Loading...
06-760-001A ih i M i JOIST SHORING: TYPE I i0 II SINGLE ELLIS SHORE M UNBRACED : DOUBLE ELLIS SHORES 2 J, UNBRACED ,42' -0' 2' -0' MAX. L/2 L/2 MAX. i ih t 2' -0' MAX. TYPE II TYPE III SINGLE ELLIS SHORE UNBRACED 2' -0' 44— MAX. MAX, L/3 L/3 L/3 TYPE IV 21=0' MAX. L/4 L/4 I L/4 TYPE V 6" BEAM (lJ 2 ENDS OF JOISTS SUPPORTED ON SOFFIT BEAMS 4' -0" Ir L/3 L/3 L/3 TYPE VI zo i i� i 0 i 0 i SINGLE ELLIS SHORE UNBRACED DOUBLE ELLIS SHORES UNBRACED - 2' -0' MAX. SINGLE ELLIS SHORE UNBRACED DOUBLE ELLIS SHORES UNBRACED - 2' -0' MAX. 20k Tower JOISTS 6" BEAM BRACING 2 MID HEIGHT ENDS OF JOISTS REQUIRED OVER 16' SUPPORTED ON SOFFIT BEAMS 4' -0" 4' -0" L/3 L/3 L/3 20k Tower END SHORES NOT REQUIRED WHERE END OF JOIST IS SUPPORTED BY SOFFIT BEAM. I TYPE VII MAX. [T L /4 I L/4 L/4 I, L/4 A 4 2' -0' MAX. L/3 - L/3 L/3 DOUBLE ELLIS SHORE UNBRACED TRIPLE ELLIS SHORES UNBRACED MAX, SINGLE ELLIS SHORE UNBRACED 2'-0' MAX. SOFFIT BEAM SHORING V -0" 20k Tower 7' -0" Max. 7' -0» Max. DOUBLE ELLIS SHORES UNBRACED 7' -0" 20k Tower 20k Tower 7' -O" Max. 7' -0" 7' -0" Max. 4 C�1 DOUBLE ELLIS SHORES UNBRACED 5' -0" 5' -0" 5' -0" W -0" Max. Max. Max. Max. ALTERNATE SHORING FOR SB D571, DD572 & D753 EAST OF 18 LINE; D507, D508, D509, D512 & D513 ON E LINE. DOUBLE ELLIS SHORES UNBRACED 7'-0" 20k Tower 7' -0" 20k Tower 7' -0" Max. 7' -0» Max. 7' -0" 1 Max. DOUBLE ELLIS SHORES UNBRACED 7 -0' 201< Tower 20k Tower 7 I -0" 20k Tower 7 I -0 • " Max. 7' -0" 7' -0" Max. 7' -0» Max. DOUBLE ELLIS SHORES UNBRACED 7'-0" L20k Tower 7'-0" 20k Tower 7' -0" 201< Tower 7'-0" Max. 7' -0" 1 Max. 7' -0» 1 Max. 1 V -0» 1 Max. Vk,REVIEWED AND APPROVED ❑ REVIEWED, MARKED AND APPROVED RESUBMIT CORRECTED COPY FOR FILING ❑ REVISE AND RESUBMIT ❑ NOT REVIEWED REVIEWED ONLY FOR THE LIMITED PURPOSE OF THE CHECKING FOR CONFORMANCE WITH THE INFORMATION GIVEN AND THE DESIGN CONCEPT EXPRESSED IN THE FULL SET OF CONTRACT DOCUMENTS. IT DOES NOT AUTHORIZE CHANGES IN THE CONTRACT SUM. REVIEW OF SHOP DRAWINGS IS NOT CCNDUCTED FOR DETERMINING THE ACCURACY AND COMPLETENESS OF DETAILS. QUANTITIES OR FOR SUBSTANTIATING FABRICATION INSTALLATION INSTRUCTION OR PERFORMANCE OF EQUIPMENT OF SYSTEM, ALL OF WHICH SHALL REMAIN THE SOLE RESPONSIBILITY OF THE CONTRACTOR. REVIEW OF SHOP DRAWINGS DOES NOT CONSTITUTE APPROVAL OF SAFETY PRECAUTIONS, CONSTRUCTION MEANS, METHODS, SE- QUENCES OR PROCEDURES, NOR DOES IT INDICATE APPROVAL OF ASSEMBLY OF WHICH THE ITEW cS A COMPONENT, COORDINATION OF ALL TRADES SHALL REMAIN THE SOLE RESPONSIBILITY OF THE CONTRACTOR. CONTRACTOR MUST REVIEW ALL QUANTITIES AND DIMENSIONS AT THE SITE. GF /CONSULTING ENGINEERS, INC. B_ DATE: DOUBLE ELLIS SHORES UNBRACED RESHORING; SHORING NOTES: 1 - SHORING POINTS MUST BE LOCATED AS.. SHOWN IN THE SHORING DIAGRAMS. 2 - ELLIS SHORES SHALL BE NOMINAL 4 "X4 ", NO. 1 GRADE DOUGLAS FIR OR YELLOW PINE, FREE FROM KNOTS, CRACKS AND ROT. 3 - MUD SILLS, 3/4" PLYWOOD, TWO LAYERS' 16 "X16 ", SHALL BE USED WHEN ELLIS SHORES ARE SUPPORTED ON FILL; THREE LAYERS, 3/4" PLYWOOD, 24 "X24 ". TIERED, SHALL BE USED WITH SCAFFOLD FRAMES. 4- THE GENERAL CONTRACTOR IS RESPONSIBLE FOR PROVIDING PROPER COMPACTION OF THE SOIL TO SUPPORT THE SHORING LOADS. THE SHORING LOADS ARE BASED ON 3000 PSF SBEARING CAPACITY. 5 - THE INTERMEDIATE SHORES ARE TO BE SET AT AN ELEVATION ABOVE THE ELEVATION OF THE ENDS OF THE JOISTS "ACCORDING TO THE "SHORE SET" OR "CROWN" DIMENSIONS SHOWN ON THE JOIST ERECTION DRAWINGS. 6 - THE INTERMEDIATE SHORES SHALL REMAIN IN PLACE UNTIL THE SLAB CONCRETE HAS REACHED 70% OF THE DESIGN STRENGTH. THE END SHORES MAY BE REMOVED AFTER 24 HOURS. 7 - THE DECK FORMING FOR JOISTS SPACED 4'-8" AND LESS MAY BE STRIPPED AFTER 24 HOURS. DECK FORMING ON LARGER SPACINGS MAY BE REMOVED AFTER 48 HOURS. 8 - STRUCTURES WITH MULTI - LEVELS OF JOISTS AND /OR SOFFIT .BEAMS REQUIRE RESHORING OF THE POURED LEVELS BEFORE SHORING THE NEXT LEVEL. THE SHORING POINTS MUST BE LOCATED AS SHOWN ON THE RESHORING DIAGRAMS. EXISTING SHORES THAT ARE TO BE USED AS RESHORES MUST BE LOOSENED AND RESET TO TOUCH THE BOTTOM OF JOIST OR SOFFIT BEAM. 9 - DESIGN OF THE DECKING AND SUPPORTS AND BEAM FORMING IS BY OTHERS. 10 - INSPECTION OF THE INSTALLATION OF THE SHORING IS BY OTHERS. DESIGN LOADS: 4%" SLAB - 57 PSF 8" JOIST - 48 PLF 12" JOIST - 68 PLF 16" JOIST - 93 PLF 24" JOIST - 174 PLF CONSTRUCTION LOAD - 50 PSF ONE FLOOR OF SHORING UNDER FLOOR BEING POURED, WITH TWO FLOORS OF RESHORING BELOW. SHORES AT ENDS OF SOFFIT BEAMS AT COLUMNS AND SHORES AT ENDS OF JOISTS AT BEAMS NOT REQUIRED ON RESHORED FLOORS. m 5/30/05 m 3/17/06 ® 4/6/06 ROO ELF m- , 63'_6, 2 THFLOOR 17 50'_6• 4TH FLOOR EU� 37'_6• 3RD FLOOR ELF f - 6' SEEFLOOR EUE RECEIVED APR 12Lu GF CONSULTING ENGINEERS