Loading...
07-790R-013(A PARTIAL FLOOR FLAN - POWER SCALE: 1/4" = V -011 i I PARKING DRAWING LEGEND (POWER & SIGNAL) SYMBOL PE5CRIP'ION U DUPLEX GROUNDED RECEPTACLE RATED 20A, 125V, MOUNTED 16 INCHES AFF. i TYPICAL, AS DIRECTED BY ARCHITECT EXCEPT OTHERWISE INDICATED. DUPLEX GROUNDED RECEPTACLE RATED 20A, 125V, CENTER PILL DENOTES I OUTLET MOUNTED 48 INCHES AFF. OR ABOVE COUNTER (COUNTER HEIGHT) AS GFI DIRECTED BY ARCHITECT EXCEPT OTHERWISE INDICATED. 'l DENOTES DUPLEX RECEPTACLE WITH GROUND FAULT INTERRUPTER DEVICE TYPE. (A PARTIAL FLOOR FLAN - POWER SCALE: 1/4" = V -011 i I PARKING DRAWING LEGEND (POWER & SIGNAL) SYMBOL PE5CRIP'ION U DUPLEX GROUNDED RECEPTACLE RATED 20A, 125V, MOUNTED 16 INCHES AFF. TYPICAL, AS DIRECTED BY ARCHITECT EXCEPT OTHERWISE INDICATED. DUPLEX GROUNDED RECEPTACLE RATED 20A, 125V, CENTER PILL DENOTES E-� OUTLET MOUNTED 48 INCHES AFF. OR ABOVE COUNTER (COUNTER HEIGHT) AS GFI DIRECTED BY ARCHITECT EXCEPT OTHERWISE INDICATED. 'l DENOTES DUPLEX RECEPTACLE WITH GROUND FAULT INTERRUPTER DEVICE TYPE. m SINGLE GROUNDED RECEPTACLE: 125V., 20A, + 16 INCHES. NEMA 5 -20R, EXCEPT OTHERWISE INDICATED. COMBO TELEPHONE/DATA OUTLET MULTIPLE CONFIGURATION, FLUSH WALL T MOUNTED IN A 4" SQUARE BY 11/2" DEEP BOX WITH PLASTER RING. UP IS" AFF., d OR COUNTER HEIGHT, EXCEPT OTHERWISE INDICATED. DUPLEX TELEPHONE OUTLET, FLUSH WALL MOUNTED IN A 4" SQUARE T BY 11/2" DEEP BOX WITH PLASTER RING. UP 18" AFF., EXCEPT w OTHERWISE INDICATED. T SINGLE TELEPHONE OUTLET - FLUSH WALL MOUNTED IN A 4" SQUARE BY 1.1/2" "W" P W DEEP BOX WITH PLASTER RING UP, DENOTES WALL MOUNTED 52" AP:, w c 0 "P11 DENOTES FOR PUBLIC USE EXCEPT OTHERWISE INDICATED. �j "TV" (AUDIO/VISUAL) OUTLET, FLUSH WALL MOUNTED IN A 4" SQUARE BY 2 3/4" ry DEEP BOX WITH PLASTER RING. PLATE AND JACK BY "TV" (AUDIOMSUAL) o CONTRACTOR SYSTEM CABLE IN I" CONDUIT, RUNNING IN CEILING SPACE FIRE ALARM HORN/STROBE LIGHT. PROVIDE A 4" $MARE BY 2 1 /8" DEEP WITH PLASTER RING WITH �5C0 CANDELA (15CD) AS $HM ON PLAN. MOUNT 60" APA TO BOTTOM. MANUFACTURER TO MATCH EXISTING. F[]Q REFER TO BASE BUILDING UNIT MANUFACTURER SHOP DRAWINGS $PEA .ER/STROBE - SYNCHRONIC. 15CO DENOTE$ UNIT CANDELA LIGHT LEVEL FIRE ALARM PULL STATION. PROVIDE A 4" $QUARE BY 2 1 /$" DEEP WITH PLASTER RING C] MOUNT 42 AF):. TO BOTTOM. MANUFACTURER TO MATCH EXISTING. REFER TO BASE BUILDING UNIT MANUFACTURER $HOP DRAWINGS ,HD DENOTES AREA FURNISHED WITH OUTLET($) (DEVICE AND COVER PLATE) HOSPITAL GRADE TYPE AS SHOWN •D DENOTES DEDICATED EQUIPMENT OUTLET OF DENOTES DRINKING FOUNTAIN 0 PROXIMITY /SECURITY BADGE. 2 al-I DENOTES DRINKING FOUNTAIN 2 POWER &SIGNAL NOTES "B" I. FOR R165R DIAGRAM AND GENERAL NOTES REFER TO SHEET E -5 2. FOR WIRING SIZES SEE PANEL SCHEDULE SHEET E -5 �I 3. FOR ELECTRICAL ENLARGED ROOM LAYOUT SEE SHEET E -4--' 4. NO RECEPTACLES SHALL BE LOCATED ABOVE SINK. RECEPTACLES SHALL BE LOCATED 6 INCHES MINIMUM FROM SINK EDGE WHEN APPLICABLE AND SHALL BE G.F.I. TYPE. 5. FOR DATA/TELEPHONE, WIRED WITH APPROVED CAT6 CLASS E PLENUM RATED CABLE, PROVIDE A MULTIPLE CONFIGURATION COMBO DATA/VOICE- TELEPHONE OUTLET (TYPICAL). EXTEND WITH A 2 3 /4 "EC TO CEILING SPACE (NETWORK, DIGITAL DATA AND TELEPHONE SIGNAL) DATA /TELEPHONE CABLE AND OUTLETS SHALL BE INSTALLED TO COMPLY WITH EIA/TIA WIRING METHODS AND STANDARDS AND STRICTLY.COORDINATED WITH VOICE -DATA CONTRACTOR AND MEDICAL EQUIPMENT MANUFACTURER REPRESENTATIVE. 6. PROVIDE A DEDICATED GROUNDED RECEPTACLE AND PHONE LINE FOR SECURITY ALARM EQUIP. 1. tHERMOSTAT WIRING $HALL BE DONE BY ELECTRICAL CONTRACTOR, AS PER UNIT MANUP. CONTROL DI . 6. PROVIDE AIR HANDLER UNIT DISCONNECT SWITCH TO COMPLY WITH N.E.C. 440 VERIFY EXACT WIRING REQUIREMENTS AND PROTECTION SIZE WITH UNIT MANUFACTURER NAMEPLATE RECOMMENDATIONS, 9. EXISTING TELEPHONE SERVICE PROVISIONS I "C FROM BUILDING MAIN TELEPHONE BOARD LOCATED AT EXISTING BUILDING METER ROOM. EXTEND EXISTING CONDUIT (TO MATCH EXISTING) TO TENANT TELEPHONE BOARD/TELEPHONE SYSTEM, TERMINATE AS REQUIRED BY EQUIPMENT FURNISHED. VERIFY EXACT LOC AND MTG HEIGHTS AT FIELD WITH OWNER REP AND IT CONSULTANT BEFORE ROUGHING -IN. SEE PARTIAL SITE PLAN DWG E -4. 10 ALL FIRE ALARM DEVICES $WOLIN FOR REFERENCE ONLY. EXISTING FACILITY FIRE ALARM UNIT MANUFACTURER IN$TALLER/CONTRACTOR $HALL PROVIDE SHOP DRAWINGS FOR THE TENANT ADDITIONAL AND RELOCATED DEVICES, II, ALL FIRE ALARM DEVICES INSTALLED, SHALL BE UL LISTED, UL, AND SAME MANUFACTURER COMPATIBLE WITH EXISTING SYSTEM AND APPROVED FOR THE PURPOSE WHICH THEY ARE INTENDED. FINAL CONNECTION BETWEEN NEW COMPONENTS AND EXISTING EQUIPMENT $HALL BE MADE UNDER DIRECT SUPERVISION OF A QUALIFIED TECHNICAL REPRESENTATIVE OF THE EQUIPMENT MANUFACTURER, WHO $HALL TEST THE SYSTEM COMPLETELY, COORDINATE AT FIELD ALL REQUIRED INSPECTION$ AND PROVIDE AN "AS BUILT" SHOP DRAWING AND CERTIFICATE IN WRITHING AS TO PROPER INSTALLATION AND OPERATION OF THE FIRE ALARM PRIOR TO THE FINAL ACCEPTANCE OF THE SYSTEM BY THE OWNER 12. PROVIDE AIR HANDLER UNIT DISCONNECT SWITCH TO COMPLY WITH N.E.C. 440 VERIFY EXACT WIRING REQUIREMENTS AND PROTECTION SIZE WITH UNIT MANUFACTURER NAMEPLATE RECOMMENDATIONS. INDOOR BLOWER UNIT WIRED FROM OUTDOOR CONDENSER UNIT TERMINAL BLOCK, CKT PROT, FROM OUTDOOR UNIT, REFER TO UNIT MANUFACTURER INSTALLATION REQUIREMENTS, 13. AC -3 VENTILATION SYSTEM ON -OFF SWITCH, SHALL BE WIRED THROUGH THE VARIAN VAULT DOOR OPERATOR REFER TO UNIT MANUFACTURER WIRING REQUIREMENTS. EF -5 $HALL BE INTERLOCK WITH AC -3 PER MECHANICAL a SEQUENCE OF OPERATION, REFER TO MECHANICAL DRAWINGS. 0CEP, . Am 0 p � Xrn C o ° v = Ip w ^ u O t2 o E lu 3 V) W rn N �3 t5 5 � a E-+ U 0 E-� s uV Z W 2 N o W d 1 .r Q_ w U O N N u w c 0 �j ° �� a o Q 0 W O jig j1plax.-wil 6 j fiN IS2 51 533WR89" DATES 03114107 PROJ No$ - 0114 BYE JEB REv, - 04/08/07 11/18/2007 FIELD -CHG. A 212/10/2007 IT- REVISION 02/04/2008 3 CT -CHG. E -2 0 F 0 (n Z W 2 N o W w 0 5 Q_ w U W °� �j � =M zUaQ Q 04� Z 00 0 CL jig j1plax.-wil 6 j fiN IS2 51 533WR89" DATES 03114107 PROJ No$ - 0114 BYE JEB REv, - 04/08/07 11/18/2007 FIELD -CHG. A 212/10/2007 IT- REVISION 02/04/2008 3 CT -CHG. E -2 0 F