07-780-033PLUMBING NOTES: i . ALL WORKMANSHIP AND MATERIAL_ SHALL BE IN STRICT ACCORDANCE WITH APPLICABLE LOCAL CODES, RULES AND ORDINANCES. 2. CONTRACTOR SHALT_ VISIT THE JOB SITE AND THOROUGHLY FAMILIARIZE HIMSELF WITH ALL EXISTING CONDITIONS. 3. ALL MATERIAL SHALL BE NEW. 4. ALL WORK SHALL BE PERFORMED BY A LICENSED PLUMBING CONTRACTOR IN A FIRST CLASS WORKMANLIKE MANNER. THE COMPLETED SYSTEM SHALL BE FULLY OPERATIVE. 5. ALL EXCAVATION AND BACKFILL AS REQUIRED FOR THIS PHASE OF CONSTRUCTION SHALL BE A PART OF THIS CONTRACT. 6. REQUIRED INSURANCE SHALL BE PROVIDED BY IHE CONTRACTOR FOR PROTECTION AGAINST PUBLIC LIABILITY AND PROPERTY DAMAGE FOR THE DURATION OF WORK. 7. CONTRACTOR SHALL SECURE AND PAY FOR ALL PERMITS, FEES, INSPECTION AND TESTS. 8. DRAWINGS ARE DIAGRAMMATIC. DO NOT SCALE FOR THE EXACT LOCATION OF FIXTURES, PIPING, EQUIPMENT, ETC. 9. ALL WORK SHALL BE COORDINATED WITH OTHER TRADES TO AVOID INTERFERENCE WITH THE PROGRESS OF CONSTRUCTION. REPORT ANY DISCREPANCY TO ENGINEER /ARCHITECT PRIOR TO BEGINING CONSTRUCTION. 10. VERIFY LOCATION, SIZE, INVERTS OF ALL EXISTING UTILH IFS PRIOR TO BEGINING CONSTRUCTION. ADVICE ENGINES --R OF ANY DISCREPANCIES. 11. WATER PIPING SHALL BE TYPE "L" COPPER FOR 2" AND UNDER AND TYPE "K" COPPER FOR 2 -1/2" AND ABOVE, ALL UNDERGROUND WATER PIPING SHALL BE TYPE "K" COPPER. 12. SOIL, WASTE, VENT AND RAINWATER PIPING SHALL BE SCHEDULE 40 PVC PIPE. 13. AIR CONDITIONING CONDENSATE DRAIN PIPING SHALL BE SCHEDULE 40 PVC PIPE WITH 3/4" ARMAFLEX INSULATION. 14. ALL FIXTURES MUST BE PROVIDED WITH READILY ACCESSIBLE STOPS AND APPROPIATELY MARKED ACCESS PANELS. COORDINATE LOCATIONS WITH GENERAL CONTRACTOR PRIOR TO INSTALLATION. 15. FURNISH AND INSTALL APPROVED AIR CHAMBERS, AT EACH PLUMBING FIXTURE AND P.D.I. APPROVED SHOCK ARRESTORS ON MAIN LINES ON RISERS. ( Z -1700 SERIES ) 16. DIELECTRIC COUPLINGS ART_ REQUIRED BETWEEN ALL DISSIMILAR METAL IN PIPING AND EQUIPMENT CONNECTIONS. 17. ISOLATE COPPER PIPE FROM HANGER OR SUPPORTS WITH ISOLATOR PAD (HAIR FELT LINING). 18 ALL- FIRE RATED FLOOR AND WALL PENETRATIONS SHALL BE PROPERLY PROTECTED FROM FIRE, SMOKE AND WATER PENETRATION BY FILLING VOIDS BETWEEN PIPE AND WALL /FLOOR SI -FEVES WITH FIRE RATED FOAM, CHASE TECHNOLOGY CORP. - CTC PR -855 OR 3M CP -25 CAULKING OR 303 PUTTY, TO ACHIEVE SAME RATING AS GYALLS OR FLOORS. 19. CONTRACTOR SHALL GUARANTEE ALL MATERIALS AND WORKMANSHIP FREE_ FROM DEFECTS FOR A PERIOD OF NOT LESS THAN ONE (1) YEAR FROM DATE OF ACCEPTANCE BU OWNER. CORRECTION OF ANY DEFECTS SHALL BE COMPLETED WITHOUT ADDITIONAL CHARGE AND SHALL INCLUDE REPLACEMENT OR REPAIR OF ANY 0HIFR PHASE OF THE INSTALLATION WHICH MAY HAVE BEEN DAMAGED. 20. PROVIDE ACCESS PANELS FOR ALL CONCEALED VALVES AND ALL WATER HAMMER ARRESTERS. ACCESS PANELS IN RATED WALLS MUST MAINTAIN THE SAME RATING AND MUST MATCH THE FINISH OF THE WALL IN WHICH IT IS INSTALLED. 21. PROVIDE CHROME PLATED COMBINATION COVER PLATE AND CLEANOUT PLUG OR ACCESS PANEL FOR ALL WALL CLEANOUTS - ZURN ZS-1469 SERIES C.O. OR APPROVED ACCESS PANEL. 22. NO COMBUSTIBLE MATERIAL TO BE USED IN MECHANICAL ROOMS OR IN CEILING SPACES WHERE USED AS RETURN AIR PLENUMS. 23. MINIMUM SLOPE FOR PIPES 2" AND SMALLER SHALL BE 1/4" PER I -F., FOR PIPES 3" AND ABOVE MINIMUM SLOPE SHALL BE 1/8" PER LF. 24. INSULATE ALL HOT WATER. 3/4" THICK ARMAFLEX. 25. DRAINS SHALL BE AS FOLLOWS: (ZURN, U.O.N.) ROOF DRAINS (JOSAM, #26000) FLOOR DRAINS ( #ZN415 -P -6B) EWC BI -LEVEL (SF2500 WITH SF0140) 26. ALL SHOWER VALVES SHALL BE ANTI - SCALD/ PRESSURE BALANCING. 27. ALL PLUMBING FIXTURES SHALL MEET STATE AND LOCAL CODES. 28. INSULATE ALL HOT WATER, HOT WATER RETURN, RAINWATER, CON- DENSATE LINES, EXHAUST LINES ABOVE (;TRADE AND FIRST 8' -0" OF COLD WATER LINE FROM WATER HEATER /BOILER AS FOLLOWS: CW, HW SUPPLY AND RETURN - 1" THICK PREFORMED FIBERGLASS PIPE INSULATION W/ FACTORY JACKET. HORIZONTAL STORM DRAIN PIPING - 1 1/2" THICK PREFORMED FIBERGLASS PIPE INSULATION W/ FACTORY JACKET. CONDENSATE PIPING - 3/4" ARMAFLEX PREFORMED. EXHAUST PIPE - 3" THICK CALCIUM SILICATE BLOCK INSULATION W/1200 F. STEVENS CLASS CLOTH WRAP. 29. PROVIDE 1/2" TRAP PRIMER LINE FOR ALL FLOOR DRAINS FROM THE NEAREST PLUMBING FIXTURE, 30. NO WATER, SANITARY OR DRAINAGE PIPING PERMITTED IN ELECTRICAL OR ELEVATOR EQUIPMENT ROOMS.; WATER STUBBED THRU FOR ELECTRICAL GROUND AND SPRINKLER HEAD AND- PIPE W /CONTROL VALVE AS APPROVED BY LOCAL BUILDING AND FIRE DEPARTM EN IS. 31. ALL HOSE GIBBS SHALL BE CHROME PLATED 3/4" SOLID FLANGE THREADED HOSE AND LOOSE KEY W /VACUUM BREAKER - WATTS 8A, MOUNTED 2.6" ABOVE GRADE WALL HYDRANTS TO BE ZURN Z- 1350 -5 OR FINISH FLOOR UNLESS OTHERWISE NOTED. 32. INTERIOR FLOOR CLEANOUTS SHALL BE ZURN ZN1400. 33. ALL CONTROL VALVES SHALL BE TAGGED AND MARKED. A REPRODUCEABI_E DIAGRAM LOCATING ALL VALVES SHALL BE PROVIDED FOR OWNER /OPERATOR. 34. SCHEDULE 40 PVC D.W.V. MAY BE USED ON SANITARY, STORMDRAINS, AND CONDENSATE LINES WHERE LOCAL CODE AND ORDINANCES WILL ALLOW. 35. ALL METALLIC PIPING, FITTINGS AND HANGERS EXPOSED TO CORROSIVE CONDITIONS SHALL HAVE A PROTECTIVE COATING THAT RESIST CORROSION. HOT WATER RETURN 36. ALL FIRE MAINS, HOT & COLD WATER PIPES, PIPING, STORM DRAIN AND CONDENSATE PIPING AND GAS PIPING SHALL HAVE IDENTIFICATION AND FLOW DIRECTIONS BANDS. 37. CONTRACTOR SHALL KEEP A SET OF AS GUILTS DWG. ON THE JOB SITE Ar ALL TIMES AND DELIVER A SET OF -UP TO DATE AS- GUILTS TO THE ENGINEER AND OWNER AT THE COMPLETION OF THE PROJECT. J_ A/C UNIT AUXILIARY DRAIN PAN - 3/,'4- AUXILIARY DRAIN LINE TO SItUB THRU CLG. OVER SINK W/ CHIROME ESCUTCHEON PLATE (WAINTAIN PITCH) ROOF STRUCTURE //- UNION CLEANOUr PLUG TRAP CONDENSATE DRAIN, INSULATED CEILING CONDENSATE TRAP DETAIL N.T.S. PROVIDE WEATHER PROOF CAP I TURN HEAD PIPE DOWN INTO STACK FOR FUTURE TENANT AREAS SKEET LEAD FLASHING MOP IN W/ ROOFING MATERIAL -T-,__ ROOFING \ \-- ROOF CUINSTRUCTIUN `- SLEEVE ROOF CUINSTRUCTIUN ASS REQUIRED VENT STACK NI]L ANY VENT FIRE WITHIN 10' -0' OF ANY DOUR, WINDOW, OR EXHAUST OPENINGS SHALL EXTEND NOT LESS THAN 3' -0' ABOVE SUCH VENT T'HRU ROOF DETAIL, N.T.S. // �'4y0• OtJ' orb d�b� PLUMBING SYMBOLS LyO� AO ;' 0'6 doe 8c ABBREVIATIONS 5 - - - -5 HUT WATER PIPE IIW S - -i COLD WATER PIPE CW t- - - - --i HOT WATER RECIRCULAING HWR Q WATER HAMMER ARRESTOR WHA n AIR CHAMBER NOT IN 5 - -N -S CHECK VALVE CV S i HOSE BIBB W/ VACUUM BREAKER & HB SHUT -OFF VALVE S S GATE VALVE {SHUT -OFF VALVE) SOV � -SAN -'S SANITARY LINE SAN S -Co -S CONDENSATE LINE CD 5--- - - - --5 VENT LINE 5-- -PLT -; PRESSURE RELIEF P &T S-DP -i DRAIN PAN DP i'- ESAN --4 EXISTING SANITARY LINE ESAN S- -ECV - -S EXISTING COLD WATER PIPE ECW WATER CLOSET WC VENT THRU ROOF VTR LAVATORY LAV JANITOR'S SINK JS FLOOR DRAIN FD ELECTRIC WATER COOLER EWC ABOVE FINISH FLOOR A.F.F. BELOW FINISH FLOOR B.F.F. FLOUR CLEANOUT FCO CLEANUUT TO GRADE CTG WALL CLEANOUT WCO FIXTURE UNITS FU EXISTING FLOOR CLEAN OUT EFCO CONNECT NEW PIPE INTO EXISTING NUTD NOT ALL SYMBULS & ABBREVIATIONS APPLY TO THIS JOB, J_ A/C UNIT AUXILIARY DRAIN PAN - 3/,'4- AUXILIARY DRAIN LINE TO SItUB THRU CLG. OVER SINK W/ CHIROME ESCUTCHEON PLATE (WAINTAIN PITCH) ROOF STRUCTURE //- UNION CLEANOUr PLUG TRAP CONDENSATE DRAIN, INSULATED CEILING CONDENSATE TRAP DETAIL N.T.S. PROVIDE WEATHER PROOF CAP I TURN HEAD PIPE DOWN INTO STACK FOR FUTURE TENANT AREAS SKEET LEAD FLASHING MOP IN W/ ROOFING MATERIAL -T-,__ ROOFING \ \-- ROOF CUINSTRUCTIUN `- SLEEVE ROOF CUINSTRUCTIUN ASS REQUIRED VENT STACK NI]L ANY VENT FIRE WITHIN 10' -0' OF ANY DOUR, WINDOW, OR EXHAUST OPENINGS SHALL EXTEND NOT LESS THAN 3' -0' ABOVE SUCH VENT T'HRU ROOF DETAIL, N.T.S. // �'4y0• OtJ' orb d�b� LyO� AO ;' 0'6 doe 12 "x12 "x8" POURED CONIC. BLOCK WHEN CLEANOUT IS - NOT IN PAVED AREA 2 -WAY, CLEAN -OUT AT GRADE ZURN 2N -1400 CLEAN -OUT COVER 07 sp ' 10�'cDr .od �os.�.ot�io; -SAME SIZE AS SEWER - MAX. SIZE 4" 1 -WAY, INTERIOR CLEAN OUT 03ROOKS TRAFFIC (SOX ODY #1 -RT COVER 25c B (TYP.) \ SAME SIIZ SEIVER - SIZE 4 %T LAVATORY - J.R. SMITH # 2698 WATER SAVER TRAP PRIMER CLE ANOUT PLUG \ FINISHED FLOOR FINISHED WALL FLOOR DRAIN TR,p P PRIMER DIAGRAM. N.T.S. PAVING 12" -3/4" WASH ROCK 2 -WAY, CLEAN -OUT AT PARKING AREA 12 "x12 "x8" POURED CONC. BLOCK WHEN CLEANOUT IS Nor IN PAVED AREA •rvPiCAL CLEAWOUT DETAILS, N.T.S. �-- STAINLESS STEEL COVER SCREWED TO THREADED C.O. PLUG FACE OF WALL WALL -TYPE CLEAN -OUT IFINISH GRADE -SAME SIZE AS SEWER - MAX. SIZE 4" LONG SWEEP. USE SHORT SWEEP WHERE REQUIRES 1 -WAY, CLEAN -OUT AT GRADE REMOVABLE T HANDLE 3/4' NOSE THRE �-- ---- -- H11I ; I 3/4' CONNECTION J LESS FLAKE WHERE' PIPING OUGH CHROME PLATED - VACUUM BREAKER (VANDAL PRUUF) HOSE 1 BBB DETAIL N.T.S. IIIERMAL L) 3/4" BEAT TRAP HOT SYSI P & T BELIE VALVE ELECTRIC W HEATER DRAIN VALV .. COLD WATER SUPPLY SHUT -OFF VALVE HEAT TRAP WATER SUPPLY TO HEATER.' P & T RELIEF LINE FULL SIZE ,-3/4" PR LINE TO OUTSIDE, TERMINATE POINTING DOWN 6` ABOVE GRADE. - 3Ox3Ox3 GALVANIZED DRAINPAN L IN DP LINE TO OUTSIDE, IERMI MINAIE POINTING DOWN 6" ABOVE GRADE. WATER HEATER DETAIL. N.T.S. HANGER ROD HANGER ROD LOCKING NUT SUPPORT NUT - SUPPORT NUT HEAVY DUTY CLEVIS HANGER - - -- -� --- -- HEAVY DUTY CLEVIS PIPE HANGER -�_ VAPOR BARRIER INSULAT1014 16 GAUGE ZINC COATED SHEET STEEL CLEVIS HAT�� LEAST 8' LONG ADDLE AT SINGLE HORIZONTAL RUNS NO VAPOR BARRIER INSULATIOtJ QLEyLS-- A6NaE& ' S[NGI E HOR ►ZONTAL R IN$• WITH VAPOR BARRIER INSULATION '.- WEB MEMBERS ONE ANGLE ON EACH .IDS C IIA14GER NUT SIDE OF WEB MEMBERS \ rr REST ON TOP OF BUTTUN CHORDS STEEL BENT STRAP 1112' JOISTS BETWEEN PANEL 3/16' OVER VERT. POINTS, SIZE FOR LOAD LESS OF ANGLES--- BUTTUN CHORDS OF STEEL JOTS SIfEL JOLSL HEA`, DUTY CONCRETE STE[ INSERT 4'ITH r ELUI AIED STRAP t.` •q. .• ". i BEAM �• �j�����1(1 3 3' i BEAM CLAMP INSERT NUT 1 MANGER D f CUNCR f' �� STEEL BEAM = HANGER ROD. SIZE AS REG. PIPE SUPPORT DETAIL. N.T.S, (FOR SANITARY & WATER PIPING) .t AAA t ARC' LIW4SE AR)' 07..6 1 VON'# N Fes - U_ U-, �I- `4- C\ O (D s 0u �0 CU - 0 c) -2 �+ N Q) ai E 0 r. u .2, 0 I_ a 0 0 (D QO r� r-- QO U(�)� cD O V/ u` o w U ' 2 II Lf� 14 1 c a� L O �(D U U I . ARCH. LICENSE AR 0767 job no. 9903 date. 01 -28 -07 scale. As Shown drawn by A G. reviewed by. C.M issued. 01-28-07 sheetno. p - \'� b