06-51-003C 100 ^I IT AC [Of•/V IICOCPY G ICG N IT AG OCN IICCn ACa1 v AOI' -= A
TENANT "I
VACANT TENANT *1
KEY PLAN N.T.S.
LINES TYPICAL.
MIN 18' CRA. ON PULL SIDE C
DOOR W/ MIN 12' a PUSH SIDE
TYPICAL AT ALL DOORS.
TYPICAL AT ALL WALL JOG!5
AND NICHES.
MIN OF 12' ON PUSH SIDE O=
TYPICAL AT ALL DOORS WITH
BOTH A CLOSER AND A LATCH.
DOOR ENTRY DETAIL 1/49
FIRE SPRINKLER GENERAL NOTES
I- OFFICES TO BE FULLY SPRINKLED. CONTRACTOR TO)
PROVIDE SHOP DRAWING5 FOR ARCHITECT'S REVIEW.
2- COORDINATE LOCATION OF SPRINKLER LINES AND
HEADS WITH OTHER TRADES.
3- COORDINATE HEIGHT OF SPRINKLES HEADS WITH
FINISHED CEILING HEIGHTS AS INDICATED ON THE
ARCHITECTURAL DRAWINGS.
4- MAXIMUM AREA AND DISTANCE COVERAGE PER
SPRINKLER HEAD SHALL BE AS SET FORTH BY NF.PA.
BULLETIN 13.
5- MINIMUM DISTANCE FROM SPRINKLER HEAD TO ANY
OBSTRUCTIVE ELEMENT SUCH AS LIGHT, AIR
015TRIBUTION DEVICES, ETC. SHALL BE AS SET FORTH
BY NF.PA. BULLETIN 13.
GLASS. PROVIDE BREAK METAL ON END TO
MATCH BUILDING STOREFRONT COLOR
TYPICAL is NON -SMOKE BARRIER PARTITIONS
WHERE SHOWN ON PLANS,
6- ALL PIPING SHALL BE AS 5ET FORTH BY NF.PA.
BULLETIN 13.
1- TEST ALL NEW PIPING AS REQUIRED AT 250 P51G.
8- CONTRACTOR SHALL PROVIDE A COMPLETE SET OF
SHOP DRAWINGS INCLUDING CALCULATIONS.
9- HEADS TO BE CENTERED IN TILES.
GENERAL NOTES
I- PROVIDE FIRE EXTINGUISHERS BY LARSENS
MODEL No: MP -5, 2A -IOB:C RATED IN A SEMI
RECESSED FIRE EXTINGUISHER CABINET BY
LARSEN5 MODEL' AL- 2405 -R3, FULL GLASS
FRONT W/ LARSEN LOCK I PER 2500 SF. ( 3 J
SUBMIT SHOP DWGS FOR REVIEW,
R F.E.: FIRE EXTINGUISHER
BARRIER PARTITIONS AS
REQUIRED ALONG WALLS
AND WINDOWS. TYR
NOTE: FIELD VERIFY AND MEASURE
ALL EXISTING CONDITIONS
NOTIFY ARCHITECT OF ANY
DISCREPANCIES.
PARTIAL FOURTH FLOOR PLAN
SCALE: 3/16' =1' -0'
FLOOR AREA: 10,340 S.F. (11,764 S.F. TOTAL FLOOR)
PARTITION LEGEND
P -I NEW 3 5/6' 25 GA METAL 5TUD5 a 14' OC W/ 5/8' GYP. BD a EACH SIDE.
P -2 NEW 1 HR FIRE RATED PARTITION 3 5/8' 25 GA METAL 5TUD8 W/ 5/6' TYPE X GYP. BD a EACH SIDE.
P -3 NEW 6' 25 GA METAL 5TUD5 a 24' OC W/ 5/6' GYP. BD a EACH SIDE.
P -4 NEW - 3 5/6' 25 GA GYP. BD. a EACH SIDE W/ CORRIDOR/TENANT 51DE TO STRUCTURE ABOVE.
P -5 NEW 6' 25 GA. METAL STUDS 0 24' OC W/ 5/8' GYP. BD a INTERIOR SIDE (FURR OUT WALL FOR PLUMBING).
P -6 NEW 3 5/V25 GA METAL STUDS a 24' OC W/ 5/8' GYP. BO E SOUND BATT6 TO UNDERSIDE OF STRUCTURE,
W -1 EXISTING 6' CONIC. BLOCK WALL W/ 5/8' GYP. BD OVER 1/6' FURRING. (STAIRWAY INTERIOR TO REMAIN UNFINISHED).
W -2 EXISTING CONC COL W/ 5/8' GYP. BD OVER 1/8' FURRING.
W -3 3'-0' HIGH MASONRY WINDOW WALL W/ 5/8 GYP. BD. OVER FURRING.
7430 sw 48th
street
miami, florida
33155
phone: (305)
663 -1970
fax: (305)
663 -2312
e —mail: peter (9diezarchitecture.com
pedro diez, ra
president or
0008996
ENGINEERING CONSULTANT
6747
Office Building
4th Floor
6141 SUNSET DRIVE
SOUTH MIAMI, FLORIDA
PROJECT No. 04- 158.04
REVISIONS
33 02 -02 -2006
FOURTH
FLOOR PLAN
CID