Loading...
06-51-008FINISH SCHEDULE FLOOR ROOM NAME FLOOR BASE WALLS CEILING F TGL REMARKS xoi5 - PAINT PAINT - - - SEE NOTES 1, 12 - - -- - - SEE NOTES 1 - -- - - - -- 2 RESTROOM 1 3' -0' 6' -8' WOOL WOOD D A B C - -- -- 3 4 ELECTRICAL ROOM A/C ROOM 1 2' -10' 3' -0' 6' -8' 6' -8' 13/& - 13/41 woci HC WOOD SC 5 LOUNGE CLOSET D 2 -2' -0' - WD LOUVER - eo LOUNGE A 3' -0' N 13/4' WOOD 8C PAINT 7 DOCTOR 1 O EXAM 1 `9 EXAM 2 - - -- U N - 110 EXAM 3 !a - - -- - - Ill DOCTOR 2 p >U 112 cnw v 3 -- - 113 FILE ROOM 13/a, WOOD HC 114 REBTROOM 2 COMMON CORRIDOR 13/4' WOOD SC • • • • RESTROOM 3 REFER TO REFLECTED CEILING FOR ELEVATIONS • WAITING ROOMS • - e - -- -- - - -- - • STORAGE 1 13/6, WOOD HC REFER TO REFLECTED CEILING FOR ELEVATIONS • RECEPTIONS • • 111 A/C ROOM 2 • 13/4' WOOD $C - - - -- REFER TO REFLECTED CEILING FOR ELEVATIONS INTERIOR CORRIDORS • 116 EXAM 5 • • - - - - - -- - -- • - REFER TO REFLECTED CEILING FOR ELEVATIONS REFER TO REFLECTED CEILING FOR ELEVATIONS DOCTORS 119 EXAM ( • • • _ _ - - -- • -- ---- -- - -- - OFFICES - 20 • • • � 1 EXAM 1 • REFER TO REFLECTED CEILING FOR ELEVATIONS EXAMS • • - - -- - -- - • - -- - - - - - -- - - - -- -- - -- SEE NOTES 8, 10 -- -- - - - - - - ---- SEE NOTES 1, 12 22 STAIR No. 3 B REFER TO REFLECTED CEILING FOR ELEVATIONS • LOUNGES • METAL I HR • 23 EXAM 8 • • WOOD $C WOOD _ - - -- - REFER TO REFLECTED CEILING FOR ELEVATIONS LABS DOCTOR 4 e • • -- - • 25 DOCTOR 5 REFER TO REFLECTED CEILING FOR ELEVATIONS STORAGE • 26 EXAM 10 • • • -- ___ -- -- 21 - REFER TO REFLECTED CEILING FOR ELEVATIONS RE 8T OOMB • WOOD 8C :28 EXAM 9 REFER TO REFLECTED CEILING FO R ELE VATION5 A/C ROOMS • - :29 OFFICE MANAGER • • 13/6' WOOD HC • - EXPOSED CEILING UNLE55 OTHERWISE NOTED ON PLANS BUSINESS MANAGER STORAGE 2 FILE ROOM • • • .32 NURSE STATION CORRIDOR • 3' -0' 8' -0' 1 3/4' REFER TO REFLECTED CEILING FOR ELEVATIONS _ NURSES STATION 4 STIR • - • .33 WAITING ROOM A 3' -0' 8' -0' • WOOD SC At • - - SEE NOTES 1 12 REFER TO REFLECTED CEILING FOR ELEVATIONS OFFICE / BUS. MANAGER • =34 • A 3' -0' 8' -0' 1 3/4' WOOD SC • PAINT PAINT - - • .35 LOUNGE C 3' -0' 6' -8' REFER TO REFLECTED CEILING FOR ELEVATIONS WOOD HC JANITOR ROOM • - - :36 • A • • - - - - -- - - - - - -- REFER TO REFLECTED CEILING FOR ELEVATIONS • ELECTRICAL ROOM :31 • • • - - -- -- REFER TO REFLECTED CEILING FOR ELEVATIONS - _ _ .38 EXAM 1 - -- WINDOW NOTES I- FIELD VERIFY ALL OPENINGS PRIOR TO ORDERING WINDOWS. 2- INTERIOR WINDOWS TO BE 1/4' CLEAR CATEGORY 2 TEMPERED GLASS IN ALUM FRAMES, FOR INTERIOR APPLICATIONS. 3- SUBMIT SHOP DRAWINGS OF ALL WINDOWS, TO ARCHITECT FOR REVIEW. FINISH NOTES: 1- ALL GYP. BOARD SHALL BE TAPED, SPACKLED AND SANDED SMOOTH TO RECEIVE TWO COATS OF SEMI GLOSS INTERIOR LATEX PAINT. COLOR SELECTED BY DEVELOPER 2- ALL FLOORS TO BE SELECTED BY DEVELOPER 3- AGCOUSTICAL CEILING TO BE ARMSTRONG 2'X VON A WHITE 15116' GRID, GEORGIAN TEGULAR STYLE OR APPROVED EQUAL. 4- PROVIDE CARPET REDUCERS AT ALL CHANGE OF MATERIAL LOCATIONS. 5- PROVIDE A I' WIDE SOLID COLOR VINYL STRIP s ALL CORRIDOR TO DOOR LOCATIONS WHERE FLOORING MATERIALS CHANGE. 6- INTERIOR FINI$HE5 SHALL BE OF CLASS B. FLAMESPREAD 26 -15, SMOKE DEVELOPED INDEX 0 -450. TYPICAL. 1- WOOD DOORS TO BE PAINTED FINISH. 8- CERAMIC TILE WORK s TOILETS TO HAVE COVED BASES AND ASSOCIATED TRIM. DEVELOPER TO SELECT COLOR 9- PROVIDE A 2' WIDE MARBLE THRESHOLD s DOORS FROM TOILETS TO CORRIDOR AND s LOBBY TO HALLWAY. PARTITION LEGEND W -1 EXISTING 8' CONC. BLOCK WALL. PROVIDE 5/8' GYP. BD. OVER 1/8' METAL FURRING s 24' O.C. TO 9' -6' APB. s INTERIOR W/ ALFOIL R -41 INSULATION TO UNDERSIDE OF DECK P -1 NEW 3 5/6' 25 GA METAL STUDS s 24' O.G. W15 /8' GYP. 51). is EACH SIDE TO 9' -6' APP., PROVIDE 4' THICK FIBERGLASS INSULATION WHERE SHOWN ON PLANS. PROVIDE 20 GA STUDS s PHONE/ELECT ROOM$ 4 WHERE CABINETRY 18 SUPPORTED, PARTITION TO BE BRACED TO STRUCTURE ABOVE s 4' -0' O.C. P -2 NEW I HR FIRE RATED PARTITION 3 5/6' 25 GA METAL 5TUD8 s 24' O.G. W/ ONE FULL LENGTH LAYER OF 5/8' TYPE 'X' GYP. BD. APPLIED VERTICALLY WITH I' LONG % DRYWALL SCREWS TO EACH SIDE. SCREWS ARE 6' O.C. s PERIMETER AND 12' O.C. AT THE INTERMEDIATE STUDS. UL 0465. PROVIDE A STENCILED SIGN s 15' -0' O.C. ABOVE CEILING STATING 'FIRE AND SMOKE BARRIER PROTECT ALL OPENINGS'. I' LETTERS ALONG FIRE RATED PARTITIONS. P -3 NEW 6' 25 GA METAL STUDS s 24' O.C. W/ 5/8' GYP. BD. s EACH SIDE TO 15'-V A.F.F. VERIFY MOUNTING OF CABINETS, COUNTERTOPS, ETC. 4 PROVIDE 20 GA STUDS AND 12 GAUGE ANCHOR PLATE$ BETWEEN 8TUD8 THE LENGTH OF THE ITEM. PROVIDE 4' SOUND INSULATION is WALLS WHERE NOTED ON PLANS. P -4 NEW 3 5/6' 25 GA METAL STUDS s 24' O.C. W15 /8' GYP. BD. s EACH SIDE TO 9' -6' AFF. is ONE 61DE AND TIGHT TO STRUCTURE ABOVE s CORRIDOR SIDE, PROVIDE 4' THICK FIBERGLASS INSULATION WHERE SHOWN IN PLANS. PROVIDE 20 GA STUDS s PHONE/l_LECT ROOMS 4 WHERE CABINETRY 18 SUPPORTED. CAULK AND SEAL AS REQUIRED ALONG WALLS, WINDOWS, STRUCTURE ABOVE AND s ALL PENETRATION$. PROVIDE A STENCILED SIGN is 15' -0' O.C. A50VE CEILING STATING 'SMOKE BARRIER PROTECT ALL OPENINGS'. I' LETTERS ALONG SMOKE BARRIER P -5 PURR OUT WALLS FOR PLUMBING W/ 6' 25 GA METAL STUDS s 24' O.C. W/ 5/6' GYP. BD. is INTERIOR SIDE AS SHOWN ON PLANS. P -6 NEW 3 5/8' 25 GA METAL STUDS s 24' O.C. W/ 5/6' GYP. BD. is EACH SIDE AND SOUND BATTING TO UNDERSIDE OF STRUCTURE ABOVE. PROVIDE 20 GA 8TUD8 s PHONE ROOMS 4 WHERE CABINETRY 16 SUPPORTED. CAULK AND SEAL AS REQUIRED ALONG WALLS, WINDOWS, STRUCTURE ABOVE AND s ALL PENETRATION$. PROVIDE A STENCILED SIGN s 15' -0' O.C. ABOVE CEILING STATING 'SMOKE BARRIER PROTECT ALL OPENING$'. I' LETTERS ALONG SMOKE BARRIER CIE NOTE: REFER TO REFLECTED CEILING FOR ROOMS RECEIVING GYP. BD. SOFFIT 4 ELEVATIONS DOOR NOTES: I_ ALL WOOD DOORS SHALL BE PAINT GRADE. VENEERS FINISHED WITH A SEMI GL088 PAINT FINISH. 2- METAL FRAME$ SHALL BE WELDED IN LIEU OF KNOCK DOWN AND PAINTED COLOR SELECTED BY TENANT. SEMI GLOSS FINISH. 3_ SUBMIT SHOP DRAWINGS OF ALL DOORS a FRAMES TO ARCHITECT FOR REVIEW. 4- ALL DOORS AND HARDWARE SHALL COMPLY WITH SECURITY AND FORCED ENTRY REQUIREMENTS AND THE AMERICAN 018ABILITIE5 ACT. 5_ ALL HOLLOW METAL AND WOOD DOORS TO HAVE LATCHSET OR LOCKETS, LEVER DESIGN. BRUSHED S8 FINISH. 6- ALL METAL AND SOLID CORE DOORS TO HAVE 11/21 PAIR OF HINGE$ FULL MORTISE 41/2'X 41/2' 1- PROVIDE WALL DOOR STOP, HAGER MODEL 232W, STAINLESS STEEL AND FLOOR STOP HAGER MODEL 241F OR EQUAL. 8- PROVIDE DOOR CLOSER is FIRE RATED DOORS. 9- $Y 15OL (:�) = EXISTING FIRE RATED DOOR TO REMAIN. 10- DOOR TO BE I HOUR FIRE RATED. 11- UNDERCUT ALL TOILET ROOM DOORS 1'. 12- DOORS TO HAVE TWO PAIR OF HEAVY DUTY HINGE$ WITH METAL OR WOOD FRAME. - DOOR SCHEDULE: FOURTH FLOOR DOOR DOOR OPENING SIZE = N►?ATFIAL FINISH LABEL / UNDER FLOOR MIARK LOCATION ELEV. FIRE RATING CUT HDW. REMARKS W. H. T. DOOR FRAME DOOR FRAME street II CORRIDOR/ CORRIDOR A 3' -0' 8' -0' 1 3/4':.: 13/4' I.000D DC xoi5 - PAINT PAINT - - - SEE NOTES 1, 12 - - -- - - SEE NOTES 1 - -- - - - -- 2 RESTROOM 1 3' -0' 6' -8' WOOL WOOD D A B C - -- -- 3 4 ELECTRICAL ROOM A/C ROOM 1 2' -10' 3' -0' 6' -8' 6' -8' 13/& - 13/41 woci HC WOOD SC 5 LOUNGE CLOSET D 2 -2' -0' - WD LOUVER - eo LOUNGE A 3' -0' 13/4' WOOD 8C PAINT 7 DOCTOR 1 EXAM 1 `9 EXAM 2 - - -- - - - - -- - 110 EXAM 3 - - -- - - Ill DOCTOR 2 112 EXAM 4 -- - 113 FILE ROOM 13/a, WOOD HC 114 REBTROOM 2 13/4' WOOD SC 115 RESTROOM 3 1 3/4' WOOD Sc - - -- -- - - -- - 116 STORAGE 1 13/6, WOOD HC 111 A/C ROOM 2 13/4' WOOD $C - - - -- 116 EXAM 5 - - - - - -- - -- - 119 EXAM ( -- _ _ - - -- -- ---- -- - -- - - - - - - -- - -- -- - - - - 20 DOCTOR 3 � 1 EXAM 1 - - -- - -- - - -- - - - - - -- - - - -- -- - -- SEE NOTES 8, 10 -- -- - - - - - - ---- SEE NOTES 1, 12 22 STAIR No. 3 B METAL HC METAL I HR 23 EXAM 8 A WOOD $C WOOD _ - - -- - 24 DOCTOR 4 -- - - - - - - 25 DOCTOR 5 26 EXAM 10 -- ___ -- -- 21 REBTROOM 4 WOOD 8C :28 EXAM 9 WOOD SG - :29 OFFICE MANAGER 13/6' WOOD HC - '30 31 BUSINESS MANAGER STORAGE 2 .32 NURSE STATION CORRIDOR A 3' -0' 8' -0' 1 3/4' WOOD SC - - .33 WAITING ROOM A 3' -0' 8' -0' 1 3/4' WOOD SC At - - - SEE NOTES 1 12 - - =34 LOUNGE/ CORRIDOR A 3' -0' 8' -0' 1 3/4' WOOD SC WOOD PAINT PAINT - - SEE NOTES 1, 12 SEE NOTES 1 .35 LOUNGE C 3' -0' 6' -8' 1 3/8' WOOD HC - - :36 RESTROOM A - - - - -- - - - - - -- - - - - - - -- :31 LAB - - -- -- - _ _ .38 EXAM 1 - -- - - .39 EXAM 2 - - - - - -- - -- 40 RE8TROOM - 41 OFFICE 5 - - - - - -- 42 OFFICE 4 - - - -- - - -- — ,43 OFFICE 3 - - - - -- 44 STORAGE - - - -- 45 OFFICE 2 - -- - - - -- - 46 OFFICE I 41 A/C CLOSET D 3' -0' 6' -8' - WD LOUVER - - - 48 WAITING A 3' -0' 6' -8' 13/6, WOOD HC WOOD PAINT - - - - - SEE NOTES 1 49 WAITING/ CORRIDOR A 3' -0' 8' -0' 1 3/4' WOOD SC WOOD PAINT - SEE NOTES 1, 12 PAINT PAINT _ '50 VACANT A 3' -0' 8' -0' 1 3/4' WOOD SC WOOD - SEE NOTES 1, 12 51 152 53 ELECTRICAL ROOM JANITOR REBTROOM A A A 3' -0' 3' -0' 3' -0' 8' -0' 8' -0' 6' -0' 1 3/4' 1 3/4' 1 3/4' WOOD SC WOOD 8C WOOD SC 41 - - - - - - - - - SEE NOTES 1, 12 SEE NOTES 1, 12 SEE NOTES 1, 12 DOOIR TYPE ELEVATIONS 1/40 .AJ,I: ski "? `(' Par EN.,(� r fliTr ......... ..� ie 7430 sw 48th street miami, florida HARDWARE e IC INTERIOR OF EXIT DOOR s TENANT SIDE. phone: (305) 663 -1970 fax: (305) 663 -2312 e -mail: peter ©diezarchitecture.com . pedro diez, ra president ar 0008996 ENGINEERING CONSULTANT D A B C DOOIR TYPE ELEVATIONS 1/40 .AJ,I: ski "? `(' Par EN.,(� r fliTr ......... ..� ie 7430 sw 48th street miami, florida 33155 phone: (305) 663 -1970 fax: (305) 663 -2312 e -mail: peter ©diezarchitecture.com . pedro diez, ra president ar 0008996 ENGINEERING CONSULTANT 6747 Office Building 4th Floor 6141 SUNSET DRIVE SOUTH MIAMI, FLORIDA PROJECT No, 04- 158.04 REVISIONS DOOR + FINISH SCHEDULES FOURTH FLOOR