Loading...
12-86 4OF7-070M L 10 i I H G F 10 IC C It ki 11 L IMI A-;E L VA e e PA 1 2 I 3 I 4 I 5 I 6 FOOTING SOFFIT BEAMS: SIZE REINFORCEMENT COLD FORMED METALS: CONCRETE SHALL BE CLEAN, FREE OF LAITANCE AND INTENTIONALLY �• a � e B) SUBMIT SIGNED AND SEALED CALCULATIONS BY FLORIDA P.E. AS WELL AS SIGNED AND SEALED PLANS AND CONNECTION DETAILS. DESIGN FOR WIND LOADS AS PER ANSI A58.1 (1982). INCLUDE PLACING DRAWINGS 7. STRUCTURAL STEEL: FOR FRAMING MEMBERS SHOWING SIZE AND GAGE DESIGNATIONS, NUMBERS, A) CONFORMING TO ASTM A -36. STEEL TUBE COLUMNS CONFORMING TYPE, LOCATION AND SPACING. INDICATED SUPPLEMENTAL STRAPPING, BRACING, TO ASTM A -500, GRADE B. • 1 B) 1 � 1 1 INSTALLATION. USING ASTM A -325 AND ASTM A -490 BOLTS'. C) ALL EXPOSED STEEL MEMBERS (INCLUDING INSERTS AND CONNECTORS) TO BE HOT- DIPPED GALVANIZED. ALL OTHERS TO HAVE A MINIMUM 1.5 MIL OF RUST - INHIBITING PAINT. 16. PRICING QUANTITIES: TOUCH -UP AS REQUIRED AFTER ERECTION. D) FABRICATION AND- ERECTION ACCORDING TO THE LATEST AISC FOR PRICING PURPOSES, ASSUME (AS MINIMUN) THE FOLLOWING QUANTITIES SPECIFICATIONS. FOR UNSCHEDULED STRUCTURAL ELEMENTS: E) ALL WELDING TO BE PERFORMED BY CERTIFIED WELDERS IN COMPLIANCE WITH AWS D- 1.1 -77. ELECTRODES TO COMPLY 1.) CONCRETE BEAMS: WITH ASTM A -233 OR A -316 STORED AS PER AWS REQUIREMENTS. STORED AS PER AWS REQUIREMENTS. A. SOFFIT BEAMS : Mu = 450 FTK, Vu = 175K "C TOP STEEL: 4 #9 CONT. W/5 #10 BARS. SHEAR FRICTION : 4 #10 BARS 8. MASONRY WALLS: A) MASONRY SHOWN IS NON- BEARING AND MUST BE ERECTED AFTER B. "WET" BEAMS THE STRUCTURE TOP STEEL: 6 #10 BOTTOM ABOVE BEEN ERECTED AND ANTICIPATED DEFLECTION HAS OCCURRED. "r' BARS: 2 #6 ® 1/3 PTS FOR BM'S OVER 30" DEEP. B) MORTAR MUST CONFORM WITH ASTM C -270, TYPE M (2,500 P.S.I.). F'M OF BLOCK 2.) CONCRETE COLUMNS: �- 1 1 PROVIDE STANDARD DUROWALL REINFORCING EVERY OTHER COURSE VERTICAL REINFORCING: 2.5% OF GROSS AREA. AND LAP AROUND CORNERS AND WALL INTERSECTIONS WITH TIES: #3® LEAST COLUMN DIMENSION. PREFABRICATED "L" AND "T" CORNER SECTIONS. D) LAP ALL VERTICAL BARS 48 BAR DIAMETERS. FILL SPECIFIED 3.) CONCRETE WALLS: CELLS WITH 3,000 P.S.I. CONCRETE PUMP MIX CONSOLIDATED 1 : 1 1 1 ••C' 1 •.0 1 ERECTED HIGHER AT THAT POINT). PROVIDE CLEAN -OUT HORIZONTAL REINFORCING: $4 ®12" EACH FACE.. HOLES AT BOTTOM OF EACH REINFORCED CELLNTS AS REQUIRED. ALL SHOP DRAWINGS, PRIOR TO BEING SUBMITTED TO OUR THESE VALUE ARE NOT TO BE USED FOR CONSTRUCTION PURPOSES. OFFICE, MUST BE STAMPED BY BOTH THE ARCHITECT AND THE G.C. AS EVIDENCE OF THEIR PREVIOUS REVIEW. UNAUTHORIZED DUPLICATION OF OUR PLANS TO BE PRESENTED AS PART OF THE SUBMITTAL, IS STRICTLY 17. • 1 - ' 1 1 A. STAIR BEAMS AND ELEVATOR BEAMS SHALL BE DESIGNATED "STB" AND "ELB" RESPECTIVELY, (SEE SECTION). 9. SOIL COMPACTION: FILL AND BACKFILL UNDER CONCRETE SLABS ON GRADE MUST BE B. "STY" AND "ELY" SHALL BE 8"X24 WITH 2 #8 BOTTOM COMPACTED TO A MINIMUM OF 95% OF THE MAXIMUM DENSITY AT AND 2 #6 TOP & CLOSED TIES #3 ®10" O.C. OPTIMUM MOISTURE AS DETERMINED BY THE MODIFIED PROCTOR TEST (ASTM D -1557, METHOD D) LINTEL • 1 • 1 � • 1 1 1 • • C : • . C� A. LINTEL BEAMS MAY BE PRECAST OR CAST -IN -PLACE CONCRETE. 8 -MIL VISQUEEN VAPOR BARRIER AND IN A "CHECKERBOARD" M=10'4'x`10'4'x2'-6 SEQUENCE, EACH SEGMENT OF WHICH IS NOT TO EXCEED A . C� : � MAXIMUM AREA OF 625 SQ. FT., OR 30 LINEAR FEET IN ANY DIRECTION AND AT ALL COLUMN LINES. PREMOLDED METAL C. FOR CAST -IN -PLACE CONCRETE LINTELS USE 8"X8" WITH 2 #5 BOTTOM. / • 0'-_6_'x2'- 1 KEYED JOINTS (FULL SLAB THICKNESS) MAY ALSO BE USED. CUT WIRE FABRIC AT ALL JOINTS. D. LINTELS CONNECTING INTO MASONRY WALL HAVE 8" MIN. BEARING. 11. APPROVALS: A) I ON W3 ONE PRINT AND ONE SEPIA OF EACH. CONTRACTOR WILL ISSUE ==1 PRINTS AS REQUIRED. ALL SHOP DRAWINGS, PRIOR TO BEING 1 - 1 M- THE ARCHITECT AND THE G.C. AS EVIDENCE OF THEIR PREVIOUS REVIEW. UNAUTHORIZED DUPLICATION OF OUR PLANS TO BE 1.1 1 . 1 1 `� PRESENTED AS PART OF THE SUBMITTAL, IS STRICTLY ROUGHENED FORBIDDEN. 2 #5 TOP & BOT. SURFACE B) SUBMIT LABORATORY REPORTS FOR ITEMS 4 AND 7. DOWELS. 12. COORDINATION: COORDINATE ALL DIMENSIONS, ELEVATIONS, OPENINGS AND 1 1 1 DETAILS WITH ARCHITECTURAL, ELECTRICAL AND MECHANICAL WALL OR COL. =12'-0"x12'-0"x3$-111 OFFICE. IN CASE OF CONFLICTS OR DISCREPANCIES, CONTRACTOR MUST ASSUME COSTLIER SOLUTION DURING BIDDING �1 1 1 1 . .._ LINTEL DETAIL ; ARCHITECT. 13. SHORING, RE- SHORING AND SAFETY PRACTICES: N.T.S. pop-MR-M 11-0 A RIM SPECIFIED BY A FLORIDA REGISTERED ENGINEER WHO 0=0 *zoom 111�_ 0,11"..0 SUPERVISE ALL SHORING AND RE- SHORING INSTALLATIONS AND I:► _ I 1 • SHALL CERTIFY TO OUR OFFICE THEIR ADEQUACY PRIOR _ .; � c,' r'� :: c 1 � 11 � - : � - �� �! If�.i��`�7�'1i>It!f�.�i:� 1:1 � 1 : 1 1 1 . • . 1 . � . I^ 1.1 �T 1 • 1 1 �r 1 `0-fa- w CONSULTANTS HE HIRES TO ADDRESS THEM. �' 1 1 : c #3 TIES ® 8" O.C. SPACE ® 15' O.C. OR LESS FOR ALL NON BEARING 1 1 1 1 1 •@ 1 •C' 1 OF MAX. 240 SQ. FT. 1:1 1 : 1 1 •C� 1 .C' 1 BEAM. PROVIDE BY SOFFIT BEAM MANUFACTURER. ALSO, PROVIDE TIE COLUMNS AT ALL CORNERS: AT THE END OF FRJANDNG WALLS EXCEEDING 2' -0" IN LENGTH WHEN OPENING 8' -0" IN WIDTH COLUMNS SHALL BE PROVIDED AT SUCH OPENINGS. WHEN OPENINGS ARE BETWEEN 3' -0" AND 8' -0" IN WIDTH SUCH O SHALL HAVE ONE # 5 VERTICAL REBAR AT EACH SIDE. THE VERTICASHALL BE PLACED IN GROUT FILLED CELLS AND SHALL EXTEND INTO AND INTO TIE BEAMS. ALL SUCH BARS SHALL BE CONTINUOUS FROM TO TIE BEAMS. ALL SPLICES WHERE NEEDED SHALL BE 30" MINIMUM. .1.1 . 1 . 1 1 . 1 HOOK TOP BARS. . 1 : 1 : -� - •1: . 1 1 - . • 1- 1� l 1�. - -�• ••• too - W.-M 1 .1 =. 1 . 1 1 •1.1 ' 1 . 1 x2'-_/' ;: WTIM •1 1 rt.-W[MM-111t MA AWW"o A CONT. 16%127 "__CO ` -_ CO _� : : - / 1 1 S '•' FOOTING * ADD 2 #5 INTERMEDIATE BARS EA. FACE ** PROVIDE #3 TIES @ 12" O.C. 2 3 4 5 6 7 I 8 I 9 I 10 1. GENERAL NOTES A. UNLESS SHOWN OR NOTED OTHERWISE ON THE DRAWINGS OR IN THE SPECIFICATIONS. THE FOLLOWING NOTES SHALL APPLY TO MATERIALS LISTED HERINAFTER FOR USE IN THIS PROJECT. B. ALL ELEVATIONS ARE REFERENCED TO 0' -0" =11.00 N.G.V.D. 2. DESIGN CRITERIA A. GENERAL DESIGN LIVE LOAD - ROOF --------------------------- - - - - -- 30 PSF OVERALL FLOOR LOAD ------------- - - - - -- 80 PSF LOBBIES ------------------------ - - - - -- 100 PSF CORRIDORS ---------------------- - - - - -- 100 PSF MECHANICAL AND KITCHEN AREAS --- - - - - -- 150 PSF STORAGE ------------------------ - - - - -- 125 PSF B. SUPERIMPOSED DEAD LOAD PARTITIONS --------------------- - - - - -- 20 PSF MISC --------------------------- - - - - -- 10 PSF REFER TO STRUCTURAL PLANS FOR ADDITIONAL CONCENTRATED DEAD LOADS. C. WIND LOAD -IN ACCORDANCE WITH THE 1994 SOUTH FLORIDA BUILDING CODE AND ANSI /ASCE 7 -93 STANDARD " MINIMUN DESIGN LOADS FOR BUILDINGS AND STRUCTURES. BASIC WIND SPEED V = 110 MPH BUILDING LOCATION - -- HURRICANE OCEAN LINE BUILDING CLASSIFICATION - - -- IMPORTANCE FACTOR I = 1.05 EXPOSURE CATEGORY - - - - - -- C 3. SOIL STATEMENT: FOUNDATION INVESTIGATION AND RECOMMENDATIONS BY PSI INC. (PROJECT NO. 397 - 55076 -02, DATED 11/14/95, INDICATE SANDY LIMESTONE WITH A SAFE BEARING RESISTANCE OF 5 K.S.F. BOTTOM OF ALL FOOTINGS MUST BEAR ON EXISTING LIMESTONE. CONTRACTOR MUST FAMILIARIZE HIMSELF WITH THE REFERENCED GEOTECHNICAL REPORT. FOOTINGS FOR THIS PROJECT HAVE BEEN DESIGNED TO COMPLY WITH SAID REPORT. 4. CONCRETE: A. COMPRESSIVE STRENGTH OF CONCRETE AT 28 DAYS: COLUMN (UNLESS NOTHERWISE ON SCHEDULE)- 5,000 P.S.I. BEAMS (U.N.0) -------------------- - - - - -- 4,000 P.S.I. ELEVATED SLABS ------------------- - - - - -- 4,000 P.S.I. SLABS ON GRADE ------------------- - - - - -- 3,000 P.S.I. FOOTINGS ------------------------- - - - - -- 3,000 P.S.I CONCRETE WALLS ------------------- - - - - -- 4,000 P.S.I. ALL OTHER CONCRETE --------------- - - - - -- 3,000 P.S.I. B) MAXIMUM SLUMP (U.O.N.): 4 "+ 1" C) TESTS: A MINIMUM OF FIVE CONCRETE SPECIMENS SHALL BE TAKEN FROM EACH 50 CU. YDS. OR PORTION THEREOF. SPECIMENS SHALL BE TESTED ACCORDING TO ASTMC -39, ONE AT THREE DAYS, ONE AT 7 DAYS AND THREE AT 28 DAYS. NOTE: IF ONE OR MORE OF THE FIRST TWO CYLINDERS BROKEN AT 28 DAYS FAILS TO MEET SPECIFIED STRENGTH, HOLD THE THIRD ONE AND NOTIFY OUR OFFICE. D) COVER: CONCRETE DEPOSITED AGAINST THE GROUND ---- - - - - -- 3" FORMED CONCRETE IN CONTACT WITH THE GROUND - -- 2" BEAMS AND COLUMNS------------------------- - - - - -- 1 -1 /2" _ SLABS AND WALLS=----------------------------- -3/4,' ALL CONCRETE SLABS EXPOSED TO THE ELEMENTS MUST EITHER BE SEALED AFTER POURING OR INTEGRALLY WATERPROOFED IN THE MIX IN ORDER TO PREVENT WATER OR MOISTURE INTRUSION. COLUMNS AND WALL BELOW GRADE MUST BE PROTECTED CONTINUOUSLY WITH A WATERPROOFING MEMBRANE. CRACKS IN CONCRETE ARE TO BE ANTICIPATED. G.C. SHALL BE RESPONSIBLE FOR SEALING AND FILLING ALL CRACKS. G.C. SHALL SUBMIT TO ENGINEER, IN WRITING, LOCATION AND DESCRIPTION OF ALL CRACKS AND PROPOSED- METHOD FOR REPAIRS OF SAID CRACKS PRIOR TO REPAIRS. 5. REINFORCING STEEL: A REINFORCING BARS MUST CONFORM WITH ASTM A -615, GRADE 60. B WELDED WIRE FABRIC MUST CONFORM WITH ASTM A -185 AND SUPPORTED ON SLAB BOLSTERS SPACED AT 3' -0" MAXIMUM ON CENTER. C FABRICATION AND DETAILING ACCORDING TO ACI -315. D ALL ACCESSORIES TO HAVE UPTURNED LEGS AND BE PLASTIC- DIPPED AFTER FABRICATION. 6. PRECAST PRESTRESSED CONCRETE: A) ALL PRESTRESSED CONCRETE MEMBERS SHALL BE DESIGNED, FABRICATED AND ERECTED AS PER THE SOUTH FLORIDA BUILDING CODE AND ACI -318. SUBMIT STRUCTURAL SUBMISSIONS FOR OUR REVIEW AS AN INDICATION THAT OUR INTENT HAS BEEN UNDERSTOOD AND THAT THE SPECIFIED CRITERIA HAS BEEN USED. STRUCTURAL SUBMITTALS SHALL INCLUDE COMPONENT DETAILS, CALCULATIONS, AND FABRICATION AND ERECTION DRAWINGS. ALL SUBMITTALS SHALL IMPRESSED SEAL AND SIGNATURE OF THE SPECIALTY ENGINEER WITH FLORIDA REGISTRATION. PRESTRESSED CONCRETE SUPPLIER MUST BE RESPONSIBLE FOR THE INSTALLATION OF THE PRESTRESSED CONCRETE MEMBERS AND MUST ALSO HAVE MINIMUM OF FIVE YEARS OF LOCAL EXPERIENCE IN THE FABRICATION AND INSTALLATION OF SAID MEMBERS. B) PRESTRESSED JOISTS WITH COMPOSITE TOPPING SHALL BE DESIGNED FOR A SUPERIMPOSED LOAD AS SHOWN IN PLANS. SPACE JOISTS TO CLEAR ALL ITEMS SHOWN IN ARCHITECTURAL, MECHANICAL AND ELECTRICAL DRAWINGS AND THOSE SUPPLIED BY OTHER SUBCONTRACTORS. C) SOFFIT BEAM CALCULATIONS MUST BE SUBMITTED AND SEALED BY A REGISTERED PROFESSIONAL ENGINEER FOR REVIEW FOR COMPLIANCE WITH DESIGN LOADINGS. D) PRESTRESSED DOUBLE TEE UNITS WITH COMPOSITE TOPPING SHALL BE DESIGNED FOR A SUPERINPOSED LOAD AS SHOWN IN GENERAL NOTES AND PLANS. COORDINATE OPENINGS AND ADDITIONAL LOADINGS WITH ARCH. AND MECHANICAL DRAWINGS. E) THE SPECIALTY ENGINEER RESPONSIBLE FOR THE STRUCTURAL DESIGN OF THE PRECAST PRESTRESSED CONCRETE JOISTS AND SOFFIT BEAMS ALSO BE RESPONSIBLE FOR THE FABLICATION OF THESE STRUCTURAL ELEMENTS AND THE PREPARATION OF THE SHOP DRAWING,SHORING AND ERECTION DRAWING. THE SAME SPECIALTY ENGINEER SHALL SEE THAT THE ERECTION OF THE JOISTS, THE SOFFIT BEAMS, THE DECKING AND FORMWORK IS INSTALLED AND ERECTED AS REQUIRED TO MAKE THE SYSTEM WORK IN ACCORDANCE WITH HIS DESIGN. PRIOR TO THE CONCRETE BEING POURED ON THE SITE THE SPECIALTY ENGINEER SHALL FURNISH THE GENERAL CONTRACTOR AND THE ENGINEER OF RECORD WITH A SEALED LETTER ATTESTING TO THE FACT THAT HE HAS INSPECTED THE SHORING AND FOUND IT TO MEET HIS REQUIREMENTS AS SHOWN IN THE SHORING DRAWING. 7 I 8 19 I 10 11 I 12 I 13 I 14 I 15 I 16 I 17 I 18 GENERAL STRUCTURAL NOTES AS I F) SOFFIT BEAMS: CONTACT AREAS BETWEEN PRESTRESSE AND POURED IN PLACE 15. COLD FORMED METALS: CONCRETE SHALL BE CLEAN, FREE OF LAITANCE AND INTENTIONALLY A) REFER TO ARCHITECTURAL DRAWINGS FOR CONFIGURATIONS. ROUGHENED TO A FULL AMPLITUDE OF APPROXIMATELY 1/4 ". B) SUBMIT SIGNED AND SEALED CALCULATIONS BY FLORIDA P.E. AS WELL AS SIGNED AND SEALED PLANS AND CONNECTION DETAILS. DESIGN FOR WIND LOADS AS PER ANSI A58.1 (1982). INCLUDE PLACING DRAWINGS 7. STRUCTURAL STEEL: FOR FRAMING MEMBERS SHOWING SIZE AND GAGE DESIGNATIONS, NUMBERS, A) CONFORMING TO ASTM A -36. STEEL TUBE COLUMNS CONFORMING TYPE, LOCATION AND SPACING. INDICATED SUPPLEMENTAL STRAPPING, BRACING, TO ASTM A -500, GRADE B. SPLICES, BRIDGING, ACCESSORIES, AND DETAILS REQUIRED FOR PROPER B) BOLTS CONFORMING TO "SPECIFICATION FOR STRUCTURAL JOINTS INSTALLATION. USING ASTM A -325 AND ASTM A -490 BOLTS'. C) ALL EXPOSED STEEL MEMBERS (INCLUDING INSERTS AND CONNECTORS) TO BE HOT- DIPPED GALVANIZED. ALL OTHERS TO HAVE A MINIMUM 1.5 MIL OF RUST - INHIBITING PAINT. 16. PRICING QUANTITIES: TOUCH -UP AS REQUIRED AFTER ERECTION. D) FABRICATION AND- ERECTION ACCORDING TO THE LATEST AISC FOR PRICING PURPOSES, ASSUME (AS MINIMUN) THE FOLLOWING QUANTITIES SPECIFICATIONS. FOR UNSCHEDULED STRUCTURAL ELEMENTS: E) ALL WELDING TO BE PERFORMED BY CERTIFIED WELDERS IN COMPLIANCE WITH AWS D- 1.1 -77. ELECTRODES TO COMPLY 1.) CONCRETE BEAMS: WITH ASTM A -233 OR A -316 STORED AS PER AWS REQUIREMENTS. STORED AS PER AWS REQUIREMENTS. A. SOFFIT BEAMS : Mu = 450 FTK, Vu = 175K "C TOP STEEL: 4 #9 CONT. W/5 #10 BARS. SHEAR FRICTION : 4 #10 BARS 8. MASONRY WALLS: A) MASONRY SHOWN IS NON- BEARING AND MUST BE ERECTED AFTER B. "WET" BEAMS THE STRUCTURE TOP STEEL: 6 #10 BOTTOM ABOVE BEEN ERECTED AND ANTICIPATED DEFLECTION HAS TIES: #3 ®6' TIES OCCURRED. "r' BARS: 2 #6 ® 1/3 PTS FOR BM'S OVER 30" DEEP. B) MORTAR MUST CONFORM WITH ASTM C -270, TYPE M (2,500 P.S.I.). F'M OF BLOCK 2.) CONCRETE COLUMNS: UNITS = 2,500 P.S.I. C) PROVIDE STANDARD DUROWALL REINFORCING EVERY OTHER COURSE VERTICAL REINFORCING: 2.5% OF GROSS AREA. AND LAP AROUND CORNERS AND WALL INTERSECTIONS WITH TIES: #3® LEAST COLUMN DIMENSION. PREFABRICATED "L" AND "T" CORNER SECTIONS. D) LAP ALL VERTICAL BARS 48 BAR DIAMETERS. FILL SPECIFIED 3.) CONCRETE WALLS: CELLS WITH 3,000 P.S.I. CONCRETE PUMP MIX CONSOLIDATED IN MAXIMUM HEIGHTS OF FOUR FEET (ALTHOUGH WALL MAY BE VERTICAL REINFORCING: 2.5 % OF GROSS AREA. ERECTED HIGHER AT THAT POINT). PROVIDE CLEAN -OUT HORIZONTAL REINFORCING: $4 ®12" EACH FACE.. HOLES AT BOTTOM OF EACH REINFORCED CELLNTS AS REQUIRED. ALL SHOP DRAWINGS, PRIOR TO BEING SUBMITTED TO OUR THESE VALUE ARE NOT TO BE USED FOR CONSTRUCTION PURPOSES. OFFICE, MUST BE STAMPED BY BOTH THE ARCHITECT AND THE G.C. AS EVIDENCE OF THEIR PREVIOUS REVIEW. UNAUTHORIZED DUPLICATION OF OUR PLANS TO BE PRESENTED AS PART OF THE SUBMITTAL, IS STRICTLY 17. STAIR / ELEVATOR BEAMS: FORBIDDEN. A. STAIR BEAMS AND ELEVATOR BEAMS SHALL BE DESIGNATED "STB" AND "ELB" RESPECTIVELY, (SEE SECTION). 9. SOIL COMPACTION: FILL AND BACKFILL UNDER CONCRETE SLABS ON GRADE MUST BE B. "STY" AND "ELY" SHALL BE 8"X24 WITH 2 #8 BOTTOM COMPACTED TO A MINIMUM OF 95% OF THE MAXIMUM DENSITY AT AND 2 #6 TOP & CLOSED TIES #3 ®10" O.C. OPTIMUM MOISTURE AS DETERMINED BY THE MODIFIED PROCTOR TEST (ASTM D -1557, METHOD D) LINTEL BEAMS: 10. SLABS ON GRADE: TO BE PLACED ON CLEAN, NON - ORGANIC GRANULAR FILL ON A. LINTEL BEAMS MAY BE PRECAST OR CAST -IN -PLACE CONCRETE. 8 -MIL VISQUEEN VAPOR BARRIER AND IN A "CHECKERBOARD" SEQUENCE, EACH SEGMENT OF WHICH IS NOT TO EXCEED A B. FOR PRECAST LINTELS USE 8"X8" WITH 2 #5 TOP AND 2 #5 BOTTOM. MAXIMUM AREA OF 625 SQ. FT., OR 30 LINEAR FEET IN ANY DIRECTION AND AT ALL COLUMN LINES. PREMOLDED METAL C. FOR CAST -IN -PLACE CONCRETE LINTELS USE 8"X8" WITH 2 #5 BOTTOM. KEYED JOINTS (FULL SLAB THICKNESS) MAY ALSO BE USED. CUT WIRE FABRIC AT ALL JOINTS. D. LINTELS CONNECTING INTO MASONRY WALL HAVE 8" MIN. BEARING. 11. APPROVALS: A) SUBMIT SHOP DRAWINGS FOR ITEMS 5 AND 6 ABOVE. SUBMIT E. CIP LINTELS CONNECTING INTO WALLS OR COLUMNS SEE DETAILS. ONE PRINT AND ONE SEPIA OF EACH. CONTRACTOR WILL ISSUE PRINTS AS REQUIRED. ALL SHOP DRAWINGS, PRIOR TO BEING LINTEL SUBMITTED TO OUR OFFICE, MUST BE STAMPED BY BOTH THE ARCHITECT AND THE G.C. AS EVIDENCE OF THEIR PREVIOUS REVIEW. UNAUTHORIZED DUPLICATION OF OUR PLANS TO BE PRESENTED AS PART OF THE SUBMITTAL, IS STRICTLY ROUGHENED FORBIDDEN. 2 #5 TOP & BOT. SURFACE B) SUBMIT LABORATORY REPORTS FOR ITEMS 4 AND 7. DOWELS. 12. COORDINATION: COORDINATE ALL DIMENSIONS, ELEVATIONS, OPENINGS AND DETAILS WITH ARCHITECTURAL, ELECTRICAL AND MECHANICAL WALL OR COL. DRAWINGS. REPORT ANY CONFLICTS OR DISCREPANCIES TO OUR OFFICE. IN CASE OF CONFLICTS OR DISCREPANCIES, CONTRACTOR MUST ASSUME COSTLIER SOLUTION DURING BIDDING UNLESS CLARIFICATION IS OBTAINED IN WRITING FROM THE LINTEL DETAIL ARCHITECT. 13. SHORING, RE- SHORING AND SAFETY PRACTICES: N.T.S. ALL SHORING AND RE- SHORING IS TO BE DESIGNED AND SPECIFIED BY A FLORIDA REGISTERED ENGINEER WHO SPECIALIZES IN FORMWORK DESIGN AND WHO HAS BEEN HIRED BY THE GENERAL CONTRACTOR. SHORING ENGINEER SHALL SUPERVISE ALL SHORING AND RE- SHORING INSTALLATIONS AND SHALL CERTIFY TO OUR OFFICE THEIR ADEQUACY PRIOR TO ANY POUR. OUR OFFICE DOES NOT POSSES, NOR PRESUMES TO POSSES, ANY KNOWLEDGE OR EXPERTISE IN MATTERS RELATING TO JOB SAFETY, OSHA OR LABOR LAW REQUIREMENTS FOR A CONSTRUCTION PROJECT. SAFETY AND COMPLIANCE WITH OSHA AND LABOR LAWS IS THE ABSOLUTE RESPONSIBILITY OF THE GENERAL CONTRACTOR AND THOSE CONSULTANTS HE HIRES TO ADDRESS THEM. 14. TIE COLUMNS: PROVIDE 8"X12" (MIN.) TIE COLUMNS REINF. W/ 4 #6 VERTICAL AND #3 TIES ® 8" O.C. SPACE ® 15' O.C. OR LESS FOR ALL NON BEARING CONCRETE BLOCK WALLS IN ORDER NOT TO EXCEED UMBRACED AREAS OF MAX. 240 SQ. FT. EXIST. TIE COLUMNS SHALL BE ATTACHED TO SOFFIT BEAMS ABOVE WITH L4" X4" X3/8" X10" WITH 2- 11Z' DIA. WELDED ANCHORS EMBEDED IN SOFFIT BEAM. PROVIDE BY SOFFIT BEAM MANUFACTURER. ALSO, PROVIDE TIE COLUMNS AT ALL CORNERS: AT THE END OF FRJANDNG WALLS EXCEEDING 2' -0" IN LENGTH WHEN OPENING 8' -0" IN WIDTH COLUMNS SHALL BE PROVIDED AT SUCH OPENINGS. WHEN OPENINGS ARE BETWEEN 3' -0" AND 8' -0" IN WIDTH SUCH O SHALL HAVE ONE # 5 VERTICAL REBAR AT EACH SIDE. THE VERTICASHALL BE PLACED IN GROUT FILLED CELLS AND SHALL EXTEND INTO AND INTO TIE BEAMS. ALL SUCH BARS SHALL BE CONTINUOUS FROM TO TIE BEAMS. ALL SPLICES WHERE NEEDED SHALL BE 30" MINIMUM. 11 I 12 I 13 I 14 I 15 I 16 17 W191 111 NATIONAL CITY CENTER P.O. BOX 7033 INDIANAPOLIS, IN 46207 (317) 636 -1600 LI THE COMR COMPANY Y 1111 Lincoln Road Mall Suite 510 Miami Beach, FL. 33139 (305) 532 -0433 K � ==M�m J q I� �a I t__ WIII I • 11 ARCHITECTURE • ENGINEERING PLANNING • INTERIOR DESIGN 5960 S.W. 57TH AVE. MIAMI, FLORIDA 33143 TEL (305) 666 -5474 FAX (305) 666 -4994 EAA 0002416 EB 0002354 EUGENIO M. SANTIAGO, P.E. EGISTERED ENGINEER (CIVIL /STRUCT. FL. REG. NO. 19673 ISSUE DATE °o » Cq c °° REVISION DATE 08 -07 -96 PRICING DOC. 12 -10 -96 0 20 01 -14 -97 z U w 0 B CADD FILE NAME S801 -RT DRAWING TITLE FOOTING SCHED. & DTLS. SHEET NUMBER A 58.01 OF