07-992-011SPRING k' NEOPRENE TYPE VIBRATION ISOLATORS TYP. 3/8" HANGING RODS STRUCTURAL ) ARCH. ON HOW TO FASTEN TO STRUCTURE -- MOUNTING CLIPS Or' UNITS CONNECTION TO SUPPORT RODS K: RECOMMENDED BY '117G. ELECTRIC HEAT ASSEMBLY FLEXIBLE DUCT CONNECTOR TRANSITION AS REQ'D. RETURN AIR DUCTWORK OUTSIDE AIR DUCT W/ OPPOSED BLADE DAMPER (TYPICAL) -- FILTER & RACK ASSEMBLY 1" GALV. DRAIN PAN STRAPPED TO A.H.U., INSULATED CONDENSATE �J DRAIN AND TRAP' (SEE PLUMB. FOR CONTINUATION) REFRIGERANT LINES TO SUPPLY I CONDENSING UNITS AIR DUCT ti� 2� INSULATE SUCTION LINE) SMOKE DETECTOR ;N SUPPLY AUX. DRAIN (SEE PLUMB. AIR DUCT AS REQUIRED FON CONTINUATION) TRANSITION AS REQUIRED AIR HANDLING UNIT PROVIDE 24" SERV-E CLEARANCE FOR ALL ACCESS FANELS 1A.H.U. HANGING DETAIL N.T.Q. MAINTAIN 1' -0" CLEAR FROM WALL. I 16101 Big &I p, I LC UNIT SPRING VIBRATOR ISOLATORS AT EACH SUPPORT FASTENED C.U. TO SLAB W/ A.B. (ONE AT EACH SUPPORT) AND PROVIDE SOLID ISOLATION PAD FOR CORROTION INIVITER . CONDENSING UNIT BOLTED TO CONCRETE BASE 2 1/2" BOLTS AT EACH SUPPORT :ONCRETE BASE W% LIQUID LINE W/ 0 INSULATION SUCTION LINE UNIT MUST BE INSTALLED TO W/ 1/2 ARMAFLEX WITHSTAND 125 MPH INSULATION HURRICAN FORCE WINDS CONDENSING UNIT AT SECOND FLOOR N.T.S. 25/50 RATED INSUJLATION SUCTION LINE LIQUID L CDNC. STEEL SLEEVE SLAB� ciJ FILL SLEEVE VITA FIRE - PROOF/ FIRE RESISTANT SILICON SEALANT FUAN CTC. PR -055 t0 GAUGE SHEET -HETAL REFRIGERANT LINES (SIZE AS RE010 - / FROM ACCU'S FLASHING AS RE=CUM.� —/✓ BY HANUr. � RIIpF SLAB SEE ENLARQED DETAIL THIS DVG. REFRIGERANT PIPE RA1NCOUER DETAIL N.T.S. � • 1 .�• -,___ --_ter O • RETAIIJING Roll CLIP FLAT OAR ROD E=CL rJ iIL57RUCI'UI31L` EL�dGE` • . W / tEI1IdiTJG CLIP O�IICIC_1I11I E.QLTrREIE_IdSERLi • t11NS�I)�EIlI15ER_4IlI1CRET)< y' A �S1RAP �t FIANGER ��_NANGER WASIIER STRA ROD NUT CCLEW [1+�Ll1�TED.�IlrD�l►�LIL FOR DUCTS UP TO 18' FOR DUCTS UP TO 36' EELSSTRUC7URE,.11t�lE &1G) 14AXIIIUH DIMENSION HAXIMU14 DIMENSION DRIVE PIN THREADED STUD t01_111EB ACT 1llTED_"STENERa ri L J DUCT SUPPORT SYSTEH FOR 11K MANGER 1 t HANGER ALL EXPOSED DUCT STRAP Lffn- . �• !+ UEEL (STRUCTURE OR.DEM $OLT HANGER STRAP FOR Dl1CTS UI Et1lill °�V Trl 1B MAX. f \-STRAP DIMENSION I �_WASIIER EXPANSION SIIIELDS EXPANSION NAIL WASHER 14111 GDNRE_1 L OCICJiC11lS LIOT E, CONSTRUCTIUN AND INSTALLATION SHALL BE AS PFR SMACNA STANDARD FOR TYPE OF DUCTWORK INSTALLED IN FACILITY. UPPER ATTACHMENT METHODS' OF HANGING DUCTS AN EQUIPMENT DETAIL 11. r.5. LOW VELOCITY SUPPLY OR RETURN AIR DUCT 1 � - �SPII4 -IN COLLAR ITFI VOLUME I)AMI�ER OPERATOR TO PE JUTSIDE THE INSULATION. PROVIDE INSULA" :JN GUARD WHERE NECESSARY (DAFtr .'R WHERE NOTED). (PROVIDE DUCT 1- PMPERS WHERE ACCESSIBLE) INSULATED FLEX DUCT SEAL JOINT WITH DUCT :_-ALER INSULATE OR LINE SURi ICES TO PREVE14T CEINDENSAT.UIJ. __�— CEILING DIFFUSER OR RE Y'RN REGISTER. FLEXIBLE DUCT CONNECTION DETAIL N.T.S. J 1/2" HANGER ROD- --•- (4 REQ'D.) FASTENED 10 COIICRETE STRUCTURE ABOVE WITH EXPANSION IOLIS. IIILII KWIK IOLT UIXP. ANCHOR. POO COUPUIIG TYPE 2 1/4" EMDEDMEHr. IPPORT CROSS IDLE (IF REQUIRED) — IIANGFR ROD _—SPRIIIG ISOLAIOR J. OR pIUNE FAN 1W J HANGER .0D A.ILU. JR INLNIE FAN IEYONG UOT10h HUNG 1NLINE I=AN OIL ABC UNIT MG JNT'INc� DETAIL CITY OF SOLIT# I ;. "I BUILDINGA 0[7_!P 'r. ALL DAMPERS SItAU. COMPLY Mill NFRA !OA UL 555 N DUCT ?,'CtiFKr�l:✓aL. "`CTIC};� 2 ACCES. JOOR 2 O INSULA:', iN WHERE DUCTS ED BY: --- - � r- -�3 ARE SU SPECIFIED / I� J J �_ O4 FLOOR -.4 (IF NOT IN �;,�j___ -__ RnoM) — 4 J 11OF U:.L 0. I/C ' A PER f DUCT Ui' ALL FO UR SIDES OCOLLAR LSEE NOTES) O1" TYP..kLL FOUR SIDES O1- 1 /2 %i- 1 /2 "xlO GA. Oh 110ROj;TAI MOUIIj11JG�f HEAVIER ANGLES SNUG TO FLOOR i COLLAR ALL AROUND C! OSER 10 "S" SL.. ` BUGLE AS REQ'D tl WALL BY LOCAL � ILDC• Iz FLOOR S�AI DEPT. i _ � N01E5• — eF I. COLLAR q ,JGES: 1 �t� A, FOR NOT EXCE! DING 36"Y! OR 24 "ll - 16 GAUGE 3 I. FOR COLLARS EXCE::01NG 36"W OR } =- 24 "fl- 14 GAUGE -�� 2. ATTACH AN,;LES TO COLLARS OR (110 10 1EC SCREW:,) Willi 1/4" 20 101 -TS A / NUTS 12" C -C MAX. MIN. 2 BOLTS IN EACII �!Z,E TOP k IOITOM 3. 114SIALLATIOII SIIALL CONFORM Y IjcAL NOUjj1jIIG DEIAIL 10 ItIVA -SOA 4. PROVIDE ACCESS DOORS 10 SERVICE F;,SIILE LINKS AS REQUli:_D HOIE: TYPE "R" I'S OEIAIIfo FOR ALL SUPPLY AIR DLICIS TYPE "A" MAY BE USED FOR ALI. RETURN ARE DUCTS AS REQU4,,I). ALL MOTORIZED EIRE SMOKE DAMPERS SHALL BE TSD -60 TYPE. i TYPICAL STYLE 11131 FIRE DAMPER DETAIL zA All U ARCH.LICENSE AR 07671 ( J 1 , 1 L_l_.1 �1 U O !L '--i E LL_ C3 � _c —I 0 N o c U O N U1 Ld L° �O O W W N E a C U O Q N (0 O t l.n 0 r- V l Ln tn Q a� na U c l 60 d v J � U / ( ) � W O aN o / ( > � Z O < Q�G ARCH. LICENSE AR 07671 job no. 9908 date. 05- -28 -07 scale. As Shown drawn by. A G. reviewed by.' C.M issued. 07 -15 -07 sheet no. M-5