07-780R-001PLAN REVIEW DATA
I. OCCUPANCY
FBC OCCUPANCY TYPE: GROUP "B"
NFPA 101 - CHAPTER 38 - NEW BUSINESS OCCUPANCIES
OCCUPANCY LOAD: 1 PERSON/ 100 SQ. FT. = 18 PEOPLE
II. CONSTRUCTION
FBC TYPE III -A
BUILDING IS FULLY SPRINKLERED
III. CODE
2004 FLORIDA BUILDING CODE
NFPA 101 LIFESAFETY CODE, 2003 EDITION
PROJECT AREA = 1600 SQ. FT.
MAXIMUM TRAVEL DISTANCE TO STAIR = 123' -10"
MAXIMUM TRAVEL DISTANCE TO LOBBY EXIT = 112' -3"
GENERAL. NOTES
pm
.:\iobs \M r r War z rc • _ w1q .
0
PROPOSED RENOVATIONS FOR
6141 SUNSET DRIVE SOUTH, MIAMI, FLORIDA
MFR
MANUFACTURER
ADJ
ADJUSTABLE
MIN
1. DO NT SCALE THE DRAWINGS. IF DIMENSIONS ARE IN QUESTION, THE CONTRACTOR SHALL BE RESPONSIBLE
WITH CONSTRUCTION.
AHU
ALT
AIR HANDLER UNIT
ALTERNATE
MTL
FOR OBTAINING CLARIFICATION FROM THE ARCHITECT BEFORE CONTINUING
CASEWORK EQUIPMENT ETC. ARE "SCREENED
2. EXISTING PARTITIONS, DOORS, WINDOWS, PLUMBING FIXTURES, � �
ALUM
AMP
ALUMINUM
AMPERAGE
N.I.C.
BACK" ON THE FLOOR PLANS. NEW CONSTRUC11ON IS INDICATED BY SOLID LINES. REFER TO DEMOLITION
BD
BOARD
O.C.
DRAWINGS FOR EXTENT OF EXISTING TO BE REMOVED.
CDU
CONDENSING UNIT
PH
PHONE
CA
CENTERLINE
PLT
3. THE CONTRACTOR SHALL PROVIDE CHASES FOR MECHANICAL, PLUMBING, AND ELECTRICAL AS NECESSARY ?
LG
CLG
CEILING
PTD
TO CONCEAL. REFER TO RESPECTIVE DRAWINGS AND SECTIONS.
CLR
CLEAR
PNT
LOCATED ABOVE GRADE AND INSIDE THE BUILDING SHALL BE CONCEALED IN FURRED SPACES WITH
CCMU MU
CONCRETE MASONRY UNIT
CONCRETE
RAD
4. PIPING
THE EXCEPTION OF PIPING IN STAIRWAYS, EQUIPMENT ROOMS AND IN THE POWERHOUSE. THE CONTRACTOR SHALL
CPT
CARPET
REF
COORDINATE WITH THE OTHER TRADES TO PROVIDE FURRING FOR PIPING INSTALLED IN FINISHED AREAS. THE
"FURRED'
CTB
CERAMIC 11lE BASE
RM
CONTRACTOR SHALL GAIN APPROVAL FROM THE ARCHITECT PRIOR TO LOCATING AND /OR PROVIDING
CTF
CERAMIC 11LE FLOOR
Sc
SPACES" NOT INDICATED ON THE FLOOR PLANS.
CTW
CERAMIC TILE WALL
SHWR
SHOWER
DBL
DOUBLE
SLG
5. FOR ALL RATED PARTITIONS, THE SURFACE AREA OF INDIVIDUAL RECESSED METALLIC OUTLET, SWITCH 80X �
DEMO
DEMOLITION
STD
AND OTHER ITEMS, SHALL NOT EXCEED 16 SQUARE INCHES. THE AGGREGATE SURFACE AREA OF THE RECESSED
DIA
DIAMETER
TEMP
OUTLETS, BOXES, ETC. SHALL NOT EXCEED 100 SQUARE INCHES PER 100 SQUARE FEET OF SURFACE WALL AREA.
DIM
DIMENSION
TPD
RECESSED BOXES LOCATED ON OPPOSITE SIDES OF THE WALL'S OR PARTITIONS, REGARDLESS OF THEIR
D.R.
DRESSING ROOM
T.O.S.
VERTICAL SEPARATION IN THE WALL, SHALL BE SEPARATED BY A HORIZONTAL DISTANCE OF 24 INCHES.
D.S.
DOWN SPOUT
U.N.O.
UNLESS NOTED OTHERWISE
DTL
DETAIL
W/
6. REFER TO DRAWING SHEET A -2 FOR DOOR AND DOOR FRAME SCHEDULE AND TOILET ACCESSORIES SCHEDULE.
EA
EACH
VWC
VINYL WALL COVERING
ELEV
ELEVATION
VCT
7: THE CONTRACTOR SHALL VERIFY THAT ACCESS PANELS OF TYPE SPECIFIED ARE INSTALLED IN WALLS AND
EQ
EQUAL
NON- ACCESSIBLE TYPE CEILINGS AND SOFFITS WHERE ACCESS, SERVICE OR ADJUSTMENTS TO MECHANICAL,
EWC
ELECTRIC WATER COOLER
PLUMBING, OR ELECTRICAL ITEMS MAY BE REQUIRED. ACCESS PANELS SHALL BE FIRE RATED TYPE EQUAL TO
EXH
EXHAUST
THE RATING OF THE WALL, SOFFIT OR CEILING IN WHICH THEY OCCUR.
EXT
EXTERIOR
MU
FAN COIL UNIT
8. ROOMS SCHEDULED TO RECEIVE EXPOSED CEILING SHALL HAVE THEIR SURROUNDING WALLS EXTENDED TO THE
FEC
FIRE EXTINGUISHER CABINET
UNDERSIDE OF FLOOR/ ROOF ABOVE. '
FIN
FINISH
9. THE DRYWALL CONTRACTOR SHALL PROVIDE ACCESS PANELS AT DRYWALL CEILINGS TO PROVIDE ACCESS
FLR
FLUOR
FLOOR
FLUORESCENT
TO RATED PARTITIONS (30' -0" O.C. MAX OR 1 PER ROOM MINIMUM)
FIG
FOOTING
10. ALL RECESSED FIRE EXTINGUISHER CABINETS (FECS) SHALL HAVE AN 8" MIN. DEEP CHASE TO ACCOMODATEj
GA
GAUGE
11. THE FLOOR SLAB SHALL BE SLOPED (MIN 1/8 "/ V -0 ") TO DRAIN. DO NOT INTERRUPT INTEGRITY OF FIRE RAjING
GALV
GB
GALVINIZED
GRAB BAR
OF RAISED FLOOR SLBS.
GFI
GROUND FAULT CIRCUIT
12. THE CONTRACTOR SHALL PROVIDE SHOP DRAWINGS, PROJECT SPECIFICATIONS/ CUT SHEETS, PHOTOGRAPHS
DEVICES AND UGH11N
GYP
HC
GYPSUM BOARD
HOLLOW CORE
AND COLOR CHOICE/ SAMPLES FOR ALL CASEWORK, PLUMBING FIXTURES, ELECTRICAL
HDR
HEADER
FIXTURES, DOOR HARDWARE AND TOILET ACCESSORIES FOR THE APPROVAL OF THE TENANT PRIOR TO
INSUL
INSULATION
PROCUREMENT.
TNT
INTERIOR
LAV
LAVATORY
MAX
MAXIMUM
pm
.:\iobs \M r r War z rc • _ w1q .
0
PROPOSED RENOVATIONS FOR
6141 SUNSET DRIVE SOUTH, MIAMI, FLORIDA
MFR
MANUFACTURER
MEX
MATCH EXISTING
MIN
MINIMUM
MTD
MOUNTED
MTL
METAL
MWO
MICROWAVE OVEN
N.I.C.
NOT IN CONTRACT
N.T.S.
NOT TO SCALE
O.C.
ON CENTER
PB
PUSH BUTTON
PH
PHONE
PLAM
PLASTIC LAMINATE
PLT
PLATE
PLYWO
PLTWOOD
PTD
PAPER TOWEL DISPENSER
PR
PAIR
PNT
PAINTED
P.T.
PRESSURE TREATED
RAD
RADIUS
RCP
REFLECTED CEILING PLAN
REF
REFRIGERATOR
REV
REVERSE
RM
ROOM
R.O.
ROUGH OPENING
Sc
SOLID CORE
SHT
SHEET
SHWR
SHOWER
SIM
SIMILAR
SLG
SLIDING
SS
STAINLESS STEEL
STD
STANDARD
SVF
SHEET VINYL FLOORING
TEMP
TEMPERED GLASS
THK
THICK
TPD
TOILET PAPER DISPENSER
T.O.C.
TOP OF CURB
T.O.S.
TOP OF STEEL
TYP
TYPICAL
U.N.O.
UNLESS NOTED OTHERWISE
UC REF
UNDER COUNTER REFRIGERATOR
W/
WITH
WD
WOOD
VWC
VINYL WALL COVERING
W.P.
WEATHERPROOF
VCT
VINYL COMPOSITE TILE
VSF
VINYL SHEET FLOORING
i
GRAPHIC SYMBOLS LEGEND I I SHEET INDEX
,/— INDICATES DETAIL OR
/ SECTION NUMBER
2
A3.2 -"a-- INDICATES SHEET ON
WHICH DETAIL OR
SECTION IS SHOWN
T, C(OLUMN REFERENCE
if GBRIDS
0
HCHITECTURE, LC
irm Cert. No. AA2600115
210 Windy Preserve
Lake Worth, Florida 33467
hone: (561)649 -5025
ax: (561) 649 -5025
FIH6 -Mail: MDT ArchAcomcast.net
ark D Taudien' AIA
rinciaal
w .11 Au
a,
INDICATES DETAIL OR SHEET SHEET TITLE RELEASE DATE FOR LATEST REVISION REVISION
5- te- NO. CONSTRUCTION DATE NUMBER(S)
ENLARGED PLAN NUMBER TITLE GENERAL NOTES
A4.1 INDICATES SHEET ON A -1 FLOOR PLAN - NEW CONSTRUCTION
— WHICH DETAIL OR A -2 ELEVATIONS
ENLARGED PLAN IS A -3 DETAILS
SHOWN
L J A -4 DETAILS
A -5 FLOOR PLAN - REFLECTED CEILING
M -1 FLOOR PLAN - MECHANICAL
M -2 MECHANICAL DETAILS
f - INDICATES ELEVA11ON M -3 MECHANICAL DETAILS
7 NUMBER M -4 MECHANICAL DETAILS
6 A -2 4 M -5 MECHANICAL SCHEDULES
M -6 MECHANICAL SPECIFICATIONS
5 INDICATES SHEET FP -1 FLOOR PLAN - FIRE PROTECTION
REVISION ON WHICH ELEVATION P -1 FLOOR PLAN - PLUMBING
FEC RECESSED FIRE EXTINGUISHER
CABINET WITH 51b ABC EXTINGUISHER
SURFACE MOUNTED
O Ib "ABC EXTINGUISHER
t54 MAX. MOUNTING HEIGHT)
XXX CEILING
XXX -WALLS
XXX BASE
XXX = FLOOR
FLOORING TRANS111ON
IS SHOWN
E -1
ELECTRICAL SYMBOLS
E -2
FLOOR PLAN - LIGHTING
E -3
FLOOR PLAN - POWER AND
E -4
ELECTRICAL RISER DIAGRAM'
E -5
ELECTRICAL DETAILS
E -6
ELECTRICAL SPECIFICATIONS
CLOSER SPACING IS INDICATED) SEE DETAIL
TO METAL STUDSWGYPSUM BOARD PARTITIONS, SEE THE SPECIFICATIONS IN THE PROJECT MANUAL AND THE
�XX -XX
ACCENT AND/ OR
SPECIFIC FINISH
WALLS/ PARTITIONS LEGEND
GENERAL NOTES FOR WALLS/ PARTITIONS
EACH INDIVIDUAL WALL/ PARTITION ASSEMBLY SHALL COMPLY WITH THE TESTED ASSEMBLY REFERENCED BELOW.
'
FOR ALL WALL/ PARTITION ASSEMBLIES USING GYPSUM BOARD, THE CONTRACTOR SHALL COMPLY WITH ALL
ONE HOUR RATED WALL
REQUIREMENTS Of THE MOST CURRENT EDITION OF THE GYPSUM ASSOCIATION GA -600 FIRE RESISTANCE DESIGN
MANUAL AND THIS MOST CURRENT EDITION OF THE UNDERWRITERS LABORATORIES U.L. FIRE RESISTANCE
3 5/8" METAL STUDS AR V -4" MAX. O.C. (UNLESS
DIRECTORY. SEE DETAIL 1/A8.1 "LOCATION OF JOINTS IN GYPSUM BOARD PARTITIONS ". FOR DETAILS PERTAINING
CLOSER SPACING IS INDICATED) SEE DETAIL
TO METAL STUDSWGYPSUM BOARD PARTITIONS, SEE THE SPECIFICATIONS IN THE PROJECT MANUAL AND THE
10 /A8.1
DETAILS IN THESLE DRAWINGS FOR CORRECT GAUGE OF METAL STUDS.
ONE LAYER 5/8" TYPE "X" GYPSUM. BOARD EACH
PARTITIONS THATI' ARE REQUIRED TO EXTEND TO THE DECK ABOVE SHALL HAVE THE GYPSUM BOARD CUT TO FIT
SIDE, APPLIED VERTICALLY. STAGGER ALL
WITHIN A 1/4" MIAXIMUM TOLERANCE TO THE SHAPE OF THE DECK ABOVE; AND ALL LAYERS OF THE GYPSUM
VERTICAL JOINTS MIN 1' -4" O.C. AND STAGGER
ALL HORIZONTAL JOINTS MIN 2' -O" O.C. APPLY
BOARD SHALL BE SEALED FOR THE FULL DEPTH OF THE-GYPSUM BOARDS WITH FLEXIBLE SEALANT.
1" TYPE "S" STEEL SCREWS AT 8" O.C. ALONG
THE GYPSUM BOARD SHALL BE CUT SO THAT THE CLEARANCE BETWEEN METALLIC ELECTRICAL OUTLET BOXES
EDGES OF BOARD AND AT 1' -0" O.C. IN THE
AND THE GYPSUW BOARD DOES NOT EXCEED 1/8 ". --
FIELD OF THE BOARD.
SEAL GYPSUM BOARD TO FLOOR SLAB BELOW
THE GYPSUM BOARD SHALL BE CUT TO FIT WITHIN A 1/4" MAXIMUM TOLERANCE AROUND ALL PENETRATIONS AND
WITH FLEXIBLE SEALANT.
SHALL BE SEALEID FOR THE FULL DEPTH OF THE GYPSUM BOARD WITH A FLEXIBLE SEALANT.
EXTEND GYPSUM BOARD TO DECK ABOVE AND
THE BOTTOM OF THE GYPSUM BOARD ON ALL PARTITIONS SHALL BE 1/4" MINIMUM AND 1/2" MAXIMUM ABOVE THE
SEAL WITH FLEXIBLE SEALANT. SEAL ALL
CONCRETE SLAB AND SHALL BE SEALED FOR THE FULL DEPTH OF THE GYPSUM BOARD WITH FLEXIBLE SEALANT.
PENETRATIONS.
IF THE GYPSUM IBOARD IS NOT CUT 11GHT TO THE FLOOR SLAB BELOW, TO THE DECK ABOVE AND AROUND
SEE "GENERAL NOTES FOR WALLS/ PARTITIONS"
PENETRATIONS, VMTHIN THE MAXIMUM TOLERANCES AS NOTED ABOVE, THE CONTRACTOR SHALL BE REQUIRED TO
ABOVE FOR ADDITIONAL REQUIREMENTS
PROVIDE A TESTEED FIRESTOP ASSEMBLY FOR THE APPROPRIATE "JOINT SYSTEM" "THROUGH - PENETRATION
FIRESTOP SYSTEMS ", ETC. PER THE REQUIREMENTS OF THE MOST CURRENT EDITION OF THE U.L. FIRE RESISTANCE
THIS PARTITION SHALL ALSO COMPLY WITH ALL
DIRECTORY - VO)LUME 2. COMPLY WITH REQUIREMENTS OF SPECIFICATIONS SECTION - 7841 - THROUGH - PENETRATION
REQUIREMENTS OF U.L. DESIGN NUMBER U465.
FIRESTOP SYSTEMS.
INSTALL SOUND ATTENUATION BLANKETS FROM
FLOOR TO DECK.
PARTITION SHALL BE IN ACCORDANCE WITH U.L.
DESIGN No. U -465.
NON -RATED PARTITION TO DECK
3 5/8" METAL STUDS AR 1' -4" MAX. O.C. (UNLESS
CLOSER SPACING IS INDICATED) SEE DETAIL
10 /A8.1
ONE LAYER 5/8" TYPE "X" GYPSUM BOARD EACH
SIDE, APPLIED VERTICALLY. STAGGER ALL
VERTICAL JOINTS. HORIZONTAL JOINTS ARE NOT
REQUIRED TO BE STAGGERED, BUT THEY SHALL
ALWAYS OCCUR ABOVE THE CEILING.
SEAL GYPSUM BOARD TO FLOOR SLAB BELOW
WITH FLEXIBLE SEALANT.
EXTEND GYPSUM BOARD TO DECK ABOVE AND
SEAL WITH FLEXIBLE SEALANT. SEAL ALL
PENETRATIONS WITH FLEXIBLE SIfAL.ANT
INSTALL SOUND ATTENUATION BLANKETS FROM
FLOOR TO DECK. SEE SPECIFICATIONS SECTION
09260 FOR SIZE AND TYPE TO BE USED.
NO.
CONSULTANTS
SEAL
ti' w
ARCH. 6P RECOMID
MARK D. TAUDIEN
AR 0011821
Q
0
0
.. � L.L.
OF�
CC^
G
Q
LL
W I�L�
z<
0 _
F
0
0 = cn
z W
w >
0� u)
0
U w
0 U)
CL z
0
0. v) ��^
CL r
d'
t�
REVISION
SHEET
TITLE
a
z
Z
J
U
Cn
w
F-
0
z
w
z
w
DATE
e
PROJ. NO. 07 -11 -01
DATE: DEC. 10, 2007
i