12-86 3OF7-1091
ro
SO
I K
I'
III
MIMI
I G
I F
IUD
IUD
C
ire
1 2 3 4 5 6 '7 8 9 10 1 11 12 13 1 14 1 15 16 17 18
LEGEND ROOF PLAN KEY NOTES
SYMBOL DESCRIPTION
74 -01 FULLY ADHERED SINGLE PLY
® TYPICAL ROOF WALKWAY PROTEC- ROOFING.
TION PAD.
75 -01 BUILT -UP ROOFING SYSTEM OVER
INDICATES TOP OF SLAB ELEVA- MIN. R =20 INSULATION BOARD
OS 0 TION (0'- 0"= 11' -0" NGVD) (MIN. 1 /8 /FT SLOPE).
VERIFY TOP OF SLAB ELEVATION
R.6 R.7 S.2 S.7 T.8 U.8 V.9 WITH STRUCTURAL DOCUMENTS 75 -02 TYPICAL ROOF WALKWAY PROTEC-
TION PAD.
INDICATES TOP OF METAL PARA-
PET ELEVATION (0'- ("= 11' -O7 76 -01 SLOPED METAL STANDING SEAM
Nom) ROOF SYSTEM.
D TYPICAL ROOF DRAIN WITH 76 -02 CURBED METAL STANDING SEAM
I 3Cr X 30" - 4 LB. LEAD ROOF.
I I I FLASHING.
76 -03 TAPERED PAN - STANDING SEAM
INDICATES TAPERED INSULATION/ METAL ROOF SYSTEM.
ROOFING CRICKET 0 1 /4 /FT MIN.
55'-911/9p ( I SLOPE. 76 -04 METAL PARAPET COPING. SEE
TOS
DETAIL F14 SHEET A8.10.
1 /8" /FT (TYP -) INDICATES DIRECTION OF SLOPED
77 -04 I I I ROOF. 76 -05 METAL ROOF SYSTEM RIDGE
O 0 INDICATES CURB MOUNTED ROOF FLASH
RO. F S M• MATCH
001, 1 TOPS I I TOP EQUIPMENT - SEE PLUMBING,
MECHANICAL & ELECTRICAL PLAN- 76 -06 METAL GUTTER SYSTEM, FINISH
' SEE DETAIL F10 SHEET A8.10. TO MATCH ROOF SYSTEM. SEE
6 -04 R 77 -04 I DETAIL SHEET
t INDICATES OVERFLOW METAL •
' I SCUPPER. SEE DETAIL J14 77 -01 TYPICAL ROOF EXPANSION JOINT-
SHEET A8.10 SEE DETAIL Al SHEET A8.10.
H.P. HIGH POINT. 77 -02 TYPICAL ROOF/WALL EXPANSION
OS I JOINT - SEE DETAIL J1
SHEET A8.10.
77 -03 PRE -FAB MECHANICAL CHILLER/
51'- 76 -04 'QO PENTHOUSE. SEE CURB
' TOP 19' -0" � -
DETAIL A14 SHEET A8.10.
TOP I XR' /g, Fl. METAL OVERFLOW SCUPPER WffH
/ �'•) OPENING WIDTH X HEIGHT
1 /8' /F (TYP.) R� I INDICATED. FOR EXACT LOCATION
SLOPE U.O.N.
SEE ELEVATIONS. SEE DETAIL
I I J14 SHEET A8.10.
77 -02 77 -01
76 -04 ( 77 -05 WALL MOUNTED A/C UNITS - SEE
TYPICAL CRICKET DETAIL 114 SHEET A8.09 AND
- - - ( - - - - - - - - - - - I - - - 2.2 SLOPE 1 /4 " /FT U.O.N. STRUCTURAL DRAWINGS.
I
77 -06 STEEL PIPE SUPPORT. FOR
I � Q. �p \ TYPICAL VALLEY FLASHING SEE DETAIL F6
1 /g, /FT ( •) SLOPE 1 /16" /FT MIN. SHEET A8.10
I Q�• 16' -0"
I Dc RD
�►� TOS SLOPE U.O.N. 77 -07 CURB MOUNTED ROOF TOP EQUIP.
Pte. 77 -01 SEE DETAIL F10 SHEET A8.10
RD
ROOF HATCH - SEE DETAIL J6
LID G� SHEET A8.10
ACCESS GATE FROM --�
5th FLOOR ON THE
GARAGE. (APRX. 50' -0")
TOS v OS
- 75- 1 TRDI \ / 77 -o4 .5 Y.1
).8
-I 76 4 -TOS W n ' Z.1
Z.2
9.4 ' / / W.4 / Z.3
\ / 10.4
00 /
' I
JA " .311 /
11.3
r
C11.4 / \\ / 12.1
�/
I/ \ /
12.3
12.8
-- - ------ - - ------ - - - - - - - --
I � I I � 12.7 - ,,/
/
13 .1
II I I I I
� 1 I fi / / / /
GENERAL NOTES
1. FOR LOCATION OF PLUMBING ROOF
VENTS SEE PLUMBING DOCUMENTS.
SEE DETAIL J10 SHEET A8.10
FOR FLASHING.
2. FOR LOCATION OF ALL HVAC ROOF
TOP EQUIPMENT SEE MECHANICAL
DOCUMENTS.
KEY PLAN
1
BLDG. D ROOF PLAN I
H j � " � l �
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18
6�n
�Lxw":