Loading...
06-51-002LEGAL DESCRIPTION LOTS 8 THROUGH 15, BLOCK 2, LESS THE SOUTH 21 FEET FOR RIGHT OF WAY DEDICATION OF 5W 12 ST, LARKIN CENTER ACCORDING TO THE PLAT THEREOF, AS RECORDED IN PLAT BOOK 21, PAGE 6l. AND LOT 5, BLOCK 2, ROSSWOOD ACCORDING TO THE PLAT THEREOF, AS RECORDED IN PLAT BOOK 13, PAGE 62, EXISTING BUILDING DATA 5 STORY CBS BLDG. WITH CONCRETE J015T FLOOR AND ROOF STRUCTURE AND CONCRETE INTERIOR COLUMNS. BLDG. TYPE- TYPE III I HR PROTECTED W/ FULLY AUTOMATIC FIRE SPRINKLER SYSTEM THROUGHOUT ENTIRE BLDG. FIRE RESISTANCE RATING- I HR FIRE RATING FOR STRUCTURAL ELEMENTS 4 FLOORS AND 2 HR FIRE PROTECTION FOR EXTERIOR WALLS AS PER FBC 2004 TABLE 601. OFFICES TO HAVE A FIRE ALARM SYSTEM AND AN AUTOMATIC FIRE SUPPRESSION SYSTEM. SW 61 AVE SW 61 CT (D SITE PLAN ZONING DISTRICT MU -4 / MU -5 SITE AREA 30,964 6F 33155 phone: (305) 663 -1970 BUILDING AREA 663 -2312 e —mail: peter ©diezarchitecture.com EXISTING GROUND FLOOR 9,121 $F EXISTING SECOND FLOOR 494 SF EXISTING THIRD FLOOR 11,181 SF EXISTING FOURTH FLOOR 11,164 SF EXISTING FIFTH FLOOR 10342 6F TOTAL 43,508 SF OFF STREET PARKING REQUIRED 129 SPACES EXISTING OFF STREET PAI;IKING PROVIDED 134 SPACES EXISTING ON STREET PARKING PROVIDED 1 SPACES AREA OF WORK FOURTH FLOOR 8,380 SF 1 :30 N W OC Z GENERAL NOTES 1.- CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS AND SHALL NOTIFY THE ARCHITECT IF ANY DISCREPANCIES ARE DISCOVERED BEFORE PROCEEDING WITH THE WORK 2.- CONTRACTOR TO ACQUIRE ALL REQUIRED PERMITS FOR THE CONSTRUCTION AND SUBSEQUENT OCCUPANCY OF PROJECT. 3.- ALL WORK DONE UNDER THE SUPERVISION OF THE CONTRACTOR SHALL BE DONE IN A NEAT AND WORKMAN -LIKE MANNER AND IN ACCORDANCE WITH ALL GOVERNING AGENCIES , RULES AND REGULATIONS HAVING JURISDICTION. 4.- CONTRACTOR TO PROVIDE ALL SUPPLEMENTARY MATERIALS REQUIRED TO INSTALL, SUPPORT, BRACE AND SHORE ALL BUILDING COMPONENTS. 5. -, PRIOR TO COMMENCING WORK, THE CONTRACTOR SHALL VERIFY THE LOCATION OF ALL EQUIPMENT AND UTILITIES TO BE REMOVED REMOVALS SHALL BE COORDINATED WITH THE OWNER AND ALL BUILDING AUTHORITIES HAVING JURISDICTION ro. -• CONTRACTOR SHALL PROVIDE THE ARCHITECT WITH RED -LINED AS BUILT DRAWINGS FOR ANY AND ALL FIELD CHANGES AND/ OR ADDITIONS TO THE WORK INCLUDED IN THE DRAWINGS. 1.- IF ANY CHANGES AND /OR DEVIATIONS ARE MADE TO THESE PLANS WITHOUT THE WRITTEN AUTHORIZATION OF THE ARCHITECT , THE CONTRACTOR SHALL BEAR FULL RESPONSIBILITY FOR SUCH CHANGES AND/ OR DEVIATIONS. 8.-• IF DURING THE COURSE OF CONSTRUCTION ANY DEVIATIONS ARE MADE AT THE FIELD, AGAIN, THE CONTRACTOR SHALL BEAR FULL RESPONSIBILITY FOR SUCH CHANGES AND / OR DEVIATIONS. 9.- ALL SHOP DRAWINGS SHALL BE SUBMITTED TO THE ARCHITECT FOR DE51GN CONFORMANCE ONLY 10.- SUBSTITUTIONS MUST BE REVIEWED AND APPROVED BY THE ARCHITECT OR ENGINEERS 11.- CONTRACTOR AND SUBCONTRACTORS SHALL BE RESPONSIBLE FOR CLEANING H15 OR HER OPERATION AND REPAIRING ANY DAMAGE TO HIS WORK WHILE PROJECT 15 UNDER UNDER CONSTRUCTION 12.- ALL WORK SHALL BE PERFORMED TO MEET AND COMPLY WITH A.D.A. 5TANDARD5 AND 2004 F.B.C. CHAPTER 11, F.A.C. 13.- ALL DESIGNS AND DRAWINGS HERE IN AND PRINTS ISSUED BY THE ARCHITECT ARE THE PROPERTY OF THE ARCHITECT AND SHALL NOT BE REUSED ON ANY OTHER LOCATION EXCEPT FOR THE ONE FOR WHICH THEY WERE EXPRESSLY DESIGNED . IF THESE DRAWINGS OR ANY PART THERE OF 15 REPRODUCED WITHOUT THE CONSENT OF THE ARCHITECT, THE PERSON 50 DOING WILL BE INDEBTED TO THE ARCHITECT FOR HIS FULL COMMISSION CONSTRUCTION NOTES 1. LOCATE EXIST SANITARY SEWER AND EXTEND AS REQUIRED FOR NEW SERVICES. 2. GENERAL CONTRACTOR SHALL PROVIDE ALL SHORING AND TEMPORARY SAFEGUARDS, DUST BARRIERS AND WARNING SIGNS AS REQUIRED. 3. GENERAL CONTRACTOR SHALL NOTIFY OWNER/ BLDG. MANAGER IN WRITING THREE DAYS PRIOR TO MAJOR ELECTRICAL OR MECHANICAL SHUTDOWN 4 REQUIRED DOWNTIME 50 THAT APPROPRIATE ACTION CAN BE TAKEN. 4. CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS 4 SHALL NOTIFY THE ARCHITECT IN WRITING OF ANY DISCREPANCIES. 5. ACTUAL EXISTING DIMENSIONS SHALL GOVERN. G. ALL DEBRIS TO BE DISPOSED OF BY CONTRACTOR.. ACCESSIBILITY NOTES 1. RESULTS OF THIS RENOVATION WILL NOT CREATE ANY ARCHITECTURAL BARRIERS (4.1ro /4.18 F.A.C). 2. ALL LEVELS ARE ACCE5515LE 3. ALL NEW DOORS ARE 2' -10' WIDE MIN, 32' CLEAR OPENING. 4. COMMON PATH OF TRAVEL, MAXIMUM LEVEL DIFFERENCE 1/2' SCOPE OF WORK WORK CON51845 OF THE INTERIOR BUILD OUT THE EXISTING VACANT SPACE, INCLUDED IN WORK ARE ELECTRICAL, PLUMBING, 14VAC DUCTWORK, FLOORING, CEILING, PARTITIONS AND PAINTING. SEE PLANS FOR EXTENT. dez 7430 sw 48th street miami, florida 33155 phone: (305) 663 -1970 fax: (305) 663 -2312 e —mail: peter ©diezarchitecture.com pedro diez, ra president or 0008996 ENGINEERING CONSULTANT ::::: G141 Office Building 4th Floor 6141 SUNSET DRIVE SOUTH MIAMI, FLORIDA PROJECT No. 04- 158.04 M. REVISIONS SITE PLAN 4 S, , sT r SCALE: AS SHOWN DATE: DECEMBER 12, 2005 AlGO