06-782R-016PATE STAINLESS ADJUSTABLE CLAMP. PATE SPUN ALUMINUM BASE. PATE STEPPED PVC BOOT STRIPING _.... ....... ...... . MASTIC MEMBRANE CONCRETE DECK DECK PIPE SEAL DETAIL N.T.S. SPRING & NEOPRENE TYPE VIBRATION ISOLATORS TYP. 3/8" HANGING RODS (THREADED) COORDINATE W/ STRUCTURAL ENGINEER AND /OR ARCH. ON HOW TO FASTEN TO STRUCTURE MOUNTING CLIPS OR UNITS CONNECTION TO SUPPORT RODS AS RECOMMENDED BY MFG. ELECTRIC HEAT ASSEMBLY FLEXIBLE DUCT CONNECTOR SUPPLY AIR DUCT SMOKE DETECTOR IN SUPPLY AIR DUCT AS REQUIRED TRANSITION AS REQUIRED PROVIDE 24" SERVICE CLEARANCE FOR ALL ACCESS PANELS TRANSITION AS REQ'D. RETURN AIR DUCTWORK OUTSIDE AIR DUCT W/ OPPOSED BLADE DAMPER F� (TYPICAL) FILTER & RACK ASSEMBLY 1" GALV. DRAIN PAN STRAPPED TO A.H.U. INSULATED CONDENSATE DRAIN AND TRAP (SEE PLUMB. FOR CONTINUATION) �— REFRIGERANT LINES TO CONDENSING UNITS ::> INSULATE SUCTION LINE) AUX. DRAIN (SEE PLUMB. FON CONTINUATION) AIR HANDLING UNIT A.H.U. HANGING DETAIL N.T.S. CONC. SLAB LIQUID REFRIGERANT LINE PROVIDE WATERTI( DECK PENETRATIO PATE PVC. BOOT ALUM. BASE. SEE PIPE SEAL DETAIL 20 GAUGE SHEET -METAL (SIZE AS REO'D)— FLASHING AS RECOM. BY MANUF. SLEEVE LL SLEEVE WITH FIRE - PROOF/ RE RESISTANT LICON SEALANT FOAM fC. PR -855 25/50 RATED INSUJLATION SUCTION LINE .. .• 1 I III F• .• M SLAB SEE ENLARGED DETAIL THIS DWG. REFRIGERANT PIPE RAINCOVER DETAIL N.T.S. REFRIGERANT LINES FROM ACCU'S CONDENSING UNIT 2 "X2 "X1/4" THICK NEOPRENE VIBRATION ISOLATORS (TYP. AT EA. CORNER) ANCHOR C.U. TO THE CONC. SLAB USING 2 "X 18 GAUGE GALV. STRAPS FASTENED W/ 3/8" DIAM.X 3 "L. EXPANSION ANCHOR BOLTS W/ WASHERS (TYP. AT EA. CORNER) EXISTING CONCRETE HOUSE- KEEPING PAD EXISTING CONCRETE DECK C.U. MOUNTING DETAIL N.T.S. �• a •' FLAT BAR ROD CONCRETE INSERTS FOR DUCTS UP TO 18' FOR DUCTS UP TO 36' MAXIMUM DIMENSION MAXIMUM DIMENSION DRIVE PIN THREADED STUD POWDER ACTUATED FASTENERS DUCT SUPPORT SYSTEM FOR ALL EXPOSED DUCT O ■ IiY• a i\ MANUFACTURED CONCRETE INSERT IS HANGER HANGER STRA ROD POWER ACTUATED STUDS INTO STEEL (STRUCTURE OR DECK) le HANGER HANGER STRA ROD WELDED STUDS INTO STEEL (STRUCTURE OR DECK) STRAP FOR DUCTS U FRICTION LAMPS TO IS' MAX. STRAP DIMENSION WASHER EXPANSION SHIELDS EXPANSION NAIL 7WASHER NUT CONCRETE ANCHORS NOTE CONSTRUCTION AND INSTALLATION SHALL BE AS PER SMACNA STANDARD FOR TYPE OF DUCTWORK INSTALLED IN FACILITY. UPPER ATTACHMENT METHODS OF HANGING DUCTS AND EQUIPMENT DETAIL N.T.5. LOW VELOCITY SUPPLY OR RETURN AIR DUCT SPIN -IN COLLAR WITH VOLUME DAMPER OPERATOR TO BE OUTSIDE THE INSULATIDN. PROVIDE INSULATI ❑N GUARD WHERE NECESSARY (DAMPER WHERE NOTED). (PROVIDE DUCT DAMPERS WHERE ACCESSIBLE) it %; INSULATED FLEX DUCT SEAL JOINT WITH DUCT SEALER INSULATE OR LINE SURFACES TO PREVENT CONDENSATION. �— CEILING DIFFUSER OR RETURN REGISTER. FLEXIBLE DUCT CONNECTION DETAIL N.T.S. 1J2" HANGER ROD (4 REQ'D.) FASTENED TO CONCRETE STRUCTURE ABOVE WITH EXPANSION BOLTS. HIL71 KWIK BOLT EEXP. ANCHOR. ROD COUPLING TYPE 2 1/4" EMBEDMENT. 'ORT CROSS .E (IF REQUIRED) ueurca Rnn SPRING ISOLATOR E FAN BOTTOM HUNG HANGER ROD A.H.U. OR INLINE FAN BEYOND INLINE FAN OR A/C UNIT MOUNTING DETAIL N.T.S. ALL DAMPERS SHALL COMPLY WITH NFPA 90A UL 555 LISS Q% V o N 0 DUCT ' In a2O y I 04 fl. -/ — ACCESS DOOR 2 U ° O INSULATION WHERE DUCTS O U') -C 3 ARE SO SPECIFIED a m a �P OOM) T IN O EQUIPMENT (IF VIm >O LL v (%� a Ld �E �o azo 0 OS NOT USED. 12 Of 13039 c 6 w O6 1/8' CLEARANCE PER 12' OF Q (J DUCT ON ALL FOUR SIDES r 7O COLLAR (SEE NOTES) 10 9 130 1" TYP. ALL FOUR SIDES O9 1- 1/2'x1 -1 /20x10 GA. OR HORIZONTAL MOUNTING DETAIL HEAVIER ANGLES SNUG TO FLOOR & COLLAR ALL AROUND CLOSER 10 'S' SUP 6 11 8 ANGLE AS REQ'D 11 WALL 7 BY BLDG. LOCAL 12 FLOOR SLAB DEPT. NOTES: 1. COLLAR GAUGES: 1 2 A. FOR COLLARS NOT EXCEEDING 36'W OR 24 "H — 16 GAUGE 3 B. FOR COLLARS EXCEEDING 36'W OR 24'H — 14 GAUGE 10 2. ATTACH ANGLES TO COLLARS OR ( 110 TEC SCREWS) WITH 1/4" 20 BOLTS & 9 NUTS 12" C —C MAX. MIN. 2 BOLTS IN EACH SIDE TOP & BOTTOM 3. INSTALLATION SHALL CONFORM VERTICAL MOUNTING DETAIL TO NFPA -90A 4. PROVIDE ACCESS DOORS TO SERVICE FUSIBLE LINKS AS REQUIRED NOTE: TYPE "B' IS DETAILED FOR ALL SUPPLY AIR DUCTS TYPE "A" MAY BE USED FOR ALL RETURN ARE DUCTS AS REQUIRED. ALL MOTORIZED FIRE SMOKE DAMPERS SHALL BE FSD -60 TYPE. TYPICAL STYLE "B" FIRE DAMPER DETAIL N.T. . RJ V_ jONS No. OWNER RECID. REV. (im- 2l -ob) 1 20100 M.S. 21 avenue no. miami beach, 11 33179 °C �T t• LISS Q% V o N V In cc y I 04 fl. -/ — ° rn U ° O U') -C ' 4m —C— m M a �P VIm >O LL v (%� a Ld �E �o azo 0 Of 13039 c °C �T t• DRAWN M.R. CHECKED R.P. DATE 11 -30 -05 SCALE AS NOTED JOB NO. 0423 SHEET M -5 OF G SHEETS f DO NOT SCALE ■ Q cc J O W a �P VIm >O LL ■ (%� O Ld �E �o azo 0 — a V) Q Jo LL- r W (0 DRAWN M.R. CHECKED R.P. DATE 11 -30 -05 SCALE AS NOTED JOB NO. 0423 SHEET M -5 OF G SHEETS f DO NOT SCALE