07-780-033PLUMBING NOTES:
i . ALL WORKMANSHIP AND MATERIAL_ SHALL BE IN STRICT
ACCORDANCE WITH APPLICABLE LOCAL CODES, RULES AND
ORDINANCES.
2. CONTRACTOR SHALT_ VISIT THE JOB SITE AND THOROUGHLY
FAMILIARIZE HIMSELF WITH ALL EXISTING CONDITIONS.
3. ALL MATERIAL SHALL BE NEW.
4. ALL WORK SHALL BE PERFORMED BY A LICENSED PLUMBING
CONTRACTOR IN A FIRST CLASS WORKMANLIKE MANNER. THE
COMPLETED SYSTEM SHALL BE FULLY OPERATIVE.
5. ALL EXCAVATION AND BACKFILL AS REQUIRED FOR THIS PHASE
OF CONSTRUCTION SHALL BE A PART OF THIS CONTRACT.
6. REQUIRED INSURANCE SHALL BE PROVIDED BY IHE CONTRACTOR
FOR PROTECTION AGAINST PUBLIC LIABILITY AND PROPERTY
DAMAGE FOR THE DURATION OF WORK.
7. CONTRACTOR SHALL SECURE AND PAY FOR ALL PERMITS, FEES,
INSPECTION AND TESTS.
8. DRAWINGS ARE DIAGRAMMATIC. DO NOT SCALE FOR THE EXACT
LOCATION OF FIXTURES, PIPING, EQUIPMENT, ETC.
9. ALL WORK SHALL BE COORDINATED WITH OTHER TRADES TO
AVOID INTERFERENCE WITH THE PROGRESS OF CONSTRUCTION.
REPORT ANY DISCREPANCY TO ENGINEER /ARCHITECT PRIOR TO
BEGINING CONSTRUCTION.
10. VERIFY LOCATION, SIZE, INVERTS OF ALL EXISTING
UTILH IFS PRIOR TO BEGINING CONSTRUCTION. ADVICE
ENGINES --R OF ANY DISCREPANCIES.
11. WATER PIPING SHALL BE TYPE "L" COPPER FOR 2" AND UNDER
AND TYPE "K" COPPER FOR 2 -1/2" AND ABOVE, ALL
UNDERGROUND WATER PIPING SHALL BE TYPE "K" COPPER.
12. SOIL, WASTE, VENT AND RAINWATER PIPING SHALL BE SCHEDULE
40 PVC PIPE.
13. AIR CONDITIONING CONDENSATE DRAIN PIPING SHALL BE
SCHEDULE 40 PVC PIPE WITH 3/4" ARMAFLEX INSULATION.
14. ALL FIXTURES MUST BE PROVIDED WITH READILY ACCESSIBLE
STOPS AND APPROPIATELY MARKED ACCESS PANELS.
COORDINATE LOCATIONS WITH GENERAL CONTRACTOR PRIOR TO
INSTALLATION.
15. FURNISH AND INSTALL APPROVED AIR CHAMBERS, AT EACH
PLUMBING FIXTURE AND P.D.I. APPROVED SHOCK ARRESTORS ON
MAIN LINES ON RISERS. ( Z -1700 SERIES )
16. DIELECTRIC COUPLINGS ART_ REQUIRED BETWEEN ALL
DISSIMILAR METAL IN PIPING AND EQUIPMENT CONNECTIONS.
17. ISOLATE COPPER PIPE FROM HANGER OR SUPPORTS WITH
ISOLATOR PAD (HAIR FELT LINING).
18 ALL- FIRE RATED FLOOR AND WALL PENETRATIONS SHALL BE
PROPERLY PROTECTED FROM FIRE, SMOKE AND WATER
PENETRATION BY FILLING VOIDS BETWEEN PIPE AND
WALL /FLOOR SI -FEVES WITH FIRE RATED FOAM, CHASE
TECHNOLOGY CORP. - CTC PR -855 OR 3M CP -25 CAULKING OR
303 PUTTY, TO ACHIEVE SAME RATING AS GYALLS OR FLOORS.
19. CONTRACTOR SHALL GUARANTEE ALL MATERIALS AND
WORKMANSHIP FREE_ FROM DEFECTS FOR A PERIOD OF NOT LESS
THAN ONE (1) YEAR FROM DATE OF ACCEPTANCE BU OWNER.
CORRECTION OF ANY DEFECTS SHALL BE COMPLETED WITHOUT
ADDITIONAL CHARGE AND SHALL INCLUDE REPLACEMENT OR
REPAIR OF ANY 0HIFR PHASE OF THE INSTALLATION WHICH MAY
HAVE BEEN DAMAGED.
20. PROVIDE ACCESS PANELS FOR ALL CONCEALED VALVES AND ALL
WATER HAMMER ARRESTERS. ACCESS PANELS IN RATED WALLS
MUST MAINTAIN THE SAME RATING AND MUST MATCH THE FINISH
OF THE WALL IN WHICH IT IS INSTALLED.
21. PROVIDE CHROME PLATED COMBINATION COVER PLATE AND
CLEANOUT PLUG OR ACCESS PANEL FOR ALL WALL CLEANOUTS -
ZURN ZS-1469 SERIES C.O. OR APPROVED ACCESS PANEL.
22. NO COMBUSTIBLE MATERIAL TO BE USED IN MECHANICAL ROOMS
OR IN CEILING SPACES WHERE USED AS RETURN AIR PLENUMS.
23. MINIMUM SLOPE FOR PIPES 2" AND SMALLER SHALL BE 1/4" PER I -F.,
FOR PIPES 3" AND ABOVE MINIMUM SLOPE SHALL BE 1/8" PER LF.
24. INSULATE ALL HOT WATER. 3/4" THICK ARMAFLEX.
25. DRAINS SHALL BE AS FOLLOWS: (ZURN, U.O.N.)
ROOF DRAINS (JOSAM, #26000)
FLOOR DRAINS ( #ZN415 -P -6B)
EWC BI -LEVEL (SF2500 WITH SF0140)
26. ALL SHOWER VALVES SHALL BE ANTI - SCALD/ PRESSURE BALANCING.
27. ALL PLUMBING FIXTURES SHALL MEET STATE AND LOCAL CODES.
28. INSULATE ALL HOT WATER, HOT WATER RETURN, RAINWATER, CON-
DENSATE LINES, EXHAUST LINES ABOVE (;TRADE AND FIRST 8' -0"
OF COLD WATER LINE FROM WATER HEATER /BOILER AS FOLLOWS:
CW, HW SUPPLY AND RETURN - 1" THICK PREFORMED
FIBERGLASS PIPE INSULATION W/ FACTORY JACKET.
HORIZONTAL STORM DRAIN PIPING - 1 1/2" THICK PREFORMED
FIBERGLASS PIPE INSULATION W/ FACTORY JACKET.
CONDENSATE PIPING - 3/4" ARMAFLEX PREFORMED.
EXHAUST PIPE - 3" THICK CALCIUM SILICATE BLOCK
INSULATION W/1200 F. STEVENS CLASS CLOTH WRAP.
29. PROVIDE 1/2" TRAP PRIMER LINE FOR ALL FLOOR DRAINS FROM
THE NEAREST PLUMBING FIXTURE,
30. NO WATER, SANITARY OR DRAINAGE PIPING PERMITTED IN
ELECTRICAL OR ELEVATOR EQUIPMENT ROOMS.; WATER STUBBED
THRU FOR ELECTRICAL GROUND AND SPRINKLER HEAD AND- PIPE
W /CONTROL VALVE AS APPROVED BY LOCAL BUILDING AND FIRE
DEPARTM EN IS.
31. ALL HOSE GIBBS SHALL BE CHROME PLATED 3/4" SOLID FLANGE
THREADED HOSE AND LOOSE KEY W /VACUUM BREAKER - WATTS
8A, MOUNTED 2.6" ABOVE GRADE WALL HYDRANTS TO BE ZURN
Z- 1350 -5 OR FINISH FLOOR UNLESS OTHERWISE NOTED.
32. INTERIOR FLOOR CLEANOUTS SHALL BE ZURN ZN1400.
33. ALL CONTROL VALVES SHALL BE TAGGED AND MARKED. A
REPRODUCEABI_E DIAGRAM LOCATING ALL VALVES SHALL BE
PROVIDED FOR OWNER /OPERATOR.
34. SCHEDULE 40 PVC D.W.V. MAY BE USED ON SANITARY, STORMDRAINS,
AND CONDENSATE LINES WHERE LOCAL CODE AND ORDINANCES
WILL ALLOW.
35. ALL METALLIC PIPING, FITTINGS AND HANGERS EXPOSED TO
CORROSIVE CONDITIONS SHALL HAVE A PROTECTIVE COATING
THAT RESIST CORROSION. HOT WATER RETURN
36. ALL FIRE MAINS, HOT & COLD WATER PIPES,
PIPING, STORM DRAIN AND CONDENSATE PIPING AND GAS PIPING
SHALL HAVE IDENTIFICATION AND FLOW DIRECTIONS BANDS.
37. CONTRACTOR SHALL KEEP A SET OF AS GUILTS DWG. ON THE JOB
SITE Ar ALL TIMES AND DELIVER A SET OF -UP TO DATE AS- GUILTS
TO THE ENGINEER AND OWNER AT THE COMPLETION OF THE PROJECT.
J_
A/C UNIT
AUXILIARY DRAIN PAN -
3/,'4- AUXILIARY DRAIN LINE TO
SItUB THRU CLG. OVER SINK W/
CHIROME ESCUTCHEON PLATE
(WAINTAIN PITCH)
ROOF STRUCTURE
//-
UNION
CLEANOUr PLUG
TRAP
CONDENSATE DRAIN,
INSULATED
CEILING
CONDENSATE TRAP DETAIL
N.T.S.
PROVIDE WEATHER PROOF CAP I TURN HEAD PIPE DOWN INTO STACK
FOR FUTURE TENANT AREAS
SKEET LEAD FLASHING MOP IN
W/ ROOFING MATERIAL -T-,__
ROOFING
\ \-- ROOF CUINSTRUCTIUN
`- SLEEVE ROOF CUINSTRUCTIUN
ASS REQUIRED
VENT STACK
NI]L
ANY VENT FIRE WITHIN 10' -0'
OF ANY DOUR, WINDOW, OR EXHAUST
OPENINGS SHALL EXTEND NOT LESS
THAN 3' -0' ABOVE SUCH
VENT T'HRU ROOF DETAIL,
N.T.S.
// �'4y0• OtJ'
orb d�b�
PLUMBING SYMBOLS
LyO� AO ;'
0'6 doe
8c ABBREVIATIONS
5 - - - -5
HUT WATER PIPE
IIW
S - -i
COLD WATER PIPE
CW
t- - - - --i
HOT WATER RECIRCULAING
HWR
Q
WATER HAMMER ARRESTOR
WHA
n
AIR CHAMBER
NOT IN
5 - -N -S
CHECK VALVE
CV
S i
HOSE BIBB W/ VACUUM BREAKER &
HB
SHUT -OFF VALVE
S S
GATE VALVE {SHUT -OFF VALVE)
SOV
� -SAN -'S
SANITARY LINE
SAN
S -Co -S
CONDENSATE LINE
CD
5--- - - - --5
VENT LINE
5-- -PLT -;
PRESSURE RELIEF
P &T
S-DP -i
DRAIN PAN
DP
i'- ESAN --4
EXISTING SANITARY LINE
ESAN
S- -ECV - -S
EXISTING COLD WATER PIPE
ECW
WATER CLOSET
WC
VENT THRU ROOF
VTR
LAVATORY
LAV
JANITOR'S SINK
JS
FLOOR DRAIN
FD
ELECTRIC WATER COOLER
EWC
ABOVE FINISH FLOOR
A.F.F.
BELOW FINISH FLOOR
B.F.F.
FLOUR CLEANOUT
FCO
CLEANUUT TO GRADE
CTG
WALL CLEANOUT
WCO
FIXTURE UNITS
FU
EXISTING FLOOR CLEAN OUT
EFCO
CONNECT NEW PIPE INTO EXISTING
NUTD
NOT ALL
SYMBULS & ABBREVIATIONS APPLY TO
THIS JOB,
J_
A/C UNIT
AUXILIARY DRAIN PAN -
3/,'4- AUXILIARY DRAIN LINE TO
SItUB THRU CLG. OVER SINK W/
CHIROME ESCUTCHEON PLATE
(WAINTAIN PITCH)
ROOF STRUCTURE
//-
UNION
CLEANOUr PLUG
TRAP
CONDENSATE DRAIN,
INSULATED
CEILING
CONDENSATE TRAP DETAIL
N.T.S.
PROVIDE WEATHER PROOF CAP I TURN HEAD PIPE DOWN INTO STACK
FOR FUTURE TENANT AREAS
SKEET LEAD FLASHING MOP IN
W/ ROOFING MATERIAL -T-,__
ROOFING
\ \-- ROOF CUINSTRUCTIUN
`- SLEEVE ROOF CUINSTRUCTIUN
ASS REQUIRED
VENT STACK
NI]L
ANY VENT FIRE WITHIN 10' -0'
OF ANY DOUR, WINDOW, OR EXHAUST
OPENINGS SHALL EXTEND NOT LESS
THAN 3' -0' ABOVE SUCH
VENT T'HRU ROOF DETAIL,
N.T.S.
// �'4y0• OtJ'
orb d�b�
LyO� AO ;'
0'6 doe
12 "x12 "x8"
POURED CONIC.
BLOCK WHEN
CLEANOUT IS
-
NOT IN
PAVED AREA
2 -WAY, CLEAN -OUT
AT GRADE
ZURN 2N -1400
CLEAN -OUT COVER
07 sp ' 10�'cDr .od �os.�.ot�io;
-SAME SIZE AS
SEWER - MAX.
SIZE 4"
1 -WAY, INTERIOR
CLEAN OUT
03ROOKS TRAFFIC
(SOX ODY #1 -RT COVER
25c B
(TYP.) \
SAME SIIZ
SEIVER -
SIZE 4 %T
LAVATORY -
J.R. SMITH
# 2698
WATER SAVER
TRAP PRIMER
CLE ANOUT PLUG
\
FINISHED FLOOR FINISHED WALL
FLOOR DRAIN
TR,p P PRIMER DIAGRAM.
N.T.S.
PAVING
12"
-3/4" WASH
ROCK
2 -WAY, CLEAN -OUT
AT PARKING AREA
12 "x12 "x8"
POURED CONC.
BLOCK WHEN
CLEANOUT IS
Nor IN
PAVED AREA
•rvPiCAL CLEAWOUT DETAILS,
N.T.S.
�-- STAINLESS STEEL COVER
SCREWED TO THREADED
C.O. PLUG
FACE OF WALL
WALL -TYPE
CLEAN -OUT
IFINISH GRADE
-SAME SIZE AS
SEWER - MAX.
SIZE 4"
LONG SWEEP. USE SHORT
SWEEP WHERE REQUIRES
1 -WAY, CLEAN -OUT
AT GRADE
REMOVABLE T
HANDLE
3/4' NOSE THRE
�-- ---- --
H11I ; I
3/4' CONNECTION
J LESS FLAKE WHERE'
PIPING
OUGH CHROME PLATED
- VACUUM BREAKER
(VANDAL PRUUF)
HOSE 1 BBB DETAIL
N.T.S.
IIIERMAL L)
3/4" BEAT
TRAP
HOT
SYSI
P & T BELIE
VALVE
ELECTRIC W
HEATER
DRAIN VALV
..
COLD WATER SUPPLY
SHUT -OFF VALVE
HEAT TRAP
WATER SUPPLY
TO HEATER.'
P & T RELIEF LINE
FULL SIZE
,-3/4" PR LINE TO OUTSIDE,
TERMINATE POINTING DOWN
6` ABOVE GRADE.
- 3Ox3Ox3 GALVANIZED
DRAINPAN
L IN DP LINE TO OUTSIDE,
IERMI MINAIE POINTING DOWN
6" ABOVE GRADE.
WATER HEATER DETAIL.
N.T.S.
HANGER ROD
HANGER ROD LOCKING NUT
SUPPORT NUT -
SUPPORT NUT
HEAVY DUTY CLEVIS
HANGER - - -- -� --- -- HEAVY DUTY CLEVIS
PIPE HANGER
-�_
VAPOR BARRIER
INSULAT1014
16 GAUGE ZINC COATED
SHEET STEEL CLEVIS HAT�� LEAST 8' LONG
ADDLE AT
SINGLE HORIZONTAL RUNS
NO VAPOR BARRIER INSULATIOtJ QLEyLS-- A6NaE&
' S[NGI E HOR ►ZONTAL R IN$•
WITH VAPOR BARRIER INSULATION
'.- WEB MEMBERS ONE ANGLE ON EACH
.IDS
C IIA14GER NUT SIDE OF WEB MEMBERS
\ rr REST ON TOP OF
BUTTUN CHORDS STEEL
BENT STRAP 1112' JOISTS BETWEEN PANEL
3/16' OVER VERT. POINTS, SIZE FOR LOAD
LESS OF ANGLES---
BUTTUN CHORDS
OF STEEL JOTS SIfEL JOLSL
HEA`, DUTY CONCRETE
STE[ INSERT 4'ITH r
ELUI AIED STRAP
t.` •q. .• ". i BEAM
�• �j�����1(1 3
3' i BEAM CLAMP
INSERT NUT 1 MANGER D f
CUNCR f'
��
STEEL BEAM = HANGER ROD.
SIZE AS REG.
PIPE SUPPORT DETAIL.
N.T.S, (FOR SANITARY & WATER PIPING)
.t
AAA
t
ARC' LIW4SE
AR)' 07..6 1
VON'#
N Fes -
U_ U-,
�I-
`4- C\
O
(D s
0u �0
CU - 0
c) -2
�+ N
Q)
ai
E
0
r.
u
.2,
0
I_
a
0
0
(D
QO
r�
r--
QO
U(�)� cD
O V/ u`
o
w
U '
2 II
Lf�
14
1
c
a�
L
O
�(D
U
U
I .
ARCH. LICENSE
AR 0767
job no.
9903
date.
01 -28 -07
scale.
As Shown
drawn by
A G.
reviewed by.
C.M
issued.
01-28-07
sheetno.
p - \'�
b