06-743-0065th Floor Fire Sprinkler Ceiling Plan 012 4 8 16 III I 1 I SCALE: 1/8' =1' -0' 5th Floor Fire Sprinkler Piping Plan 0 1 2 4 12 I I I I I SCALE: 3/16' =1' -0" Ke y Plan NO SCALE MAXIMUM DISTANCE BETWEEN HANGERS .... SCHEDULE D21, CONCRETE SLAB 2. POWDER DRIVEN STUD 1' (SIZE VARIES, SEE PLAN) 3. ROD COUPLING 1 -1/4' (SIZE VARIES, SEE PLAN) 4. ALL THREAD ROD 5. NOMINAL PIPE SIZE (in.) 3/4" 1' 1 -1/4" 1 -1/2' 2' 2 -1/2" 3' 3 -1/2" ¢• 5" F' < < . 8" (� STEEL PIPE EXCEPT THREADED UGHTWAU_ N/A 12 -0 12 -0 15 -0 15 -0 15 -0 15 -0 15 -0 15 -0 15 -0 15 =0 " 15 -0 " I THREADED LIGHTWALL N/A 12 -0 12 -0 12 -0 12 -0 12 -0 12 -0 N/A N/A N/A NIA N /A<<� STEEL PIPE COPPER TUBE 8 -0 8 -0 10 -0 10 -0 12 -0 12 -0 12 -0 15 -0 15 -0 15 -0 154 . 15 -0 " .. CPVC 5 -6 6 -0 6 -6 7 -0 8 -0 9 -0 12 -0 N/A N/A N/A N %" ` N/A POLYBUTYLENE (IPS) N/A 3 -9 4 -7 5 -0 5 -11 N/A N/A N/A N/A N/A N/A N/A POLYBUTYLENE (CTS) 2 -11 3 -4 3 -11 4 -5 5 -5 N/A N/A N/A N/A N/A N/A N/A I .aa rA d POWDER DRIVEN STUD & ALL THREAD ROD SIZES FOR 1' THRU 4' PIPE 3/8' IS TO BE USED POWER DRIVEN STUD Hanger Details NO SCALE SCHEDULE D21, CONCRETE SLAB 2. POWDER DRIVEN STUD 1' (SIZE VARIES, SEE PLAN) 3. ROD COUPLING 1 -1/4' (SIZE VARIES, SEE PLAN) 4. ALL THREAD ROD 5. HANGER RING 15'-0" MAX. (SIZE VARIES, SEE PLAN) 6, PIPE Hanger Details NO SCALE SYMBOL Hanger Location Wal PIPE SIZE A B* C 1' 3'-0' MAX. 12' -0" MAX. 3' MIN. 1 -1/4' 4' -0' MAX. 12' -0" MAX. 3" MIN. 1- 1 /2'TH 8' 5'-0" MAX. 15'-0" MAX. 3" MIN. 155 TYFRB OR BRASS UPRIGHT TY3131 A B• C SPRINKLER HEAD 41 I-- LL STEEL PIPE LHANGER • MAXIMUM HANGER SPACING FOR THREADED LIGHTIMALL STEEL PIPE IS 12' -0' FOR ALL PIPE SIZES SYMBOL QTY SIZE K TEMP MODEL SIN 0 113 1/2' 5.6 155 RFlI OR WHT FLUSH PEND TY3531 O - 1/2" 5.6 155 TYFRB OR BRASS UPRIGHT TY3131 • DROP IN ANCHORS & ALL THREAD ROD SIZES FOR V THRU 4' PIPE 3/8' IS TO BE USED FOR 6' & 8' PIPE 1/2' IS TO BE USED DROP IN ANCHOR 4 Q 4 tli x ARMOVERS GREATER THAN 24' IN LENGTH SHALL BE SUPPORTED BY A HANGER, T 8 ___0 6� SCHEDULE 1, EXIST BRANCHLINE OR MAIN —Q 2. NEW TEE (SIZE VARIES, SEE PLAN) 3. ARMOVER.w _O (SIZE VARIES, SEE PLAN) 4. 1' 90• ELL OR TEE 5. DROP (SIZE VARIES, SEE PLAN —Qj MAY FEED TEE SUPPLYING MORE THAN ONE SPRINKLER) 6. NEW SEMI- RECESSED PENDENT FIRE SPRINKLER 7. CEILING. 8. NIPPLE 9, REDUCING COPULING (SIZE VARIES, SEE PLAN) SCHEDULE 1. NEW BRANCHLINE OR MAIN 2 NEW MECH TEE OR WELDED OUTLET (SIZE VARIES, SEE PLAN) 3. SPRINKLER HEAD Sprinkler Detail NO SCALE PENDENT SPRINKLER HEAD(S) ON SNAP-O -LET OR MECHANICAL TEE FLOW SWITCH CHECK VALVE CONTROL VALVE with Tamper (Wired by others 0 to i LANDING IF 2' DRAIN LINE ti ; ....�:,1: FLOOR VALVE 6' -0' AFF (U.N.O.) 2' Drain Riser Tie each foor into drain and pipe to suitable location at exterior of the building 1/4' GAUGE RISER CLAMP (TYPICAL) LANDING APPROVED MI1MR -DADS COUNTY FIRE DEPARTMENT FIRE SLPPRPSSM! WATER MAIN EXT. Typical Floor DATE: BY: A seewnL•Jv NTS (FOR REFERENCE ONLY) SEE LAYOUT DRAWINGS FOR SIZE AND LOCATION To System FLOOR CONTROL VA. ASSEMBLY 2 6' -0' AFF QN11) 4' RISER ILL J�co M C X 1_�? t w4' i �f SCHEDULE D1. CONCRETE SLAB 2. DROP IN ANCHOR (SIZE VARIES, SEE PLAN) 3, ALL THREAD ROD (SIZE VARIES, SEE PLAN) 4. HANGER RING 5. PIPE SCHEDULE 1, EXIST BRANCHLINE OR MAIN —Q 2. NEW TEE (SIZE VARIES, SEE PLAN) 3. ARMOVER.w _O (SIZE VARIES, SEE PLAN) 4. 1' 90• ELL OR TEE 5. DROP (SIZE VARIES, SEE PLAN —Qj MAY FEED TEE SUPPLYING MORE THAN ONE SPRINKLER) 6. NEW SEMI- RECESSED PENDENT FIRE SPRINKLER 7. CEILING. 8. NIPPLE 9, REDUCING COPULING (SIZE VARIES, SEE PLAN) SCHEDULE 1. NEW BRANCHLINE OR MAIN 2 NEW MECH TEE OR WELDED OUTLET (SIZE VARIES, SEE PLAN) 3. SPRINKLER HEAD Sprinkler Detail NO SCALE PENDENT SPRINKLER HEAD(S) ON SNAP-O -LET OR MECHANICAL TEE FLOW SWITCH CHECK VALVE CONTROL VALVE with Tamper (Wired by others 0 to i LANDING IF 2' DRAIN LINE ti ; ....�:,1: FLOOR VALVE 6' -0' AFF (U.N.O.) 2' Drain Riser Tie each foor into drain and pipe to suitable location at exterior of the building 1/4' GAUGE RISER CLAMP (TYPICAL) LANDING APPROVED MI1MR -DADS COUNTY FIRE DEPARTMENT FIRE SLPPRPSSM! WATER MAIN EXT. Typical Floor DATE: BY: A seewnL•Jv NTS (FOR REFERENCE ONLY) SEE LAYOUT DRAWINGS FOR SIZE AND LOCATION To System FLOOR CONTROL VA. ASSEMBLY 2 6' -0' AFF QN11) 4' RISER ILL J�co M C X 1_�? t w4' i �f