06-782R-010
EXIST. EQUIPMENT & WIRING SCHEDULE O7 8 SETS OF [4- 500MCM -4 "C.] PLUS (2) SPARE 4 "C. O2 4 -600 MCM -4 "C. Q3 2 [4- 60OMCM & 1 #1 10(G) - 3- 112 "C.3 ® LINE GUTTER: 12" x 12 "x 60" (MIN.), WITH (2) 600 MCM PER PHASE AND NEUTRAL RUN ACROSS ENTIRE LENGTH. PROVIDE POLARIS OR EQUAL PRE - FORMED TAP KIT W/ MIN. OF (1) #4- 500MCM SPARE TAP. 05 4- 350MCM & 1 #1 /0(N) - 3 "C. © 400A.- 3PH -4W ELECTRIC METER Q7 3P -400A. (L- FRAME) MAGNETIC -ONLY CIRCUIT BREAKER WITH SOLID NEUTRAL IN NEMA 1 /U.L.S.E. ENCLOSURE. ® FIRE PUMP CONTROLLER (WYE- DELTA). REFER TO FP -DWGS. 90 4- 350MCM & 1 #3 (G) - 3 "C. 10 4 -500 MCM & 1 #3(G) -3 "C. 11 4 # 4/0 & 1 #3 (G)- 2- 1/2 "C. 1® 4 # 6 & 1 #8(G) - 1-1/4"C. 4 # 1/0 & 1 #6 (G)- 2 "C. 14 ELEVATOR MACHINE FUSED DISCONNECT SWITCH 3P- 200A. -25OV. W /150A. RK5 FUSES. NEMA 1 ENCLOSURE. 15 3 #1/0 & 1 #6(G)- 2 "C. TO ELEVATOR MACHINE (25 HP). C PHOTOCELL. INTERMATIC # K4236M. 17 8P -30A. MECHANICALLY -HELD LIGHTING CONTACTOR IN NEMA 1 ENCLOSURE W /120V. COIL, 2 -WIRE CONTROL RELAY AND H -O -A SWITCH ON COVER. 18 3 #14- 3/4 "C 19 1P- 20A.- 120/277V., 24 -HOUR ELECTRONIC TIME SWITCH WITH BATTERY CARRYOVER. INTERMATIC MODEL No. ET102C. 20 3P -225A FRAME -200A TRIP C.B.- 65,000 AIC WITH SOLID NEUTRAL IN NEMA 1 /U.L.S.E. ENCLOSURE. 21 PANELBOARD. REFER TO PANEL SCHEDULES. 2© SERVICE GROUND TO FOOTING REBARS, TO 5/8"0 x 10' -0" COPPERCLAD DRIVEN GROUND ROD & TO COLD WATER PIPE. 2© LINE GUTTER: 10" x 10 "x 48" (MIN.), WITH (1) 600 MCM PER PHASE AND NEUTRAL RUN ACROSS ENTIRE LENGTH. PROVIDE POLARIS OR EQUAL PRE - FORMED TAP KIT W/ MIN. OF (1) #4- 50OMCM SPARE TAP. TYPE: SIEMENS MAIN BUS: 225 AMP SERVICE: 120/208V, 30,4W PANEL 73' NEUTRAL: FULL MOUNTING: SURFACE MAINS: M.L.O. POLES: 42 A.I.C. 1OK SERIES DEM. WA NO DEM kVA TRIP/ POLE CONDUIT WIRE REMARKS CKT. NO. CKT. NO. REMARKS WIRE CONDUIT TRIP/ POLE NO DEM kVA DEM. kVA 200 AMP 1.0 20 -1 1/2 12 RECEPTACLES 1 12 OFFICE LIGHTING 10 1/2 20 -1 1.6 PANEL 'T4' /'G' POLES: 0.8 20 -1 1/2 12 RECEPTACLES 3 14 OFFICE LIGHTING 10 1/2 20 -1 1.2 MICROWAVE 10 0.8 20 -1 20 -1 1.5 SPARE 5 6 OFFICE LIGHTING 10 1/2 20 -1 1.2 6 COMPUTER OUTLETS 1.2 20 -1 1/2 12 RECEPTACLES 7 8 RECEPTACLES 12 1/2 1 20 -1 1.0 7 8 1.0 20 -1 1/2 12 RECEPTACLES 9 10 RECEPTACLES 12 1/2 20 -1 1.0 O.R. RM. LTG. 9 1.0 20 -1 1/2 12 RECEPTACLES 11 12 RECEPTACLES 12 1/2 20 -1 1.0 12 LIGHTING 1.0 20 -1 1/2 12 RECEPTACLES 13 14 RECEPTACLES 12 1/2 20 -1 1.5 1/2 12 1.2 20 -1 1/2 12 1 RECEPTACLES 15 16 RECEPTACLES 12 1/2 20 -1 1.2 20 -1 1 2 0.8 20 -1 1/2 12 RECEPTACLES 17 18 1/2 30 -2 2.5 20 -1 1.5 1.0 20 -1 1.0 20 -1 1/2 12 RECEPTACLES 19 20 1 ACCU -103 8 3/4 50 -3 0.8 1.0 8.4 50 -2 3/4 8 AHU -103 21 22 TOTAL CONNECTED LOAD = 6.8 KVA 33 AMP) 12 1/2 15 -1 0.4 6.8 60 -2 2 A 23 24 TANKLESS W.H. 8 3/4 50 -2 9 4.6 10.7 70 -2 1 1/4 4 AHU -104 25 26 24 10 1/2 20 -1 1.0 18.3 Q NON CON CONNECTED LOAD = 28.1 KVA PLUS 25% CONTINUEOUS LOAD = 1.3 KVA TOTAL CONNECTED LOAD = 29.4 KVA (82 AMP) CURRENT LOAD; LOCATED O SECOND PARKING LEVEL SPARE 27 28 EF -3 & 8 12 1/2 20 -1 0.5 9 50 -2 3/4 8 TANKLESS W.H. 29 30 SPACE 20 -1 1.0 SPACE 31 32 ACCU -104 8 3/4 50 -3 1.0 1.0 20 -1 3/4 10 SPARE 33 34 SPACE 20 -1 1.0 1.0 20 -1 SPARE 35 36 OFFICE LIGHTING 10 1/2 20 -1 1.3 SPACE 37 38 OFFICE LIGHTING 10 1/2 20 -1 1.3 29.4 100 -3 1 1 4 3 SPACE 139, 40 OFFICE LIGHTING 10 1/2 1 20 -1 1.2 SPACE 1411142 421 OFFICE LIGHTING 10 1 /Tj 20 -1 1.2 31.9 19.7 TOTAL CONNECTED LOAD = 52.0 KVA = 144 AMPS Q NON CON CURRENT LOAD; LOCATED ON SECOND PARKING LEVEL W.P. ENCLOSURE UNIT MOUNTED 100 AMP M.C.B. KOHLER MODEL FIRE PUMP -' 75HP- 208V. -30 1 ST FLOOR EXIST. WIREWAY #1 SUMMARY SIEMENS 120/208V, 30,4W PANEL SURFACE 24 SERVICE: 120/208V, 30,4W MAIN BUS: NEUTRAL: MAINS: A.I.C. TENANTS DEM. kVA KVA AMP CONDUIT OVER CURRENT PROTECTION FUTURE PANEL'T1' CKT. No. 36.8 102 WIRE 200 AMP FUTURE PANEL'T2' NO DEM kVA 37.1 103 0.4 200 AMP PANEL'T3' 12 52.0 144 12 200 AMP PANEL 'T4' /'G' POLES: 139.6 388 1.2 400 AMP 1ST FLR. WIREWAY #1 0.8 20 -1 1/2 12 PRE OP AREA & ALARM 1, TOTAL CONNECTED LOAD 265.5 737 MICROWAVE TYPE: SERVICE: MOUNTING: POLES: SIEMENS 120/208V, 30,4W PANEL SURFACE 24 'G' MAIN BUS: NEUTRAL: MAINS: A.I.C. 400 AMP FULL 3P 300 A MCB 10K SERIES DEM. kVA NO DEM kVA TRIP / POLE TRIP/ CONDUIT WIRE REMARKS CKT. No. CKT. No. REMARKS WIRE CONDUIT TRIP/ NO DEM kVA DEM. kVA AMP 0.4 20 -1 1/2 12 SERVER 1 1 12 REFRIGERATOR 10 POLES: 1/2 20 -1 1.2 1 1ST FLR. WIREWAY #1 0.8 20 -1 1/2 12 PRE OP AREA & ALARM 1, 3 4 MICROWAVE 10 CKT. NO. 1/2 20 -1 1.5 CONDUIT TRIP/ 0.4 20 -1 1/2 12 O.R. RM. WORK ST. & FAUCETS I 5 6 COMPUTER OUTLETS 10 800 1/2 20 -1 0,6 4 EXST. 4TH FLR. TENANTS 0.7 20 -1 1/2 12 OVERNIGHT STAY BED 7 8 COMPUTER OUTLETS 10 O.R. EQUIP 1/2 20 -1 0,6 0.4 1 ACCU -106A 1.8 20 -1 1 72 12 O.R. RM. LTG. 9 10 COMPUTER OUTLETS 10 12 1/2 20 -1 0,6 2❑ INCLUDES TENANTS 1 & 2 ( 73.9 KVA ) 1.8 20 -1 1/2 12 LIGHTING 11 12 COMPUTER OUTLETS 10 1/2 1 2 20 -1 0 6 12 0.7 1.8 20 -1 1/2 12 LIGHTING 13 1 12 1/2 20 -1 0.7 AUTOCLAVE 4 1.0 20 -1 1.8 20 -1 1 2 2 IG TI G 15 1 MEDICAL VACUUM SYSTEM 10 1.0 1/2 30 -2 2.5 20 -1 1.5 1.0 20 -1 11 1 E- 'ALARM SST 17 t 19 20 AUTOCLAVE CONTROL 3.4 1/2 15 -1 0.8 1.0 20-1 1 2 12 GAS MANIFOLDS 19 20 122. TOTAL CONNECTED LOAD = 6.8 KVA 33 AMP) 12 1/2 15 -1 0.4 6.8 60 -2 2 A 21 22 PANEL'G2' 6 1/2 1 60 -2 4.6 2.0 30 -2 1/2 10 OR ROOM LASER r 25 23 24 10 1/2 20 -1 1.0 18.3 Q NON CON CONNECTED LOAD = 28.1 KVA PLUS 25% CONTINUEOUS LOAD = 1.3 KVA TOTAL CONNECTED LOAD = 29.4 KVA (82 AMP) CURRENT LOAD; LOCATED O SECOND PARKING LEVEL SPARE 27 9.8 TYPE: GE DEM. kVA LINE ISOLATION PANEL 'G2' LINE ISOLATION DEM. kVA MAINS: 3P 60 A MCB SERVICE IN: 120/208V, 10, 3W PANEL 'G1' REMARKS MOUNTING: FLOOR CKT. No. CKr. No. SERVICE OUT: 120/208V, 10, 3W MLO TRIP/ POLE NO DEM kVA DEM. kVA AMP 0.6 20 -1 1/2 12 WITH BUILT IN ISOLATION TRANSFORMER (10 KVA) 1 2 O.R. LIGHT POLES: 12 20 -1 0.4 1 1ST FLR. WIREWAY #1 0.4 20 -1 1/2 DEM. NO DEM TRIP/ TRIP/ CONDUIT WIRE REMARKS CKT. NO. CXT. No. REMARKS WIRE CONDUIT TRIP/ NO DEM. kVA DEM. kVA WA kVA POLE 220 5 6 1 SPARE 800 800 20 -1 0.6 4 EXST. 4TH FLR. TENANTS 0.4 20 -1 0.4 20 -1 1/2 12 O.R. EQUIP 1 2 O.R. EQUIP 12 1/2 20 -1 0.4 1 ACCU -106A 1.0 0.8 20 -1 1/2 12 O.R. EQUIP n 3 4 O.R. EQUIP 12 1/2 20 -1 0.8 2❑ INCLUDES TENANTS 1 & 2 ( 73.9 KVA ) 0.5 20 -1 1 1/2 12 1 O.R. EQUIP 5 6 O.R. EQUIP 12 1/2 20 -1 0.5 APPLIANCES 12 0.7 20 -1 1/2 12 O.R. EQUIP & ELEC. DOORS V 8 O.R. EQUIP 12 1/2 20 -1 0.7 AUTOCLAVE 4 1.0 20 -1 22.5 SPARE 9 101 SPARE 12 IL 20 -1 1.0 KITCHEN RECEPTS. 12 1/2 20 -1 1.5 SPACE 11 1 121 SPACE 12 RECEPTACLES 19 20 AUTOCLAVE CONTROL 3.4 1/2 15 -1 0.8 9.0 40 -3 3.4 8 AHU -106 HEATETR 1 21 122. TOTAL CONNECTED LOAD = 6.8 KVA 33 AMP) 12 1/2 15 -1 0.4 TYPE: GE SERVICE IN: 120/208V, 10, 3W SERVICE OUT: 120/208V, 10, 3W POLES: 12 DEM. kVA LINE ISOLATION PANEL 'G2' MAINS: 3P60AMCB DEM. kVA NO DEM kVA TRIP/ POLE ONDU WIRE REMARKS MOUNTING: FLOOR CKT. No. CKr. No. REMARKS WIRE lCONDUI MLO TRIP/ POLE NO DEM kVA DEM. kVA AMP 0.6 20 -1 1/2 12 RECOVERY ROOM EQUIP 1 2 O.R. LIGHT 12 1/2 20 -1 0.4 1 1ST FLR. WIREWAY #1 0.4 20 -1 1/2 12 RECOVERY ROOM BED 3 4 O.R. EQUIP 12 1/2 20 -1 0.8 RECEPTACLES 800 0.4 20 -1 1/2 12 O.R. EQUIP 220 5 6 1 SPARE 800 800 20 -1 0.6 4 EXST. 4TH FLR. TENANTS 0.4 20 -1 1/2 12 O.R. EQUIP 800 7 8 SPACE SPACE 12 RECEPTACLES 9 10 1 ACCU -106A 1.0 20 -1 30 -2 TOTAL CONNECTED LOAD SPARE 2570 9 101 SPACE Q EXISTING BREAKER AND FEEDER TO REMAIN. 11 12 2❑ INCLUDES TENANTS 1 & 2 ( 73.9 KVA ) SPACE 1.0 11 121 SPACE RECEPTACLES 13 14 APPLIANCES 12 2.8 20 -1 1.5 TOTAL CONNECTED LOAD = 4.6 KVA (22 AMP) 11 1.8 TYPE: EXST.SIEMENS'SB2' DEM. kVA NO DEM kVA TRIP/ POLE EXISTING MAIN BUS: 3000A CU. SERVICE: 120/208V, 30,4W REMARKS CKT. NO. CKT. NO. PANEL'HDA' A.I.C: EXISTING MOUNTING: FLOOR CONDUIT TRIP/ NO DEM. kVA MAINS: MLO CKT. NAMEPLATE KVA AMP AHU -105 PROTECTION WIRE AND CONDUIT REMARKS _ POLES SWITCH FUSE NO. DESIGNATION 1.0 20 -1 1/2 1 1ST FLR. WIREWAY #1 265.5 737 3 8 800 800 2 SETS OF 4 #600 & #1/0(G); 3 1/2 "C L 1 2 EXST. 2ND FLR. TENANTS 220 611 3 RECEPTACLES 800 800 2 SETS OF 4 #600 & #1 /0(G); 3 1 /2 "C a 3 EXST. 3RD FLR. TENANTS 220 611 3 1 4.0 800 800 2 SETS OF 4 #600 & #1 /0(G); 3 1/2 "C 0 4 EXST. 4TH FLR. TENANTS 220 611 3 800 800 2 SETS OF 4 #600 & #1 /0(G); 3 1 /2 "C a 5 SPACE 12 RECEPTACLES 9 10 1 ACCU -106A 10 3/4 30 -2 TOTAL CONNECTED LOAD 925.5 2570 9 50 -2 3/4 Q EXISTING BREAKER AND FEEDER TO REMAIN. 11 12 2❑ INCLUDES TENANTS 1 & 2 ( 73.9 KVA ) % -Y -WV V -V V V" v V v TYPE: SIEMENS MAIN BUS: 400 AMP SERVICE: 120/208V, 30,4W PANEL 74A' NEUTRAL: FULL MOUNTING: SURFACE MAINS: MLO POLES: 42 (SECTION 2 OF 2) A.I.C. 10K SERIES DEM. kVA NO DEM kVA TRIP/ POLE CONDUIT WIRE REMARKS CKT. NO. CKT. NO. REMARKS WIRE CONDUIT TRIP/ NO DEM. kVA DEM. kVA ul 8.4 50 -2 3/4 8 AHU -105 1 2 OFFICE LIGHTING 10 __374 20 -1 1.4 > o 1.0 20 -1 1/2 12 RECEPTACLES 3 4 ACCU -105 8 1/2 50 -3 1.2 L 1 1.0 20 -1 1/2 12 RECEPTACLES 5 6 W/D STACK 10 1/2 30 -2 5.0 Zc-) 2 1 4.0 25 -3 3/4 10 1 AHU -106 1 1 7 8 SPACE 1.0 20 -1 1/2 12 RECEPTACLES 9 10 1 ACCU -106A 10 3/4 30 -2 3.0 9 50 -2 3/4 8 TANKLESS W.H. 11 12 1.0 20 -1 1/2 12 RECEPTACLES 13 14 APPLIANCES 12 1/2 20 -1 1.5 11 60 -2 1 6 TANKLESS W.H. 15 16 AUTOCLAVE 4 1 1/4 80 -3 22.5 0.8 20 -1 1/2 12 IL 17 18 KITCHEN RECEPTS. 12 1/2 20 -1 1.5 0.8 20 -1 1/2 12 RECEPTACLES 19 20 AUTOCLAVE CONTROL 12 1/2 15 -1 0.8 9.0 40 -3 3/4 8 AHU -106 HEATETR 1 21 122. STERILIZER 12 1/2 15 -1 0.4 0.4 20 -1 2 LIGHTING & EF -9 23 24 OFFICE LIGHTING 10 1/2 20 -1 1.4 2.0 30 -2 1/2 10 OR ROOM LASER r 25 26 SPARE 10 1/2 20 -1 1.0 20 -1 SPARE 27 28 SPARE 20 -1 1,0 30 -2 1/2 10 IFUTURE OR ROOM LASERr 29 30 SPACE 20 -1 1.0 SPACE 31 32 SPACE 20 -1 1.0 3.0 30 -2 3/4 10 ACCU -1068 33 134, SPACE 20 -1 1.0 j)331 35 1361 SPACE 37 381 SPACE 29.4 100 -3 1 1 4 3 SPACE 39 40 SPACE SPACE 41 421 SPACE 42.4 28.7 CONNECTED LOAD = 71.1 KVA SEE SECTION 1 FOR TOTAL CONNECTED LOAD Q NON CON CURRENT LOAD; LOCATED 0 SECOND PARKING LEVEL TYPE: SIEMENS MAIN BUS: 400 AMP SERVICE: 120/208V, 30,4W PANEL 74' NEUTRAL: FULL MOUNTING: SURFACE MAINS: M.L.O. POLES: 42 (SECTION 1 OF 2 WITH FEED THRU LUGS) A.I.C. 10K SERIES DEM. kVA NO DEM kVA TRIP/ POLE CONDUIT WIRE REMARKS CKT. No. CKT No. REMARKS WIRE CONDUI TRIP/ POLE NO DEM kVA DEM. kVA ul 0.8 20 -1 1/2 12 RECEPTACLES 1 12 OFFICE LIGHTING 10 1/2 20 -1 1.4 > o 1.0 20 -1 1/2 12 RECEPTACLES 3 14 OFFICE LIGHTING 10 1/2 20 -1 1.2 -a 1.0 20 -1 1/2 12 RECEPTACLES 5 16 W/D STACK 10 1/2 30 -2 5.0 Zc-) 'ru-) 1.0 20 -1 1/2 12 1 RECEPTACLES 7 8 1.0 20 -1 1/2 12 RECEPTACLES 9 10 W/D STACK 10 1/2 30 -2 5.0 1.0 20 -1 1/2 12 RECEPTACLES 11 12 1.0 20 -1 1/2 12 RECEPTACLES 13 14 APPLIANCES 12 1/2 20 -1 1.5 0.8 20 -1 1/2 12 RECEPTACLES 15 16 KITCHEN RECEPTS. 12 1 2 20 -1 1.5 0.8 20 -1 1/2 12 RECEPTACLES 17 1 18 KITCHEN RECEPTS. 12 1/2 20 -1 1.5 0.8 20 -1 1/2 12 RECEPTACLES 19 1201 EF 4 & 5 12 1/2 20 -1 0.7 1.4 20 -1 1/2 12 OFFICE LIGHTING 21 1221 OFFICE LIGHTING 10 1/2 20 -1 1.4 0.4 20 -1 2 LIGHTING & EF -9 23 1241 OFFICE LIGHTING 10 1/2 20 -1 1.4 -1 -Al S R 25 26 EWH 10 1/2 30 -2 4.5 20 -1 SPARE 27 28 SPACE 29 30 SPARE 20 -1 1.0 SPACE 31 32 SPARE 20 -1 1.0 SPACE 33 34 SPARE 20 -1 1.0 SPACE 35 36 SPACE 37 38 SPACE 29.4 100 -3 1 1 4 3 PANEL'G' VIA ATS 439 40 SPACE 41 42 SPACE 40.4 SECTION 1 CONNECTED LOAD = 68.5 KVA 28'1 SECTION 2 CONNECTED LOAD = 71.1 KVA 2 SECTION TOTAL CONNECTED LOAD = 139.6 KVA (388 AMPS) U L_ - - - -� L- - - - - --I L- }-- - - - - -1 - - - - - -- ------- I - - - --� O � I - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -� ELECTRICAL RISER DIAGRAM 19110 1 !� tVlSIONS No. 04:'ER REVD. -REV. Q OWNER REOV. REV. Q CIO- Z3 -06) 20too n.e. 21 avenue no. miami beach, 11 33179 N U `O ul /� CL U o N O _ °� t o rn U o z� ul 4) c- Q 0 r L � m v Q w � a or 13039 c DRAWN A. H. CHECKED R.P. DATE 11-30-0 SCALE AS NOTED JOB NO. 0423 SHEET E -4 OF 4 SHEETS DO NOT SCALE ■ Q Q n° 14 __1 W O 6 -0 C 1 LL ON z� DRAWN A. H. CHECKED R.P. DATE 11-30-0 SCALE AS NOTED JOB NO. 0423 SHEET E -4 OF 4 SHEETS DO NOT SCALE ■ Q Q n° ■ W O 6 -0 C 1 LL ON �� IL O Q W Q w � C� m > o IL LL ° cn 00 O mi aCC � Zo -a w 0 0 I pW -1- ♦. 2W Zc-) 'ru-) DRAWN A. H. CHECKED R.P. DATE 11-30-0 SCALE AS NOTED JOB NO. 0423 SHEET E -4 OF 4 SHEETS DO NOT SCALE