Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
12-86 2OF7-069
1 2 3 4 5 6 7 8 0 10 11 12 13 14 15 16 17 18 MMON PROPERTY EXPANSION JOINT COVER PLATES EXTEND 1/2" DRYWALL 2" ABOVE LINE OF FINISHED CEILING do PROVIDE GROUP MSEALANT 0 ANY GAPS M FOR FLOOR FINISH REFER CONTINUOUS EXTRUDED ALUMINUM 1V1 J -BEAD SEALANT AND BACKER ROD J -BEAD TO ROOM FINISH SCHEDULE (TYP.) COVER PLATE & FRAME HANGER WIRE (TYP.) NATIONAL CITY CENTER 5"' INDIANAPOLIS, IN 46207 - - - -- - - - - - -- (317) 636 -1600 i 2" 1 2" - -;. 0 0 - -_ - -- E.J. EXPANSION JOINT COVER PLAN Ld PLASTIC LAMINATE AND 3" X 3" X 3" X 1 /8" d EXPOSED EDGE STEEL CUP BOTH SIDES I OF BRACKET ' i 1 a I- I 4" BACKSPLASH W/ PLASTIC LAMINATE 1 C14 THE CC✓OMRAS C 1111 Lincoln Road Mall Suite 510 Miami 13sach, FL. 33139 (305 ) 532 -0433 K3/4" PLYWOOD COUNTERTOP v V w PLASTIC LAMINATE ALL EXPOSED SURFACES a Q q i �. - 3/4" PLYWOOD BRACKET. t PROVIDE PLASTIC LAMINATE N ON ALL EXPOSED SURFACES LSHIM AS REQUIRED METAL FIRE (MAX. 5' -0" O.C. SPACING) SHIELD - 2HR. RATED 2 X 4 WOOD BEAM 3/4" PLYWOOD BACKING BETWEEN STUDS AT EACH BRACKET :��AD V V 3/4" COLD - ROLLED CHANNEL T SECTION SEE PARTITION TYPES FOR CONSTRUCTION BATT INSULATION. REFER TO PARTITION TYPES GROUT (TYP) J 5/8" DRYWALL CEILING / SOFFIT J -BEAD 1 ri_i"' TYPICAL COUNTER / SHELF DETAIL r i5 TYPICAL INT. WALL EXP. JOINT COVER DETAIL i 1 o TYP. INTERIOR FLOOR EXP. JT. COVER DETAIL i 1 o TYPICAL DETAIL � .07 SCALE:N.T.S. a7.o7 SCALE :N.T.S. A7.o7 SCALE:N.T.S. A7.07 SCALE:N.T.S. @DRYWALL CEILING EXPANSION JOINT wr • 1 { Yr rV 0••• I CONCRETE WALL OR GLASS CURTAIN WALL SYSTEM �/ , • , ' PACK FULL WITH FIRE SAFING INSULATION W 6 PCF MINERAL WOOL \ 112" THICK SILICONE PIPE SUPPORT CLAMP- { { { { •' FIRESTOP SEALANT SEE PLUMBING /HVAC /ELECT. 1/T SILICONE 1 -PART /j % \ \\ TYPICAL "FYRE -SIL" DOCUMENTS. x 1/2" THICK "FYRE -SIL" SILICONE FIRESTOP FIRESTOP SEALANT (TYP.) / % \ BY TREMCO, INC. E-+ H SEALNT BY TREMCO, INC. WITH 4" MINERAL "FYRE- SIL" BY TREMCO, AINC./ % CONCRETE SLAB FIRESAFING INSULATION AND METAL CLIP j \. - - -- 0 24" O/C IF GAP IS OVER 1" WIDE / . j PIPE OR CONDUIT PORTLAND CEMENT PLASTER ' .YA. A n :"A NEW CONDUIT OR PIPE UNINSULATED OR INSULATED 4" FIRESAFING ^ ^ \ \ % % INSULATION G SEALANT AND BACKER -ROD ^ J ^ 1 / j 6 PCF MINERAL WOOL G AROUND PIPE BOTH SIDES ^ f ^ ^'♦ . A. 1 \ / 2 -HOUR RATING ^ ^ ^ \. /� / PIPE OR CONDUIT REQUIRED \ / AT EXPOSED I AT PLASTER CONDITION 1 do 2 -HOUR RATED CONCRETE SLAB BLOCK CONDITION FIRE RATED CHASE /SHAFT J, F I I HR. RATING UL # MANUFACTURER F- RATING T- RATING 2 J90OZO06 TREMCO 2 HRS. 0 HRS. u i � HR. RATING UL # MANUFACTURER F- RATING T- RATING 2 WL1019 TREMCO 2 HRS. 0 MRS. HR. RATING UL # MANUFACTURER F- RATING T- RATING 2 CAJ1064 TREMCO 2 HRS. 0 HRS. WOLFS ERG i F ALVAREZ ATun FARTNERS AACHrMCTURE • ➢NGINESIING RLANNING •IlVTIIt][06 DllSIGN ('_E1TYP. PIPE /CONDUIT PENETRATION DET. E5 TYP. SLAB- EDGE FIRESAFING - DETAIL E9 TYP. PIPE /CONDUIT FIRE SAFING DETAIL E14 PIPE /CONDUIT FLOOR PENETRATION DETAIL MIAMI,SFLO IDAH AVE. 33143 A7.o7 SCALEXT.S. @ NON RATED MASONRY WALLS A7-o7 SCALE:N.T.S. A7.17 SCALEXT.S. THROUGH CHASE STUD WALL (SHAFT WALL SIMILAR) . O7 SCALEXT.S. (305) 666 -5474 EE FAX (305) 666 -4994 A.A.C. 000404 D PROJECT DATUM - 11 N.G.V.D. = 0' -0" UL # TOP OF CURB TOP OF STRUC. T- RATING 2 TOP OF CURB TOP OF STRUC. 2 HRS. CURB CONCRETE CURB AND SLAB. SEE STRUCTURAL FOR REINFORCEMENT CHILLED WATER PIPE - WITH FOAMGLASS CONFIGURATION CURB A SLAB CONFIGURATION N.G.V,D. N.G.V.D. NN.G.V.D A5 INSULATION THROUGH RATED FLOORS ("A 9 INS. THROUGH RATED DRYWALL PARTITIONS FOAM INSUL. (ARMAFLEX) THRU DRYWALL ARCH. ARCH. A7.o7 SCALE:1 1/2" = 1' -0" a7.o7 SCALE:N.T.S. ARCH - A 10.85 10.60 A.- STRAIGHT F 11.05 10,60 2 Al.- CURVED 4 - ' -1 3 4" - ' -4 3Z4! 7 +0' -1 0 10 B 10.50 10.25 B.- STRAIGHT G 11.20 10.60 18 B1.- CURVED of ' -2 3 8" - '-4 3 4" C 10.90 10.65 C.- STRAIGHT H 11.00 10.75 Cl.- CURVED 1/4! D 10.55 10.30 D.- STRAIGHT I 11.24 10.75 D1.- CURVED - ' -5 3 6. ' -2 71e" E 10.60 10.35 J 11.12 10.75 - ' -4 3 4" - ' -7 3/4!1 NOTE: FOR ALL CURVED CONFIGURATIONS, SEE GEOMETRY PUN. X. MARCEL R. MORLOTE, A.I.A. \. \. PIPE / / \ \ / // \ \ FL. ARCHITECT \ FL. ARCH. REG. N0. 9564 METAL JACKET SPACE. SECURED TO PIPE WITH 2 METAL /� // \� CELLULAR GLASS INSULATION % // \� \\ ........ HOSE CLAMPS /. / \ .\ \ .\ TREMSTOP WBM, MIN. 1" /j / \. \\ TREMSTOP WBM, MIN. 1" MIN. 1" THICK PIPE SUPPORT CLAMP- \. THICK, BY TREMCO, INC. % % \ \ THICK, BY TREMCO, INC. TREMSTOP WBM SEE PLUMBING /HVAC /ELECT. / 1" MIN. BY TREMCO, INC. DOCUMENTS. / - WIDE CONCRETE SUB PIPE % PIPE ISSUE DATE A n ,c A' ^ 8" CONCRETE BLOCK WALL. (TYPICAL, A • .: ^ . 112" MIN. c� UNLESS OTHERWISE NOTED) ,n A ^ n, n 1 1/2" MAX. \ \ % \ % % : O C C REVISION DATE AB \ / / PVC FLEXIBLE \ \ \ i / 08 -07 -96 4" FIRESAFING FOAM INSULATION (ARMAFLEX) 1" \ % _ PRICING D 0 C . 2" V. 3'-Cr TYPICAL UNLESS OTHERWISE NOTED - - INSULATION COMPRESSED 507: 6 PCF MINERAL WOOL \. �� TOP OF CURB _ \. / \ / PORTLAND CEMENT 2-HOUR RATING \ �. % / METAL JACKET (BOTH SIDES) \ \ % % = •• PLASTER SEE CHART REQUIRED / / / / FIRE RATED GYPSUM % AND SECURED WITH 2 FIRE RATED GYPSUM % = \. / / \. // p WALLBOARD. SEE \. / METAL HOSE CLAMPS WALLBOARD. SEE \. / Z CELLULAR GLASS PARTITION TYPES FOR \. % // PARTITION TYPES FOR \ j INSULATION \ / \ / ~ CONSTRUCTION \ / CONSTRUCTION \ / DQ D e D • TOP CHART SLAB D IF ANNULAR SPACE IS LESS 1 2 --HOUR RATED \ 1 Ik 2 -HOUR RATED p THAN 114, ALSO APPLY 11Z BEAD OF TREMSTOP WBE AT FIRE RATED CHASE /SHAFT J, FIRE RATED CHASE /SHAFT J, _ CONTACT POINT B SIDEWALK. SEE COMPACTED FINISH CIVIL DRAWINGS GRADE HR. RATING UL # MANUFACTURER F- RATING T- RATING 2 CAJ5071 TREMCO 2 HRS. 1 HR. HR. RATING UL # MANUFACTURER F- RATING T- RATING 2 WL5002C TREMCO 2 HRS. 1 1/2 HRS. HR. RATING UL MANUFACTURER F- RATING T- RATING 2 WL5003C TREMCO 2 HRS. 1 HR. "Imuu I ILL IYFI IVIL A707- RT.DWG DRAWING TITLE MISC. INT. DETAILS I A CONCRETE CURB AND SLAB. SEE STRUCTURAL FOR REINFORCEMENT CHILLED WATER PIPE - WITH FOAMGLASS C HILLED WATE R PIPE WITH F AM LA ss WALL METAL PIPE PENETRATION DETAIL WITH A SHEET NUMBER A CURB -SLAB EDGE DETAIL A5 INSULATION THROUGH RATED FLOORS ("A 9 INS. THROUGH RATED DRYWALL PARTITIONS FOAM INSUL. (ARMAFLEX) THRU DRYWALL A7.o7 SCALE:1 1/2" = 1' -0" a7.o7 SCALE:N.T.S. A7,07 A7.o7 SCALEXT.S. A7.07 SCALE:N.T.S. 1 2 3 4 5 6 7 8 0 10 11 12 13 14 15 16 17 18 of