -96 ° TENANT -F03 , , ❑ 02 -12 -97 I 1 O sF) A04-14-97 o - ° 3" ®1/4" FT 4" 141OSF UP wL ' I - U 06 -18 -97 o i (775 SF� 4 "�2765SF� DN 26 I I - �� - \ _ w . ---) o ' ' 6" 3000SF UP RWL I ' 1 - U ° / I 6"�3555SF3 DN. 27 3"RWL WL _ ° ° e� 1 - Q_ I° 3°AD } - - �v - -775 S - - - - - - 3"AD�- - \-- Q CADD FILE NAME AD � llr555 SF) / AP302 -RT - _ I I � IG DRAWING TITLE GW4 BLDG A 2nd FLOOR PLAN , Wl GW2 GW3 5 Zr AD I SHEET NUMBER UP TO AD (255 SF) ABV. CLG. CONT'D SHEET B -P3.02 A -P3.02 `� 12 13 14 15 16 17 18 OF