03-1559-057VERTICAL. PROVIDE 2 #6 VERT. ON EACH SIDE OF ALL OPENINGS BETWEEN 3'--0" AND 8' -0"
REINFORCE WALLS W/ #9 GAGE LADDER TYPE HORIZONTAL JOINT REINFORCEMENT ® 16" O.C.
ALL WALLS MUST BE GROUTED SOLID UP TO 2' -0" ABOVE SLAB.
2.— SEE M.E.P DRAWINGS FOR EXACT LOCATIONS OF ALL FLOOR OPENINGS.
3.— CONTRACTOR TO COORDINATE LOCATION OF PRECAST JOISTS WITH
ALL OTHER TRADES. SPACING SHOWN FOR PC JOISTS TO BE MAXIMUM.
4.— SEE ARCHITECTURAL DRAWINGS FOR ADDITIONAL DIMENSIONS &
INFORMATION.
5.— REFER TO ARCHITECTURAL DRAWINGS FOR INTERIOR NONBEARING WALLS, OPENINGS SIZES
AND LAYOUT, BALANCE OF DIMENSIONS, AND ADDITIONAL INFORMATION.
6.— TIE BEAM (TB) TO BE 8%12" W/2 #5 T&B AND #3012" STIRRUPS.
7.— REFER TO ARCHITECTURAL DRAWINGS FOR ADDITIONAL DIMENSIONS, INFORMATION INTERIOR WA -L
LAYOUT, MECHANICAL OPENINGS, SLAB DEPRESSIONS, OPENING SIZES AND OTHER INFORMATION.
8.— S -1 INDICATES 6" CONC. SLAB W/ #5012" 0/C EA WAY BOT.
9.— PROVIDE CORNERS BARS ON ALL TIE BEAM TO MATCH LONGITUDINAL REINFORCEMENT WITH
A SPLICE EQUAL TO 48 DIA.
10.— ALL COLUMNS SHALL TERMINATE WITH A STANDARD HOOK INTO TIE BEAM,2" FROM TOP OF BEAM.
11.— SPLICE ON TIE BEAM REINFORCEMENT TO BE 32" MINIMUM.
PARTIAL 3RD FLOOR FRAMING PLAN- NORTH
SCALE: 1/8" = 1' -0"
EXTENT OF 6" CONC. SLAB
w ! • • i • • • • • Y
Y R • Y • Y • • • •
10K 5.8 Y • • • •
r•7 . GuVRR w ••• • •Rr• •
i
II II
II I!
II 11
N 11 II
� II II
fl II
II II
II II
II
I ll II
II II
II II
II II
I II II c7
II Il C7
II Il
II fl
r II II
II II
II II
III II
I I I I 3SB-
REVISION BY
1 1/29/04 PERI"1IT REVISION
2 4/19104 OWNER REVISION
3 618104 REVIEW
4 S/14/04 OWNER REVISION
5 11/5 /04 GENERAL REv1Sl0
6 2/11 /05 GENERAL REVISIChN
8 8/17/05 GENERAL REVISION
t t q
I�t
ti
1 ��m
1 x
��A
��f.
��,,
�
Fy N, Ad,'{9Yfk Y iri MA rr�•�.'IfiW�" 3N
N R,
�S
r � h
,Y3t t C �x
ag
WTI-
mac•
• r •
PARTIAL 3RD FLOOR FRAMING PLAN- NORTH
SCALE: 1/8" = 1' -0"
EXTENT OF 6" CONC. SLAB
w ! • • i • • • • • Y
Y R • Y • Y • • • •
10K 5.8 Y • • • •
r•7 . GuVRR w ••• • •Rr• •
i
II II
II I!
II 11
N 11 II
� II II
fl II
II II
II II
II
I ll II
II II
II II
II II
I II II c7
II Il C7
II Il
II fl
r II II
II II
II II
III II
I I I I 3SB-
REVISION BY
1 1/29/04 PERI"1IT REVISION
2 4/19104 OWNER REVISION
3 618104 REVIEW
4 S/14/04 OWNER REVISION
5 11/5 /04 GENERAL REv1Sl0
6 2/11 /05 GENERAL REVISIChN
8 8/17/05 GENERAL REVISION
t t q
I�t
ti
1 ��m
1 x
��A
��f.
��,,
�
Fy N, Ad,'{9Yfk Y iri MA rr�•�.'IfiW�" 3N
N R,
�S
r � h
,Y3t t C �x
ag
WTI-
tfi"MriY
MX -
sKama r " v r:5 �i"x
15790 SW 88TH AVE
MIAMI, FL 33157
AR 0017521
NOTE:
ALL DRAWINGS FOR THIS PROJECT ARE
TO BE READ IN CONJUNCTION WITH
EACH OTHER. THESE INCLUDE, BUT
ARE NOT LIMITED TO: ARCHITECTURAL,
SURVEYING, STRUCTURAL, CIVIL,
MECHANICAL, ELECTRICAL, SPECIALTY
DRAWINGS, is WRITTEN SPECIFICATIONS.
CONTRACTOR TO VERIFY ALL EXISTING
SITE CONDITIONS AND THOROUGHLY
CHECK ELEVATIONS AND DIMENSIONS
BEFORE COMMENCING WORK.
REPORT TO THE ARCHITECT ENGINEER
ANY DISCREPANCIES, ERRORS OR
CONDITIONS THAT WILL ALTER
CONSTRUCTION AS INTENDED BY
THESE DRAWINGS. ARCHITECT IS
NOT RESPONSIBLE FOR ANY WORK
AND /OR MATERIALS FURNISHED
ON THE JOB.
All graphic material appearing herein,
unless indicated otherwise, are the
property of the Architect as
instruments of service for use solely
on this project, and may not be
duplicated, used or disclosed without
the written consent of Marc E.
Reardon, R.A. The architect retains
all common law, statutory and other
reserved rights.
SEAL:
r' • SNt El' RNANDEZ
PE 46619
J
f
M/
0
.•
U. r
IL
LL LL
0 Z
tz
0 00 .�•
J LL
x W
_W
Z W O >
NORTH
DRAWN BY:
D.I. - E.0 - M.M
DATE:
6/14/05
SCALE:
AS NOTED
SHEET NO.:
cz
108