Loading...
12-86 4OF7-045M u J H G F F C lso] r� 1 2 3 4 (:A Al 1' -4" COL. • #5 @48" O.C. BLDG. VERT. REINF.(IN FULLY GROUTED BLOCK CELL) LINE ADD'L T P EINF. 8" X8" CONC. CAP SEE PLAN. W/ 2 #5 CONT. co SLAB REINF.NOT SHOWN FOR CLARITY, SEE STRUCT.NOTES w +16' -0" co IF lip 0 CONC. BEAM, d FOR REINF. 0 AND SIZE, SEE BM. SCHED. ° d I° P.C. JTS.SEE PLAN SOFFIT BEAM,FOR REINF. AND SIZE, SEE BM, SCHED. n 8" WIDE COL. BEYOND 2/BA5.02 1 SECTION S5.04 SCALE:3 /4 " =1' -0" G/ DtiiJ.va 5 SECTION S5.04 SCALE:3 /4 " =1' -0" COLD- FORMED METAL 19 20 19.8 JOISTS. SEE STRUCTURAL NOTE ON DWG. s„ VARIES +77' -5" (MAX.) Ffih +66' -0" T.O.BM. RAKED TIE BM. FOR REINF. AND SIZE, SEE BM. SCHED. #6 @24'O.C.IN GROUT— FILLED CELLS. 5 6 7 8 9 10 11 12 A Al CONC. SLA W/#3@12", EA. WAY O °i #5 @48" O.C. SLAE VERT. REINF. ADD'L TOP REINF. FOR J— 111 (IN FULLY GRO SEE PLAN. BLOCK CELL) SLAB REINF.NOT SHOWN FOR CLARITY, SEE STRUCT.NOTES DD' + 2' -0" SEE dd 4 11 ° z w w d N CONC. BEAM, d FOR REINF. AND SIZE, SEE BM. SCHED. d 4, o d 8 ° CON FOR d d P.C. JTS.SEE PLAN - AND ° d SCH 8" WIDE COL. p SOFFIT BEAM,FOR REINF. BEYOND AND SIZE, SEE BM, SCHED: o ° 2/BA5.02 4" 2 SECTION �.14SCALE:3 /4 " =1' -0" 20 19.8 19 8 "X12" CONC. COL. BEYOND BETWEEN 16" X 16" COLS. d 16"X8" CONC. CAP SHEARWALL AT _ W/ 2 #5 CONT. ° co STAIR B2 CONC. BEAM, FOR REINF. AND SIZE, SEE BM. SCHED. WATERPROOFING ° MENBRANE & CONC. ° d TOPPING W /6X6 1'- " 147 W1.4XW1.4 W.W.F. ° jk +32' -0" d d d 9 SHEARWALL AT SEE PLAN FOR ° STAIR B2 REINFORCING. ° ° d ° ° #5@48"O C ° ° d LO ° 4 IN GROUT- FILLED CONC. BEAM, d CELLS (TYP.) ° FOR REINF. AND SIZE, SE SCHED. v d CONC. BEAM, FOR REINF. 14 ° d AND SIZE, SEE BM. d ° SCHED. °° 4,1 4„ 8 8" X 32" BEYOND 16 "WIDE CURVED BEAM. E:3i■m 0 s � 4 5 1 6 (V LO + J w 0 M CONC. COL. BEYOND 8 X12 ° BETWEEN 16" X 16" COLS. d ° 2/BA5.03 K'T SECTION S5.04 SCALE:3 /4 " =1' -0" TB COL. 8' CMU @ ELEV.+ 52' -0" ONLY ADD'L TOP REINF. SEE PLAN. SLAB REINF.NOT SHOWN Z FOR CLARITY, SEE STRUCT.NOTES w W Cn °° v d I ° d ° p ° d d G ° d d P.C. JTS.SEE PLAN v ° pd° SOFFIT BEAM,FOR REINF. AND SIZE, SEE BM, SCHED. ° COLUMN BEYOND $„ 81 3/BA5.02 (`_1oSECTION �.04SCALE:3 /4 " =1' -0" 7 _ � 8 9 13 14 I 15 16 8 "WALL BEYOND. in 8 "X8 "(MIN.) CONC. CAP W/2 #5 CONT. 12"X22" CONC. BM. W /210 TOP X 15' -0 ", 2 #8 BOT. X 12' -0" HK. BOTH #5 @24" CENTERED 7 AT OUTSIDE FACE OF PERIMETER IN GROUT AS SHOWN. d FILLED CELLS. p ADD'L TOP REINF. SEE PLAN. SLAB REINF.NOT SHOWN FOR CLARITY, SEE STRUCT.NOTES jk +52' -0" d �F7 p ° Id ° I d I ° -- — - - -4-- -- — -- 1-- ---� -- ° #3 @4 "TIES DBL -TEE Ir -- AT CANT. CANT. SEE PLAN II I I CONC. BEAM, 1 -4.. �- CONC.COL. FOR REINF. BEYOND AND SIZE, SEE BM. SCHED. CONC.SHEARWALL 3/BA5.02 K'T SECTION S5.04 SCALE:3 /4 " =1' -0" 20 19.8 CURVED 24" WIDE CONC.BM W/3 #8 TOP 3 #8 BOT. 4 #5 1 CONT.& #3 @16" TIES. MASONRY PIER BEYOND. 10 X 16" COL. �ON D FAIR ROOF (132) EE PARTIAL PLAN +40' -5" B COL. 4' CONC. SLAB W/#3@12" CENTERED EQ. WAY CONT. d #5 @48 "O.C. VERT. REINF.(TYP.) ADD'L TOP REINF. SEE PLAN. SLAB REINF.NOT SHOWN Z FOR CLARITY, SEE STRUCT.NOTES w w V) d d v d ° ° ° d ° d p ° e ° a d ° dp d DBL. TEE,SEE PLAN [SOFFIT BEAM BEYOND,FOR REINF. AND SIZE, SEE BM, SCHED. CONC.COLUMN BEYOND 3/BA5.02 KT1SECTION S5.04 SCALE:3 /4 " =1' -0" 11 I 12 181 +55' -0" T.O.SLAB +520" 1' -0" 10' 74" 12" BLOCK WALL BEYOND LOUVER OPNG. SDEE' PLAN. REINF.—\ dill■ ■119 ° ° ° v d ° ° ° d d v d ° ° SEE PLAN FOR ° d ° d ° REINFORCING. ° ° d ° d ONC. BEAM, _-ZI d ° ° OR REINF. AND SIZE, SEE BM. CHED. ° d d d ° 8" MASONRY BLOCK d WALL. v rj O d ° d ° jk +49' -0" BOT.OF BM. 2/BA5.03 8 SECTION S5.04 SCALE:3 /4 " =1' -0" 17 [Use � z SECTION S5.04 SCALE:3 /4" =1' -0" 14 15 1 16 17 18 u K NATIONAL CITY CENTER P.O. BOX 7033 INDIANAPOLIS, IN 46207 (317) 636 -1600 THE COMRAS COMPANY 1111 Lincoln Road Mall Suite 510 Miami Beach, FL. 33139 (305) 532 -0433 J o I � o a Tj F H � g G F 1"t•\ ITT a I� l� ARCHTfHC= - HNGINMIING PLANNING -WnMOR DESIGN v v d ° i ° d FAX (305) 666 -4994 d E:3i■m 0 s � 4 5 1 6 (V LO + J w 0 M CONC. COL. BEYOND 8 X12 ° BETWEEN 16" X 16" COLS. d ° 2/BA5.03 K'T SECTION S5.04 SCALE:3 /4 " =1' -0" TB COL. 8' CMU @ ELEV.+ 52' -0" ONLY ADD'L TOP REINF. SEE PLAN. SLAB REINF.NOT SHOWN Z FOR CLARITY, SEE STRUCT.NOTES w W Cn °° v d I ° d ° p ° d d G ° d d P.C. JTS.SEE PLAN v ° pd° SOFFIT BEAM,FOR REINF. AND SIZE, SEE BM, SCHED. ° COLUMN BEYOND $„ 81 3/BA5.02 (`_1oSECTION �.04SCALE:3 /4 " =1' -0" 7 _ � 8 9 13 14 I 15 16 8 "WALL BEYOND. in 8 "X8 "(MIN.) CONC. CAP W/2 #5 CONT. 12"X22" CONC. BM. W /210 TOP X 15' -0 ", 2 #8 BOT. X 12' -0" HK. BOTH #5 @24" CENTERED 7 AT OUTSIDE FACE OF PERIMETER IN GROUT AS SHOWN. d FILLED CELLS. p ADD'L TOP REINF. SEE PLAN. SLAB REINF.NOT SHOWN FOR CLARITY, SEE STRUCT.NOTES jk +52' -0" d �F7 p ° Id ° I d I ° -- — - - -4-- -- — -- 1-- ---� -- ° #3 @4 "TIES DBL -TEE Ir -- AT CANT. CANT. SEE PLAN II I I CONC. BEAM, 1 -4.. �- CONC.COL. FOR REINF. BEYOND AND SIZE, SEE BM. SCHED. CONC.SHEARWALL 3/BA5.02 K'T SECTION S5.04 SCALE:3 /4 " =1' -0" 20 19.8 CURVED 24" WIDE CONC.BM W/3 #8 TOP 3 #8 BOT. 4 #5 1 CONT.& #3 @16" TIES. MASONRY PIER BEYOND. 10 X 16" COL. �ON D FAIR ROOF (132) EE PARTIAL PLAN +40' -5" B COL. 4' CONC. SLAB W/#3@12" CENTERED EQ. WAY CONT. d #5 @48 "O.C. VERT. REINF.(TYP.) ADD'L TOP REINF. SEE PLAN. SLAB REINF.NOT SHOWN Z FOR CLARITY, SEE STRUCT.NOTES w w V) d d v d ° ° ° d ° d p ° e ° a d ° dp d DBL. TEE,SEE PLAN [SOFFIT BEAM BEYOND,FOR REINF. AND SIZE, SEE BM, SCHED. CONC.COLUMN BEYOND 3/BA5.02 KT1SECTION S5.04 SCALE:3 /4 " =1' -0" 11 I 12 181 +55' -0" T.O.SLAB +520" 1' -0" 10' 74" 12" BLOCK WALL BEYOND LOUVER OPNG. SDEE' PLAN. REINF.—\ dill■ ■119 ° ° ° v d ° ° ° d d v d ° ° SEE PLAN FOR ° d ° d ° REINFORCING. ° ° d ° d ONC. BEAM, _-ZI d ° ° OR REINF. AND SIZE, SEE BM. CHED. ° d d d ° 8" MASONRY BLOCK d WALL. v rj O d ° d ° jk +49' -0" BOT.OF BM. 2/BA5.03 8 SECTION S5.04 SCALE:3 /4 " =1' -0" 17 [Use � z SECTION S5.04 SCALE:3 /4" =1' -0" 14 15 1 16 17 18 u K NATIONAL CITY CENTER P.O. BOX 7033 INDIANAPOLIS, IN 46207 (317) 636 -1600 THE COMRAS COMPANY 1111 Lincoln Road Mall Suite 510 Miami Beach, FL. 33139 (305) 532 -0433 J o I � o a Tj F H � g G F 1"t•\ ITT a I� l� ARCHTfHC= - HNGINMIING PLANNING -WnMOR DESIGN 55.04 _ OF 5960 S.W. 57TH AVE. MIAMI, FLORIDA 33143 TEL (305) 666 -5474 FAX (305) 666 -4994 EAA 0002416 EB 0002354 EUGENIO M. SANTIAGO, P.E. EGISTERED ENGINEER (CIVIL /STRUCT. FL. REG. NO. 19673 DS. 4 �, `. . eo ISSUE DATE -o :o - REVISION DATE c 08-07-96 PRICING DOC. 12 -10 -96 0 Z 02 -12 -97 - U .w —j _0 -� CADD FILE NAME S504 —RT DRAWING TITLE SECTIONS AND DETAILS SHEET NUMBER A 55.04 _ OF