07-780-019TYPICAL TURNIN( ON ALL ELBOWS (DOUBLE WALL) CORNER ANGLE TYPICAL DUC Lialf1 FOR WRING OF AUXILIARY DEVICES REFER TO MANUFACTURERS INSTALLATION INSRTVCRONS OR CONTACT MANUFACTURER , SYSTEM "VAC CONTROL FAN POWER OR CONTROL FAN TTIERMOSTAT 15 18 17 15 19 20 NO 0 NO NO 0 NO AUXILIARY ALARM CONTROL CONTACTS SHOWN IN 51ANOBY CONTACTS TRANSFER DURINO ALARM AS INDICATED BY THE ARROWS A/C DUCT 0MOKE DETECTOR-WIRING DETAIL PIVAC FAN CONTROL WIRING IW1TI-I0U`T FIRE ALARM CONTROL PANEL], FOR SYSTEM SHUT -DOWN N.T.5. N.T.S. ELBOW TURNING VANE DETAIL N.T.5. ;TS ACCORDING 1A STANDARDS TYPICAL HANGING STRAP AND SADDLE HANGING DETAIL TYPICAL Z BAR AND WIRE DUCT HANGING DETAIL DUCTS DETAIL N.T.S. TYPICAL CHANNEL AND STRAP DUCT HANGING DETAIL J__ TYPICAL ROOF CAP 3/8' THREADED RODS SHEETMETAI_ DUCTWORK TYPICAL ROOF CAP 0 O WHITE CEILING GRILLE TYPICAL WALL CAP SPEED CONT O (SOLID STATE) NOTES, I.- PROVIDE BACKDRAFT DAMPER W/ BIRDSCREEN 2.- FLAS14 & SEAL WALL AND ROOF CAP 3.- PROVIDE INTERNAL ISOLATION AND SOUND INSULATION 4.- SUPPORT FAN FROM STRUCTURE CABINET CEILING FAN DETAIL N.T.S. INSULATED SHEET METAL PLENUM BOX ALTERNATE FOR LOW_ CLEARANCE N.T.S. INSULATED ROUND METAL DUCT FLEXIBLE IF ALLOWED BY CEILING RATING ( SHEETMETAL IF NOT ALLOWED) 6' SHEETMETAL EXTENSION COLLAR (INSULATED) SUSPENDED T -BAR OPPOSED BLADE DAMPER CEILING GRID 26 GAUGE COLLAR LAY -IN ACOUSTICAL — I INSULATION BLANKET CEILING TILE LE__ SUPPLY AIR DIFFUSER SUPPLY AIR DIFFUSER N.T.S. Q WING NOT ZT cG� BEARING OPTION ARM ROD CONTINUOUS ON 2' W.G. CLASS DUCT A140 ON ALL DAMPERS OVER 12' DIA. DUCT ROUIJD DAI1PER ELEVATION FIG. C •a TWO BLADE ARRANGEMENT FIG. 3/8' QUADRANT DUCT 1/2' QUADRANT DUCT 3/8' PIN PIN' ROD - �� 12' MAX. U� CLEARANCE CLEARANCE ALL UP TO 18' ALL ARUUI4D AROUND 19' TO 48'-- 1715, A NOTE, OVER 12' HIGH USE MULTIPLE BLADES. STIFFEN AS REQ'D P P D / OUTSDE I CT EP�II2 � END BEARING INSIDE SIDE END BEARING ELEVATION REQUIRED ON 3' W.G. FIG. A or B CLASS DUCT AND OVER. DPTIU14AL FOR OTHERS. VOLUME DAMPEN DETAIL N.T.6. BRANCH CONNECTION DETAIL NT5 JOIN FLEXIBLE DUCT TO FITTING IN ACCORDANCE W/ MANUFACTURER'S INSTALLATION INSTRUCTION. USE DUCT SEALER & BANDING DEVICE — CLEVAFLEX SPIN -IN DAMPER/ EXTRACTOR MODEL 0 FDESC (INSULATED) DUCT V_1� AIR FLOW FLEXIBLE DUCT TAKEOFF DETAIL N.T.S. )LADE ITHIN 2 ANCH _OFF STANDARD DUCT MADE WATER TIGHT STIFFENERS MAY BE GOOSENECK DETAIL N.T.S. TURNING �,.,,� CORN[ CHA SPLI rnNTPnI 25f' %IN 10' -0' MIN. JCE FROM FRESH TAKE DUCTS, SPLITTER DAMPER DETAIL NT-5 TYPICAL DUCT DAMPER BLADE FI'JERGLASS OR STEEL SUPPLY DUCT CONTROL DAMPER APPLY DUCT SEALER ALL AROUND APPLY SPIN -IN FITTING W/ VOLUME �— CONTROL DAMP::R (INSULATE) AIRFLOW —, 45' SHOETAP W/ TRANSITION TO ROUND. INSULATE -INSULATED FLEXIBLE DUCT RUN (TYP.) STAINL =!S STEEL DRAW BAND Z�OTES� CONICAL BE"LLMOUTH FITTING FLEX. MASTER SERIES 4000 MODEL DC -D 1. PREFERRED FITTING WHERE ALLOWED BY SPACE IS THE BELLMOUTH FITTING WHICH REQUIRES A HINIMUI4 OF 2' ADDITIONAL DUCT CLEARANCE (NOTEI V OF FLANGE MAY BE BENT OVER. FOR INSTALLATION SEE MANUFACTURER'S RECOMMENDATION. 2, SHOE TAP SHOULD BE SIZED TO PROVIDE A MINIMUM OF 140/ LARGER OPENING THAN ROUND DUCT SIZE. 01)1 . ITJI TYPICAL FLEX. DUC, CONNECTION DETAIL N.T.S. V "r ­) 11�lj -,;_I rl USE ONE OF AVALABLE POWER INPUTS k _ 1 2 10 12 14 l� 120 24V vxc 2z -o 40 L[_ C\ VAC AUXILIARY ALARM CONTROL CONTACTS 0 a; ' 13 18 17 18 19 20 . a C) n N`Y7NO 0 NT NO (01 C AUXILIARY ALARM CONTROL CONTACTS O L1— SflCWN IN STANOBY CONTAG13 TRANSFER VOIDLE/VI SIBLE ALARM IB L.AR DURING ALARM AS INDICATED BY TI-IC ARROWS `OUIVILEN7 SIMPLEX (C Q� I.00EL J4093 AT 120 VAC FIRE ALARM PANEL INTERFACE CONTACTS L FOR STAND ALONE APPLICATIONS OR COI* IPUANCE TO NFPA 90A. 8 )— 9 ai E ' KATE IN NORMALLY OCCUPIED N0� 2EA OF PREMISES LOW VOLTAGE ALARM INITIATION CONTACTS .0 SHOWN IN STANDBY CONTACTS TRANSFER Q_ DUMNO ALARM AS INDICATED BY THE ARROWS TROUBLE CONTACTS ® ( +) ALARM SIGNAL CLOSED IN STAND BY AND ALARM T N BY s E AUXILIARY POWER OPEN YAIILE DETECTOR HEAD OR POWER IS 7 REMO AND DURING 7 ( +) AUXILIARY POWER RESETTD 10� TROUBLE POWER 15 CONTACTS e DUCT DETECTOR EOUIVALENT TO SIMPLEX 12098 AT 120 VAC Lialf1 FOR WRING OF AUXILIARY DEVICES REFER TO MANUFACTURERS INSTALLATION INSRTVCRONS OR CONTACT MANUFACTURER , SYSTEM "VAC CONTROL FAN POWER OR CONTROL FAN TTIERMOSTAT 15 18 17 15 19 20 NO 0 NO NO 0 NO AUXILIARY ALARM CONTROL CONTACTS SHOWN IN 51ANOBY CONTACTS TRANSFER DURINO ALARM AS INDICATED BY THE ARROWS A/C DUCT 0MOKE DETECTOR-WIRING DETAIL PIVAC FAN CONTROL WIRING IW1TI-I0U`T FIRE ALARM CONTROL PANEL], FOR SYSTEM SHUT -DOWN N.T.5. N.T.S. ELBOW TURNING VANE DETAIL N.T.5. ;TS ACCORDING 1A STANDARDS TYPICAL HANGING STRAP AND SADDLE HANGING DETAIL TYPICAL Z BAR AND WIRE DUCT HANGING DETAIL DUCTS DETAIL N.T.S. TYPICAL CHANNEL AND STRAP DUCT HANGING DETAIL J__ TYPICAL ROOF CAP 3/8' THREADED RODS SHEETMETAI_ DUCTWORK TYPICAL ROOF CAP 0 O WHITE CEILING GRILLE TYPICAL WALL CAP SPEED CONT O (SOLID STATE) NOTES, I.- PROVIDE BACKDRAFT DAMPER W/ BIRDSCREEN 2.- FLAS14 & SEAL WALL AND ROOF CAP 3.- PROVIDE INTERNAL ISOLATION AND SOUND INSULATION 4.- SUPPORT FAN FROM STRUCTURE CABINET CEILING FAN DETAIL N.T.S. INSULATED SHEET METAL PLENUM BOX ALTERNATE FOR LOW_ CLEARANCE N.T.S. INSULATED ROUND METAL DUCT FLEXIBLE IF ALLOWED BY CEILING RATING ( SHEETMETAL IF NOT ALLOWED) 6' SHEETMETAL EXTENSION COLLAR (INSULATED) SUSPENDED T -BAR OPPOSED BLADE DAMPER CEILING GRID 26 GAUGE COLLAR LAY -IN ACOUSTICAL — I INSULATION BLANKET CEILING TILE LE__ SUPPLY AIR DIFFUSER SUPPLY AIR DIFFUSER N.T.S. Q WING NOT ZT cG� BEARING OPTION ARM ROD CONTINUOUS ON 2' W.G. CLASS DUCT A140 ON ALL DAMPERS OVER 12' DIA. DUCT ROUIJD DAI1PER ELEVATION FIG. C •a TWO BLADE ARRANGEMENT FIG. 3/8' QUADRANT DUCT 1/2' QUADRANT DUCT 3/8' PIN PIN' ROD - �� 12' MAX. U� CLEARANCE CLEARANCE ALL UP TO 18' ALL ARUUI4D AROUND 19' TO 48'-- 1715, A NOTE, OVER 12' HIGH USE MULTIPLE BLADES. STIFFEN AS REQ'D P P D / OUTSDE I CT EP�II2 � END BEARING INSIDE SIDE END BEARING ELEVATION REQUIRED ON 3' W.G. FIG. A or B CLASS DUCT AND OVER. DPTIU14AL FOR OTHERS. VOLUME DAMPEN DETAIL N.T.6. BRANCH CONNECTION DETAIL NT5 JOIN FLEXIBLE DUCT TO FITTING IN ACCORDANCE W/ MANUFACTURER'S INSTALLATION INSTRUCTION. USE DUCT SEALER & BANDING DEVICE — CLEVAFLEX SPIN -IN DAMPER/ EXTRACTOR MODEL 0 FDESC (INSULATED) DUCT V_1� AIR FLOW FLEXIBLE DUCT TAKEOFF DETAIL N.T.S. )LADE ITHIN 2 ANCH _OFF STANDARD DUCT MADE WATER TIGHT STIFFENERS MAY BE GOOSENECK DETAIL N.T.S. TURNING �,.,,� CORN[ CHA SPLI rnNTPnI 25f' %IN 10' -0' MIN. JCE FROM FRESH TAKE DUCTS, SPLITTER DAMPER DETAIL NT-5 TYPICAL DUCT DAMPER BLADE FI'JERGLASS OR STEEL SUPPLY DUCT CONTROL DAMPER APPLY DUCT SEALER ALL AROUND APPLY SPIN -IN FITTING W/ VOLUME �— CONTROL DAMP::R (INSULATE) AIRFLOW —, 45' SHOETAP W/ TRANSITION TO ROUND. INSULATE -INSULATED FLEXIBLE DUCT RUN (TYP.) STAINL =!S STEEL DRAW BAND Z�OTES� CONICAL BE"LLMOUTH FITTING FLEX. MASTER SERIES 4000 MODEL DC -D 1. PREFERRED FITTING WHERE ALLOWED BY SPACE IS THE BELLMOUTH FITTING WHICH REQUIRES A HINIMUI4 OF 2' ADDITIONAL DUCT CLEARANCE (NOTEI V OF FLANGE MAY BE BENT OVER. FOR INSTALLATION SEE MANUFACTURER'S RECOMMENDATION. 2, SHOE TAP SHOULD BE SIZED TO PROVIDE A MINIMUM OF 140/ LARGER OPENING THAN ROUND DUCT SIZE. 01)1 . ITJI TYPICAL FLEX. DUC, CONNECTION DETAIL N.T.S. V "r ­) 11�lj -,;_I rl V 1 k _ ♦ �r ,� 7 ?' T • a1: 4�PAI��E .'j l� L[_ C\ O 0 a; ' F . a C) n ARCH.LICENSE 0 AR 076-/1 V 1 _ U U: l� L[_ C\ O 0 a; ' > E . VL C) n 0 0 V) 0 (01 C O L1— LL_ 4� (C Q� 4—1 L ai E c 41 U .0 O Q_ �C cD X� JT O C (D Co O) cD (o O �1/ � t� M W (D L U Q C O �I- 1 U �-- - U. _ 1✓ 0 0 z U__ M 0 U U I ARCH. LICENSE AR 0767( 9m job no. 9903 date. 01-28-07 scale. As Shorn drawn by A G. reviewed by. C.M issued. 0-11-28-07 11mogs== r v r F i sheet no. M L1-