06-51-005OCCUPANT LOAD AND
BUILDING TYPE
GROSS FLOOR AREA 11,164 SQ.FT.
CODE 4 OCCUPANCY —2001 FLORIDA BUILDING CODE
BUSINESS CROUP B
OCCUPANT LOAD (1/100 SF.) 11,1641100 = 118
BUILDING CONSTRUCTION TYPE —TYPE III PROTECTED
PLUMBING FIXTURES REQUIRED AS PER F15C -P- 403.1, BUSINESS
PER 11,164 SQ FT
PER 8,380 $Q FT
3 WC
2 WC
2 LAY
1 LAV
1 SERVICE SINK
I SERVICE SINK
2 DF
I DF
PLUMBING FIXTURES PROVIDED ON FOURTH FLOOR
AREA OF U10RK ON FOURTH FLOOR: 8,380 $0, FT.
1 U1C
1 LAV
1 SERVICE SINK
2 DF
I SERVICE SINK
BUILDING WILL HAVE A FIRE ALARM AND A SPRINKLER SYSTEM
FOURTH FLOOR FIRE EXIT PLAN
SCALE: 3/16' - T -0"
G941
Office Building
4th Floor
6141 SUNSET DRIVE
SOUTH MIAMI, FLORIDA
...................- ._...........
PROJECT No. 04- 158.04
REVISIONS
FOURTH FLOOR
FIRE EXIT PLAN
.... ..................: