Loading...
06-785-013SEE PLANS FOR QUANTITY 3' Ni- X 2 1/2' WIDE ALUMINUM RAIL 1 1 /2•X1 1/2' ALUMINUM SQUARE PITCH PAN MAKE LENGTH ARD WIDTH OF AREA DEFINED BY QASE PLATE DIM. PLUS 2 ALL MOUND 1 1/2'X, 1/2' ALUMINUM SOUARE �• 4' 4' BASE PLATE - -- 2 -3 HILTI 'KWIC' BOLTS W W/2 1/2' MINIMUM EMBEDMENT (TYPICAL EACH BASE PLATE) 2 -31W THROUGH BOLTS WITH NUTS WHERE LEGS NOT LOCATED ABOVE JOIST ROOF JOIST 4'x4"1 /4•ALUNIN. BASE SEE DETAIL BELOW. A1YP�ICAL AT EACH VERTICAL 1M DETAIL *4 COMPLIANCE WITH FLORIDA BUILDING CODE AS°A AS EAjYRAiE sIS,MS ° NU C S1O 3411) BUSINEES PARKWAY. ROYAL PALM BEACH. ] METAL PLATE/WASHER BOLTS THRU CURB. ROOF DECK AND JOIST OR WELD CURB TO ROOF DECK. USE CONCRETE ANCHORS IN POURED DECKS. HOLE FOR 3/ GALVANIZED STEEL 'HL T' WK B OLT WATN 4' MINIMUM EMBEDMENT INTO CONCRETE ,. SOUE TUB GALUMINUN 1 4•,4'x1/4' ALUMINUM BASE CONDENSING UNIT PREFABRICATED SUPPORT DETAIL N.T.S. PATE STAINLESS ADJUSTABLE CLAMP. PATE SPUN ALUMINUM BASE. PATE STEPPED PVC BOOT STRIPING MASTIC _.._.._.._.._ - MEMBRANE BUILT UP ROOF ROOF PIPE SEAL N.T.S. SPRING & NEOPRENE TYPE VIBRATION ISOLATORS TYP. 3/8" HANGING RODS (THREADED) COORDINATE W/ STRUCTURAL ENGINEER AND /OR ARCH. ON HOW TO FASTEN TO STRUCTURE MOUNTING CLIPS OR UNITS CONNECTION TO SUPPORT RODS AS RECOMMENDED BY MFG. ELECTRIC HEAT ASSEMBLY FLEXIBLE DUCT CONNECTOR - SUPPLY AIR DUCT SMOKE DETECTOR IN SUPPLY AIR DUCT AS REQUIRED TRANSITION AS REQUIRED PROVIDE 24" SERVICE CLEARANCE FOR ALL ACCESS PANELS TRANSITION AS REQ'D. RETURN AIR DUCTWORK OUTSIDE AIR DUCT W/ OPPOSED BLADE DAMPER F""� (TYPICAL) FILTER & RACK ASSEMBLY 1" GALV. DRAIN PAN i STRAPPED TO A.H.U. INSULATED CONDENSATE DRAIN AND TRAP (SEE PLUMB. FOR CONTINUATION) — REFRIGERANT LINES TO ' CONDENSING UNITS INSULATE SUCTION LINE) AUX. DRAIN (SEE PLUMB. FON CONTINUATION) AIR HANDLING UNIT A.H.U. HANGING DETAIL N.T.5. LIQUID CONIC SLAB STEEL SLEEVE 20 GAUGE SHEET -METAL (SIZE AS REQ'D)— FLASHING AS RECOM. BY MANUF. FILL SLEEVE WITH FIRE - PROOF/ FIRE RESISTANT SILICON SEALANT FOAM CTC. PR -855 SEE ENLARGED DETAIL THIS DWG. 25/50 RATED INSUJLATION SUCTION LINE REFRIGERANT LINES FROM ACCU'S ROOF SLAB REFRIGERANT PIPE RAINCOVER DETAIL N.T.S. ONE PIECE HINGED STEEL SHELL FLASHING AS RECOMMENDED BY MANUFACTURER PITCH PAN TYPE SUPPORT CURB — ISOLATING PAD FOR NON INSULATED LINES & ARMAFLEX (25/50 RATED) FOR INSULATED LINES /—ALUMINUM STRUTS 1 -5/8' X 1 -5/8' X .105' THICK (2.6MM) BY B -LINE OR APPROVED EQUAL COPPER LINE PAINT ALL EXTERIOR REFRIGERANT INSULATION WITH 2 COATS OF WHITE ARMA -FLEX PROTECTIVE 07/ PAINT. TYPICAL REFRIGERANT LINES CLAMPED TO CURB INSULATE ALL REFRIGERANT SUCTION LINES WITH 3/4' THICK ARMAFLEX INSULATION OR APPROVED EQUAL I' (- TYP. ROOF STRUCTURE REFRIGERANT LINE SUPPORT DETAIL • a. d FLAT BAR ROD SONCRETE INSERTS ml2f O ° RETAINING HANGER ° CLIP ROD C -CLAMP TO STRUCTURAL FLANGE W/ RETAINING CLIP OR LOCK NUT MANUFACTURED CONCRETE INSERT . s -l--STRAP X1 HANGER HANGER FOR DUCTS UP TO 18' FOR DUCTS UP TO 36' MAXIMUM DIMENSION MAXIMUM DIMENSION DRIVE PIN THREADED STUD POWDER ACTUATED FASTENERS DUCT SUPPORT SYSTEM FOR ALL EXPOSED DUCT • �• ' ' iii «l 1SHER STRAP_ ROD T POWER ACTUATED STUDS INTO ST (STR H -T 1R OR D K) x HANGER HANGER STRA ROD WELDED STUDS INTO STEEL (STRUCTURE OR DECK) STRAP FOR DUCTS Ui FRICTION CLAMPS TO 18' MAX. STRAP DIMENSION WASHER EXPANSION SHIELDS EXPANSION NAIL WASHER LNUT CONCRETE AN -HORS NOTE, CONSTRUCTION AND INSTALLATION SHALL BE AS PER SMACNA STANDARD FOR TYPE OF DUCTWORK INSTALLED IN FACILITY. UPPER ATTACHMENT METHODS OF HANGING DUCTS AND EQUIPMENT DETAIL N.T.S. LOW VELOCITY SUPPLY OR RETURN AIR DUCT SPIN -IN COLLAR WITH VOLUME DAMPER OPERATOR TO BE OUTSIDE THE INSULATION. PROVIDE INSULATION GUARD WHERE ` NECESSARY (DAMPER WHERE NOTED). (PROVIDE DUCT DAMPERS WHERE ACCESSIBLE) INSULATED FLEX DUCT SEAL JOINT WITH DUCT SEALER INSULATE OR LINE SURFACES TO PREVENT CONDENSATION. �- CEILING DIFFUSER OR RETURN REGISTER. FLEXIBLE DUCT CONNECTION DETAIL N.T.S. 1/2" HANGER ROD (4 REQ'D.) FASTENED TO CONCRETE STRUCTURE ABOVE WITH EXPANSION BOLTS. HILTI KWIK BOLT ElXP. ANCHOR. ROD COUPLING TYPE 2 1/4" EMBEDMENT. 'ORT CROSS E (IF REQUIRED) HANGER ROD SPRING ISOLATOR E FAN BOTTOM HUNG HANGER ROD A.H.U. OR INLINE FAN BEYOND INLINE FAN OR A/C UNIT MOUNTING DETAIL N.T.S. ALL DAMPERS SHALL COMPLY WITH NFPA 90A UL 555 CONDENSING UNIT (TrPICAU 1 ANCHOR CONDENSING UNIT WITH 2 -/10 SCREWS SELF THREADED EACH SIDE OF STRAP TO 42 BEAMS USING MIN. 1' WADE. 22 GA. GALVANIZED STRAPS (TYPICAL EACH CORNER) 3 2•,2'x1/4• THICK ISOMME 4 NEOPRENE PAD (TYPICAL EACH 4 CORNER) 4'x4"1 /4•ALUNIN. BASE SEE DETAIL BELOW. A1YP�ICAL AT EACH VERTICAL 1M DETAIL *4 COMPLIANCE WITH FLORIDA BUILDING CODE AS°A AS EAjYRAiE sIS,MS ° NU C S1O 3411) BUSINEES PARKWAY. ROYAL PALM BEACH. ] METAL PLATE/WASHER BOLTS THRU CURB. ROOF DECK AND JOIST OR WELD CURB TO ROOF DECK. USE CONCRETE ANCHORS IN POURED DECKS. HOLE FOR 3/ GALVANIZED STEEL 'HL T' WK B OLT WATN 4' MINIMUM EMBEDMENT INTO CONCRETE ,. SOUE TUB GALUMINUN 1 4•,4'x1/4' ALUMINUM BASE CONDENSING UNIT PREFABRICATED SUPPORT DETAIL N.T.S. PATE STAINLESS ADJUSTABLE CLAMP. PATE SPUN ALUMINUM BASE. PATE STEPPED PVC BOOT STRIPING MASTIC _.._.._.._.._ - MEMBRANE BUILT UP ROOF ROOF PIPE SEAL N.T.S. SPRING & NEOPRENE TYPE VIBRATION ISOLATORS TYP. 3/8" HANGING RODS (THREADED) COORDINATE W/ STRUCTURAL ENGINEER AND /OR ARCH. ON HOW TO FASTEN TO STRUCTURE MOUNTING CLIPS OR UNITS CONNECTION TO SUPPORT RODS AS RECOMMENDED BY MFG. ELECTRIC HEAT ASSEMBLY FLEXIBLE DUCT CONNECTOR - SUPPLY AIR DUCT SMOKE DETECTOR IN SUPPLY AIR DUCT AS REQUIRED TRANSITION AS REQUIRED PROVIDE 24" SERVICE CLEARANCE FOR ALL ACCESS PANELS TRANSITION AS REQ'D. RETURN AIR DUCTWORK OUTSIDE AIR DUCT W/ OPPOSED BLADE DAMPER F""� (TYPICAL) FILTER & RACK ASSEMBLY 1" GALV. DRAIN PAN i STRAPPED TO A.H.U. INSULATED CONDENSATE DRAIN AND TRAP (SEE PLUMB. FOR CONTINUATION) — REFRIGERANT LINES TO ' CONDENSING UNITS INSULATE SUCTION LINE) AUX. DRAIN (SEE PLUMB. FON CONTINUATION) AIR HANDLING UNIT A.H.U. HANGING DETAIL N.T.5. LIQUID CONIC SLAB STEEL SLEEVE 20 GAUGE SHEET -METAL (SIZE AS REQ'D)— FLASHING AS RECOM. BY MANUF. FILL SLEEVE WITH FIRE - PROOF/ FIRE RESISTANT SILICON SEALANT FOAM CTC. PR -855 SEE ENLARGED DETAIL THIS DWG. 25/50 RATED INSUJLATION SUCTION LINE REFRIGERANT LINES FROM ACCU'S ROOF SLAB REFRIGERANT PIPE RAINCOVER DETAIL N.T.S. ONE PIECE HINGED STEEL SHELL FLASHING AS RECOMMENDED BY MANUFACTURER PITCH PAN TYPE SUPPORT CURB — ISOLATING PAD FOR NON INSULATED LINES & ARMAFLEX (25/50 RATED) FOR INSULATED LINES /—ALUMINUM STRUTS 1 -5/8' X 1 -5/8' X .105' THICK (2.6MM) BY B -LINE OR APPROVED EQUAL COPPER LINE PAINT ALL EXTERIOR REFRIGERANT INSULATION WITH 2 COATS OF WHITE ARMA -FLEX PROTECTIVE 07/ PAINT. TYPICAL REFRIGERANT LINES CLAMPED TO CURB INSULATE ALL REFRIGERANT SUCTION LINES WITH 3/4' THICK ARMAFLEX INSULATION OR APPROVED EQUAL I' (- TYP. ROOF STRUCTURE REFRIGERANT LINE SUPPORT DETAIL • a. d FLAT BAR ROD SONCRETE INSERTS ml2f O ° RETAINING HANGER ° CLIP ROD C -CLAMP TO STRUCTURAL FLANGE W/ RETAINING CLIP OR LOCK NUT MANUFACTURED CONCRETE INSERT . s -l--STRAP X1 HANGER HANGER FOR DUCTS UP TO 18' FOR DUCTS UP TO 36' MAXIMUM DIMENSION MAXIMUM DIMENSION DRIVE PIN THREADED STUD POWDER ACTUATED FASTENERS DUCT SUPPORT SYSTEM FOR ALL EXPOSED DUCT • �• ' ' iii «l 1SHER STRAP_ ROD T POWER ACTUATED STUDS INTO ST (STR H -T 1R OR D K) x HANGER HANGER STRA ROD WELDED STUDS INTO STEEL (STRUCTURE OR DECK) STRAP FOR DUCTS Ui FRICTION CLAMPS TO 18' MAX. STRAP DIMENSION WASHER EXPANSION SHIELDS EXPANSION NAIL WASHER LNUT CONCRETE AN -HORS NOTE, CONSTRUCTION AND INSTALLATION SHALL BE AS PER SMACNA STANDARD FOR TYPE OF DUCTWORK INSTALLED IN FACILITY. UPPER ATTACHMENT METHODS OF HANGING DUCTS AND EQUIPMENT DETAIL N.T.S. LOW VELOCITY SUPPLY OR RETURN AIR DUCT SPIN -IN COLLAR WITH VOLUME DAMPER OPERATOR TO BE OUTSIDE THE INSULATION. PROVIDE INSULATION GUARD WHERE ` NECESSARY (DAMPER WHERE NOTED). (PROVIDE DUCT DAMPERS WHERE ACCESSIBLE) INSULATED FLEX DUCT SEAL JOINT WITH DUCT SEALER INSULATE OR LINE SURFACES TO PREVENT CONDENSATION. �- CEILING DIFFUSER OR RETURN REGISTER. FLEXIBLE DUCT CONNECTION DETAIL N.T.S. 1/2" HANGER ROD (4 REQ'D.) FASTENED TO CONCRETE STRUCTURE ABOVE WITH EXPANSION BOLTS. HILTI KWIK BOLT ElXP. ANCHOR. ROD COUPLING TYPE 2 1/4" EMBEDMENT. 'ORT CROSS E (IF REQUIRED) HANGER ROD SPRING ISOLATOR E FAN BOTTOM HUNG HANGER ROD A.H.U. OR INLINE FAN BEYOND INLINE FAN OR A/C UNIT MOUNTING DETAIL N.T.S. ALL DAMPERS SHALL COMPLY WITH NFPA 90A UL 555 ■ 1 N 0 DUCT o O ACCESS DOOR 2 —0 C t�3 INSULATION WHERE DUCTS o 3 ARE SO SPECIFIED 4 N FLOOR O ROOM) T IN M rn EQUIPM NTE o \J O NOT USED. 12 6 CLEARANCE PER 12" OF O � DUCT DUCT ON ALL FOUR SIDES m M 7O COLLAR (SEE NOTES) 10 9 8O 1" TYP. ALL FOUR SIDES 0 0 9� 1- 1/2 "x1- 1/2'x10 GA. OR HORIZONTAL MOUNTING DETAIL a� HEAVIER ANGLES SNUG TO U FLOOR & COLLAR ALL d w AROUND CLOSER 10 'S' SUP 6 11 B ANGLE AS REQ'D 11 WALL 7 BY LOCAL BLDG. 12 FLOOR SLAB DEPT. NOTES: 1. COLLAR GAUGES: 1 2 A. FOR COLLARS NOT EXCEEDING 36 "W OR 24 "H - 16 GAUGE 3 B. FOR COLLARS EXCEEDING 36'W OR 24 "H - 14 GAUGE 2. ATTACH ANGLES TO COLLARS OR (/10 TEC SCREWS) WITH 1/4" 20 BOLTS & 9 10 NUTS 12" C -C MAX. MIN. 2 BOLTS IN EACH SIDE TOP & BOTTOM 3. INSTALLATION SHALL CONFORM VERTICAL MOUNTING DETAIL TO NFPA -9OA 4. PROVIDE ACCESS DOORS TO SERVICE FUSIBLE LINKS AS REQUIRED NOTE: TYPE "B' IS DETAILED FOR ALL SUPPLY AIR DUCTS TYPE "A" MAY BE USED FOR ALL RETURN ARE DUCTS AS REQUIRED. ALL MOTORIZED FIRE SMOKE DAMPERS SHALL BE FSO -60 TYPE. TYPICAL STYLE "B" FIRE DAMPER DETAIL T. . LW�� 201oo n.e. 21 avenue no. miami beach, fl 33179 v ■ m N U o w —0 C a ._ o I INw h� rn N 0 M rn U o ho O L0 � � m m M Um LL its 0 0 Cf m a� U d w O LZ W Or 13039 c }. v DRAWN M. R. CHECKED R.P. DATE 11 -30 -05 SCALE AS NOTED JOB NO. 0423 SHEET M -5 OF G SHEETS ■ Q ■ (/10 w —0 C L.L_ 0 co INw h� LL 0 Q co cc W � � m w >O D Um LL its 0 0 a� w Zo w O LZ W p W }. DRAWN M. R. CHECKED R.P. DATE 11 -30 -05 SCALE AS NOTED JOB NO. 0423 SHEET M -5 OF G SHEETS