Loading...
12-86 1OF7-030M I L I 1 I i I III nu <r: IN 190 In In I B I IN F� 'A" F� 3 4 77- 5 6 7 8 9 10 t t 12 13 14 15 16 17 18 ------------------------------ - - - - - - - -- - --------- - I .. ' • 12rr 1 19 0 3 20 19 18 1 v 1 6 10.5 22.5 6.5 17 I 17 a . - :, .. TO BE INSTALLED BY . p • = 1 LO d LO a. M. D. W. A. S. A. D. 1 1 N • • N 12 2 :. I 12 11 10 a. •• •. • • 1 8 1 22 0 37" 18" 9,r 118 1 .. •. 8 9 TO BE INSTALLED B 7 16 5 1 a a M.D.W.A.S.A.D. •' 1 7. v I® 51.75" 1811 6" 5 61_01r 12 6,r 1 27 071, O--------------------------------------------- - - - - -� PLAN MK lit-1 irn nn n nr- 'A" 4 8" D.I.P SERVICE LINE CONC. BLOCK SUPPORT --- /" UNDER CHECK AND GATE SECTION "A-A" METER VAULT DETAIL N.T.S. CONCRETE ANCHORS AT CONCRETE ANCHOR ALL 90' BENDS AT ALL TEES MINIMUM COMPRESIVE STRENGTH OF 2,500 PSI • • °. /-AT 28 DAYS (All concrete . Anchors) PIPE TRENCH UNDISTURBED GROUND MIN. 12" CONCRETE ANCHORS AT ALL •• a' CONCRETE ANCHORS AT ALL 45', 22 1/2 & 11 1/4' BENDS PUGS AND CAPS IN TEES, 'a.. CROSSES, & AT END OF MAINS, REGARLESS OF TYPE OF JOINT. 4 . CONCRETE ANCHORS AT WYE z S 41/2 Ht ORh?Do whichever is greater CONCRETE THRUST BLOCK BEARINGS ON UNDISTURBED SOIL OF TRENCH WALL IN SQ. FEET AT 100 PSI INTERNAL PRESSURE PIPE SIZE DEAD HORIZONTAL BEND *2. 90' 45' 22 1/2* 11 1/4' 8" X 4" MECHANICAL JOINT TEE END 6" 2 3 1.5 1 1 8" 4 5 3 1.5 1 12" 7 10 6 3 2 16" 12 17 10 5 3 20" 18 26 14 7 4 24" 26 38 20 10 5 NOTES: 1. ABOVE BEARING AREAS ARE BASED ON AN ALLOWABLE SOIL- BEARING PRESSURE OF 2000 LBS /SQ.FT. AND MAY BE VARIED BY THE ENGINEER IF OTHER SOIL CONDITIONS ARE ENCOUNTERED IN THE FIELD. 2. SIZES LARGER THAN 24" MUST HAVE PIPE THRUST CALCULATED AND SUBMITTED FOR APPROVAL. 3. PLASTIC SHEET TO BE USED BETWEEN PIPE & ANCHOR, PLUGS CAPS, OR HUBS. 4. RESTRIANED JOINTS MAY BE USED OR ADDED TO CONCRETE ANCHOR IF HORIZONTAL PRESSURE IS GREATER THAN ALLOWABLE SOIL BEARING PRESSURE AS DETERMINE BY THE ENGINEER. (6" THRU 20 "). RESTRAINED JOINTS SHALL BE USED IN ADDITION TO CONCRETE ANCHOR FOR 24" AND LARGER. 5. CONCRETE ANCHORS ARE REQUIRED ON TAPPING SLEEVES PRIOR TO TAPPING. CONCRETE ANCHORS N.T.S. ROCK ^ CONC. BLOCK SUPPORT UNDER METERS AND STRAINER. - -i NO. DESCRIPTION *1. 6" ROCKWELL MODEL W -2000 DR OLIVERIO SANCHEZ,P.E. MAGNETIC DRIVE, FLANGED, TURBO -METER *2. 6" ROCKWELL STRAINER, OR APPROVED EQUAL *3. ' 2" METER 4. 8" X 4" MECHANICAL JOINT TEE 5. 8" X 6" REDUCER, PLAIN ENDS, AND TIE RODS 6. 6" MECHANICAL JOINT GATE VALVE 7. 6" DUCTILE IRON PIPE 8. 6" FLANGED COUPLING ADAPTER 9. 6" FLANGED DUCTILE IRON PIPE 10. 2" CORPORATION STOP 11. 6" DETECTOR CHECK VALVE c W/O METER TRIM 12. 6" FLANGED GATE VALVE 13. 4" CONNECTOR, PLAIN END AND FLANGED END, AND TIE RODS 14. 4" X 2" REDUCING FLANGE 15. 2" GALV. STEEL NIPPLE 16. 2" GALV. STEEL 90 DEGREE BEND 17. 2" GALV. STEEL PIPE 18. 2" GALV. STEEL GATE VALVE, NRS 19. 2" GALV. STEEL SHORT NIPPLE 20. 2" COMPRESSION COUPLING 21. 2" CHECK VALVE 22. VALVE BOX, RISER AND SLAB PER MDW &SAD STD. WS 1.0 23. 6" X 4" MECHANICAL JOINT TEE 24. 6" MECHANICAL JOINT GATE VALVE 25. PRECAST CONCRETE VAULT AND COVER, W -666 A BROOKS PRODUCTS, IN ACCORDANCE WITH MIAMI -DADE C8 ®07 28 OF 39 WATER AND SEWER AUTHORITY DEPARTMENT SPECIFICATIONS. 26. 4'X4' PRECAST CONCRETE SECTIONAL METER VAULT AND COVER, WS 2.20 BROOKS PRODUCTS, IN ACCORDANCE WITH MIAMI -DADE WATER AND SEWER AUTHORITY DEPARTMENT SPECIFICATIONS. 27. GUARD POST 4 "0 STEEL PIPE FILLED WITH CONCRETE PAINTED WITH TRAFFIC PAINT CODE F -2 (YELLOW). 28. 6" CONCRETE SLAB WITH 1#4 BAR CONTINUOUS ALL AROUND, 3" CLEAR FROM EDGE. * TO BE INSTALLED BY M- D.W.A.S.D OS & Y GATE VALVES PROPERTY COUNTY RESPONSI ..,.,VER) OS & Y GATE VALVES GATE VALVE 1 3/4" TIE RODS (TYPICAL) 2 COATS KOPPERS 300 '•:K;;i: OR EQUAL. ►� SEE NOTE #5 MIN. 187, NO JOINTS MECHANICAL THRUST BLOCKS BETWEEN VALVE AND JOINT FITTING (TYPICAL) 90° FITTING. 1. ALL PIPE AND FITTINGS SHALL BE DUCTILE IRON CEMENT LINED WITH CEMENT LINED DUCTILE IRON FLANGE FITTINGS FOR ABOVE GROUND USE MECHANICAL JOINT SHALL BE USED UNDERGROUND. 2. CERTIFICATION OF PROPER INSTALLATION AND OPERATION WILL BE REQUIRED FROM A CERTIFIED BACKFLOW PREVENTION TECHNICIAN PRIOR TO WATER MAIN ACCEPTANCE BY P.B.C.W.U.D. 3. THE DETECTOR CHECK VALVE ASSEMBLY SHALL BE ON THE APPROVED LIST OF THE UNIVERSITY OF SOUTHERN CALIFORNIA. 4. THE PROPERTY OWNER SHALL BE RESPONSIBLE FOR THE PROPER OPERATION, MAINTENANCE AND TESTING OF THE DOUBLE CHECK VALVE ASSEMBLY. 5. WHEN FIRE LINE LENGTH IS OVER ONE PIPE LENGTH, LINE SHALL BE TERMINATED WITH A GATE VALVE. DOUBLE DETECTOR CHECK VALVE N.T.S. a 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 L I�1 11000 N I16 I l �llo� NATIONAL CITY CENTER P.O. BOX 7033 INDIANAPOLIS, IN 46207 (317) 63fr1600 THIS ::] COI RAS COMPANY 1111 Lincoln Road Mall .ite 510 Miami Beach, FL. 33139 (305) 532-0433 P�-. E4 H G F I JV a� �z a • � aW Jz W Lu O cc � g ca is k u s I � ARCHIT& -rM • WGRIMMM N AMMG • INMOA DESIGN E MIAMI, h LUKIUA JJ 14J (305) 666 -5474 A.A.C. 000404 OLIVERIO SANCHEZ,P.E. CIVIL ENGINEER FL.REG.NO 44771 D_ JOB.. :; .•� 7> _ o ISSUE DATE 8 -7 -96 _Cq c :S BID SET REVISION DATE _ O - Z B _ U w - O ' -� _ Q CADD FILE NAME C8 -07 DRAWING TITLE WATER SHEET NUMBER A C8 ®07 28 OF 39