03-1559-036LIFE SAFETY LEGEND
NEW CMU WALL PER STRUCT PLUG'S W/ STUCCO FIN.
® TO MATCH EXIST. AND R -42 FOIL iN5UL AND 112"
GYP. ED.
NEW 2 HR RATED INTERIOR PARTITION W/ 20 GA,
4
ATTENUATING NG NDSUL. W5/SGGYP 5DUEACH SIDE.
Lu I NEW 1 HR RATED INTERIOR PARTITION W/ 20 GA.
3-5/8" MTL STUDS * 24' O.C. t 3" SOUND
ATTENUATING INSUL. W/ 5/8" GYP. BD. EACH SIDE.
NEW INTERIOR PARTITION W/ 20 GA. 3 -5/8" MTL.
' STUDS 10 24' O.G. 4 3" SOUND ATTENUATING INSUL -
v I W/ 5/8" GYP. BD. EACH SIDE.
CIE SEMI- RECESSED 10 LE- ABC RATED
FIRE EXTINGUISHER IN CABINET.
�I
e EXIT SIGN SEE ELEC. PLANS.
(TYP.) I PROPERTY LINE (TYP.) _ _ _
1
TOTAL DISTANCE TOTAL DISTANCE
To LOBE`►' EXIT = 112' -3" , TO LOBBY EXIT 134' -6"
TO STAIR No 2 = 133' -10" TO STAIR No 2 = 42'--1-
------ ...... —�
Q ,
I i STAIR No 2
STAIR CAPACITY= 1 TAIR
- 160 OCCUPANTS I NO, 2
c�
I1
OFFICE AREA -
" I�
---- .-..-..—._...._.----- . —. - - -- I�
— 34, PROVIDE SIGN ON
I DOOR STATING i L �
'" Q
I m 0P ��
NOT AN EXIT G t�
ELECTRIC 11 7ELEV
I I� �I EIJLn E V ELEVATOR M
ACW.
onnM I
_ 1-10 OCCUPANTS 1
— - -- — — -- - - -- — — — ---------- - - - --- - - -- -- — -- ----------- - - - - -- — — -- -- - - -- — --- - - - - --
I
I
�I
3
t--
I �
i
1
1 ST FL LIFE SAFETY PLAN — SOUTH WING
SCALE: 1 /8" = 1' -0"
riFir 31,. FPVsss11
REVISION BY
I 1/29/04 2 4/19/04
3 6/8/04 REVIEW
4 6/22104 REVIEW BOARD
5 `1/1522/04 REVIEW
(o 1/21/04 REVIEW
8 9/10/04 REVIEW
9 12/1/04 REVIEW
10 7/1/05 CITY OF SOUTH MIAMI REV.
II 10/6/05 CITY OF SOUTH MIAMI REV.
NOTE:
ALL DRAWINGS FOR THIS PROJECT ARE
TO BE READ IN CONJUNCTION WITH
EACH OTHER. THESE INCLUDE, BUT
ARE NOT LIMITED TO: ARCHITECTURAL,
SURVEYING, STRUCTURAL, CIVIL,
MECHANICAL, ELECTRICAL, SPECIALTY
DRAWINGS, do WRITTEN SPECIFICATIONS, .
CONTRACTOR TO VERIFY ALL EXISTING
SITE CONDITIONS AND THOROUGHLY
CHECK ELEVATIONS AND DIMENSIONS
BEFORE COMMENCING WORK.
REPORT TO THE ARCHITECT ENGINEER
ANY DISCREPANCIES, ERRORS OR
CONDITIONS THAT WILL ALTER
CONSTRUCTION AS INTENDED BY
THESE DRAWINGS. ARCHITECT IS
NOT RESPONSIBLE FOR ANY WORK
AND /OR MATERIALS FURNISHED
ON THE JOB.
All graphic material appearing herein,
unless indicated otherwise, are the
property of the Architect as
instruments of service for use solely
on this project, and may not be
duplicated, used or disclosed without
the written consent of Mark E.
Reardon, R.A. The architect retains
all common law, statutory and other
reserved rights.
Wry Q `�y,,}� '• �.
* * rl ;
Ln
V
LL
LL
LL
L
CC
LU
Z
CC
Co
z
N
��.
LA
LL
w
0
Y
zoo
00(.0
y:
3
iY
i b
icy ut 't 6
i:.
15790 SW
88TH AVE
MIAMI, FL
33157
AR 0017521
NOTE:
ALL DRAWINGS FOR THIS PROJECT ARE
TO BE READ IN CONJUNCTION WITH
EACH OTHER. THESE INCLUDE, BUT
ARE NOT LIMITED TO: ARCHITECTURAL,
SURVEYING, STRUCTURAL, CIVIL,
MECHANICAL, ELECTRICAL, SPECIALTY
DRAWINGS, do WRITTEN SPECIFICATIONS, .
CONTRACTOR TO VERIFY ALL EXISTING
SITE CONDITIONS AND THOROUGHLY
CHECK ELEVATIONS AND DIMENSIONS
BEFORE COMMENCING WORK.
REPORT TO THE ARCHITECT ENGINEER
ANY DISCREPANCIES, ERRORS OR
CONDITIONS THAT WILL ALTER
CONSTRUCTION AS INTENDED BY
THESE DRAWINGS. ARCHITECT IS
NOT RESPONSIBLE FOR ANY WORK
AND /OR MATERIALS FURNISHED
ON THE JOB.
All graphic material appearing herein,
unless indicated otherwise, are the
property of the Architect as
instruments of service for use solely
on this project, and may not be
duplicated, used or disclosed without
the written consent of Mark E.
Reardon, R.A. The architect retains
all common law, statutory and other
reserved rights.
Wry Q `�y,,}� '• �.
* * rl ;
NORTH
DRAWN BY:
MER
DATE:
4/17/04
SCALE:
AS NOTED
SHEET NO.:
LS -1
Ln
V
LL
LL
LL
L
CC
LU
Z
CC
Co
z
N
��.
LA
LL
w
0
zoo
00(.0
7-
NORTH
DRAWN BY:
MER
DATE:
4/17/04
SCALE:
AS NOTED
SHEET NO.:
LS -1