Loading...
07-780-022GENERAL N01'ES 1. ALL MECHANICAL SYSTEMS ARE TO BE INSTALLED IN ACCORDANCE WITH ALL APPLICABLE BUILDING CODE, SECTIONS NO SE & HEIGHT RO NANCDES,DPL NS H AND SPECIFICATIONS. 2. ALL MATERIALS SHALL BE NEW AND ALL WORKMANSHIP AND MATERIALS SHALL BE IN RULES i AND ORDINANCES, D ANYAPPLICABLE EQU PMENT CODES, SF SHALL BE PRODUCT EPLACE APPROVAL, RESTORED TO ORIGINAL CONDITION. 3. THE CONTRACTOR SHALL PROVIDE ALL LABOR, MATERIALS, EQUIPMENT, ACCESS DEVICES, PANELS, CONTROL SYSTEMS, PERMITS D NECESSARY FURN SIZING ND INSTALLING G A COMPLETEOPERABLE MECHANIICAL.SYS1 FOR 4. ALL LOUVERS, GRILLES, PIPING, ETC. SHALL BE PAINTED TO MATCH ANDTRTEXTURE WITH ARCHITECT. PAINT PAINT ALL REQUIRED EXPOSSED i�NECHANICAL EQU VERIFY COLOR WITH BENJAMIN MOORE EPDXY ENAMEL 182. 5. ALL CUTTING, PATCHING, STRUCTURAL STEEL, WEATHER PROOFING, PAINTING, AND WALL OPENINGS SHALL BE BY ]HE GENERAL CONTRACTOR. 6. ALL OPENINGS IN BUILDING STRUCTURE, FOR OUCTWOFK, PIPING, ETC. TO BE 1/2" LARGER (ON ALL SIDES) THAN THE OUTSIDE DIMENSIONS. FILL VOIDS WITH FIRE RETARDANT SILICONE FOAM (I.E. CHASE -FOAM CTC PR -855 BY CHASE TECHNOLOGY CORP.). 7. PROVIDE FLEXIBLE DUCT CONNECTORS, RATED AS REQUIRED, TO ALL FANS, A/C UNITS, OR MECHANICAL EQUIPMENT. 8. 4'� PROVIDE MAINTENANCE AND OPERATION MANUAL ON ALL MECHANICAL EQUIPMENT OR SYSTEMS. PROVIDE 5 SETS OF SUBMITTALS ON ALL HVAC EQUIPMENT. SUBMITTALS SHALL HAVE A SUMMARY SHEET SHOWING ALL SCHEDULED INFORMATION. 9. HVAC CONTRACTOR WILL WARRANTY ALL MECHANICAL SYSTEMS, DUCTWORK, THERMOSTATS, AND ALL OTT -TER EQUIPMENT, PARTS AND LABOR UNDER THESE DRAWINGS AND SPECIFICATIONS FOR A PERIOD OF ONE (1) YEAR AFTER C.O. OF BUILDING. ANY REPAIRS REQUIRING SYSTEM SHUT DOWN WILL BE DONE DURING 'NON OPERATIONAL PERIODS. HVAC CONIRACTOR SHALL COORDINATE WITH ALL OTHER TRADES PRIOR TO BIDDING AND PURCHASING ANY EQUIPMENT. 10. AIR QUALITY SHOULD BE TESTED BEFORE OCCUPANCY AND SHOULD BE INSIRUMENTED AND MONITORED THEREAFIER, OR AT LEAST AT REGULAR INTERVALS 11. ALL DUCT MOUNTED SMOKE DETECTORS SHALL BE COMPATIBLE WITH THE FIRE ALARM SYSTEM.- SUBMIT SHOP DRAWINGS FOR APPROVAL. 12. PROVIDE PROPERLY SIZED REFRIGERANT PIPING BETWEEN AIR HANDLERS, AND CONDENSING UNITS, FOR EACH SPLIT TYPE AIR CONDITIONING SYSTEM REFRIGERANT PIPING SHALL BE TYPE L COPPER TUBING. • -INSULATE SUCTION LINE WITH 3/4" THICK FLEXIBLE FOAM INSULATION. MECHANICAL EQUIPMENT NOTES, 1. ALL MECHANICAL EQUIPMENT SHALL BE ART & U.L. LISTED WHERE APPLICABLE AND RATED FOR THE REQUIRED SERVICE, PRESSURES, TEMPERATURES, AND SHALL BE PROVIDED WITH ALL NECESSARY TRANSFORMERS, SEALS, VALVES, CONNECTIONS, ETC. TO FUNCTION PROPERLY. 2. PROVIDE SMOKE DETECTORS WITH ACCESS DOORS IN ALL SUPPLY AIR DUCTS FOR FANS AND AHU'S OF 2000 CFM OR ABOVE. ALL SMOKE DETECTORS SHALL BE BY ONE MANUFACTURE: COORDINATE VOLTAGE ETC. Willi ELECTRICAL CONTRACTOR AND FIRE ALARM SYSTEM BEFORE ORDERING. UPON DETECTION, SMOKE DETECTORS SHALL SHUT DOWN ASSOCIATED AIR MOVING EQUIPMENT AND ALL AIR MOVING EQUIPMENT SERVING THAT COMMON AREA. 3. PROVIDE BACKDRAFT DAMPERS ON ALL EXHAUST FNS. 4. PROVIDE A MIN. OF 10' CLEARANCE BETWEEN 0/A INTAKES AND VIR OR EXHAUST OPENINGS. 5. INDEPENDENT CONTRACTOR SHALL TEST AND BALANCE ALL MECHANICAL EQUIPMENT AIR DEVICES, EXTRACTORS, DAMPERS, AHU'S & FAN RA IES, ETC. TO PROVIDE THE DESIGN QUANTITIES AS SHOWN ON THE PLANS OR SCHEDULES. PROVIDE ]EST AND BALANCE REPORT IN ACCORDANCE WITH THE AIR BALANCE COUNCIL STANDARDS, SIGNED & SEALED BY A REGISTERED FLORIDA ENGINEER. PROVIDE FINAL BALANCING FOR ALL SYSTEMS TO SATISFACTION OF OWNER AND ENGINEER.T & B CONTRACTOR SHALL VISIT JOU E DURING DAMPERS, ETC ARE INSTALLED F OR TPROPER AND EQUIET E T DUCTS, AIR DELIVERY 6. RUN INSULATE CONDENSATE DRAINS AS PER PLUMBING DRAWINGS. 7. MOUNT ALL ROOFTOP REQUIRED BY LOCAL CODES, IALL CURBS I SHALL EXTEND HEIGHTS EXTEND 8" MIN. A13OVE FINISHED ROOF, 8, T ILL PIPING AND DUCTWORK SHALL BE SLEEVED THRU WALLS, BEAMS, SLABS, ETC, AS BAR OI5EQROSS BRACINGOAND PROVIDE WITH IHE STRUCTURAL NECESSARY T ANSIT ONSNAS REQUIR T ED 'FOR DUCTWORK INSTALLATION. 9. ALL INSULATION SHALL HAVE FIRE /SMOKE RATING LESS THAN 25/50. 10. PROVIDE MOTOR STARTERS AS FOLLOWS (UNLESS OTHERWISE RECOMMENDED BY MOTOR MANUFACTURER): A: PROVID OVERLOAD STARTING BELOW 25 HP. PHASES). 8: PROVIDE 11. ALL OUTDOOR EQUIPMENT SHALL COMPLY WITH LOCAL ZONING NOISE ORDINANCES. MIN. I�RL REQUIREMENT FT FROM THE NOT EQUIPMEND N NOISE 65 UB AS MEASURED RAND DIRECTIONS, 12. FOR ALL BELT DRIVEN AHU'S PROVIDE ADJUSTABLE PULLEYS 13 PRIOR STO TEST AND BALANCE AND GA FINAL SET AT TIR S SHALL BE IN PLACE E END OF ONE YEAR SERVICE PERIOD. D. F-AN MOTOR AND ASSEMBLY 111E FAN SHALL BE DIRECT DRIVE CENTRIFUGAL TYPE WITH A D'rNAMICALLY BALANCED WHEEL, TFIE HOUSING AND WHEEL SHALL BI. DESIGN FOR QUIET LOW VELOCITY OPERATION. THE FAN HOUSING SHALL BE REMOVABLE FROM THE UNIT WITHOUT DISCONNECTING THE SUPPLY AIR DUCT FOR SERVICING OF THE FAN MOTOR. THE FAN MOTOR SHALL BE THREE SPEED PSC TYPE. THE MOTOR SHALL BE PERMANENTLY LUBRICATED AND HAVE THERMAL OVERLOAD PROTECTION. E. B _ E �_; LK CA C(A,I TROLS AND SAFETY DEVICES WILL BE FACTORY WIRED AND MO UN1ED WITHIN THE UNIT. CONTROLS SHALL INCLUDE FAN RELAY, COMPRESSOR CONTACTOR, 24V TRANSFORMER, REVERSING VALVE COIL, AND LOCKOUT RELAY. F. PIPING SUPPLY, RETURN WATER AND CONDENSATE DRAIN CONNECTION SHALL BE BRASS FEMALE PIPE THREAD FITTINGS AND MOUNTED FLUSH TO CABINET EXTERIOR WITH STAINLESS STEEL, BRAIDED HOSE KIT WITH SWIVEL CONNECTORS. 15. AIR DISTRIBUTION / DUCTWORK & ACCESSORIES NOTES A. REFER TO ARCHITECTURAL PLANS FOR CEILING TYPE AND LAYOUT. B. PROVIDE OFF -WHITE FINISH FOR ALL DIFFUSERS AND GRILLES (VERIFY W/ -TENANT). C. ALL RECTANGULAR DUCTWORK SHALL BE 1" LOW PRESSURE DUCT, SEAL CLASS "C" AND AS FOLLOWS: A. S/A & R/A GALVANIZED SFTEETMEAL, EXTERNALLY INSULATED. B. EXHAUST AIR - GALVANIZED SHEEIMETAL D. ALL DUCTWORK AND DIFFUSERS SHALL BE RATED FOR THE USE, PRESSURE_ AND TEMPERATURE SPECIFIED AND AS REQUIRED BY THE CEILING SYSTEM RATING. E. ALL DUCTWORK SHALL BE FABRICATED AND INSTALLED IN ACCORDANCE WITH "SMACNA" STANDARDS AND LOCAL BUILDING CODES. F. ALL DUCT SIZES ARE CLEAR INSIDE DIMENSIONS. G. SEAL ALL DUCTS, JOINTS AND SEAMS IN AN APPROVED MANNER TO INSURE AGAINST LEAKAGE. H. PROVIDE TURNING VANES IN ALL ELBOWS AND TEES IN ALL CASESND VOLUME CONTROL DAMPERS IN ALL BRANCH DUCTS. 1. ALL ROUND DUCTWORK SHALL BE DOUBLE WALL INSULATED TYPE, CONSTRUCTED OF ROUND SPIRAL LOCKSEAM DUCT WITH GALVANIZED STEEL OUTER, WALL, 1 INCH (25mm) THICK FIBERGLASS INSULATION, GALVANIZED STEEL SOLID INNER WALL: FITTINGS WITH SOLID .INNER WALL. J. ALL RECTANGULAR SUPPLY AND RETURN AIR DUCTWORK, ABOVE SUSPENDED CEILING, SHALL BE EXTERNALLY INSULATED WIIH R -6 FIBERGLASS BATT INSULATION. K. ALL EXPOSED RECTANGULAR SUPPLY AND RETURN AIR DUCTWORK, SHALL BE EXTER- NALLY INSULATE WITH R -6 FIBERGLASS DUCTBOARD, W11H ALUMINUM FOIL JACKET. L. NO INTERNAL INSULATION SHALL BE ALLOWED ON ANY DUCTWORK FOR 1111S PROJECT. 16. COORDINATION NOTES: A. A/C CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING HIS WORK FOR SIZE, LOCATION, CLEARANCE, ACCESS AND ELECTRICAL CHARACIERIS]ICS WITH ALL OTHER TRADES AND TO PROVIDE SHOP DRAWINGS TO ]HE ENGINEER FOR REVIEW BEFORE INSTALLATION OF DUCTWORK OR EQUIPMENT. SHOP DRAWINGS SHALL INCLUDE BEAM OR SIRUCIURE ELEVATION & REQUIRED EQUIPMENT ACCESS AREAS. B. WALL, ROOF, AND CEILING OPENINGS INDICATED ON CONTRACT DRAWINGS ARE NOMINAL DIMENSIONS ONLY AND ALL DUCT,PIPE OR EQUIPMENT PENETRATIONS SHALL BE SLEEVED AND FIRE RATED AS REQUIRED, ADJUST OPENING SIZES AS REQUIRED FOR PROPER INSTALLATION. C. COORDINATE CEILING DIFFUSERS, [REGISTERS IN THE FIELD WITH ELEMENTS. D COORDINATE LOCATION AND OTHERNITRADES SOOTHAT NOAIN D DUCTWORK Will] BUILDING STRUCTURE IERFERENCES OCCUR. E. IN GENERAL, DUCT OFFSETS HAVE NOT BEEN SHOWN. A/C CONTRACTOR SHALL COORDINATE THESE AS REQUIRED. F. MECHANICAL PLANS ARE DIAGRAMMATIC IN NATURE, AND ARE TO BE READ IN CONJUNCTION WITH ARCH. PLUMBING, ELECTRICAL AND STRUCTURAL PLANS AND SHALL BE CONSIDERED AS ONE SET OF DOCUMENTS. DUCT & PIPING OFFSETS, BENDS AND TRANSITIONS REQUIRED TO PROVIDE AND INSTALL A COMPLETE FUNCTIONAL SYSTEM SHALL BE PROVIDED BY THE CONTRACTOR AT NO ADDITIONAL COST TO THE OWNER. 7. THE ORDERING, RFABR CAIIONLOR (INSTALLATION OFNMATERIALS PRIOR OR EQU PIMDEINT., 17. CONTROLS: A TEST AND ADJUST SUPPLY AND RETURN AIR QUANTITIES TO WITHIN 5%' OF DESIGN REQUIREMENTS. B THERMOSTATS FOR ALL NEW AIR CONDITIONING SYSTEMS SHALT_ BE ONE - STAGE COOLING AND HEAIING WITH ON -OFF SWITCH ON SUB -BASE W /LOCKING COVER EQUIV. pRANS HONEYWELL SCHEULE5 OFOfAADUITIONAL RECOMMENDED INFORMATION.UF COORDINATE WITH FLOOR DUCTWORK LEGEND NUTQ ALL SYMBOLS MAY NUT NECESSARILY APPLY TO THESE PLANS 114. AIR CONDITIONING SYSTEMS: A. G_�NER_AL: UNITS SHALL BE A.R.I. STANDARD 320 PERFORMANCE CERTIFIED AND UNDERWRITES LABORATORIES (UL) LISTED. THE UNITS SHALL BE WARRANTED BY THE MANUFACTURER AGAINST DEFECTS IN MATERIALS AND WORKMANSHIP FOR A PERIOD OF ONE YEAR ON ALL PARTS, AND 5 YEARS ON THE COMPRESSOR. B. CASING & CABINE T THE CABINET SHALL BE FABRICATED FROM HEAVY -GUAGE "PAINT -GRIP" GALVANIZED STEEL AND FINISHED WITH IWO COATS OF LACQUER ACRYLIC. THE INTERIOR SHALL BE INSULATED WHH 1/2" IHICK, MULTI- DENSITY, COATED GLASS FIBER. ALL UNITS SHALL ALLOW SUFFICIENT SERVED ACCESS TO REPLACE ]HE COMPRESSOR WITHOUT REMOVAL. A 2" RETURN AIR FILTER RACK /DUCT COLLAR WHICH USES STANDARD SIZE FILTER SHALL BE PROVIDED WITH EACH UNIT. C. REFRIGERANT CIRCUIT ALL UNITS SHALL CONTAIN A SEALED REFRIGERANT CIRCUIT INCLUDING A HERMETIC COMPRESSOR, CAPILLARY TUBE METERING DEVICE, FINNED TUBE AIR -TO- REFRIGERANT HEAT EXCHANGER, REFRIGERANT REVERSING VALVE AND SERVICE PORTS. COMPRESSORS SHALL BE HIGH EFFICIENCY DESIGN FOR HEAT PUMP DUTY AND MOUNTED ON VIBRATION ISOLATORS. COMPRESSOR MOTORS SHALL BE EQUIPPED WITH INTERNAL OVERLOAD PROTECTION. THE FINNED TUBE COIL SHALL BE CONSTRUCIED OF ALUMINUM FINS NOT EXCEEDING FOURTEEN FIN PER INCH BONDED TO COPPER TUBES IN A STAGGERED PATTERN NOT LESS THAN THREE ROWS DEEP. ABBREVIA,riONS ADV FLAT OVAL GALV, METAL DUCTWORK (SEMCO) .AD SUPPLY DUCT UP AFF SUPPLY DUCT DOWN (mil RETURN OR EXHAUST DUCT UP - -'- RETURN OR EXHAUST DUCT DOWN -�-- SLOPING RISE IN DUC TWURK v -� SLOPING DROP IN DUCTWORK (�jAD ACCESS DOOR IN DUCT ieXi2 DUCT SIZE (CLEAR INSIDE DIMENSION) FIRST BTU FIGURE INDICATES PLAN SIZE >e� ROUND DUCT DIAMETER SIZE CD ACOUSTIC LINING IN DUCT (SIZE NOTED CFM INDICATES INSIDE DIMENSIONS) IIIIIIIIIIL- FLEXIBLE CONNECTION -V D� VOLUME DAMPER CHWR AUTOMATIC LOUVER DAMPER -' FUSIBLE LINK FIRE DAMPER W/ ACCESS DOOR CWS ELBOW WITH TURNING VANES -C DUCT SPLIT DB BRANCH TAKEUFF W rIH VOLUME DAMPER DIN RADIUS ELBOW nYrrTrrrrrY rr SLUT DIFFUSER EAT RECTANGULAR DUCT CAPPED & SEALED W/ C VOLUME DAMPER ES NEW DUC TWURK EWT EXISTING DUC TWURK TU REMAIN FC HATCHED AREA NOT IN CONTRACT FD SOUND ATTENUATUR (SA) FL CEILING DIFFUSER (4 -WAY) )l FULL LOAD AMPS GPM CEILING DIFFUSER (3 -WAY) FIP HORSE POWER �j CEILING DIFFUSER (2 -WAY) LAT CEILING DIFFUSER (I -WAY) LD CEILING ALCAN DIFFUSER LRA RETURN REGEISTER OR GRILLE I T.G. � .. TRANSFER GRILLE ON BOTH SIDES OF WALL MAT FLEXIBLE DUCT =�rrU OPENING IN WALL ABOVE CEILING (SIZE) -< SUPPLY REGISTER U. RETURN REGISTER OR GRILLE _ LOUVER DOUR (SQUARE FEET) U UNDERCUT DOUR C NET FREE AREA I SQUARE FEET A FIRE DAMPER NUTQ ALL SYMBOLS MAY NUT NECESSARILY APPLY TO THESE PLANS 114. AIR CONDITIONING SYSTEMS: A. G_�NER_AL: UNITS SHALL BE A.R.I. STANDARD 320 PERFORMANCE CERTIFIED AND UNDERWRITES LABORATORIES (UL) LISTED. THE UNITS SHALL BE WARRANTED BY THE MANUFACTURER AGAINST DEFECTS IN MATERIALS AND WORKMANSHIP FOR A PERIOD OF ONE YEAR ON ALL PARTS, AND 5 YEARS ON THE COMPRESSOR. B. CASING & CABINE T THE CABINET SHALL BE FABRICATED FROM HEAVY -GUAGE "PAINT -GRIP" GALVANIZED STEEL AND FINISHED WITH IWO COATS OF LACQUER ACRYLIC. THE INTERIOR SHALL BE INSULATED WHH 1/2" IHICK, MULTI- DENSITY, COATED GLASS FIBER. ALL UNITS SHALL ALLOW SUFFICIENT SERVED ACCESS TO REPLACE ]HE COMPRESSOR WITHOUT REMOVAL. A 2" RETURN AIR FILTER RACK /DUCT COLLAR WHICH USES STANDARD SIZE FILTER SHALL BE PROVIDED WITH EACH UNIT. C. REFRIGERANT CIRCUIT ALL UNITS SHALL CONTAIN A SEALED REFRIGERANT CIRCUIT INCLUDING A HERMETIC COMPRESSOR, CAPILLARY TUBE METERING DEVICE, FINNED TUBE AIR -TO- REFRIGERANT HEAT EXCHANGER, REFRIGERANT REVERSING VALVE AND SERVICE PORTS. COMPRESSORS SHALL BE HIGH EFFICIENCY DESIGN FOR HEAT PUMP DUTY AND MOUNTED ON VIBRATION ISOLATORS. COMPRESSOR MOTORS SHALL BE EQUIPPED WITH INTERNAL OVERLOAD PROTECTION. THE FINNED TUBE COIL SHALL BE CONSTRUCIED OF ALUMINUM FINS NOT EXCEEDING FOURTEEN FIN PER INCH BONDED TO COPPER TUBES IN A STAGGERED PATTERN NOT LESS THAN THREE ROWS DEEP. ABBREVIA,riONS ADV ABOVE .AD ACCESS DOOR AFF ABOVE FINISHED. FLOOR AL ACOUSTICAL LINING ALD AUTOMATIC LOUVERED DAMPER ATC AUTOMATIC TEMPERATURE CONTROL DDD BACK DRAFT DAMPER BG BOT-FUM GRILLE DR BOTTOM REGISTER BTU BRITISH THERMAL Ui I.' CC COOLING COIL CD CEILING DIFFUSER CFM CUBIC FEET PER MIN'LICE CG CEILING GRILLE CHWS CHILLED WATER SUP'_ ' CHWR CHILLED WATER RET1J:- I CR CEILING REGISTER CWS CONDENSER WATER S _ -,D LY CWR CONDENSER WATER F': JRN DB DRY BULB DIN DOWN DR DROP EAT ENTERING AIR TEMPE,�: -. TURE EF EXHAUST FAN ES EQUAL SPLIT EWT ENTERING WATER TE' 11 '.RATURE FC FLEXIBLE CONNECTI( q FD FUSIBLE LINK FIRE J WEIR W/ DUCT ACCESS DOOR FL FLOOR FLA FULL LOAD AMPS GPM GALLONS PER MINU Tt- FIP HORSE POWER KW KILOWATT LAT LEAVING AIR TEMPE A -URE LD LINEAR DIFFUSER (C`:; _ING, WALL, SILL, OR FLOOR) LRA LOCK ROTOR AMPS LWT , LEAVING WATER TEP ':'2ATURE MAT MIXED AIR TEMPERAT J MBH THOUSAND BTU PER . iU JR MIN MINIMUM MLO MANUAL LOUVER DAN?t 2 MO (WO) MASONRY OPENING 6 FI .L OPENING) NC NORMALLY CLOSED NFA NET FREE AREA NIC NOT IN THIS CONTRACT_ NK NECK NO NORMALLY OPEN ANTS NOT TO SCALE UAI OUTSIDE AIR INTAKE OBD OPPOSED BLADE DAMPL % PSI (G) POUNDS PER SQUARE 1, CH <GAUGE) RA RETURN AIR RPM REVOLUTIONS PER MIN JTE SA SOUND ATTENUATOR SMK SMOKE EXHAUST TG TOP GRILLE TR TOP REGISTER TRG TRANSFER GRILLE UON UNLESS OTHERWISE f F- TED VD VOLUME DAMPER WB WET BULB WMS WIRE MESH SCREEN NOTE= ALL SYMBOLS MAY NOT NEC'__'�SARILY APPLY TO THESE PLANS I_., - k HVAC DESIGN REQUIRES: YES NO DUCT SMOKE DETECTOR FIRE DAMPERS SMOKE DAMPERS FIRE RATED ENCLOSURES FIRE RATED ROOF /FLOOR CEILING ASSEN 3LY FIRE STOPPING SMOKE CONTROL a. ARCH.LICENSE AR 07671 U 11 W U_ LL. U °� W 0 =N� �((�n� Q LzJ _ o 0 Q� (n o C d- z IL LTJ W cD z o cfl U °0 (0 o�r� 0 U cl. c_ d• c a� c, U �� 0 ARCH. LICENSE AR 0767) job n.� 9903 date. 01-28-071 scale. As Shown drawn by A G. reviewed by. Lis M ed. 1-28-07 mclof sheet no. M E�