06-51-028
4TH FL WIREWAY EXIST. METER 3DP L I I TENANT 4A SEE R16ER THI SHEET EXIST. TENANT 46 SEE RISER THIS WIREWAY TO SWFFT BE MOUNTED TO STRUCTURE! I I EXISTING 5T14 FL WIREWAY FUTURE TENANT F — -- - - - - -- -7 I I 2ND FLOOR METER ROOM FIRE ALARM GENERAL NOTES: I. MINIMUM RACEWAY SIZE $HALL BE 3/4'. WIRING TO COMPLY WITH N.E.C. ARTICLE 160 -16. 2. ACTUAL FIELD WIRING REQUIREMENTS FOR NEW DEVICES $HALL BE AS INDICATED BY EQUIPMENT SUPPLIER ON APPROVED 6140P DRAWINGS. 3. MAXIMUM CONDUIT FILL - 40% OF CONDUIT AREA 4. ALL EQUIPMENT SMALL BE U.L. LISTED BY UNDERWRITER6 LABORATORIES FOR THE INTENDED USE AND SHALL MEET WITH THE APPROVAL OF THE LOCAL FIRE AUTHORITIES. THE COMPLETE INSTALLATION $HALL BE MADE M ACCORDANCE WITH NRP.A. X12 SERIES. ALL LOCAL CODES AND REQUIREMENTS, NFP.A. *101 AND N.E.C. ARTICLE 160. 5. FIRE ALARM CONTRACTOR TO PROVIDE ALL PROGRAMMING, ALL FINAL CONNECTIONS, ALL TESTING AND CERTIFICATION. 6. PROVIDE NEW CONDUIT AND WIRING AS REQUIRED TO PROVIDE A COMPLETE AND WORKABLE 6Y6TEM AS DESCRIBED M SPECIFICATION SECTION 16121. 1. CONTRACTOR SHALL VERIFY WITH MANUFACTURER FOR ACTUAL MANUFACTURER WIRING RECOMMNEDATION$. 8. THE DEVICE DESIGNATION INDICATED 16 FOR INFORMATION ONLY. THE CONTRACTOR SHALL PROVIDE HIS OWN DEVICE DESIGNATION FOR APPROVAL. 3 MATCH EXISTING FIRE ALARM DEVICES, WIRE CIRCUITS AND PROVIDE POWER SUPPLY AS REQUIRED. 10. CONTRACTOR TO PROVIDE BATTERY CALCULATION TO AVOID BATTERY OVERLOAD IN THE SYSTEM. II. CONNECT NEW APPLIANCES INTO EXISTING NOTIFICATION CIRCUIT. 12. CONNECT NEW DETECTION DEVICE INTO THE EXISTING DETECTOR LOOP. 13. HORN /STROBE SHALL MEET 'ADA' REQUIREMENT6 OF V -6' AFF. OR 6' BELOW CEILING WHICHEVER 16 LOWER. 1/2" I PANEL 3DP PARTIAL RISER NOTES ID EXISTING 3000 AMP 120/208V, 3PH, 4W PANEL 'HDA' ® EXISTING 12' X 12' X 60' WIREWAY TO REMAIN Q3 EXISTING (2) SETS OF 4 -600 MCM t 11 /0 GND IN 4' 00140 EACH ® KWHR METER IN NEMA I ENCLOSURE Q5 NEW 24' X 24' X 46' WIREWAY ® NEW 2 PANEL 4A. SEE SCHEDULE OQ NEW PANEL 46. SEE SCHEDULE ©® 3 POLE 400 AMP DISC SWITCH NEMA I WITH 250 AMP FU6E6 42 KAIC. (PANEL '4% 0 ® 2 SETS, OF 4h t 104 GND IN 2' CONDUIT EACH (PANEL '4A') EXISTING 3PWOAMP CIRCUIT BREAKER It 2 -2' EC WITH PULLWIRE FOR FUTURE TENANT SPACE 12 2' EC WITH PULLWIRE FOR SPACE 03 STUB 2' EC INTO EXISTING CEILING SPACE AND CAP 0 ® 41 t 1% GND IN 2' COND. (PANEL '4B9 ® Q5 3 POLE 20CAMP DISC. SWITCH NEMA 1 WITH 125 AMP FUSES 42 kAIC. (PANEL "46') 1.1 C/-T r5^11AA PARTIAL ELECTRICAL RISER DIAGRAM N.T.S. li,�v CHECK rN'A�19E PL-V] E DATA (-)F A/C EQIJIPME,'NT, HOT VdA,fER N&I RS -'ND OTHER EQu1PMV Nr 1'OOli'rA1P[ CCRR.EC r W'1RE SIZES AND )VExcu:ZREIVr PRO IT 4(J;r[ U'% "E "3r.ZVICr_' Cam' PW' I I';r - i1J13Ji�:4,'r T c? r I�Ec�fRr�:nl DATA / VOICE OUTLET (TYI'J VOICE OUTLET l TYPJ VOC WITH PULLWIRE TO PBX ROOM. THIS FLOOR. I% r ,J N' OIL J Id`,fdl IYy_i.l 3 T' 3 O_f i ):3i .ii 14 �CI i.7d�isy.� � iff T SCl�s rvl v LL, 0 d S:3Ijs 3 ( y:3J Ol I N :3117,11 .1 O [� 31 ,OH 3[.," I�3111 t) AA �r�iii "3111 1 Xr I 4' -0' XS' -0' X 3/4' PLYWOOD PAINTED BLOCK TELEPHONE TERMINAL BOARD 3RD FLOOR TO FIRE ALARM PANEL I6T FLOOR "RO SU T i0 Rru -1 ROOF t .�� TELEPHONE DATA RISER DIAGRAM N.T.S. FIELD INS KI,rION 4 DS DR D6 DR D6 DR AHU -4 -3 AHU 4 -2 AHU -4 -1 FAC'P IN 1st FLOOR 3rd FLOORR (TYPJ 2nd FLOOR EXISTING FIRE ALARM CONTROL PANEL (FRCP) FIRST FLOOR FIRE ALARM RISER DIAGRAM N.T.S. SULij;:C,r To FI,',—RI A `1J 'T TO diez architecture, inc. 7430 sw 48th street miami, florida 33155 phone: (305) 663 -1970 fax: (305) 663 -2312 e —mail: peter@diezarchitecture.com pedro diez, ra president or 0008996 ENGINEERING CONSULTANT G141 Office Building 4th Floor 6141 SUNSET DRIVE SOUTH MIAMI, FLORIDA PROJECT No. 04- 158.04 REVISIONS 2 REV 01/21/06 BLDG. DEPT. COMM. ELECTRICAL ROOM PLANS AND RISER DIAGRAM SCALE: AS SHOWN