07-780-021LENOTH AS REWIRED CONDEnSIN0 NIT U
- -IIB�_ (TYPICAL)
,,,$$$ AVCIIOR CONVENSINO UNIT
SEE PLANS FOR QUANTITY 1.] 12 SINO MIN. f- WOE. REAOED
ST
_ Or STRAP 10
YS
J' HIGH X 2 1/1• WIDE ALUM04II4 RAIL ---- ���333 TTII — J. (KCAL EACH CORNER)
1 1/2 XI 1/2• AIUUINVN SW AR!
2'Q 'x1/ T1iICK tSOMODE
NEOPRENE PAD (TYPICAL EACH
34' OORNER)
P1101 FV41 MAKE 4'M'x1 /4'AUXINL BASE
LEN D4 AND M1DTH OF .�'EE DETAIL BELOM'.
AVE DEFINED BY BASE (I31I L AT EACH VERTICAL
ALL IAROUT S 2 ANOIL)
ir4JI:
DETAIL W COMPLIANCE WITH FLORIOA BVRDING CODE
AND BAlf p ON REFARBICATFD AW411 UITM STAND
(A(S NANU ACrURED BY A/0 )RA J�91FjA3
1 1/)'X1 1/1' A1.LMINVM SQUARE fL. 33411 t1� PARKWAY. ROYAL PALM BEACH,
BASE PI..1E4. — 4• 7/16' HOLE FOR ] /B'" ) 4• `
� -1— GALVAIBiED STEFl llllll• ( 1
xWIK BOLT 4TH 4• MINIMUM
EMBEDMENT INTO CONCRErE
1'
1 1/2-X1 1/2' ALUMINUM
SQUARE TUBING
ROOF JOIST 4•x4'xt/4• ALUMINUM BASE
2- 3/8* icmc•
BOLTS E I ..•
(T) t/2' ACII BA NLATE) T
(1t2 1/2 FMH BASE PLATE) NUT A E
2 -3ib' TI IRWGH ecIL1J VETAL PLATE/WA91ER
re OT NUTS WIIERE LEOJ NOT BOLTS T11RU CURB. ROOF DECK
LOCATED ABOVE JOIST AND JOIST OR WEZD CURB TO
ROOF DECK. USE CONCRETE
ANCHORS W POURED DECKS.
CONDENSING UNIT PREFABRICATED
SUPPORT DETAIL
PATE STAINLESS ADJUSTABLE
CLAMP,
PATE STEPPED PVC
BOUT
STRIPING
MASTIC
MEMBRANE
N.T.S.
PATE SPUN ALUMINUM
BASE,
ROOF PIPE SEAL
N.T.S.
SPRING & NEOPRENE
TYPE VIBRATION
ISOLATORS
TYP. 3/8" HANGING RODS
(THREADED) COORDINATE W/
STRUCTURAL ENGINEER AND /OR
ARCH. ON HOW TO FASTEN TO
STRUCTURE - --
MOUNTING CLIPS OR I
UNITS CONNECTION TO
SUPPORT RODS AS
RECOMMENDED BY MFG.
ELECTRIC HEAT
ASSEMBLY -�
FLEXIBLE DUCT
CONNECTOR
BUILT UP ROOF
TRANSITION AS REQ`D.
RETURN AIR DUCTWORK
OUTSIDE AIR DUCT W/
OPPOSED BLADE DAMPER
(TYPICAL) T
FILTER & RACK ASSEMBLY
1" GALV. DRAIN PAN
STRAPPED TO A.H.U.
�� INSULATED CONDENSATE
DRAIN AND TRAP (SEE
a PLUMB. FOR CONTINUATION)
��— - REFRIGERAIJT LIIJES TO
SUPPLY CONDENSING UNITS
41R DUCT INSULATE SUCTION LINE)
Aga
SMOKE DETECTOR IN SUPPLY AUX. DRAIN (SEE PLUMB.
AIR DUCT AS REQUIRED FON CONTINUATION)
TRANSITION AS REQUIRED AIR DANDLING UNIT
PROVIDE 24" SERVICE CLEARANCE
FOR ALL ACCESS PANELS
A.H.U. HANGING DETAIL
N.T.S.
CONC.
SLAB
LIQUID
ONE PIECE HINGED
STEEL SHELL
20 GAUGE
SHEET-METAL
(SIZE AS REQ'D) --
FLASHING AS RECOM.
BY HANUF. —
SLEEVE
ILL SLEEVE VITH FIRE-PROOF/
IRE RESISTANT
D_ICON SEALANT FOAM
IC PR -855
29/50 RATED INSUJLATION
SUCTION LINE
REFRIGERANT LINES
FROM ACCU'S
w'
I�• �� f I ROOF SLAB
II II I III II II \— 1 DETAIL. THIS DVG.
REFRIGERANT PIPE
RAINCOVEIS DETAIL
N.T.S.
FLASHING AS RECOMMENDED
BY MANUFACTURER
PITCH PAN TYPE
SUPPORT CURB —� I
ISUI_IATING PAD FOR NUN
INSULATED LINES & ARMAFLEX
(25/:50 RATED) FOR INSULATED LINES
�---- ALUMINUM STRUTS 1 -5/8' X
1 -5 /8' X .105' THICK (2,6MM) BY
B-LINE OR APPROVED EQUAL
COPPER LINE
PAINT ALL EXTERIOR REFRIGERANT
INSIJI_ATIONF WITH 2 CEIATS OF
WHITE ARMA -FLEX PROJECTIVE
PAINT.
TYPICAL REFRIGERANT
LINES CLAMPED TO CURB
INSULATE ALL REFRIGERANT
SUCTION LINES WITH 3/4'
THICK ARMAFLEX INSULATION OR
APPROVED EQUAL
TYP. RU OF STRUCTURE
REFRIGERANT LINE
SUPPORT DETAIL
° RETAINING �- HANGER
° CLIP ROD
FLAT BAR ROD C- C.IAMf! TU STRUCTURAL FLANGE
W/ RETAINING CLIP OR LOCK NUT
CONCRETE INSERTS
L ERA &I ED CONCRETE
F4 A "�S1RAP EIHANGEL HANGER
WASHER : STRAP j— ROD
NUT PpWFR A- Q Ilk AD STUDS J N10
FUR DUCTS UP TO 10' FUR DUCTS UP TO 36' 51EEL—U RU-QME OR DECK)
MAXIMUM DIMENSION MAXIMUM DIMENSION
DRIVE PIN 11HREADED STUD
PUIJDER ACTUATED FASTENERS ` —,
DUCT SUPPORT SYSTEM FOR x HANGER HANGER
ALL EXPOSED DUCT STRA ROD
•'' r ' ... �LP�I1 S_LUP_�ILTIII_ NUT t;
4r STEEL. (STRUCTURE OR DECK) BOLT
HANGER
- STRAP
FOR DUCTS Ur� FRICTION CLAMPS
10 18' MAX. STRAP
DIMENSION
L \- WASHER
EXPANSION SHIELDS EXPANSION NAIL WASHER NUT
CONCRETE ANCHORS
NOTE1
CUNSIRUC;TION AND INSTALLATION SHALL DE
AS PER SiMACNA STANDARD FOR TYPE'
OF DUCIVORK INSTALLED IN FACILITY,
UPPED ATTACHMENT METHODS
OF HANGING DUCTS AI41) EQUIPMENT DETAIL
N.T.S.
LOW VELOCITY SUPPLY
OR RETURN AIR DUCT
" SPIN -IN COLLAR WITH VOLUME D „MFER
OPERATOR TO BE OUTSIDE THE INSULATION.
PROVIDE INSULATION GUARD WHERE
NECESSARY (DAMPER WHERE NOTED),
(PROVIDE DUCT DAMPERS WHERE ACCESSIBLE)
INSULATED FLEX DUCT
—SEAL JOINT WITH DUCT SEALER
INSULATE OR LINE SURFACES
TO PREVENT CONDENSATION.
CEILING DIFFUSER OR RETURN REGISTER.
(FLEXIBLE DUCT CONNECTION DETAIL
N.T.S.
1/2" HANGER ROD
(4 REQ'D.) FASTENED
TO CONCRETE STRUCTURE
ABOVE WITH EXPANSION /' HANGEk 'i00
BOBS. HILTI ANC /
BOLT ICEXP. ANCHOR.
ROD COUPLING TYPE
2 1/4" EMBEDMENT.
PORT CROSS
1 (IF REQUIRED)
HANGER ROD A.H -U. OR INLINE FAN
SPRING �%BEYONG
,_------ISOLATOR
BOTTOM HUNG
INLINE FAN OR A/C UNIT MOUNTING' DETAIL
N.T.S.
ALL DAMPERS SHALL COMPLY WITH NFPA 90A UL 555
IU DUCT
ACCESS DOOR
2
O3 INSULATION WHERE DUCTS
ARE SO SPECIFIED
OEQUIPMENT ROOM) i IN
O NOT USED,
2
6
6
O6 1/8” CLEARANCE PER 12" of
DUCT ON ALL FOUR SIDES
O COLLAR (SEE NOTES)
10
9
O8 I" TYP. ALL FOUR SIDES
0 1- 1/2 "X1 -I/2 "x10 GA. OR
HORIZONTAL MOUNTING DETAIL
HEAVIER ANGLES SNUG TO
FLOOR & COLLAR ALL
AROUND
6
CLOSER
t0 "S" SLIP
11 8
ANGLE
AS REQ'D
I1 WALL
7
BY LOCAL
BLDG.
12 FLOOR SLAB
DEPT.
NOTES:
1. COLLAR GAUGES;
1
2
A. FOR COLLARS NOT
( 33
EXCEEDING 36'W OR
24 "11 - 16 GAUGE
B. FOR COLLARS
EXCEEDING 36 "W OR
24 "14 - 14 GAUGE
1. ATTACH ANGLES 10 COLLARS OR (/ 10
]EC SCREWS) WITH 1/4" 20 BOLTS &
9
10
NUTS 12" C -C MAX. MITI. 2 BOLTS
IN EACH SIDE TOP & BOTTOM
3. INSTALLATION SHALL CONFORM
VERTICAL MOUNTING DETAIL
TO NIPA -90A
4. PROVIDE ACCESS DOORS TO
SERVICE FUSIBLE LINKS
AS REQUIRED
NOTE: TYPE "B' IS DETAILED FOR ALL SUPPLY AIR DUCTS
TYPE "A" MAY BE USED FOR ALL RETURN ARE DUCTS AS REQUIRED.
ALL MOTORIZED FIRE SMOKE DAMPERS SHALL BE FSD -60 TYPE.
TYPICAL S 1+ Y L E "B ••
FIRE DAMPER DETAIL 1
X11 ST
u 1
4 ry
•^Lr s
'i
t9T
V `
•
ARCH,LICENSE
AR 076T1
, 1U V,
C\
O �
ALL- 1
,! p
U UCH
— -
-T
OC UV)
c
Q) — o
U: L°
c)
-
0 C)
Qc
Q�
ai
E
U
C
U
•2,
O
t-
0-
\ / (D
O
CO
0)
U)
00
(D
o U (t7
t�
U
<� w
U
O
0
0
0
'q-
TV
—r -� M
U� U �—
O �u -
o
v
U
O
� C)
-' O
U
U
ARCH. LICENSE
AR 07671
job no
9903
date.
01-28-07
SCOIe.
As Shown
drown by
A G.
reviewed by.
C.M
issued.
01— 28— 07
Al A
I :I
I