Loading...
03-1559-057VERTICAL. PROVIDE 2 #6 VERT. ON EACH SIDE OF ALL OPENINGS BETWEEN 3'--0" AND 8' -0" REINFORCE WALLS W/ #9 GAGE LADDER TYPE HORIZONTAL JOINT REINFORCEMENT ® 16" O.C. ALL WALLS MUST BE GROUTED SOLID UP TO 2' -0" ABOVE SLAB. 2.— SEE M.E.P DRAWINGS FOR EXACT LOCATIONS OF ALL FLOOR OPENINGS. 3.— CONTRACTOR TO COORDINATE LOCATION OF PRECAST JOISTS WITH ALL OTHER TRADES. SPACING SHOWN FOR PC JOISTS TO BE MAXIMUM. 4.— SEE ARCHITECTURAL DRAWINGS FOR ADDITIONAL DIMENSIONS & INFORMATION. 5.— REFER TO ARCHITECTURAL DRAWINGS FOR INTERIOR NONBEARING WALLS, OPENINGS SIZES AND LAYOUT, BALANCE OF DIMENSIONS, AND ADDITIONAL INFORMATION. 6.— TIE BEAM (TB) TO BE 8%12" W/2 #5 T&B AND #3012" STIRRUPS. 7.— REFER TO ARCHITECTURAL DRAWINGS FOR ADDITIONAL DIMENSIONS, INFORMATION INTERIOR WA -L LAYOUT, MECHANICAL OPENINGS, SLAB DEPRESSIONS, OPENING SIZES AND OTHER INFORMATION. 8.— S -1 INDICATES 6" CONC. SLAB W/ #5012" 0/C EA WAY BOT. 9.— PROVIDE CORNERS BARS ON ALL TIE BEAM TO MATCH LONGITUDINAL REINFORCEMENT WITH A SPLICE EQUAL TO 48 DIA. 10.— ALL COLUMNS SHALL TERMINATE WITH A STANDARD HOOK INTO TIE BEAM,2" FROM TOP OF BEAM. 11.— SPLICE ON TIE BEAM REINFORCEMENT TO BE 32" MINIMUM. PARTIAL 3RD FLOOR FRAMING PLAN- NORTH SCALE: 1/8" = 1' -0" EXTENT OF 6" CONC. SLAB w ! • • i • • • • • Y Y R • Y • Y • • • • 10K 5.8 Y • • • • r•7 . GuVRR w ••• • •Rr• • i II II II I! II 11 N 11 II � II II fl II II II II II II I ll II II II II II II II I II II c7 II Il C7 II Il II fl r II II II II II II III II I I I I 3SB- REVISION BY 1 1/29/04 PERI"1IT REVISION 2 4/19104 OWNER REVISION 3 618104 REVIEW 4 S/14/04 OWNER REVISION 5 11/5 /04 GENERAL REv1Sl0 6 2/11 /05 GENERAL REVISIChN 8 8/17/05 GENERAL REVISION t t q I�t ti 1 ��m 1 x ��A ��f. ��,, � Fy N, Ad,'{9Yfk Y iri MA rr�•�.'IfiW�" 3N N R, �S r � h ,Y3t t C �x ag WTI- mac• • r • PARTIAL 3RD FLOOR FRAMING PLAN- NORTH SCALE: 1/8" = 1' -0" EXTENT OF 6" CONC. SLAB w ! • • i • • • • • Y Y R • Y • Y • • • • 10K 5.8 Y • • • • r•7 . GuVRR w ••• • •Rr• • i II II II I! II 11 N 11 II � II II fl II II II II II II I ll II II II II II II II I II II c7 II Il C7 II Il II fl r II II II II II II III II I I I I 3SB- REVISION BY 1 1/29/04 PERI"1IT REVISION 2 4/19104 OWNER REVISION 3 618104 REVIEW 4 S/14/04 OWNER REVISION 5 11/5 /04 GENERAL REv1Sl0 6 2/11 /05 GENERAL REVISIChN 8 8/17/05 GENERAL REVISION t t q I�t ti 1 ��m 1 x ��A ��f. ��,, � Fy N, Ad,'{9Yfk Y iri MA rr�•�.'IfiW�" 3N N R, �S r � h ,Y3t t C �x ag WTI- tfi"MriY MX - sKama r " v r:5 �i"x 15790 SW 88TH AVE MIAMI, FL 33157 AR 0017521 NOTE: ALL DRAWINGS FOR THIS PROJECT ARE TO BE READ IN CONJUNCTION WITH EACH OTHER. THESE INCLUDE, BUT ARE NOT LIMITED TO: ARCHITECTURAL, SURVEYING, STRUCTURAL, CIVIL, MECHANICAL, ELECTRICAL, SPECIALTY DRAWINGS, is WRITTEN SPECIFICATIONS. CONTRACTOR TO VERIFY ALL EXISTING SITE CONDITIONS AND THOROUGHLY CHECK ELEVATIONS AND DIMENSIONS BEFORE COMMENCING WORK. REPORT TO THE ARCHITECT ENGINEER ANY DISCREPANCIES, ERRORS OR CONDITIONS THAT WILL ALTER CONSTRUCTION AS INTENDED BY THESE DRAWINGS. ARCHITECT IS NOT RESPONSIBLE FOR ANY WORK AND /OR MATERIALS FURNISHED ON THE JOB. All graphic material appearing herein, unless indicated otherwise, are the property of the Architect as instruments of service for use solely on this project, and may not be duplicated, used or disclosed without the written consent of Marc E. Reardon, R.A. The architect retains all common law, statutory and other reserved rights. SEAL: r' • SNt El' RNANDEZ PE 46619 J f M/ 0 .• U. r IL LL LL 0 Z tz 0 00 .�• J LL x W _W Z W O > NORTH DRAWN BY: D.I. - E.0 - M.M DATE: 6/14/05 SCALE: AS NOTED SHEET NO.: cz 108