Loading...
03-1559-052p "t ro 14.714. 14 13 12 11. 613' -3" 8' -11" 10 -1" 8' -0" • i • • Y Y N N ! ••N •r• • • • sees • • ► r . . • ••N • r r • r • • • • • a :0000 • • • r . *9000 • • • . •••• 0 • . . • r Y • • • N • sees • •►•Ir • •1• • N•r• • REVISION BY 1 1/29/04 PERMIT REVISION 2 4/19/04 OWNER REvISION 3 618104 REVIEW 4 9/14/04 OUNER RIE VISION 5 11/5 /04 GENERAL_ REVISION 6 2/11/05 GENERAL. REVISIO 8 5 /I1 /05 GENERAL R1= V1510N PROPERTY LINE : � c15 C15 — ---I -� — I SF -2 I I SF -2 -- - - -- .._ — ........7T - - - - -- � Y I REINFORCED MASONRY LEGEND !' - - - - -- .� ... ®.I.r:r - - - -� I I 8 RM 6 24 EF �I I I I N 7 I I L I I I I ,i I EACH FACE (WHERE APPLICABLE) , 303 I r- C4 r H I I �' I CENTER TO CENTER SPACING ...... ....... ............................... ....... �...... ....... �................ L.2 0 �..�--- .......- � ,_�.� s .................... L.2 ....I. I ... VERTICAL REINFORCING SIZE — 9' -10 1,L21 C1 I I 2 F -4 "I ` ..-1" REINFORCED MASONRY 4' (� BC1 NOMINAL MASONRY UNIT WIDTH F A I N I K � ----------- T N J.3 - -- - 0 I to C1 __ --- ----- W 0 I o> x_ I b T 7 C1 C1 W K 0 *3 J 70, SCALE: 1/8" = 1' -0" NOTES: 1 — SLAB ON GRADE TO BE 5" THICK OVER 10 MIL VAPOR BARRIER ON 95% COMPACTED FILL, REINFORCED WITH 6x6 — W2.102.1 W.W.F. (U.O.N.) 2 — REFER TO ARCHITECTURAL DRAWINGS FOR INTERIOR NONBEARING WALLS, OPENINGS SIZES AND LAYOUT, BALANCE OF DIMENSIONS, AND ADDITIONAL INFORMATION. 3 — TOP OF ALL FOOTINGS MUST BE AT LEAST 1' -4" BELOW SLAB OR PAVEMENT. 4 -- ALL EXTERIOR WALLS TO BE 8" THK. CMU, REINFORCED W/ #6032" MAXIMUM SPACING VERTICAL. PROVIDE 2 #5 VERT. ON SIDES OF ALL OPENINGS BETWEEN 3' -0" AND 8' -0 ". REINFORCE WALLS W/ #9 GAGE LADDER TYPE HORIZONTAL JOINT REINFORCEMENT AT 16" O.C. EXCEPT BELOW WINDOW OPENINGS WHERE JOINT REINFORCEMENT MUST BE PROVIDED 0 8" O.C., EXTENDING AT LEAST 2' -0" BEYOND OPENING. ALL WALLS NEIGHBORING GARAGE MUST BE GROUTED SOLID UP TO 2' -0" ABOVE F /F. 5 — TOP OF SLAB ON GRADE INDICATED THUS 6 — ALL VERTICAL BARS MUST TERMINATE WITH A STANDARD HOOK 3" FROM BOTTOM OF FOOTING. 7 — SPLICE ON FOOTINGS REBARS MUST BE 36" MINIMUM. 8 — PROVIDE CORNER BARS AS INDICATED ON DETAIL 5/S -201. 9 — REFER TO SCHEDULES BELOW FOR FOOTING SIZES AND REINFORCEMENT. 10— ALL INTERIOR CMU WALLS TO BE REINFORCED W/ #6 0 24" O.C. VERT. AND #9 GAGE HORIZ. JOINT REINF. 0 8" O.C. EMMERERS MC. 13392 SOUTH WEST 128 STREET MIAMI FLCRIDA 33186 PHONE: 305- 971 —GFCE FAX: 305 - 971 -4332 E —MAIL: GFCE@GFCF.NET CERTIFICATE OF AUTHORIZATION #9129 15790 SW 88TH AVE MIAMI, FL 33157 AR 0017521 NOTE: ALL DRAWINGS FOR THIS PROJECT ARE TO BE READ IN CONJUNCTION WITH EACH OTHER. THESE INCLUDE, BUT ARE NOT LIMITED TO: ARCHITECTURAL, SURVEYING, STRUCTURAL, CIVIL, MECHANICAL, ELECTRICAL, SPECIALTY DRAWINGS, & WRITTEN SPECIFICATIONS. CONTRACTOR TO VERIFY ALL EXISTING SITE CONDITIONS AND THOROUGHLY CHECK ELEVATIONS AND DIMENSIONS BEFORE COMMENCING WORK. REPORT TO THE ARCHITECT ENGINEER ANY DISCREPANCIES, ERRORS OR CONDITIONS THAT WILL ALTER CONSTRUCTION AS INTENDED BY THESE DRAWINGS. ARCHITECT IS NOT RESPONSIBLE FOR ANY WORK AND /OR MATERIALS FURNISHED ON THE JOB. All graphic material appearing herein, unless indicated otherwise, are the property of the Architect as instruments of service for use solely on this project, and may not be duplicated, used or disclosed without the written consent of Mark E. Reardon, R.A. The architect retains all common law, statutory and other reserved rights. AIL: It R �n7 ti,.:`or�• a� k ti "s 1 i FIR S,v -"E. HERNANDEZ FLORIDA �E 4fiG1• J V/ .. W J OC >N WO zmN U D L 06 LL 0 0 UL 0z Ix Z A 00 LL CD W a X LU z 0n0 2 ►•: i DRAWN BY: D. 1. - E.0 - M.M DATE: 6/1+4/05 SCALE: AS NOTED SHEET NO.: S103