06-51R-001N
I
A.
AS 51JILTS
THE REVISIONS SHOWN ON THESE SET OF DRAWINGS HAVE
BEEN COPIED FROM THE CONTRACTOR'S A5 -5UILT MARK
UP SET. SUCH REVISIONS REFLECT CHANGE& AND FIELD
COORDINATIONS DONE BY THE CONTRACTOR DURING THE
COURSE OF CONSTRUCTION.
DIEZ ARCHITECTURE, INC. IS NOT iz1=5PON515LE FOR THE
ACCURACY OF THE INFORMATION CONTAINED HEREIN.
TENANT
VACANT TENANT *2
KEY PLAN N.T.S.
I VIININ - I- T -
LINES TYPICAL.
MIN 18' C.F.A. ON PULL SIDE C
DOOR W/ MIN 12' e PUSH SIDE
TYPICAL AT ALL DOORS.
TYPICAL. AT ALL WALL_ JOGS
AND NICHES,
MIN OF 12' LAN PUSH SIDE OF L... ..h
TYPICAL AT ALL DOORS WITH
BOTH A CL05ER AND A LATCH.
DOOR ENTRY DETAIL 1/4n
FIRE SPRINKLER GENERAL NOTES
1- OFFICES TO BE FULLY SPRINKLED. CONTRACTOR TO
PROVIDE SHOP DRAWINGS FOR ARCHITECT'S REVIEW.
2- COORDINATE LOCATION OF SPRINKLER LINES AND
HEADS WITH OTHER TRADES.
3- COORDINATE HEIGHT OF SPRINKLES HEADS WITH
FINISHED CEILING HEIGHTS A$ INDICATED ON THE
ARCHITECTURAL DRAWINGS.
4- MAXIMUM AREA AND D15TANCE COVERAGE PER
SPRINKLER HEAD SHALL BE AS SET FORTH 13Y NFPA.
BULLETIN 13.
5- MINIMUM DISTANCE FROM SPRINKLER HEAD TO ANY
OBSTRUCTIVE ELEMENT SUCH AS LIGHT, AIR
DISTRIBUTION DEVICES, ETC. SHALL BE AS SET FORTH
BY NFP,A_ BULLETIN 13_
GLASS. PROVIDE BREAK METAL ON END TO
MATCH BUILDING STOREFRONT COLOR
TYPICAL a NON -SMOKE BARRIER PARTITIONS
WHERE SHOWN ON PLANS.
6- ALL PIPING SHALL BE AS SET FORTH BY NF.P-A.
BULLETIN 13.
i- TEST ALL NEW PIPING AS REQUIRED AT 250 PSIG.
6- CONTRACTOR SHALL PROVIDE A COMPLETE SET OF
SHOP DRAWINGS INCLUDING CALCULATIONS.
9- HEADS TO BE CENTERED IN TILES,
GENERAL NOTES
1- PROVIDE FIRE EXTINGUISHERS BY LAR5EN5
MODEL No: MP -5, 2A -108:C RATED IN A SEMI
RECESSED FIRE EXTINGU15HER CABINET BY
LAR5EN5 MODEL * AL- 24043-R3, FULL GLASS
FRONT W/ LARSEN LOCK 1 PER 2500 BE ( 3 )
SUBMIT SHOP DWG5 FOR REVIEW,
R F.E. = FIRE EXTINGUISHER
BARFILK PAR1II1UN* A5
REQUIRED ALONG WALLS
AND WINDOWS. TYP.
PARTIAL FOURTH FLOOR PLAN
SCALE: 3/16" =1'-0'
FLOOR AREA: 10,340 S.F. (11,764 S.F. TOTAL FLOOR)
NOTE: FIELD VERIFY AND MEASURE
ALL EXISTING CONDITIONS
NOTIFY ARG41TECT OF ANY
DISCREPANCIES.
PARTITION LEGEND
P -1 NEW 3 5/15'25 GA METAL 5TUD5 Q 24' OC W/ 5/8' GYP. BD * EACH SIDE.
P -2 NEW I HR FIRE RATED PARTITION 3 5/8' 25 GA METAL STUDS W/ 5/8' TYPE X GYP. BD 6 1rACH SIDE:
P -3 NEW 6' 25 GA METAL STUDS 0 24' OC W/ 5/8' GYP. BD a EACH 51 DE.
P -4 NEW - 3 5/6'25 GA GYP. BD. Q EACH SIDE W/ CORRIDOR/TENANT SIDE TO STRUCTURE ABOVE.
P -5 A NEW V 25 GA. METAL STUDS « 24" OC W/ 5/8' GYP, BD 4 INTERIOR SIDE (FURR OUT WALL FOR PLUMBING).
P -6 NEW MIN 5/8' 25 GA 1 ETAL STUDS a 24' OC W/ 5/8' GYP. BD t SOUND BATTS TO UNDERSIDE OF STRUCTURE.
i•i• !!•iY Y• •• rY�rV •uV V•
i • • U Y •
� u • ur
`� • ! V V U
\� `�` u,M ynU� w, yN v�� I • u r • Y Y
x *� Yuu •uuu
i••• • • Y! Y U V i it U • U V Y• •
R
ft
7430 Sw 48th street _
miarni, florida 33155
phone: (305) 663 -1970
fax: (305) 663 -2312
e —mail: peter@diezorchitecture.com
pedro diez, I17 a
president ar 0008996
I I
ENGINEERING CONSULTANT
F IH �1 I :
I.
PAG,
I,
0141
Officeli Building
4th loor
I
777T- ;n' I T II °td z w�
6141 SUNSET DRIVE
SOUTH MIAMI, FLORIDA
I!I
PROJECT No1 04- 158.04
REVISIONS
f J 02 -02 -2006
4 03 -11 -2006
W -1 EXISTING V CONC. BLOCK WALL W/ 5/V GYP. BD OVER 7/8' FURRING. (STAIRWAY INTERIOR TO REMAIN UNFINISHED).
W -2 EXISTING GONG COL W/ 5/8' GYP. BD OVER 1/8" FURRING.
W -3 3' -0' HIGH MASONRY WINDOW WALL W/ 5/8' GYP. BD. OVER FURRING.
» »rAx
I� � Y .M y v • tl � M
4.
' »4,rlli »�'��,
ME
SCALE: A SHOWN
...:> ill
DATE: DE I MBER 12, 2005