06-782R-020REMOVABLE T HANDLE 3/4' HOSE THREAD V ; . ii I� 3/4' CONNECTION LESS FLANGE WHERE PIPING OUCH CHROME PLATED -VACUUM BREAKER (VANDAL PROOF) HOSE BIBB DETAIL N.T.S. PROVIDE WEATHER PROOF CAP TURN HEAD PIPE DOWN INTO STACK FOR FUTURE TENANT AREAS---______._ I f SHEET LEAD FLASHING MOP IN W/ ROOFING MATERIAL 12' MIN. VENT STACK NOTE, ANY VENT FIRE WITHIN 10' -0' OF ANY DOOR, WINDOW, OR EXHAUST OPENINGS SHALL EXTEND NOT LESS THAN 3' -0' ABOVE SUCH z 2 ROOFING ROOF CONSTRUCTION SLEEVE ROOF CONSTRUCTION AS REQUIRED VENT THRU ROOF DETAIL N.T.S. 'a 12 "x1 2 "x8" POURED CONC. BLOCK WHEN CLEANOUT IS NOT IN PAVED AREA 2 -WAY, CLEAN -OUT AT GRADE ZURN 2N -1400 CLEAN -OUT COVER •,Q�•10.•O,N 4o p.yot°•j°W,e: ie, o,,.•J°,.Cet SAME SIZE AS SEWER -MAX. SIZE 4" 1 -WAY, INTERIOR CLEAN OUT BROOKS TRAFFIC BOX p1 -RT COVER & BODY (TYP.) SAME SIZ SEWER - SIZE 4-(T PAVING 2 -WAY, CLEAN -OUT AT PARKING AREA LAVATORY J.R. SMITH #2698 WATER SAVER TRAP PRIMER CLEANOUT PLUG J FINISHED FLOOR FINISHED WALL FLOOR DRAIN TRAP PRIMER DIAGRAM N.T.S. WASH 9 STAINLESS STEEL COVER SCREWED TO THREADED C.O. PLUG FACE OF WALL WALL -TYPE CLEAN -OUT FINISH GRADE •c •�°• Jot.+, POURED -SAME SIZE AS POURED CONC. BLOCK WHEN SEWER - MAX. CLEANOUT IS SIZE 4" NOT IN LONG SWEEP. USE SHORT PAVED AREA SWEEP WHERE REQUIRES 1 -WAY, CLEAN -OUT AT GRADE TYPICAL CLEAN -OUT DETAILS N.T.S. 171-� A/C UNIT AUXILIARY DRAIN PAN ' 3/4" AUXILIARY DRAIN LINE TO STUB THRU CLG. OVER SINK W/ CHROME ESCUTCHEON PLATE (MAINTAIN PITCH) ROOF STRUCTURE UNION CLEANOUT PLUG TRAP CONDENSATE DRAIN, INSULATED CEILING CONDENSATE TRAP DETAIL N.T.S. THERMAL EXPANSION TANK 3/4' HEAT TRAP HOT WATER TO SYSTEM. P & T RELIEF VALVE ELECTRIC WATER HEATER DRAIN VALVE - FLOOR COLD WATER SUPPLY SHUT -OFF VALVE HEAT TRAP WATER SUPPLY TO HEATER. P & T RELIEF LINE FULL SIZE 3/4" PR LINE TO OUTSIDE, TERMINATE POINTING DOWN 6" ABOVE GRADE. 30.30.3 GALVANIZED DRAINPAN '" DP UNE TO OUTSIDE, TERMINATE POINTING DOWN 6" ABOVE GRADE. WATER HEATER DETAIL N.T.S. HANGER ROD HANGER ROD --------� LOCKING NUT SUPPORT NUT HEAVY DUTY CLEVIS SUPPORT NUT HANGER HEAVY DUTY CLEVIS PIPE HANGER VAPOR BARRIER QINSULATION 16 GAUGE ZINC COATED CLEVIS HANGER SHEET STEEL SADDLE AT LEAST B' LONG SIN . HORIZONTAL RUNS NO VAPOR BARRIER INSULATION CLEVIS HANGER SINGLE HORIZONTAL RUNS WITH VAPOR BARRIER INSULATION WELDS WEB MEMBERS ONE ANGLE ON EACH C � F HANGER NUT SIDE 13 WEB MEMBERS \ \` REST ON TOP OF BENT STRAP 11/2' BOTTOM CHORDS STEEL JOISTS BETWEEN PANEL 3/16. OVER VERT. POINTS. SIZE FOR LOAD LESS OF ANGLE BOTTOM CHORDS OF STEEL JOIS STEEL JOIST HEAVY DUTY CONCRETE STEEL INSERT WITH ELONGATED STRAP •' ° %t�•� • _'4' BEAM BEAM CLAMP INSERT NUT � HANGER ROD CONCRETE INSERT STEEL BEAM HANGER ROD. SIZE AS REG. PIPE SUPPORT- DETAIL N.T.S. (FOR SANITARY & WATER PIPING) PLUMBING NOTES: _ 1. ALL WORKMANSHIP AND MATERIAL SHALL BE IN STRICT ACCORDANCE WITH APPLICABLE LOCAL CODES, RULES AND ORDINANCES. 2. CONTRACTOR SHALL VISIT THE JOB SITE AND THOROUGHLY FAMILIARIZE HIMSELF WITH ALL EXISTING CONDITIONS. 3. ALL MATERIAL SHALL BE NEW. ;^ 4. ALL WORK SHALL BE PERFORMED BY A LICENSED PLUMBING ^ CONTRACTOR IN A FIRST CLASS WORKMANLIKE MANNER. THE COMPLETED SYSTEM SHALL BE FULLY OPERATIVE. 5. ALL EXCAVATION AND BACKFILL AS REQUIRED FOR THIS PHASE OF CONSTRUCTION SHALL BE A PART OF THIS CONTRACT. 6. REQUIRED INSURANCE SHALL BE PROVIDED BY THE CONTRACTOR FOR PROTECTION AGAINST PUBLIC LIABILITY AND PROPERTY DAMAGE FOR THE DURATION OF WORK. 7. CONTRACTOR SHALL SECURE AND PAY FOR ALL PERMITS, FEES, INSPECTION AND TESTS. B. DRAWINGS ARE DIAGRAMMATIC. DO NOT SCALE FOR THE EXACT LOCATION OF FIXTURES, PIPING, EQUIPMENT, ETC. 9. ALL WORK SHALL BE COORDINATED WITH OTHER TRADES TO AVOID INTERFERENCE WITH THE PROGRES OF CONSTRUCTION. REPORT ANY DISCREPANCY TO ENGINEER /ARCHITECT PRIOR TO BEGINING CONSTRUCTION. 10. VERIFY LOCATION, SIZE, INVERTS OF ALL EXISTING UTILITIES PRIOR TO BEGINING CONSTRUCTION. ADVICE ENGINEER OF ANY DISCREPANCIES. 11. WATER PIPING SHALL BE TYPE "L" COPPER FOR 2" AND UNDER AND TYPE "K" COPPER FOR 2 -1/2" AND ABOVE. ALL UNDERGROUND WATER PIPING SHALL BE TYPE "K" COPPER. 12. SOIL, WASTE, VENT AND RAINWATER PIPING SHALL BE SCHEDULE 40 PVC PIPE. 13. AIR CONDITIONING CONDENSATE DRAIN PIPING SHALL BE SCHEDULE 40 PVC PIPE WITH 3/4" ARMAFLEX INSULATION. 14. ALL FIXTURES MUST BE PROVIDED WITH READILY ACCESSIBLE STOPS AND APPROPIATELY MARKED ACCESS PANELS. COORDINATE LOCATIONS WITH GENERAL CONTRACTOR PRIOR TO INSTALLATION. 15. FURNISH AND INSTALL APPROVED AIR CHAMBERS, AT EACH PLUMBING FIXTURE AND P.D.I. APPROVED SHOCK ARRESTORS ON MAIN LINES ON RISERS. ( Z -1700 SERIES ) 16. DIELECTRIC COUPLINGS ARE REQUIRED BETWEEN ALL DISSIMILAR METAL IN PIPING AND EQUIPMENT CONNECTIONS. 17. ISOLATE COPPER PIPE FROM HANGER OR SUPPORTS WITH ISOLATOR PAD (HAIR FELT LINING). 18 ALL FIRE RATED FLOOR AND WALL PENETRATIONS SHALL BE PROPERLY PROTECTED FROM FIRE, SMOKE AND WATER PENETRATION BY FILLING VOIDS BETWEEN PIPE AND WALL/FLOOR SLEEVES WITH FIRE RATED FOAM, CHASE TECHNOLOGY CORP.- CTC PR -855 OR 3M, CP -25 CAULKING OR 303 PUTTY, TO ACHIEVE SAME RATING AS WALLS OR FLOORS. 19. CONTRACTOR SHALL GUARANTEE ALL MATERIALS AND WORKMANSHIP FREE FROM DEFECTS FOR A PERIOD OF NOT LESS THAN ONE (1) YEAR FROM DATE OF ACCEPTANCE BU OWNER. CORRECTION F ANY DEFECTS SHALL BE COMPLETED WITHOUT ADDITIONAL CHARGE AND SHALL INCLUDE REPLACEMENT OR REPAIR OF ANY OTHER PHASE OF THE INSTALLATION WHICH MAY HAVE BEEN DAMAGED. 20. PROVIDE ACCESS PANELS FOR ALL CONCEALED VALVES AND ALL WATER HAMMER ARRESTERS. ACCESS PANELS IN RATED WALLS MUST MAINTAIN THE SAME RATING AND MUST MATCH THE FINISH OF THE WALL IN WHICH IT IS INSTALLED. 21. PROVIDE CHROME PLATED COMBINATION COVER PLATE AND CLEANOUT PLUG OR ACCESS PANEL FOR ALL WALL CLEANOUTS - ZURN ZS -1469 SERIES C.O. OR APPROVED ACCESS PANEL. 22. NO COMBUSTIBLE MATERIAL TO BE USED IN MECHANICAL ROOMS OR IN CEILING SPACES WHERE USED AS RETURN AIR PLENUMS. 23. MINIMUM SLOPE FOR PIPES 2" AND SMALLER SHALL BE 1/4" PER LF., FOR PIPES 3" AND ABOVE MINIMUM SLOPE SHALL BE 1/8" PER LF. 24. INSULATE ALL HOT WATER. 3/4" THICK ARMAFLEX. 25. DRAINS SHALL BE AS FOLLOWS: (ZURN, U.O.N.) ROOF DRAINS (JOSAM, #26000) FLOOR DRAINS ( #ZN415 -P -68) EWC BI -LEVEL (SF2500 WITH SFO140) 26. ALL SHOWER VALVES SHALL BE ANTI - SCALD/ PRESSURE BALANCING. 27. ALL PLUMBING FIXTURES SHALL MEET STATE AND LOCAL CODES. 28. INSULATE ALL HOT WATER, HOT WATER RETURN, RAINWATER, CON- DENSATE LINES, EXHAUST LINES ABOVE GRADE AND FIRST 8' -0" OF COLD WATER LINE FROM WATER HEATER /BOILER AS FOLLOWS: CW, HW SUPPLY AND RETURN - 1" THICK PREFORMED FIBERGLASS PIPE INSULATION W/ FACTORY JACKET. HORIZONTAL STORM DRAIN PIPING - 1 1/2" THICK PREFORMED FIBERGLASS PIPE INSULATION W/ FACTORY JACKET. CONDENSATE PIPING - 3/4" ARMAFLEX PREFORMED. EXHAUST PIPE - 3" THICK CALCIUM SILICATE BLOCK INSULATION W/1200 F. STEVENS CLASS CLOTH WRAP. 29. PROVIDE 1/2" TRAP PRIMER LINE FOR ALL FLOOR DRAINS FROM THE NEAREST PLUMBING FIXTURE. 30. NO WATER, SANITARY OR DRAINAGE PIPING PERMITTED IN ELECTRICAL OR ELEVATOR EQUIPMENT ROOMS.; WATER STUBBED THRU FOR ELECTRICAL GROUND AND SPRINKLER HEAD AND PIPE W /CONTROL VALVE AS APPROVED BY LOCAL BUILDING AND FIRE DEPARTMENTS. 31. ALL HOSE BIBBS SHALL BE CHROME PLATED 3/4- SOLID FLANGE THREADED HOSE AND LOOSE KEY W/VACUUM BREAKER - WATTS 8A, MOUNTED 26" ABOVE GRADE WALL HYDRANTS TO BE ZURN Z- 1350 -5 OR FINISH FLOOR UNLESS OTHERWISE NOTED. 32. INTERIOR FLOOR CLEANOUTS SHALL BE ZURN ZN1400. 33. ALL CONTROL VALVES SHALL BE TAGGED AND MARKED. A REPRODUCEABLE DIAGRAM LOCATING ALL VALVES SHALL BE PROVIDED FOR OWNER /OPERATOR. 34. SCHEDULE 40 PVC D.W.V. MAY BE USED ON SANITARY, STORMDRAINS, AND CONDENSATE LINES WHERE LOCAL CODE AND ORDINANCES WILL ALLOW. 35. ALL METALLIC PIPING. FITTINGS AND HANGERS EXPOSED TO CORROSIVE CONDITIONS SHALL HAVE A PROTECTIVE COATING THAT RESIST CORROSION. 36. ALL FIRE MAINS, HOT & COLD WATER PIPES, HOT WATER RETURN PIPING, STORM DRAIN AND CONDENSATE PIPING AND GAS PIPING SHALL HAVE IDENTIFICATION AND FLOW DIRECTIONS BANDS. 37. CONTRACTOR SHALL KEEP A SET OF AS BUILTS DWG. ON THE JOB SITE AT ALL TIMES AND DELIVER A SET OF UP TO DATE AS- BUILTS TO THE ENGINEER AND OWNER AT THE COMPLETION OF THE PROJECT. I REVISIONS No. I 20100 n.e. 21 avenue no. miami beach, 1 33179 i 0 N PLUMBING SYMBOLS ° & ABBREVIATIONS . _ li 5- - --� HOT WATER PIPE HW i --- --i COLD WATER PIPE CW f- - -� HOT WATER RECIRCULAING HWR Q WATER HAMMER ARRESTOR WHA n AIR CHAMBER � - S-�-S CHECK VALVE CV 9 + S HOSE BIBB W/ VACUUM BREAKER & HB v SHUT -OFF VALVE GATE VALVE (SHUT -OFF VALVE) SOV §.-SAN----4 SANITARY LINE SAN F --CD -S CONDENSATE LINE CD 5-- - - - - -i VENT LINE j--PLT -1 PRESSURE RELIEF P &T S-DP -S DRAIN PAN DP 1-- ESAN --4 EXISTING SANITARY LINE ESAN S- -ECW - -4 EXISTING COLD WATER PIPE ECW WATER CLOSET WC VENT THRU ROOF VTR , • LAVATORY LAV JANITOR'S SINK JS FLOOR DRAIN FD . 1� ELECTRIC WATER COOLER EWC ABOVE FINISH FLOOR A.F.F. BELOW FINISH FLOOR B.F.F. FLOOR CLEANOUT FCO O C CLEANOUT TO GRADE CTG ip� WALL CLEANOUT WCO FIXTURE UNITS FU U EXISTING FLOOR CLEAN OUT EFCO CONNECT NEW PIPE INTO EXISTING 10 cc NOTE; NOT ALL SYMBOLS & ABBREVIATIONS APPLY TO THIS JOB, I REVISIONS No. I 20100 n.e. 21 avenue no. miami beach, 1 33179 i 0 N V ° L0 . _ li N V ° L0 . _ li C y I a -}- ° rn V ° u7 � - • _ C- v m v 0 U a of 13039 c � t, RAJI QD , • I • 4J • �la . 1� j • no r,k ii O C w ip� O • .1 ` Y Yid •' ' %%.,p ' N t p • ,s 1 P -3 OF 3 SHEETS l•I Y I ,II a t, • no r,k ii O C w ip� O co r4 t • U O cc S< Cc cc v� W in LL 'O^ UL 0 O JO L Z W. • 0 ,� r• R'.' lu W o .• DO NOT SCAll ` • DRAWN G.B' „k� CHECKED •• R.P. s �. a DATE 11-30-05 DO NOT SCALE SCALE AS NOTED JOB NO. •, 0423 " SHEET I '� P -3 OF 3 SHEETS l•I Y I ,II