Loading...
03-1559-109PLUMBING GENERAL NOTES: 1. ALL WORK TO BE DONE IN ACCORDANCE WITH THE LOCAL PLUMBING AND BUILDING CODES. 2. BUILDING DRAINAGE SYSTEM DESIGN BASED ON 1 /8"/FT MINIMUM FALL, ANY DEVIATIONS SHALL BE APPROVED BY ARCHITECT & ENGINEER. 3. CONTRACTOR TO PROVIDE 1" (MIN.) WATER PIPE; CAPPED AT EVERY ELECTRICAL'SWITCHGEAR ROOM OR METER ROOM TO BE USED AS GROUND. 4. ALL VALVES UNDERGROUND TO BE INSTALLED IN PRECAST CONCRETE BOXES, BROOKS OR EQUAL 5. PLUMBING CONTRACTOR TO FURNISH ALL REQUIRED FLASHINGS FOR PIPES TO ROOFING CONTRACTOR.. 5. MATERIALS SHALL BE ALL NEW AND AS FOLLOWS: A) DRAINAGE PIPING - NO HUB CAST IRON STD. 301 OR PVC SCH. 40 B) WATER PIPING - SCH. 40 GALVANIZED STEEL (UNDERGROUND), COPPER TUBE TYPE L (INTERIOR) C) A/C CONDENSATE DRAIN - SCH. 40 PVC OR COPPER TYPE V IN CEILING PLENUM. D) FLOOR AND ROOF DRAINS IF USED, JOSAM OR EQUAL E) VALVES - 125 PSI NIBCO SCOTT OR EQUAL. F) HOSE BIBBS CHICAGO 952, OR EQUAL. G) A/C CONDENSATE DRAIN INSULATION - 1/2" ARMAFLEX. ( *) NO PVC PIPE IN CEILING SPACE R/A PLENUM: 7. PROVIDE ALL EXCAVATION BACKFILL AND COMPACTION REQUIRED BY All PLUMBING WORK. B. PERFORM THE FOLLOWING TESTS; A) WATER PIPING SHALL BE SUBJECTED TO HYDROSTATIC PRESSURE TEST OF 100 PSIG FOR A PERIOD OF TIME SUFFICIENT TO EXAMINE ENTIRE SYSTEM BUT NOT LESS THAN ONE HOUR. B) ' DRAINAGE PIPING - BEFORE INSTALLATION OF ANY DRAINS, THE ENDS OF THE SYSTEM SHALL BE CAPPED AND ALL LINES FILLED WITH WATER TO HIGHEST POINT AND ALLOWED TO STAND UNTIL INSPECTION IS MADE AND WATER LEVEL REMAINS CONSTANT. C) CORRECT ALL DEFECTS DISCLOSED BY ABOVE 'TESTS; 9. STERILIZE ALL WATER LINES WITH MIXTURE OF (2) TWO POUNDS OF CHLORINATED LIME TO EACH 1000 GALLONS OF WATER (50 RPM OF AVAILABLE CHLORINE). RETAIN MIXTURE IN PIPES 24 HOURS AND FLUSH THOROUGHLY WITH POTABLE WATER BEFORE PLACING IN SERVICE. 10. COMPLETE SYSTEM FIXTURES AND EQUIPMENT SHALL BE GIVEN AN IN- SERVICE TEST AFTER COMPLETION OF THE INSTALLATION. 11. PLUMBING CONTRACTOR SHALL FURNISH A WRITTEN GUARANTEE THAT ALL PLUMBING WORK SHALL BE FREE` FROM DEFECTS OF MATERIALS AND WORKMANSHIP FOR A PERIOD OF ONE YEAR FROM DATE OF FINAL ACCEPTANCE, AND THAT HE WILL, AT HIS EXPENSE REPAIR AND REPLACE ALL WORT( WHICH BECOMES DEFECTIVE DURING GUARANTEE PERIOD. ri - m H11 !1 ®I PLUMBING LEGEND SH SHOWER (SAN) SANITARY CM COFFEE MAKER ------- - - - - -- (V) VENT REF REFRIGERATOR ---- - - - - -- (CW) COLD WATER IWH INSTA WATER HEATER - - (HW) HOT WATER CO WALL (LEAN OUT KS KITCHEN SINK LAV LAVATORY WC WATER CLOSET (N) NEW (E) EXISTING ri - m H11 !1 ®I