07-790R-010DRAWING LEGEND (LIGHTING)
SYMBOL
DESCRIPTION
U
LIGHT FIXTURE RECESSED TYPE, 2'x4' FLUORESCENT TROFFER, HALF FILLED
FIXTURE DENOTES UNIT FURNISHED WITH EMERGENCY BUILT -IN BATTERY BACKUP
TO OPERATE AT LEAST TWO (2) LAMPS FOR A MINIMUM OF 1.5 HRS.
LIGHT FIXTURE RECESSED TYPE, 2'x2' FLUORESCENT TROFFER, HALF FILLED
F1 ®
FIXTURE DENOTES UNIT FURNISHED WITH EMERGENCY BUILT -IN BATTERY BACKUP
TO OPERATE AT LEAST TWO (2) LAMPS FOR A MINIMUM OF 1.5 HRS.
0T
UNIVERSAL MOUNTED ILLUMINATED EXIT SIGN WITH BUILT -IN EMERGENCY BATTERY
TO OPERATE FOR 1.5 HOURS MINIMUM.
DOUBLE HEAD EMERGENCY LIGHT WITH BUILT -IN EMERGENCY SEALED MAINTENANCE
FREE BATTERY PACK TO OPERATE FOR 1.5 HOURS MINIMUM.
0 0
DOWN LIGHT FIXTURE RECESSED, REFER TO LIGHT FIXTURE SCHED FOR VOLT AND TYPE
la
SINGLE POLE TOGGLE 120V, 20A SWITCH, WIRED ON SWITCH LABEL 'a' MTG + 48 INCHES.
t3 14
3 -WAY OR 4 WAY TOGGLE 120V, 20A SWITCH MTG + 48 INCHES.
D
DIMMER SWITCH LUTRON NOVA SERIES 120V, 150OW OR EQUIVALENT,
�
MOUNTED AT 48" A.F.F.
O
DENOTES REFER TO LIGHT FIXTURE SCHEDULE, FIXTURE TYPE W
NL
DENOTES LIGHTING FIXTURE CONNECTED AHEAD OF LIGHT SWITCH
"ON" ALL TIMES. (DYMO LABEL FIXTURE OUTSIDE AS NIGHT LIGHT)
O
CEILING MOUNTED SPEAKER.
HOME RUN TO PANEL: 'A' = PANEL DESIGNATION. '1.3.5.' = CKT.
�
NOS. TICKS = NO. OF #12 WIRES IN 1/2 INCH CONDUIT UNLESS
A-1,3,5-,-)
OTHERWISE NOTED. EQUIPMENT GROUND CONDUCTOR WHERE SHOWN.
NOTE: FOR LIGHT FIXTURE NUMBER OF LAMPS, TYPE AND VOLTAGE SEE LIGHT FIXTURE SCHEDULE DWG E -4 TYPICAL.
LIGHTING FIXTURE NOTES "A"
1. LENS FOR FLUORESCENT LIGHTING FIXTURES SHALL BE EXTRUDED 100% VIRGIN
ACRYLIC AND 0.125 INCHES MINIMUM THICKNESS.
2. PROVIDE ALL FLUORESCENT LIGHTING FIXTURES WITH HIGH POWER FACTOR BALLAST.
3. CONTRACTOR SHALL WIRE EMERGENCY LIGHT & EXIT FIXTURE BATTERY CHARGERS
TO A DEDICATED EXIT - EMERGENCY CIRCUIT AS SHOWN, ON ALL TIMES AND AHEAD
OF ANY LOCAL SWITCH, TO MAINTAIN EMERGENCY BATTERY BACK -UP CHARGED.
4. ALL EXIT LIGHTS SHALL HAVE DOWN LIGHT AND 6 INCH RED BACKGROUND LETTERS.
ALUMINUM FINISH HOUSING, EXTENDED LIFE LAMPS, AND SHALL HAVE DIRECTIONAL
ARROWS WHERE SHOWN OR REQUIRED. FIXTURES SHALL BE DOUBLE FACED WHERE
SHOWN OR REQUIRED. WHERE CEILING IS NOT MORE THAN 9 FT. 0 IN. HIGH,
FIXTURES MAY BE EITHER WALL OR CEILING MOUNTED. PROVIDE OUTLET AS
REQUIRED.
5. CEILING LAYOUTS INDICATED ON THE PLANS ARE FOR CONVENIENCE ONLY.
THE ELECTRICAL CONTRACTOR SHALL COORDINATE THE LIGHTING FIXTURES LAYOUT
WITH THE GENERAL CONTRACTOR, THE CEILING SYSTEM CONTRACTOR AND THE
MECHANICAL CONTRACTOR BEFORE THE CEILING, AIR OUTLETS, OR LIGHTS ARE
INSTALLED.
6. ELECTRICAL CONTRACTOR SHALL VERIFY CEILING CONSTRUCTION AND PROVIDE
ALL ADEQUATE LIGHTING SUPPORTS, TRIMS, ETC. BEFORE ORDERING ANY LIGHTING
FIXTURES.
7 FOUR HANGER WIRES SHALL BE USED FOR SUPPORTING LAY --IN FLUORESCENT
LIGHTING FIXTURES INDEPENDENTLY OF THE SUSPENDED CEILING SYSTEM.
LIGHTING FIXTURES SHALL BE PROPERLY SECURED BY ONE SECURING CLIP AT
EACH CORNER.
8. ALL LIGHTING FIXTURES COLOR FINISH SHALL BE SELECTED AND APPROVED BY
ARCHITECT BEFORE ORDERING.
9. ALL BALLASTS SHALL BE HIGH FREQUENCY ELECTRONIC TYPE AND INSTANT -START
WITH A MAXIMUM "THD" OF 10 %, BALLAST FACTOR SHALL BE NOT LESS THAN
90% AND BALLAST EFFICACY FACTOR SHALL NOT BE LESS THAN 1.07o.
10. BALLAST SHALL MEET THE REQUIREMENTS OF FEDERAL COMMUNICATIONS
COMMISSION (FCC) AND NEMA LIMITS GOVERNING EMI AND RFI AND SHALL NOT
INTERFERE WITH OPERATION OF OTHER NORMAL ELECTRICAL EQUIPMENT.
11. BALLAST SHALL OPERATE AT SOUND LEVEL RATING LOWER THAN CLASS "A ".
12. ALL LAMPS AND BALLASTS SHALL BE UL APPROVED AND FROM A MAYOR
MANUFACTURER. LAMPS AND BALLASTS SHALL BE ENERGY SAVING TYPE
AND SHALL HAVE A PROPER MATCHING AND COMPATIBILITY
13. AC -3 VENTILATION SYSTEM ON -OFF SWITCH, SHALL BE WIRED THROUGH THE
VARIAN VAULT DOOR OPERATOR. REFER TO UNIT MANUFACTURER WIRING
REQUIREMENTS. EF -5 SHALL BE INTERLOCK WITH AC -3 PER MECHANICAL
SEQUENCE OF OPERATION, REFER TO MECHANICAL DRAWINGS.
14. CT EXHAUST FAN EF -6 (80W, 120V, 1PH) SERVING CT AREA OPERATED WITH
MOTOR SWITCH LOCATED NEXT TO SINK COUNTER. VERIIFY EXACT LOCATIONS
WITH MECANICAL CONTRACTOR AT FIELD BEFORE ROUGHING -IN.
PROVIDE ALL LIGHTING, POWER AND SYSTEMS REQUIRED FOR THE COMPLETION OF MEDICAL /TREATMENT
OFFICE AREAS AS SHOWN. REFER TO ARCHITECTURAL LAYOUT DRAWINGS FOR DIMENSIONAL INFORMATION
REFER TO MEDICAL /DIAGNOSTIC EQUIPMENT UNIT MANUFACTURER SHOP DRAWINGS FOR INSTALLATION
REQUIREMENTS AND RECOMMENDATIONS. CONTRACTOR SHALL USE THESE CONTRACT DOCUMENTS AND
MEDICAL EQUIPMENT MANUFACTURER SHOP DRAWINGS DURING CONSTRUCTION AND BIDDING PHASES.
CITY OF 8)0U•rH N"iIAN'll
BUIL0Iy(3 0EPT.
E! ECTRICAL SECTION
APPROVED 3Y :.,:�
H
U
WM
g
M
M
U
9 N N
Z
�
39�0
W
�
0
uj a
�3� o
a,p
• 1w
�W
o�
u�
F—
Z
W
con N
O
W
0 3
CL U w
I—
W
h-
W0�
.� w
�-- = M
Z u aQ
Z W ~�
W W
!U)>
00
O�
a_
yy 4 O;s
p L4
mIgMilo '310
sp�Sp7[� % -Pgawl e_g
Wy413 �Q �UWN
ol��
DATE: 03/14/07
PROJ NO: -
OWG 8Y: JE8
REV:
04/06/07
Q11/16/2007
1 FIEIO_CHG.
12/10/2007
IT- REVISION
02/04/2008
CT -CHG.
E -1
OF 6