07-790R-019GENERAL NOTES I. EXAMINATION OF CONTRACT DOCUMENTS AND SITE OF WORK THE BIDDER 16 REQUIRED, BEFORE SUBMITTING HIS PROPOSAL, TO VISIT THE SITE OF THE PROPOSED WORK AND FAMILIARIZE HIMSELF WITH THE NATURE AND EXTENT OF THE WORK AND ANY LOCAL CONDITION$ THAT MAY IN ANY MANNER, AFFECT THE WORK TO BE DONE AND EQUIPMENT, MATERIALS AND LABOR REQUIRED THEREFORE, SINCE THE WORK INVOLVES EXISTING BUILDING SYSTEM$ AND FACILITIES, SPECIAL CONSIDERATION $HALL BE GIVEN TO EXAMINATION OF WORKING CONDITIONS. 2. AS -BUILT DW3'6 $HALL BE PREPARED BY THE CONTRACTOR AND MAINTAINED DURING THE COURSE OF CONSTRUCTION, AS -BUILT DRAWINGS MUST BE KEPT CURRENT t0 EACH WEEK'S INSTALLATION AND RECORDED ON A CLEAN FIELD SET MARKED "AS- BUILT" SET. AS -BUILT DRAWINGS $HALL BE PREPARED ON VELLUM PAPER OR OTHER MEDIA WHICH WILL PERMIT REPRODUCTION BY NORMAL PRINTING METHODS. THE DRAWINGS $HALL BECOME THE PROPERTY OF THE OWNER DRAWING $HALL -SHOW THE ACTUAL ROUTING OF ALL WIRING AND CONDUIT SIZE$, USED WITHIN THE SPACE. 3. ELECTRICAL CONTRACTOR $HALL COORDINATE HIS WORK WITH OTHER TRADES AND UTILITY COMPANY(S) At FIELD. ALL WORK $HALL BE DONE IN FULL ACCORDANCE WITH THE NATIONAL ELECTRICAL CODE LATEST EDITION, AND ALL APPLICABLE STATE AND LOCAL CODES. 4. ALL WORK $HALL BE DONE IN A NEAT AND WORKMANLIKE MANNER 5. ALL WIRES $HALL BE COPPER UNLESS SPECIFICALLY OTHERWISE INDICATED ON THE DRAWINGS. ALL INSULATION $HALL BE TYPE "THHN/THWN ". BRANCH WIRING $HALL BE 012 AUG UNLESS OTHERWISE NOTED. LENGTH OF 120VAC HOME RUNS GREATER THAN 15 FEET SHALL BE 010 AWG AND GREATER THAN 100 FEET $HALL BE *s AWG. 6. CONDUIT SYSTEMS $HALL PRESENT A NEAT APPEARANCE, WITH ALL RUNS PARALLEL OR PERPENDICULAR TO THE BUILDING LINES AND TO EACH OTHER ALL CONDUITS $HALL RUN TIGHT AGAINST CEILING SLA56 AND /OR WALL$ AND /OR BEAMS, USE EXISTING HOLES IN BEAMS WHENEVER POSSIBLE. ALL CONDUITS $HALL BE $ECURELY FASTENED TO THE BUILDING WITH PIPE STRAPS OR OTHER APPROVED PIPE SUPPORT$. 1. ALL JUNCTION AND PULL -BOXES $HALL BE ACCESSIBLE ALL THE TIME. 8. ALL RACEWAY ROUTED, INSULATED CONDUCTORS SYSTEM $HALL BE COLOR CODED A$ FOLLOWS` 120/208V SYSTEM - 211/480V SYSTEM - PHASE "A ": BLACK BROWN PHASE "B": RED PURPLE PHASE "C ": BLUE YELLOW NEUTRAL WHITE GRAY WITH WHITE TRACE GROUND GREEN GREEN ISOLATED GROUND: GREEN WAMITE TRACE GREEN W/WHITE TRACE 9. CIRCUIT NUMBERS SHOWN ARE FOR IDENTIFICATION ONLY. It SHALL BE THE ELECTRICAL CONTRACTOR'$ RESPONSIBILITY TO COMPLETE PHASE PANEL BOARD (BALANCE LOAD). lo.- DISCONNECT SWITCHES SHALL BE HORSEPOWER RATED, HEAVY DUTY, QUICK -MAKE, QUICK- BREAK, IN NEMA I OR 3R ENCLOSURE AS REQUIRED BY EXPOSURE. II . ALL OUTLETS MOUNTED ON COMMON WALL BETWEEN ROOM$ SHALL NOT BE MOUNTED BACK TO BACK THEY $HALL BE STAGGERED HORIZONTALLY TO PREVENT SOUND TRANSMISSION. 12. TWO OUTLET BOXES $HALL NOT BE INSTALLED IN THE SAME FRAMING $PACE JOINT COMPOUND OR OTHER APPROVED MATERIAL SHALL BE APPLIED BETWEEN ALL OPEN SPACES, BETWEEN THE JUNCTION BOX AND GYP6UM WALL BOARD, 13, ALL RECEPTACLES $HALL BE WIRED IN ACCORDANCE WITH N.E.C. t0 ENSURE CORRECT POLARITY. 14.- It 16 NOT THE INTENT OF THESE PLANS TO SHOW EVERY MINOR DETAIL OF CONSTRUCTION, THE CONTRACTOR 16 EXPECTED t0 FURNI614 AND INSTALL ALL ITEMS FOR A COMPLETE ELECTRICAL SYSTEM, AND PROVIDE ALL REQUIREMENTS NECESSARY FOR EQUIPMENT TO BE PLACED IN PROPER WORKING ORDER 15.- CONTRACTOR $HALL GUARANTEE ALL MATERIALS, EQUIPMENT AND WORKMANSHIP ARE FREE OF DEFECT FOR A PERIOD OF NO LESS THAN ONE YEAR FROM THE DATE OF ACCEPTANCE. 16. ALL MATERIALS, DEVICES OR APPLIANCES $HALL BE LISTED AND BEAR WITH THE STANDARDS OF UNDERWRITERS LABORATORIES (U.L.) OR ANY APPROVED NATIONALLY RECOGNIZED LABORATORY 11. ALL WORK SHALL COMPLY WITH APPLICABLE SECTIONS OF NEC 511, MEDICAL EQUIPMENT AND ASSOCIATED SYSTEMS SHALL CONFORM t0 UNIT MANUFACTURERS INSTALLATION RECOMMENDATIONS. 16. ELECTRICAL CONTRACTOR $HALL FAMILIARIZE HIMSELF AND COORDINATE WORK WITH EACH MEDICAL UNIT MANUFACTURER SHOP DRAWINGS, FURNISHED WITH EQUIPMENT, AND PROVIDE ANY ADDITIONAL CONDUIT AND /OR WIRING REQUIRED TO ACHIEVE A COMPLETE AND FULL OPERATIONAL INSTALLATION, INCLUDING COMMUNICATION, CONTROL AND DATA WIRING. 19. PROVIDE REDUNDANT GROUNDING SERVICE TO ALL MEDICAL EQUIPMENT SYSTEMS, AS SHOWN AND /OR REQUIRED BY UNIT MANUFACTURER VERIFY WITH EACH UNIT REQUIREMENTS. 20. ALL RACEWAYS, PULL BOXES, J- BOXES, GUTTER$, $URFACE AND RECESSED WIREWAYS SERVING MEDICAL EQUIPMENT $HALL BE METALLIC TYPE, AND ELECTRICALLY AND MECHANICALLY BONDED PER NEC ART 250 AND 300, 21. FROM THE BEGINNING OF THE JOB AND /OR AS PERMITTED BY THE CIRCUMSTANCES, ALL ELECTRICAL EQUIPMENT, ELECTRICAL RM'S, ELECTRICAL CLOSETS AND MEDICAL EQUIPMENT AREAS ETC., $HALL BE PREPARED t0 BE DUST FREE LOCATIONS, BEFORE STARTING INSTALLATION OF ANY ELECTRICAL DUST SENSIBLE EQUIPMENT (IE: MRI, CT X -RAY EQUIPMENT DEVICES, MEDICAL UNITS, MEDICAL COMPUTERS, ETC.) 22. ALL WIRING SERVING MEDICAL EQUIPMENT $HALL BE THUi THHN, COPPER RATED 600V AND UL LABELED. 23. EQUIPMENT POINT OF CONNECTION. ELECTRICAL CONTRACTOR $HALL LEAVE 5 Ft (OR (OFT WHEN NECESSARY) PIGTAILS AT JUNCTION POINTS WITH MEDICAL EQUIPMENT CONTRACTOR6 WHEN APPLICABLE. FEED WITH : 4% THHN /THWN CU + 1010(G) IN I "C, (3), "A Is 3 FEED WITH : 401 /OTPW CU + 106(G) IN 2 "C. TYPE: SQUARE -D NQOD MODIFICATION: GROUND BUS BAR VOLTAGE: 120/208V, 3PH, 4U1 P A N E L" A ENCLOSURE: NEMA 1, RECESSED MAINS: 225 A M.L.O. LOCATION: CORRIDOR. AREA A.I.C.S.: lo,000 FED FROM: PANEL "DPA" 3P/150A DESCRIPTION WIRE AND COND.SIZE LOAD (VA) POLE TRIP CT No A B C CT No. POLE TRIP LOAD (VA) WIRE AND COND.SIZE DESCRIPTION EXIT SIGN 4 EMERG LTS. 010,11/2" 1200 1/20 1 2 2 60 4364 4364 206, 3/4" 1*10(G) ANU -1 - 4112,11/2" 500 1/20 LIGHTING 012,1/2" 1350 1/20 3 4 - 900 *12, 1/2" RECEPTACLES LIGHTING= *12, 1/2" 1400 1/205 RECEPTACLES 6 V40 -- 206,3/4"1 1010(G) CU-1 1/20 120 012, 1/2" RECEPTACLES LIGHTING 012,11/2" 1300 1/20 7 8 -- - 7 8 1/20 LIGHTING 012,1/2" 1040 1/20 9 RECEPTACLES 2 60 4364 4364 206, 3/4" AHU -2 10 1/20 LIGHTING 012,1/2" 350 1/20 11 [12 012, 1/2" RECEPTACLES LIGHTING *12, 1/2" 1250 1/20 13 4`12,11/2" X40 -- 2118, 3/4" 1 *10(G) CU-2 -- RECEPTACLES LIGHTING *12, 1/2" 1120 1/20 15 18 .. 012, 1/2" APPL. RECEPT. LIGHTING 012,1/2" 985 1/20 17 18 X30 1380 3 *10, 1/2" 1*I0(G) AIR COMPRESSOR (2NP) - 1100 *12, 1/2" REFRIGERATOR LIGHTING 012,11/2" 520 1/20 19 20 1380 1/20 17 LIGHTING *12, 1/2" 1300 1/20 21 22 2 15 -- 2012 1/2" 1012(G) AHU -3 012,1/2" 500 1/20 19 EU)H 3010,1/21- 1010(G) 2250 2250 X30 23 24 -. - - SPARE SERVER RACK 01 2 012 1/2" 1*12(G) 25 26 2 40 2412 206,3/4" 1010(G) CU -3 012, 1/2" TEL SYS. SCRIP HTR CAC -3) 2012,1/2' 1012(G) 1250 2 15 27 28 2412 300 012, 1/2" SEC SYSTEM 1250 29 30 1/20 15001 -- SPARE - 25 28 1 PHASE A: 14,616 VA. PHASE B: 11,200 VA. PHASE C: 13,013 VA. TOTAL: 44,955 VA 124.9 AMPS. DEMAND FACTOR PER NEC 210.19, 215.3.44033 LIGHTING LOAD: 12,415 VA X 125% = 15,519 MECH EQUIP /NON CONT. 30,944 VA X 100% = 35,168 LARGEST MOTOR LOAD a 25% 1,911 TOTAL LOAD = 53,204 LOAD = 53,204 / 208(3) $OR 141.8 AMPS I. PROVIDE CIRCUIT BREAKER HACR TYPE. 2. NON CONCURRENT LOAD, HEATING CYCLE LOAD LARGER THAN COOLING. 3. LABEL "ON ALL TIMES" THIS BREAKER, SERVING EM BATTERY BACKUP CHARGERS. 4. LEAVE 2- 3 /4 "EC (EMPTY CONDUITS) $TUB -UP t0 CEILING SPACE FOR FUTURE, 5, NON CONCURRENT LOAD, COOLING CYCLE LOAD LARGER THAN HEATING, FEED WITH : 4*3THU) CU + 106(G) IN 1 1 /2 "C. TYPE: SQUARE -D NQOD MODIFICATION: GROUND BUS BAR VOLTAGE: 120/208V, 3PH, 4W PANEL "B" ENCLOSURE: NEMA 1, RECESSED MAINS: 100 A M.L.O. LOCATION: CORRIDOR. AREA A.I.C.S.: 10,000 FED FROM: PANEL "DPA" 3P /IOOA DESCRIPTION WIRE AND COND.SIZE LOAD (VA) POLE TRIP CT No A B C CT No. POLE TRIP LOAD (VA) WIRE AND COND.SIZE DESCRIPTION RECEPTACLES 012,11/2" 120 1/20 1 2 1/20 120 012,1/211 SKY/MAGIC REC - 4112,11/2" 500 1/20 RECEPTACLES 012,1/2" 300 1/203 012,11/2" 4 1/20 900 *12, 1/2" RECEPTACLES 5 6 X20 1653 RECEPTACLES '112,1/2" 120 1/20 5 6 1/20 120 012, 1/2" RECEPTACLES - 012, 1/2" SPACE - - RECEPTACLE$ 012,11/2" 120 1/20 7 8 1/20 120 012, 1/2" RECEPTACLES SPACE -- RECEPTACLES 012,11/2" 120 1/20 9 10 1/20 120 012, 1/2" RECEPTACLES 6 CONVENIENCE REC 012, 1/2" RECEPTACLES 1012,1/2" 120 1/20111 1/20 1211/20 4`12,11/2" 1 800 012, 1/2" D.P. -- -- RECEPTACLES 012, 1/2" 120 1/20 13 14 1/20 1500 012, 1/2" APPL. RECEPT. - 9 RECEPT, WAITING 012, 1/2" 120 1/20 15 18 1/20 1100 *12, 1/2" REFRIGERATOR 012,11/2" 300 1/20 17 RECEPT. TV 012, 1/2" 540 1/20 17 18 1/20 120 *12, 1/2" RECEPT, RECEPTION 19 20 1/20.500 105.8 MECH REC 012,1/2" 500 1/20 19 20 1/20 1100 *12, 1/2" COPIER - 500 - - SPARE SERVER RACK 01 2 012 1/2" 1*12(G) 1500 X20 21 22 1/20 800 012, 1/2" TEL SYS. - - - SPACE 1500 23 2411/20 300 012, 1/2" SEC SYSTEM 1 25 28 1 SERVER RACK *2 3012,1/2" 1500.1/20 25 28 1 -- -- SPACE - 27 28 1 IAMG- RECEPT 012, 1/2" 500 1/20 27 28 1 - - - - SPACE - 29 30 1 SPARE - - 50011/20 29 30 1 - - - - SPACE PHASE A: 8,200 VA. PHASE B: 1,860 VA. PHASE C: 1,120 VA. TOTAL: 23,180 VA 64.4 AMPS. DEMAND LOAD CALCULATION PER N,E.C. 220.13 4 220.10(5) TOTAL CONNECTED RECEPTACLE LOAD = 22,160VA RECEPTACLES IsT.10,000 VA is 10090 = 10,000 REMAINING RECEPT LOAD (VA) a 509, = 6,090 TOTAL LOAD = 16,090 LOAD = I6,090 / 208(3) $QR = 44.1 AMPS 1. LEAVE 2- 3 /41C (EMPTY CONDUITS) 6TUB -UP TO C51LING SPACE FOR FUTURE, FEED WITH : 403THU) CU + 108CG) IN 11/2 "C. ME TYPE: SQUARE -D NQOD MODIFICATION: GROUND BUS BAR VOLTAGE: 120/206V, 3PH, 4U) PANEL" C v) A ENCLOSURE: NEMA 3R, SURFACE MAINS: 100 A M.L.O. LOCATION: 2ND FL, MECH AREA A.I.C.S.: 10,000 FED FROM: PANEL "C" 3P /60A DESCRIPTION WIRE AND COND.$IZE LOAD (VA) POLE TRIP CT No A B C CT No. POLE TRIP LOAD (VA) WIRE AND COND.SIZE DESCRIPTION AG UNIT 01 2 *121/2" 1012(0) 815 2 15 1 2 M20 1121 2 01 I/2" 1012(G) AC UNIT 06 UVR SYSTEM 4112,11/2" 500 1/20 815 3 4 1121 012,11/2" OP VARIS /PV REC AC UNIT 08 2012 1/2" 1012(G) 965 2 20 5 6 X20 1653 20'12 1/2" 1012(G) AC UNIT *5 - 900 1012,1/2" OP MLC REC 365 1 8 1653 CONTROL CONSOLE REC 012, 1/2" SPACE - - - - I 9 t0 2 20 1653 " 1012(G) AC UNIT 04 150 SPACE -- -- I 11 12 1653 PHASE A: 4,560 VA. PHASE B: 3,595 VA. PHASE C: 4,211 VA. TOTAL: 12,426 VA 34.5 AMPS. DEMAND FACTOR PER NEC 21019, 2153. MED. AC LOADS (VA) 19 100% = 12,426 TOTAL LOAD = 12,426 WITH DOOR FLUSH LOCK AND KEY. LOAD = 21,186 / 208(3) $OR s 34.5 AMPS (1) (2) (1) (2) ll) (5) -- EXISTING BUILDING --t1!XWNG; �- METER ROOM I GGARAGE- I V-11OFT I I I I I I I I ►, I I I ( I I I �q; I I c1 q I ( I ANEL " P j CC'S I I 12ono8 q Q i J- BOX ( I 3PH, 4W z C Iz�l I 1X01 I I I ;WN; I I I I II ELECTRICAL I ,I IL NAC I CT ROOM I CORRIDOR 02 - --� VAULT - - ! - - - - - - - I I I-- -- -- -- -- I I I I I I I I I I I I I I I 8 I I t 4 2 I I I I I I I I ( I A > a EL ' " EL I I (ME ) o I , g, I Y oT E $) I I I o! E- I I I I I I I °; I Lu Qtr e Q (L I I CA w'- I o I l 8 l ell 3 208�v 5 I I I I I } 15KVA 14 ' ( , 4 "I y ' eq y 9 I " I I I I - 0'2(G) PB PB _ I ELECTRICAL_ R15ER DIAGRAM N.T.5, D D D RISER QUIRE AND EQUIPMENT SCPMULE CI 303/0 THW CU + 1111 (G) IN 2 "C (DELI PRIM) O 4% THW COPPER + 102(G) IN 1 -1 /4 "C O 401/0 THW COPPER + 1% (G) IN VC O403 THW COPPER + 106 (G) IN 1 -1/2 "C O 15 KVA DRY TYPE STEP -UP TRANSFORMER, 208V DELTA PRIMARY, 460/211V WYE $ECUNDARY, NEMA I ENCLOSURE, MANUR BY $QUARE -D CLASS 1414 CAT* 15T(103)HE)IT O 2 SETS OF (4%OOMCM THHN/THWN + IM(G) ) IN 2- 3 -1 /2 "C O Ct'S RATED SODA -208Y, 3PH WITH NEMA I CABINET, 36 "X36 "X14' MANUFACTURED BY HOFFMAN PROVIDE ALL REQUIRED HW MOUNTING AND CT METER/CAN. O 403 THHN/THWN COPPER + 1*3 (G) + 1*30G) IN 1 -1 /4 "C C9 403 THHN/THWN COPPER + 11130G) IN 1 -1 /4 "C 10 4% THHN/THWN COPPER + 110(G) IN I "C TYPE: SQUARE -D NQOD MODIFICATION: GROUND BU$ BAR VOLTAGE: 120/208V, 3PH, 4U) P A N E L" C ENCLOSURE: NEMA 1, RECESSED MAINS: 225 A M.L.O. LOCATION: CORRIDOR. AREA A.I.C.S.: 10,000 FED FROM: PANEL "DPA" 310/100A DESCRIPTION WIRE AND COND.SIZE LOAD (VA) POLE TRIP CT No A e C - CT No. POLE TRIP LOAD (VA) WE AND COND.SIZE DESCRIPTION SET- LT/MON /CAM /LASER 012, 1/2" 1300 1/20 1 2 1/201200 3RD FLOOR TENANT$ 012, I/2" DOOR INTERLOCK UVR SYSTEM 4112,11/2" 500 1/20 31 4 1/20 300 012,11/2" OP VARIS /PV REC I CLINAC TRASTECTOR Total est Load (Kva) v MOTORIZED DOOR *12, 1/2" 500 1/20 5 6 1/20 900 1012,1/2" OP MLC REC 11,100 11,100 11,100 ADJ -MAG TRIP CONTROL CONSOLE REC 012, 1/2" 1080 1/20 7 81/20 5,400 1000 1012,1/2" CONTROL PANEL "A" 3 150 CONVENIENCE REC 012, 1/2" 900 1/20 9 10 1/20 140 '42,11/2" EP -5 1,860 1,120 6 CONVENIENCE REC 012, 1/2" 900 1/20 11 12 1/20 80 4`12,11/2" EF -6 - -- -- CONTROL CONSOLE REC 012, 1/2" 900 1/20 13 14 3 60 4560 406 1010(G) IN I "C SUB -PANEL "Cl" - 9 CONVENIENCE REC 012, 1/2" 300 1/20 15 16 3535 10 CONVENIENCE REC 012,11/2" 300 1/20 17 18 4211 TOTAL VA: 84,636 CONTROL CONSOLE REC *12, 1/2" 300 1/20 19 20 1/20.500 105.8 - - SPARE PANEL "DPA" CALCULATION SPACE - - - - I 21 22 1/20 500 - - SPARE MEDICAL EQUIPMENT ------ - - - - -- 150,940 VA REMAINING 12,160 VA 0 50% ---------------- - - - - -- 6,090 SPACE - - - - 1 23 24 1 - - SPACE - TOTAL: ....... 249,929 VA SPACE - - - - 1 25 28 1 - - - - SPACE SPACE - - - - 1 27 28 1 - - - - SPACE SPACE . - - - I 29 30 1 - - - - SPACE PHASE A:10,440 VA. PHASE B: 1,435 VA. PHASE C: 1,551 VA. TOTAL: 25,426 VA 10.6 AMPS. DEMAND FACTOR PER NEC 210.19, 2153. MEDICAL LOA06 (VA) s M% s 13,000 MED. AC LOADS (YA) a 1009'0 = 12,426 TOTAL LOAD = 25,426 LOAD = 25,426 / 20V3) $QR as 10.6 AMPS I. LEAVE 3- 3 /4 "EC (EMPTY CONDUITS) STUB -UP TO CEILING SPACE FOR FUTURE. D O FEED WITH : 2 SET$ OF (40600MCM THHN /THWN + 101(G) ) IN 2- 3 -1 /2 "C LOAD SUMMARY MODIFICATION: GROUND BU$ SERVICE 3000A, 120/206V, 3PH, 4W PANEL" D P A ENCLOSURE: NEMA 1, SURFACE EXISTING BUILDING MAIN DISTRIBUTION PANEL "PDA" SIEMENS "$132" TYPE A.I.C.S.: 22,000 o LOAD DESCRIPTION BRANCH EST. LOAD CIRCUIT CKT (KVA) 161 FLOOR TENANT$ 3P /800A 220.0 3RD FLOOR TENANT$ 3P /600A 205.0 4tH FLOOR TENANTS 3P /600A 160.0 5tH FLOOR TENANT$ 3P /800A 186.0 1ST FLOOR PROPOSED 3P /600A 2411 (1) TENANT I CLINAC TRASTECTOR Total est Load (Kva) v 10381 Total est Load (amp) 28,280 2,885.3 EXISTING 3000 A SERVICE WITH 6 SET$ OF (4"500 MGM IN 4 "C) t0 REMAIN 3 (1) CIRCUIT UNDER THIS CONTRACT, PROVIDE NEW CIRCUIT BREAKER IN EXISTING SPACE TO MATCH MANUFACTURER AND MODEL TYPE. TYPE: SQUARE -D I -LINE MODIFICATION: GROUND BU$ VOLTAGE: 12O/2O6V, 3PH, 4U) PANEL" D P A ENCLOSURE: NEMA 1, SURFACE MAINS: SODA M.L.O. LOCATION: COMM /COMPUTER$ RM A.I.C.S.: 22,000 o FED FROM:3P /800A MAIN/METER RM 10 CT SERVING CIRCUIT BREAKER LOAD IN VA REMARKS C 11�J� (L v No POLE Cr TRIP OA OB 0C I CLINAC TRASTECTOR 3 v 300 28,280 28,280 28,280 ADJ -MAG TRIP 2 CT- STEP -UP XFMR/PNL MP 3 200 11,100 11,100 11,100 ADJ -MAG TRIP 3 CLINAC CHILLER UNIT 3 10 5,400 5,400 5,400 ADJ -MAG TRIP (1) 4 PANEL "A" 3 150 14,616 11,200 13,019 as 5 PANEL "B" 3 100 6,200 1,860 1,120 6 PANEL "C" 3 C3 100 10,440 1,435 1,551 1 SPACE 3 -- -- -- -- 8 SPACE 3 -- -- -- -- 9 10 TOTAL VA: 84,636 63,615 19,130 TOTAL AMPS: 105.8 638.3 659.4 PANEL "DPA" CALCULATION DEMAND LOAD CALCULATION PER N.E.G. 220.13 4 220.10(5) CONNECTED LOAD MEDICAL EQUIPMENT a 10090 150,940 VA LIGHTING LOAD ----------------- 12,415 VA RECEPTACLES IsT. 10,000 VA a 1009............ 10,000 MEDICAL EQUIPMENT ------ - - - - -- 150,940 VA REMAINING 12,160 VA 0 50% ---------------- - - - - -- 6,090 RECEPTACLES ------------- - - - - -- 22,ISO VA LIGHTING LOAD 12,415 VA ,@ 125% ---------- - - - - -- 15,519 MECHANICAL EQUIPMENT -- - - - - -- 64,394 VA MECHANICAL EQUIPMENTS 100% --------- - - - - -- 64,394 .......... LARGEST MOTOR 6 25410 ------------------ - - - - -- 1,911 TOTAL: ....... 249,929 VA TOTAL: ....... 241,101 VA LOAD = 249,929 VA / 360 = 694.2 AMP$ 3 I LOAD = 241,101 VA / 360 = 688.1 AMPS 1. RUN 304 THW CU 4 1$$ (G) IN I 1 /4 "C CITY OF SCUrN MIAMI E3UILDING UEP r ELEG- i RICA SECTION 3 1PPIROVED BY: __ --- ATE ElMAIL lk H � U L o s A C 11�J� (L v M M e} Cr u rn v v vQi ° 2 W v= .' a 0 c 3 �d v: w L5 ul as S V fl i G3 Z � C3 H U H s u M M e} u O N N 00 W 0 u- E­q U �H Z W R o W �w= I_. O G4 5 a W r) U L= - wok _. IJ_ M Z uJ -02 Q ti� W U) u) 00 n O CL 0014 � 3 DATE, 03114107 PRoJ NO: - pDura BY, JEB FMVI 04/06/07 11/16/2007 FIELD-CHG. A 302/04/2008 CT-CHG. OF &