Loading...
06-51-003C 100 ^I IT AC [Of•/V IICOCPY G ICG N IT AG OCN IICCn ACa1 v AOI' -= A TENANT "I VACANT TENANT *1 KEY PLAN N.T.S. LINES TYPICAL. MIN 18' CRA. ON PULL SIDE C DOOR W/ MIN 12' a PUSH SIDE TYPICAL AT ALL DOORS. TYPICAL AT ALL WALL JOG!5 AND NICHES. MIN OF 12' ON PUSH SIDE O= TYPICAL AT ALL DOORS WITH BOTH A CLOSER AND A LATCH. DOOR ENTRY DETAIL 1/49 FIRE SPRINKLER GENERAL NOTES I- OFFICES TO BE FULLY SPRINKLED. CONTRACTOR TO) PROVIDE SHOP DRAWING5 FOR ARCHITECT'S REVIEW. 2- COORDINATE LOCATION OF SPRINKLER LINES AND HEADS WITH OTHER TRADES. 3- COORDINATE HEIGHT OF SPRINKLES HEADS WITH FINISHED CEILING HEIGHTS AS INDICATED ON THE ARCHITECTURAL DRAWINGS. 4- MAXIMUM AREA AND DISTANCE COVERAGE PER SPRINKLER HEAD SHALL BE AS SET FORTH BY NF.PA. BULLETIN 13. 5- MINIMUM DISTANCE FROM SPRINKLER HEAD TO ANY OBSTRUCTIVE ELEMENT SUCH AS LIGHT, AIR 015TRIBUTION DEVICES, ETC. SHALL BE AS SET FORTH BY NF.PA. BULLETIN 13. GLASS. PROVIDE BREAK METAL ON END TO MATCH BUILDING STOREFRONT COLOR TYPICAL is NON -SMOKE BARRIER PARTITIONS WHERE SHOWN ON PLANS, 6- ALL PIPING SHALL BE AS 5ET FORTH BY NF.PA. BULLETIN 13. 1- TEST ALL NEW PIPING AS REQUIRED AT 250 P51G. 8- CONTRACTOR SHALL PROVIDE A COMPLETE SET OF SHOP DRAWINGS INCLUDING CALCULATIONS. 9- HEADS TO BE CENTERED IN TILES. GENERAL NOTES I- PROVIDE FIRE EXTINGUISHERS BY LARSENS MODEL No: MP -5, 2A -IOB:C RATED IN A SEMI RECESSED FIRE EXTINGUISHER CABINET BY LARSEN5 MODEL' AL- 2405 -R3, FULL GLASS FRONT W/ LARSEN LOCK I PER 2500 SF. ( 3 J SUBMIT SHOP DWGS FOR REVIEW, R F.E.: FIRE EXTINGUISHER BARRIER PARTITIONS AS REQUIRED ALONG WALLS AND WINDOWS. TYR NOTE: FIELD VERIFY AND MEASURE ALL EXISTING CONDITIONS NOTIFY ARCHITECT OF ANY DISCREPANCIES. PARTIAL FOURTH FLOOR PLAN SCALE: 3/16' =1' -0' FLOOR AREA: 10,340 S.F. (11,764 S.F. TOTAL FLOOR) PARTITION LEGEND P -I NEW 3 5/6' 25 GA METAL 5TUD5 a 14' OC W/ 5/8' GYP. BD a EACH SIDE. P -2 NEW 1 HR FIRE RATED PARTITION 3 5/8' 25 GA METAL 5TUD8 W/ 5/6' TYPE X GYP. BD a EACH SIDE. P -3 NEW 6' 25 GA METAL 5TUD5 a 24' OC W/ 5/6' GYP. BD a EACH SIDE. P -4 NEW - 3 5/6' 25 GA GYP. BD. a EACH SIDE W/ CORRIDOR/TENANT 51DE TO STRUCTURE ABOVE. P -5 NEW 6' 25 GA. METAL STUDS 0 24' OC W/ 5/8' GYP. BD a INTERIOR SIDE (FURR OUT WALL FOR PLUMBING). P -6 NEW 3 5/V25 GA METAL STUDS a 24' OC W/ 5/8' GYP. BO E SOUND BATT6 TO UNDERSIDE OF STRUCTURE, W -1 EXISTING 6' CONIC. BLOCK WALL W/ 5/8' GYP. BD OVER 1/6' FURRING. (STAIRWAY INTERIOR TO REMAIN UNFINISHED). W -2 EXISTING CONC COL W/ 5/8' GYP. BD OVER 1/8' FURRING. W -3 3'-0' HIGH MASONRY WINDOW WALL W/ 5/8 GYP. BD. OVER FURRING. 7430 sw 48th street miami, florida 33155 phone: (305) 663 -1970 fax: (305) 663 -2312 e —mail: peter (9diezarchitecture.com pedro diez, ra president or 0008996 ENGINEERING CONSULTANT 6747 Office Building 4th Floor 6141 SUNSET DRIVE SOUTH MIAMI, FLORIDA PROJECT No. 04- 158.04 REVISIONS 33 02 -02 -2006 FOURTH FLOOR PLAN CID