Loading...
12-86 1OF7-2031 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 MMON PROPERTY EXPANSION JOINT COVER PLATES EXTEND 1/2" DRYWALL GROU. p SEALANT ® ANY GAPS M FINISHED CEILING &PROVIDE ' r FOR FLOOR FINISH REFER CONTINUOUS EXTRUDED ALUMINUM HANGER WIRE (TYP.) NATIONAL CITY CENTER • � J -BEAD SEALANT AND BACKER ROD J -BEAD TO ROOM FINISH SCHEDULE (TYP.) COVER PLATE & FRAME P.O. BOX 7033 5" INDIANAPOLIS, IN 46207 (317) 636 -1600 0 o E.J. EXPANSION JOINT COVER �jj�j�jj� --- - - - - -- --- - - - - -- THE llJ1.� L PLAN , L N CCOMRAS w PLASTIC LAMINATE AND 3" X 3" X S. X 1 /8" >< I I COMPANY EXPOSED EDGE STEEL CUP BOTH SIDES OF BRACKET I 2' -1" I 1111 Lincoln Road Mall n n n n Suite 510 4" BACKSPLASH W/ _ PLASTIC LAMINATE Mlami Beach, FL 33139 30 532 -0433 K3/4" PLYWOOD COUNTERTOP a V v V ` " V PLASTIC LAMINATE Q ALL EXPOSED SURFACES Q N 3/4" PLYWOOD BRACKET. PROVIDE PLASTIC LAMINATE SHIM AS REQUIRED METAL FIRE ' Z-4 ON ALL EXPOSED SURFACES SHIELD - 2HR. RATED (MAX. 5' -(" O.C. SPACING) 2 X 4 WOOD BEAM 3/4" PLYWOOD BACKING BETWEEN STUDS AT EACH BRACKET 3/4" COLD- ROLLED CHANNEL JSEE PARTITION TYPES FOR CONSTRUCTION BATT INSULATION. REFER TO PARTITION TYPES GROUT (TYP) SECTION 5/8" DRYWALL CEILING / SOFFIT J -BEAD K'71 TYPICAL COUNTER / SHELF DETAIL r i5 TYPICAL INT. WALL EXP. JOINT COVER DETAIL i 1 o TYP. INTERIOR FLOOR EXP. JT. COVER DETAIL i 1 o TYPICAL DETAIL A7.o7 SCALE:N.T.S. . O7 SCALE:N.T.S. A7.07 SCALE:N.T.S. A7.o7 SCALE:N.T.S. @DRYWALL CEILING EXPANSION JOINT A I I o CONCRETE WALL OR GLASS CURTAIN WALL SYSTEM j PACK FULL WITH FIRE SAFING INSULATION 6 PCF MINERAL WOOL R SSILICONE AC TOP S ALAN SEE PLUMB G/H /ELECT. 112" SILICONE 1 -PART -SI" DOCUMENTS. x 11f THICK "FYRE -SIL" SILICONE FlRESTOP FIRESTOP SEALANT (TYP.) BY TREMCO, INC. SEALNT BY TREMCO, INC. WITH 4" MINERAL "FYRE -SIL" BY TREMCO, INC. / \ \ CONCRETE SLAB H FIRESAFING INSULATION AND METAL CUP j / j �� H O ® 24 0/C IF GAP IS OVER 1 WIDE -------- PIPE OR CONDUIT PORTLAND CEMENT PLASTER Xn. ^ < • • v •nx• 1/4" ^' ' A A . . ^.. " • A " . V n O h NEW CONDUIT OR PIPE �^ n' UNINSULATED OR INSULATED \ / 4" FIRESAFING ^ a ^ % j INSULATION G r �. : , : ^. / 6 PCF MINERAL WOOL G SEALANT AND BACKER -ROD ^ AROUND PIPE BOTH SIDES ^ ti, .a 2 -HOUR RATING PIPE OR CONDUIT REQUIRED IA. /1 . J \ DIII-) \ \• / 1 & 2 -HOUR RATED AT EXPOSED i AT PLASTER CONDITION CONCRETE SLAB BLOCK CONDITION i FIRE RATED CHASE SHAFT HR. RATING UL MANUFACTURER F- RATING T- RATING i F I HR. RATING UL # MANUFACTURER F- RATING T- RAPING 2 CAJ1064 TREMCO 2 0 F A L�VAREZ HR. RATING UL I MANUFACTURER F- RATING T- RAPING HRS. HRS. 2 J900Z006 TREMCO 2 0 AND HRS. HRS. 2 WL1019 TREMCO 2 0 PAI�T�I�I�S� HRS. HRS. AR=CMn • ENGINEERING PLANNING • INTERIOR DESIGN ("'Ei�TYP. PIPE /CONDUIT PENETRATION DET. rE5 TYP. SLAB EDGE FIRESAFING DETAIL PIPE /CONDUIT FIRE SAFING DETAIL E14 PIPE /CONDUIT FLOOR PENETRATION DETAIL 5960 S.W. 57TH AVE. MIAMI, FLORIDA �.07 S CALE:N.T.S. @ NON RATED MASONRY WALLS A7.o7 SCALEXT.S. A7°o7 SCALE:N.T.S. THROUGH CHASE STUD WALL (SHAFT WALL SIMILAR) A7.o7 SCALE:N.T.S. 5) (305) 666 -5474 E EFAX (305) 666 -4994 1:J A.A.C. 000404 PROJECT DATUM - 11 N.G.V.D. = 0' -0" MARCEL R. MORLOTE, A.I.A. TOP OF CURB TOP OF STRUC. TOP OF CURB TOP OF STRUC. FL. ARCHITECT PIPE FL. ARCH. REG. N0. 9564 CURB SLAB CONFIGURATION CURB SLAB CONFIGURATION N.G.V.D. N.G.V.D. N.G.V.D. N.G.V.D. / \ �• / \ \' ARCH. ARCH. ARCH. ARCH. METAL JACKET SPACE. SECURED 10.85 10.60 A•- STRAIGHT 11.05 10.60 TO PIPE WITH 2 METAL A F CELLULAR GLASS INSULATION Al.- CURVED +0' -1 2" - ' -4 3/4! - 10.50 10.25 B•- STRAIGHT 11.20 10.60 / / \ \ » \ \ B G TREMSTOP WBM, MIN. 1 / \ TREMSTOP WBM MIN. 1 / D -0' -6" -0' -s" B1.- CURVED ' -2 3 - ' -4 3 4 MIN. 1 THICK PIPE SUPPORT CLAMP - TREMSTOP WBM SEE PLUMBING /HVAC /ELECT. THICK, BY TREMCO, INC. // 1" MIN. \ THICK, BY TREMCO, INC. d Ld 10.90 10.65 C °- STRAIGHT 11.00 10.75 \. C H BY TREMCO, INC. DOCUMENTS. / WIDE \. / / \ (/) - ' -1 1/4! - ' -4 1 4" C1.- CURVED " -0' -9" D 10.55 10.30 D.- STRAIGHT I 11.24 10.75 CONCRETE SLAB PIPE / PIPE 3/8m D1.- CURVED ' -2 7 -0' -9" E 10.60 10.35 J 11.12 10.75 NOTE: FOR ALL CURVED CONFIGURATIONS, SEE GEOMETRY PLAN. �` y �� � �, n ,,.. •h' ^. . • ..w• eA ^ •^: to f. .� n ,� ' _ O ISSUE DATE :o 8" CONCRETE BLOCK WALL (TYPICAL, ^' r < n 1/2" MIN. : GcV UNLESS OTHERWISE NOTED 1 1/2" MAX. \, \ / :O c ) °^ • � ^� � C REVISION DATE \. / AB / PVC FLEXIBLE \. / 0 8 -07-96 2" 6" 3' -0" TYPICAL UNLESS OTHERWISE NOTED 4" FIRESAFING MAX. 1 /2" 12" j j 12" FOAM INSULATION (ARMAFLEX) \ \ % PRICING D 0 C . INSULATION (COMPRESSED 50 %) 6 PCF MINERAL WOOL \ TOP OF CURB ` \. / / METAL JACKET PORTLAND CEMENT 2 -HOUR RATING (BOTH SIDES) • • ° PLASTER SEE CHART REQUIRED FIRE RATED GYPSUM \ / ' j AND SECURED WITH 2 FIRE RATED GYPSUM \ / /� = O p WALLBOARD. SEE METAL HOSE CLAMPS WALLBOARD. SEE /� = Z CELLULAR GLASS PARTITION TYPES FOR \. j PARTITION TYPES FOR \. j o INSULATION CONSTRUCTION �� j // CONSTRUCTION �\ j // : U T OF SLAB NOTE: \ \ / \ \ r : L� o \ % \ / : -� p 1> n SEE'- IF ANNULAR SPACE IS LESS 1 & 2 -HOUR RATED 1 & 2 -HOUR RATED All p THAN 1/4% ALSO APPLY 11f FIRE RATED CHASE /SHAFT FIRE RATED CHASE /SHAFT D B ' \ \ //� // /// ,} o. CONTACT POINT OP WBE AT D n- _ Q D / \ \ CAD D FILE NAME HR. RATING UL # MANUFACTURER F- RATING T- RATING HR. RATING UL MANUFACTURER F- RATING T- RATING HR. RATING UL # MANUFACTURER F- RATING T- RAT'1NG A707- RT.DWG 2 WL5002C TREMCO 2 1 1/2 2 WL5003C TREMCO 2 1 2 CAJ5071 TREMCO 2 1 SIDEWALK. SEE COMPACTED FINISH HRS. HR. HRS. HRS. HRS. HR. DRAWING TITLE _ MISC. INT. DETAILS CIVIL DRAWINGS GRADE CONCRETE CURB AND SLAB. SEE SHEET NUMBER A STRUCTURAL FOR REINFORCEMENT CHILLED WATER PIPE WITH FOAMGLASS CHILLED WATER PIPE WITH FOAMGLASS WALL METAL PIPE PENETRATION DETAIL WITH A A CURB -SLAB EDGE DETAIL I NSULATION THROUGH RATED FLOORS THROUGH RATED DRYWALL PARTITIONS FOAM INSUL. (ARMAFLEX) THRU DRYWALL n nil n In n n( �01SCALE:1 1/2" = P -0" A7.o7 SCALEXT.S. A7.o7 SCALE:N.T.S. A7.07 SCALE:N.T.S. A7,07 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 of