Loading...
03-1559-049A l r 1 I1� •00• ••• • • ••i0• 60• • •�• • i Y sees: ••• ••W • • 0 0000 • • • Y W J • • • V V N V,* • Y J C3 E=l F:;Z P�k (D :**so • Y • • • '000, • q .009 •• Y• V W• V .... v V v v V V .. � 00200 BUILDING CODES: THE GOVERNING CODE FOR THIS PROJECT IS: FLORIDA BUDDING CODE - 2001 EDITION TO THE BEST OF OUR KNOWLEDGE, THE STRUCTURAL PLANS, AND SPECIFICATIONS COMPLY WITH THE APPLICABLE REQUIREMENTS OF THE GOVERNING CODES. 01100 SCOPE OF SERVICE: THE STRUCTURAL ENGINEER OF RECORD HAS DESIGNED AND IS RESPONSIBLE FOR ONLY THE SPECIFIC STRUCTURAL COMPONENTS SHOWN IN THIS SET OF STRUCTURAL CONSTRUCTION DOCUMENTS. IF A SPECIALTY ENGINEER, AS DEFINED BY THE DEPARTMENT OF PROFESSIONAL REGULATION, IS REQUIRED, HIS SERVICES MUST COMPLY WITH THE SCOPE OF SERVICES AS OUTLINED IN THE PROJECT CONSTRUCTION DOCUMENTS. 00500 STRUCTURAL LOADING: THE STRUCTURE HAS BEEN DESIGNED IN ACCORD WITH THE BUILDING CODE AND /OR MORE RESTRICTIVE REQUIREMENTS FOR LOADS AS GIVEN BELOW UNLESS SPECIFIC AREAS OF THE DRAWING SPECIFICALLY CALL FOR DIFFERENT LOADING CRITERIA. REFER TO DRAWINGS FOR LOAD SCHEDULE. GRAVITY LOADING: UNIFORM LIVE LOAD OFFICES _ -_ _ ----- _.- ..... -__ ___ - - - - _.._ ._ __ 50 PSF PARKING - - -. - - - - - - �w � _.._ _._ _.._ - - _.. W. _ 50 PSF PATH OF EGRESS - COMMERCIAL .---- - - - - - - ._..._._ _.._ _ 100 PSF ROOFSSLOPED..... ....... .................... ..................... _ ..... ....... ....... ....... ..... 20 PSF FLAT - __ _ _ _ _ - 30 PSF WIND LOAD AS PER ASCE 7­98 (WIND VELOCITY 146 MPH) 1 =1.00 01051 DRAWING DIMENSIONS AND COORDINATION: DIMENSIONAL INFORMATION, PRICING, ALL DETAILS AND CONSTRUCTION SHALL BE BASED ON THE ENTIRE SET OF CONTRACT DOCUMENTS. COORDINATE THE REQUIREMENTS OF ALL PROFESSIONALS. USE INFORMATION FROM APPROVED SHOP DRAWINGS TO SUPPLEMENT CONTRACT DOCUMENTS WHERE NECESSARY. REPORT ANY DISCREPANCIES TO THE ARCHITECT PRIOR TO PROCEEDING. IF A CONFLICT EXISTS, THE MORE STRINGENT GOVERNS. WHERE CRITICAL DIMENSIONS CANNOT BE DETERMINED FROM THE PLANS, OR WHERE NEW WORK ADJOINS EXISTING CONSTRUCTION, OR WHERE ONE MATERIAL ADJOINS A PREVIOUSLY PLACED MATERIAL WITH A MORE RESTRICTIVE TOLERANCE THAN THE IN -PLACE MATERIAL, CONTRACTOR SHALL TAKE FIELD MEASUREMENTS AS REQUIRED TO COMPLETE SHOP DRAWINGS AND INSTALLATION. REPORT ANY DISCREPANCIES EXCEEDING 3% BETWEEN FIELD MEASURED DIMENSIONS AND SCALED DRAWING DIMENSIONS TO ARCHITECT BEFORE PROCEEDING WITH WORK. DO NOT SCALE DRAWINGS; USE DIMENSIONS. WHERE A LINE OF STRUCTURE, OPENING LOCATION, OR DIMENSION IS CRITICAL AND BASED ON THE REQUIREMENTS OF ANOTHER TRADE OR SUBCONTRACTOR, THAT SUBCONTRACTOR SHALL SUBMIT A SHOP DRAWING WITH THE REQUIRED DIMENSIONAL INFORMATION UPON WHICH THE CONTRACTOR SHALL BASE THE LAYOUT" AND CONSTRUCTION. THIS PROCEDURE IS MANDATORY FOR CURTAIN WALL SYSTEMS, ARCHITECTURAL PRECAST SYSTEMS, AND ALL MECHANICAL AND ELECTRICAL OPENINGS. THE ENGINEER WILL CLOUD OR OTHERWISE INDICATE REVISIONS TO THESE DOCUMENTS ONLY AFTER THEY HAVE BEEN ISSUED FOR CONSTRUCTION OR FINAL PRICING. CHANGES PRIOR TO THAT DATE WILL NOT BE CLOUDED. CHANGES AND /OR REVISIONS AFTER THE CONSTRUCTION OR FINAL PRICING ISSUE WILL BE CLOUDED IN AN ATTEMPT TO BRING TO THE CONTRACTOR'S ATTENTION ANY MAJOR ITEMS, HOWEVER, IT SHALL BE SOLELY THE CONTRACTORS RESPONSIBILITY TO COORDINATE THE PRICING AND CONSTRUCTION OF ALL REQUIREMENTS OF THESE DOCUMENTS, INCLUDING REVISIONS (FLAGGED OR UN- FLAGGED) WITH ALL OF HIS SUPPLIERS AND SUBCONTRACTORS. REVISIONS ARE IDENTIFIED BY A REVISION NUMBER WITHIN A TRIANGLE. ALL REVISIONS ISSUED ON A SINGLE DATE WILL BE IDENTIFIED BY THE SAME NUMBER. CONSTRUCTION TO COMPLY WITH REQUIREMENTS OF THE GOVERNING BUILDING CODE, AND ALL OTHER APPLICABLE FEDERAL, STATE, AND LOCAL CODES, STANDARDS, REGULATIONS AND LAWS. DETAILS LABELED AS "TYPICAL DETAILS" ON DRAWINGS AND DETAIL SHEETS, APPLY TO ALL SITUATIONS THAT ARE SIMILAR OR SAME AS THOSE SPECIFICALLY DETAILED. SUCH DETAILS APPLY WHETER OR NOT THEY ARE KEYED AT EACH LOCATION ON PLAN DRAWINGS. QUESTIONS REGARDING APPLICABILITY OF DETAILS SHALL BE RESOLVED BY THE ARCHITECT OR ENGINEER. 01400 STRUCTURAL FRAME INSPECTION: OWNER TO EMPLOY A REGISTERED INSPECTOR TO PERFORM THE DUTIES REQUIRED BY THE LOCAL BUILDING CODE. INSPECTOR SHALL PROVIDE A STATEMENT OF INSPECTION AS REQUIRED BY GOVERNING CODES, WHICH CERTIFIES THAT THE STRUCTURE AND ENVELOPE COMPONENTS ARE IN COMPLIANCE WITH THE APPROVED PERMIT DOCUMENTS. 01800 SHOP DRAWINGS do STRUCTURAL SUBMITTALS: SUBMIT TO THE STRUCTURAL ENGINEER FOUR ORIGINALS ONLY AFTER THEY HAVE BEEN REVIEWED BY THE CONTRACTOR. IF ADDITIONAL COPIES OF ANY MATERIAL ARE REQUIRED, PLEASE PROVIDE SUCH. HOWEVER, ONLY THREE MARKED COPIES WILL BE RETURNED BY THE STRUCTURAL ENGINEER. UNDER NO CIRCUMSTANCES WILL THE USE OF STRUCTURAL DRAWINGS PREPARED BY GF CONSULTING ENGINEERS INC. BE PERMITTED FOR SHOP DRAWING OR BACKGROUND USE. THIS INCLUDES BOTH PHOTOGRAPHIC AND ELECTRONIC REPRODUCTION. SHOP DRAWINGS SHALL BE PREPARED ENTIRELY BY THE VENDOR OR SUBCONTRACTOR GENERATING SUCH SUBMITTAL. THE USE OF ANY DRAWING PREPARED BY GF CONSULTING ENGINEERS INC. AS BACKGROUND INDICATES ACCEPTANCE OF TERMS AND CONDITIONS BY GF CONSULTING ENGINEERS INC. FOR THEIR USE, AND STIPULATED COMPENSATION MUST BE DELIVERED TO GF CONSULTING ENGINEERS INC. PRIOR TO SUBMITTAL OF SHOP DRAWINGS, OTHERWISE, SHOP DRAWINGS WILL BE RETURNED NON REVIEWED. REVIEW OF ADDITIONAL SUBMITTALS WILL BE CONSIDERED ADDITIONAL SERVICES, FOR WHICH THE CONTRACTOR MAY BE HELD RESPONSIBLE, THOSE ADDITIONAL SERVICES FEES WILL BE IN ACCORDANCE WITH THE TERMS OF THE ARCHITECT -GFCE AGREEMENT FOR THIS PROJECT. GFCE WILL MARK ONLY TWO SETS OF DRAWINGS REGARDLESS OF HOW MANY COPIES HAD BEEN SUBMITTED, ONLY AFTER DRAWINGS BEAR EVIDENCE OF BEEN REVIEWED AND APPROVED BY THE CONTRACTOR. SHOP DRAWINGS SUBMITTED TO GFCE WITHOUT CONTRACTORS APPROVAL WILL BE RETURNED UNREVIEWED. REVIEW OF SHOP DRAWINGS IS NOT CONDUCTED FOR DETERMINING THE ACCURACY AND COMPLETENESS OF DETAILS QUANTITIES OR FOR SUBSTANTIATING FABRICATION INSTALLATION INSTRUCTION OR PERFORMANCE OF EQUIPMENT OF SYSTEM, ALL OF WHICH SHALL REMAIN THE SOLE RESPONSIBILITY OF THE CONTRACTOR. REVIEW OF SHOP DRAWINGS DOES NOT CONSTITUTE APPROVAL OF SAFETY PRECAUTIONS, CONSTRUCTION MEANS, METHODS, SEQUENCES OR PROCEDURES, NOR DOES IT INDICATE APPROVAL OF ASSEMBLY OF WHICH THE ITEM IS A COMPONENT. COORDINATION OF ALL TRADES SHALL REMAIN THE SOLE RESPONSIBILITY OF THE CONTRACTOR. CONTRACTOR MUST REVIEW ALL QUANTITIES AND DIMENSIONS. ALLOW ADEQUATE TIME FOR TRANSIT,AND PROCESSING BEFORE FABRICATION. GF CONSULTING ENGINEERS WILL REVIEW AN AVERAGE SUBMITTAL WITHIN 15 CALENDARS DAYS OF RECEIPT. REVIEW OF SHOP DRAWINGS IS LIMITED TO TWO REVIEWS PER SUBMITTAL WITHIN THE SCOPE OF BASIC SERVICES, THAT IS ONE INITIAL REVIEW AND ONE ADDITIONAL REVIEW ONCE MARKED ITEMS HAVE BEEN CORRECTED. SPECIALTY OR DELEGATED ENGINEERING SHOP DRAWINGS: BY DEFINITION A DELEGATED ENGINEER IS A FLORIDA REGISTERED PROFESSIONAL ENGINEER NOT THE STRUCTURAL ENGINEER OF RECORD, WHO SPECIALIZES IN AND WHO UNDETAKES THE DESIGN OF STRUCTURAL COMPONENTS OR STRUCTURAL SYSTEMS INCLUDED IN A SPECIFIC SUBMITTAL PREPARED FOR THIS PROJECT. THE DELEGATED OR SPECIALTY ENGINEER SHALL BE AN EMPLOYEE OR OFFICER OF A FABRICATOR, AN EMPLOYEE OR OFFICER OF AN ENTITY SUPPLYING COMPONENTS TO A FABRICATOR, OR AN INDEPENDENT CONSULTANT RETAINED BY THE FABRICATOR OR HIS SUPPLIER. SUBMITTALS AND RE- SUBMITTAL FOR CUSTOM DESIGNED, MANUFACTURED OR FABRICATED LOAD- CARRYING MEMBERS, COMPONENTS OR ITEMS, SUBJECT TO FORCES OR STRESSES AND THEIR CONNECTIONS OR ANCHORAGE REQUIRE A DELEGATED OR SPECIALTY ENGINEER. THE FOLLOWING SYSTEMS AND COMPONENTS REQUIRE FABRICATION, AND ERECTION DRAWINGS ALONG WITH SIGNED AND SEALED CALCULATIONS BY A DELEGATED ENGINEER: - ALUMINIUM OR LIGHT GAGE STEEL EXTERIOR WALL SYSTEMS - GLAZING AND STORE FRONT SYSTEMS, INCLUDING MULLIONS do CONNECTIONS - POST - TENSIONED CONCRETE MEMBERS - PREFABRICATED WOOD TRUSSES - PRECAST CONCRETE COMPONENTS: WALLS, COLUMS, JOISTS -- CONCRETE TILT -UP WALLS AND COMPONENTS - SHORING AND RE-- SHORING DRAWINGS ALL SUBMITTALS SHALL CLEARLY IDENTIFY THE SPECIFIC PROJECT AND APPLICABLE CODES, AS WELL AS THE DESIGN CRITERIA WHICH SHOULD NOT BE IN CONFLICT WITH THOSE SPECIFIED ON THE CONTRACT DOCUMENTS, THE APPLICABLE BUILDING CODE NOR THE SPECIFICATIONS. IN CASE OF CONFLICT REQUEST FOR CLARIFICATION MUST BE SUBMITTED IN WRITTING TO A /E, OR THE MOST STRINGENT CRITERIA MUST BE USED. SUBMITTAL MUST SHOW ALL DETAILS, PLANS AND NECESSARY INFORMATION FOR THE PROPER FABRICATION AND INSTALLATION OF SYSTEM OR COMPONENTS. CALCULATIONS AND DRAWINGS MUST CLEARLY IDENTIFY SPECIFIC PRODUCTS UTILIZED SINCE GENERIC PRODUCTS WILL NOT BE ACCEPTED. CATALOG INFORMATION ON STANDARD PRODUCTS DOES NOT REQUIRE THE SEAL OF A DELEGATED ENGINEER. ALL SHOP DRAWINGS AND CALCUALTIONS MUST BEAR THE IMPRESSED SEAL, DATE AND SIGNATURE OF THE DELEGATED OR SPECIALTY ENGINEER. IN CASE THAT COMPUTER PRINT -OUTS ARE SUBMITTED THOSE MUST BE ACCOMPANIED WITH DESCRIPTIVE INFORMATION AS OF THE INPUT AND OUTPUT FOR THEIR PROPER EVALUATION. SUCH DESCRIPTION OF COMPUTER PRINT -OUTS MUST BE SIGNED AND SEALED AS WELL WITH A NOTE INDICATING FULL ACCEPTANCE AND LIABILTY OVER THE RESULTS OF SAID COMPUTER PROGRAM. REVIEW BY GFCE /SE OR OF SUBMITTALS IS LIMITED TO VERIFYING THAT THE SPECIFIC STRUCTURAL SUBMITTAL HAVE BEEN FURNISHED; THAT THE STRUCTURAL SUBMITTAL HAVE BEEN SIGNED AND SEALED BY THE DELEGATED ENGINEER; THAT THE SPECIFIED CRITERIAS, AND DESIGN INTENT HAVE BEEN FOLLOWED AND UNDERSTOOD BY THE DELEGATED ENGINEER; AND THAT THE CONFIGURATION SET FORTH IN THE STRUCTURAL SUBMITTAL IS CONSISTENT WITH THE CONTRACT DOCUMENTS. NO DETAILED CHECK OF DIMENSIONS OR QUANTITIES WILL BE MADE SINCE THIS IS TO BE PERFORMED BY THE GENERAL CONTRACTOR. SUBMITTALS NOT MEETING THE ABOVE CRITERIA WILL BE RETURNED NON REVIEWED. 02000 FOUNDATIONS: GEOTECHNICAL DATA AND RECOMMENDATIONS HAVE BEEN PROVIDED BY: ARDAMAN & ASSOCIATES, INC. REPORT # 01 -3694 , DATED MAY 4, 2001 BASED ON THEIR RECOMMENDATIONS, THE FOLLOWING FOUNDATION SYSTEM WILL BE USED: SHALLOW FOUNDATION: 5000 PSF SOIL BEARING CAPACITY GEOTECHNICAL ENGINEER IS RESPONSIBLE FOR SPECIFYING AND MONITORING ALL TESTING, INSTALLATION, EVALUATION, AND REPORTING RELATED TO THE FOUNDATION SYSTEM, INCLUDING ALL WORKMANSHIP PROVISIONS RELATING TO THE SOIL - STRUCTURE INTERFACE. THE STRUCTURAL ENGINEER IS RESPONSIBLE FOR SPECIFYING THE MATERIALS USED TO CONSTRUCT THE FOUNDATION UNITS AND FOR THE SELECTION OF VARIOUS SIZE UNITS TO SUPPORT THE STRUCTURAL FRAME. THE CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING APPROVAL FROM GEOTECHNICAL ENGINEER PRIOR TO PLACEMENT OF ANY FOUNDATION ELEMENTS OVER PREPARED SUBGRADE AND /OR DEEP FOUNDATION ELEMENTS. THE GEOTECHNICAL REPORT FORMS INTEGRAL PART OF THESE DOCUMENTS AND ALL RECOMMENDATIONS CONTAINED SHALL BE STRICTLY FOLLOWED. 02200 EARTHWORK: CONTRACTOR SHALL DEWATER SITE AS NECESSARY, SO THAT ALL CONCRETE CAN BE PLACED IN THE DRY. ALL BACKFILL SHALL BE ACCOMPLISHED USING MATERIAL CONSISTING OF CRUSHED STONE AND /OR MATERIAL APPROVED BY THE GEOTECHNICAL ENGINEER. THE BACKFILL SHALL BE COMPACTED TO 957 OF MAXIMUM DENSITY AS DETERMINED BY ASTM D -1557. NO BACKFILL MATERIAL SHALL BE PLACED AGAINST WALLS WHICH DO NOT HAVE PERMANENT FLOORS AT THE TOP AND BOTTOM WITHOUT PROVISIONS FOR ADEQUATE TEMPORARY BRACING OF THOSE WALLS. PROVIDE ADEQUATE EXCAVATION BRACING IN ACCORD WITH GEOTECHNICAL ENGINEER RECOMMENDATIONS TO MAINTAIN EXISTING FOOTINGS, UTILITIES, AND OTHER IMPROVEMENTS IN A SAFE CONDITION. 02210 STRUCTURAL FILL: FOUNDATIONS PLACED ON COMPACTED LIMEROCK STRUCTURAL FILL HAVE BEEN DESIGNED FOR A BEARING OF 2000 PSF. FILL TO BE COMPACTED TO 95% OF MAXIMUM DENSITY AS DETERMINED BY ASTM D -1557. PLACE FILL IN LAYERS OF 6" THICK MAXIMUM AND UNDER THE DIRECT SUPERVISION OF A GEOTECHNICAL ENGINEER. SOIL COMPACTION AND FILL PLACEMENT SHALL BE CONTROLLED AND MONITORED BY CERTIFIED TESTING AGENCY. TAKE A MINIMUM OF 2 FIELD DENSITY TESTS (ASTM D -1556 OR ASTM D -2922) FOR EACH LAYER OF FILL. THE TESTING AGENCY SHALL RANDOMLY SELECT TEST LOCATIONS. EACH LAYER OF FILL MUST BE COMPACTED BEFORE PLACEMENT OF THE NEXT. USE FILL CONTAINIG NOT MORE THAN 10% PASSING #200 SIEVE AND MAXIMUM 1 INCH. BOTTOM OF EXCAVATIONS MUST BE COMPACTED WITHA WALK - BEHIND VIBRATORY SLED OR ROLLER HAVING A MINIMUM STATIC WEIGHT OF 240# WITH CENTRIFUGAL FORCE OF 300 LBS. AND A MAXIMUM STATIC WEIGHT OF 1000 LBS WITH A CENTRIFUGAL FORCE OF 5000 LBS. COMPACT UNTIL SOIL 1 FT BELOW COMPACTION SURFACE REACHES A DRY DENSITY OF 957 OF MAXIMUM AS DETERMINED BY A MODIFIED PROCTOR (ASTM D- 1557). TAKE A MINIMUM OF 1 DENSITY TEST (ASTM D -1556 OR ASTM D -2922) FOR EACH SPREAD FOOTING, AND FOR EACH 25 FEET OF CONTINUOS FOOTING. SOIL COMPACTION MUST BE FIELD CONTROLLED AND MONITORED BY A CERTIFIED TESTING AGENCY OR GEOTECHNICAL ENGINEER OF RECORD. DENSITY TEST REPORTS MUST BE AT THE SITE PRIOR TO REINFORCEMENT INSPECTION. IF SOIL IS DISTURBED DURING FOOTING EXCAVATION OR AFTER EXCAVATION HAD BEEN COMPLETED, RE- COMPACTION AS DESCRIBED ABOVE MUST BE DONE. 02240 EXCAVATION: STRIP TOP SOIL ( MINIMUM 6 INCHES) AT LEAST FIVE FEET PAST EXTERIOR BUILDING LINES. ALL DELETERIOUS MATERIAL MUST BE COMPLETELY REMOVED, INCLUDING EXISTING FOUNDATIONS OF DEMOLISHED BUILDINGS. DO NOT EXCAVATE FOR ANY PURPOSE WITHIN ONE FOOT OF THE ANGLE OF REPOSE OF ANY SOIL BEARING FOOTING OR FOUNDATION UNLESS SUCH FOOTING OR FOUNDATION IS FIRST PROPERLY UNDERPINNED OR OTHERWISE PROTECTED AGAINST SETTLEMENT. GENERAL CONTRACTOR IS RESPONSIBLE FOR THE DISPOSAL OF ALL ACCUMULATED WATER FROM EXCAVATION AND DEWATERING OPERATION IN SUCH A MANNER AS TO ENSURE PROPER CONCRETE PLACEMENT AND PREVENT DAMAGE TO STRUCTURAL ELEMENTS. THE GENERAL CONTRACTOR IS SOLELY RESPONSIBLE FOR ALL EXCAVATION PROCEDURES INCLUDING LAGGING, SHORING, SHEET PILING, AND PROTECTION TO ADJACENT PROPETIES, STRUCTURES, STREET, UTILITIES IN ACCORDANCE WITH THE REQUIREMENTS OF THE LOCAL BUILDING DEPARTMENT AND ALL OSHA REGULATIONS. 03100 CONCRETE FORMWORK: CONTRACTOR SHALL DESIGN AND ERECT FORMWORK IN STRICT COMPLIANCE WITH ACI 347R -94. SEE TYPICAL DETAILS FOR CAMBER REQUIREMENTS. CONTRACTOR SHALL COORDINATE ALL OPENINGS AS REQUIRED FOR OTHER TRADES. OPENINGS WHERE SHOWN ON THE STRUCTURAL DRAWINGS ARE TO IDENTIFY DESIGN INTENT ONLY. THE SPECIFIC DIMENSIONS AND LOCATIONS SHALL BE FURNISHED OR CONFIRMED BY THE TRADE REQUIRING THE OPENING. PROVIDE CHAMFERS AT ALL CORNERS IN CONCRETE MEMBERS EXPOSED TO VIEW. FORMWORK TO REMAIN IN PLACE UNTIL CONCRETE HAS ATTAINED ENOUGH STRENGTH TO SUPPORT ALL DEAD LOADS PLUS A MINIMUM OF 50 PSF OF ADDITIONAL CONSTRUCTION LOAD. SEE SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS. 03110 SHORING & RESHORING: CONTRACTOR MUST PROVIDE SHORING AND RESHORING DRAWINGS PREPARED BY A DELEGATED ENGINEER AND CONFORMING TO THE REQUIREMENTS OF SECTION 3100 "CONCRETE FORMWORK ". DESIGN FORMS AND SHORES FOR HORIZONTAL CONCRETE MEMBERS FOR NOT LESS THAN DEAD LOAD PLUS 50 PSF CONSTRUCTION LOAD AND FOR THE CUMULATIVE LOADS OF SUPPORTED FLOORS. DESIGN WOOD SHORES WITH A MINIMUM SAFETY FACTOR OF 3, AND METAL SHORES WITH A MINIMUM SAFETY FACTOR OF 2. THE MAXIMUM SUPERIMPOSED CONSTRUCTION LOAD APPLIED TO FLOORS SUPPORTING SHORES OR RESHORES SHALL BE 7 OF THE LIVE LOAD SPECIFIED FOR SLABS AND JOISTS AND 60 NOT EXCEED 757 OF THE LIVE LOAD SPECIFIED FOR BEAMS. NO CONSTRUCTION LOAD SHALL BE APPLIED TO ANY MEMBER UNTIL THE CONCRETE IS A MINIMUM OF 7 OF THE SPECIFIED 28 DAYS STRENGTH. 14 DAYS OLD AND THE 7 DAYS STRENGTH IS 70 REMOVAL OF FORMWORK IS THE SOLE RESPONSIBILITY OF THE CONTRACTOR. REMOVE FORMS IN SUCH A MANNER TO INSURE JOB SAFETY AND TO PREVENT DAMAGE TO AND CREEP DEFLECTION OF THE STRUCTURE. FOLLOW THE MINIMAL GUIDELINES FOR REMOVAL OF HORIZONTAL FORMS INDICATED BELOW: -- -SLABS WITH SPANS LESS THAN 5' -0 ", FORMS MAY BE REMOVED 24 HOURS AFTER COMPLETING CONCRETE POUR. NO STRENGTH VERIFICATION IS REQUIRED, UNLESS AIR TEMPERATURE HAD FALLEN BELOW 60' F. DURING THE 24 HRS PERIOD. NO RESHORING IS REQUIRED. -SLABS BETWEEN 5' ---0" AND 10' -0 ", FORMS MAY BE REMOVED 72 HRS AFTER COMPLETING CONCRETE POUR, 7 OF SPECIFIED 28 DAYS DESIGN STRENGTH. RESHORING NECESSARY. PROVIDED IS AT LEAST 70 DO NOT REMOVE SHORING UNTIL CONCRETE HAS REACHED A MINIMUM COMPRESSIVE STRENGTH OF 2800 PSI AS A MINIMUM, SHORING AND RESHORING SHALL REMAIN IN PLACE AS FOLLOWS: - BEAMS: SHORES: 7 DAYS RESHORES: 14 DAYS - JOISTS: SHORES: 72 HRS RESHORES: 14 DAYS - CANTILEVER SLAB: SHORES. 7 DAYS RESHORES: 14 DAYS - CANTILEVER BEAM: SHORES: 7 DAYS RESHORES: 14 DAYS. THE SHORING AND RESHORING MUST BE INSPECTED BY THE DELEGATED ENGINEER OR HIS AUTHORIZED REPRESENTATIVE PRIOR TO EACH CONCRETE POUR AND SUBMIT A WRITTEN SIGNED AND SEALED REPORT TO THE THRESHOLD OR SPECIAL INSPECTOR AND TO THE CONTRACTOR STATING THAT THE WORK IS IN GENERAL COMPLIANCE WITH HIS /HER SHORING RESHORING DRAWINGS. COPIES OF THE FIELD REPORTS MUST BE SUBMITTED TO THE ARCHITECT, THE OWNER, THE GENERAL CONTRACTOR, THE BUILDING OFFICIAL AND TO GFCE ON A BI-- WEEKLY BASIS. THE REPORTS MUST CLEARLY INDICATE ANY ITEMS REQUIRING CORRECTIONS, ACCEPTED DEVIATION FROM SHORING DRAWINGS, ANY SKETCHES SUBMITTED TO CORRECT DEFICIENCIES, AND AREAS ACCEPTED AND RELEASED FOR CONCRETE POURS. NO GENERIC LETTER WILL BE ACCEPTED, THUS REPORT MUST CLEARLY INDICATE NAME AND LOCATION OF PROJECT, DATE AND TIME AS WELL AS WORKING CONDITION DURING INSPECTION INCLUDING WEATHER AND TEMPERATURE. REINFORCED MASONRY LEGEND 8 RM 6 24 EF LEACH FACE ( WHERE APPLICABLE) CENTER TO CENTER SPACING VERTICAL REINFORCING SIZE REINFORCED MASONRY NOMINAL MASONRY UNIT WIDTH INDEX DRAWINGS S -001 GENERAL NOTES AND INDEX S -002 GENERAL NOTES S -101 PARTIAL FOUNDATION do GROUND FLOOR PLAN S -102 PARTIAL FOUNDATION & GROUND FLOOR PLAN S -103 PARTIAL FOUNDATION do GROUND FLOOR PLAN S -104 PARTIAL SECOND FLOOR FRAMING PLAN S -105 PARTIAL SECOND FLOOR FRAMING PLAN S -106 PARTIAL SECOND FLOOR FRAMING PLAN S -107 PARTIAL THIRD FLOOR FRAMING PLAN S -108 PARTIAL THIRD' FLOOR FRAMING PLAN S -109 PARTIAL THIRD FLOOR FRAMING PLAN S -110 4TH AND 5TH FLOOR FRAMING PLAN S -111 ROOF FRAMING PLAN S -201 FOUNDATION DETAILS S ---202 FOUNDATION DETAILS S -203 FOUNDATION AND CONC. COLUMN SHEDULES S -401 SOFFIT BEAM SCHEDULE S -402 CONC. BEAM AND P/C JOIST SCHEDULES AND DETAILS S -403 SHEAR WALL ELEVATIONS S -501 WINDOW WIND LOAD S ---502 WINDOW WIND LOAD ii • • • • • • • V • V • ►�,�,,,. ��` i~ tip �r'`�•,', jjl . , ,�,. Ala.. "• G C`uls na-.1"K [Emanm in's tj �I 13392 SOUTH WE=ST 128 STREET MIAMI FLORIDA :'13186 PHONE: 305 - 971 -GFCE Q FAX: 305 - 971 -4332 E -MAIL: GFCEQGFCE.NET CFRTIFICATE OF AUTHORIZATION #9129 S --301 FRAMING DETAILS S -302 FRAMING DETAILS i S -303 FRAMING DETAILS S -304 FRAMING DETAILS S -305 FRAMING DETAILS S -306 FRAMING DETAILS S--307 FRAMING DETAILS S -401 SOFFIT BEAM SCHEDULE S -402 CONC. BEAM AND P/C JOIST SCHEDULES AND DETAILS S -403 SHEAR WALL ELEVATIONS S -501 WINDOW WIND LOAD S ---502 WINDOW WIND LOAD ii • • • • • • • V • V • ►�,�,,,. ��` i~ tip �r'`�•,', jjl . , ,�,. Ala.. "• G C`uls na-.1"K [Emanm in's tj �I 13392 SOUTH WE=ST 128 STREET MIAMI FLORIDA :'13186 PHONE: 305 - 971 -GFCE Q FAX: 305 - 971 -4332 E -MAIL: GFCEQGFCE.NET CFRTIFICATE OF AUTHORIZATION #9129