Loading...
06-781-004ELEC. OUTLET 1 OR 2 HOUR RATED GYPSUM WALLBOARD ASSEMBLY 0!-Is i fl. 9L T-liOR CONDUIT (EMT) ROMEX (WIRE) `rYsteo f STUD /FURRING — /CONDUIT (EXT.) I — J 3M FIRE BARRIER MOLDABLE PUTTY CALL AROUND) FRONT VIEW STUD /F 3M FIRE BARRIEI MOLDABLE PUTT) (ALL AROUND) SIDE VIEW WALL OPENING PROTECTIVE MATERIALS (CLIV) UIT (E.M.T.) 2 HOUR FIRE D ASSEMBLY This category covers proprietary compositions which are used to maintain the hourly ratings of fire resistive walls and partitions containing flush mounted devices such as outlet boxes, electrical cabinets and mechanical cabinets. The individual Classifications indicate the specific applications and the method of installation for which the materials have been evaluated. The basic standard used to Investigate products in this category is ANSI /UL 263. 'Fire Tests of Building Construction and Materials'. MINNES ❑TA MINING & MFG CO. 3M CENTER, ST PAUL MN 55144 Type MPP -45+ moldable putty pads for use with max 4 11/16 by 4 11/16 in. flush device UL Listed Metallic Outlet Boxes in fire rated gypsum wallboard wall assemblies framed with min 3 -1/2 in, wide wood or steel studs and constructed as specified in the individual U300 or U400 Series Wall and Partition Designs in the Fire Resistance Directory. Type MPP -45+ moldable putty pads for use with max 4 by 3 -3/4 by 3 In. deep UL Listed Nonmetallic Outlet Boxes manufactured by Carton, made of PVC and bearing a 2 hr rating under the Outlet Boxes and Fittings Classified for Fire Resistance category In the Fire Resistance Directory. For use in fire rated gypsum wallboard wall assemblies framed with min 3 -5/8 In. wide wood studs and constructed as specified In the individual U300 Series Watt Partition Desings in the Fire Resistance Directory, Moldable putty pads are to be Installed to completely cover the exterior surfaces of the box within the stud cavity with a ball of the putty material used to plug the end of each electrical metallic tube or conduit at Its connection to the box. A min 1/8 In. thickness of putty material Is required on the exterior surfaces of flush device boxes in 1 and 2 hr fire rated Wall and Partition Desing. When the moldable putty pad outlet box protective material is used as directed, the horizontal separation between outlet boxes on opposite sides of the wall may be Less than 24 in. provided that the outlet boxes are not installed back to back. U� `rYster` CAJ 1302 F- Rating = 2 Hr. VNUMO 3735 Green Rd. Beachwood, OH, 44122 Drawing not to scale lO Pre -Rated Concrete Floors or Block Walls = Min. 4 -1/2' thickness. O Metallic Pipe: A) Steel Pipe - 8' dian. (or smaller) Sch. 10 (or heavier) steel pipe. B) Iron Pipe - 8' diam. (or smaller) cast or ductile iron pipe. C) Conduit - 4' diam, (or smaller) EMT or steel conduit. D) Copper Tubing - 4' diam. (or smaller) Type L (or heavier) copper tubing. E) Copper Pipe - 4' dian. (or smaller) Regular (or heavier) copper pipe. OPacking Material- See table below for mineral wool insulation (min. 4.0 pcf) requirements. OTREMstop IA- See table below for minimum thickness of sealant. Apply sealant flush with top of floor surface or with both sides of the wall assembly. Annular Space Min. Packing Material Min, Thickness F- Rating Range, in, Thickness, In. of Sealant, in. Hr. 1/2 to 1 -3/8 0 1 2 1/2 to 1 -3/8 4 112 2 U� `rYste�^ WL 1113 F- Rating = 1 and 2 Hr. T- Rating = 0 Hr. Mffffsa 3735 Green Rd. Beachwood, OH, 44122 Drawing not to scale O Pre -Rated Gypsum Wallboard /Stud Wall Assembly O Metallic Pipei A) Steel Pipe - 4' diam. (or smaller) Sch. 40 (or heavier) steel pipe. B) Iron Pipe - 4' diam. (or smaller) cast or ductile iron pipe. C) Condult - 4' diam. (or smaller) EMT or rigid steel conduit. D) Copper Tubing - 4' diam. (or smaller) Type L (or heavier) copper tubing. E) Copper Pipe - 4' diam. (or smaller) Regular (or heavier) copper pipe. The annular space shall be min. 1/4' to max, 5/8' within the firestop system. 3O TREMstop IA- Min, 1/2' thickness of sealant applied within opening. Additional sealant to be applied so that a min. of 1/4' crown is formed around penetrating Item. 2 Hour Fire Rated Through �`o5s 1 f /P(Y Penetration Firestop for Single U� Plastic Pipe through VEame 3735 Green Rd, ® Concrete Floors or Walls Beachwood, OH, 44122 sJ�ste�` using TREMstop IA. CAJ 2184 F- Rating = 2 Hr. Drawing not to scale T- Rating = 1 1/2 Hr. 4 d 4 l`1 Pre -Rated Concrete Floors or Block Walls = Min. 4 -1/2' thickness. O Plastic Pipei A) Non. 2' diam. (or smaller) Sch. 40 PVC pipe. B) Nom. 2' diam. (or smaller) SDR17 CPVC pipe. NOTE: For use In closed (process or supply) piping systems. OForming Material- Foam backer rod firmly packed into the opening as permanent form. OTREMstop IA- Sealant applied within opening, flush with top surface of floor or both surfaces of wall assembly as shown in table below. When required, apply additional sealant such that a min. 1/8' crown is formed around the penetrating Item. Max. Pipe Annular Space, Min. Sealant Sealant Crown Diameter, in. in. Thickness, In. Required 1 -1/2 3/8 to 3/4 1/2 Yes 2 1/4 to 3/8 1 No Qys i PlPQ, U� `iYste�` WL 2176 F- Rating = 1 Hr. T- Rating = 0 Hr. vmwoe 3735 Green Rd. Beachwood, OH, 44122 Drawing not to scale O Pre -Rated Gypsum Wallboard /Stud Wall Assembly O Plastic Pipe - Nom. 2' diam. (or smaller) Sch. 40 solid core PVC or SDR 17 CPVC pipe for use In closed or open piping systems, The annular space shall be min. 0' to max. 7/8' within the firestop system. O TREMstop IA - Min, 1/2' thickness of sealant applied within opening. Additional sealant to be Installed such that a min. 1/4' crown is formed around the penetrating Item. 201 oo n.e. 21 avenue no. miami beach, 11 33179 a N 4) U m o U) CL - — 1 O o N 0. -i- v U 4 1` U v in (D T ' v 0 t a 0 O of 13039 c ��1i. ... � gyp• r� ■ ■ E O w 0 co LL O Cc CC W a in ■ LL OD 00 CC ca 114C W o 0 J ul Q (n 0 -0 LL_ L Q Ld Z) N_ >0 t L V) W V Z 0 O r LL_ a— IU) c� DRAWN. E.D.A. CHECKED R.P. DATE 11 -30-05 SCALE AS NOTED JOB NO. 0423 SHEET A -4 OF 4 SHEETS