06-1828R-007
PANEL A TYPE : SQD -NQOD MAINS 400A M.L.O. W/ FEED THRU LUGS SECTION I MNT : FLUSH BUS 400A LOC : TENANT SPACE VOLTS 120/208, 3PHS, 4W FEEDER : 2 SETS OF 4 - #3/0, 2.0" A.I.C. 10,000 ELECTRICAL SYMBOL TABLE SYMBOL DESCRIPTION j� DUPLEX RECEPTACLE -MOUNT 18" A.F.F. UNLESS OTHERWISE NOTED ``��--�a'' 20 AMP /125 VOLT WIRE, C �-j DUPLEX RECEPTACLE - SWITCHED RECEPTACLE ``KK 20 AMP /125 VOLT AS PER PLANS j-j DUPLEX RECEPTACLE - VERIFY MOUNTING HEIGHT ��••••�{ 20 AMP /125 VOLT 1/20 1.50 G.F.I. RECEPTACLE - VERIFY MOUNTING HEIGHT 4 20 AMP /125 VOLT 30.00 013 DUPLEX RECEPTACLE - DEDICATED CIRCUIT, SEPARATE NEUTRAL 1/20 20 AMP /125 VOLT RUN #12 GROUND WIRE BACK TO PANEL 2 - #12, 1/2" DUPLEX RECEPTACLE - ISOLATED CIRCUIT, LEVITON ##5362 -IG I.G. 20 AMP /125 VOLT RUN #12 GROUND WIRE BA Ci< TO PANEL 7 QUAD RECEPTACLE -MOUNT 18" A.F.F. UNLESS OTHERWISE NOTED RECEPTACLES 20 AMP /125 VOLT 8 H.V.A.C. DUCT SMOKE DETECTORS SHALL BE INSTALLED AS PART OF THE SINGLE RECEPTACLE -MOUNT 18" A.F.F. UNLESS OTHERWISE NOTED 20 AMP /125 VOLT VOLTAGE AND AMPACITY AS PER PLANS 1.92 CLOCK HANGER RECEPTACLE - VERIFY MOUNTING HEIGHT 0C 15 AMP /125 VOLT 1.02 UGHTING EQUIPMENT RECEPTACLE -MOUNT 18" A.F.F. UNLESS OTHERWISE NOTED ® 208/240 VOLT VOLTAGE AND AMPACITY AS PER PLANS 3 - #12, 1/2" 12 SWITCH, SINGLE POLE -MOUNT 44" A.F.F. UNLESS OTHERWISE NOTED UGHTING 3 - #12. 1/2" 20 AMP /120 -277 VOLT 1/20 0.90 SWITCH, DOUBLE POLE -MOUNT 44" A.F.F. UNLESS OTHERWISE NOTED DP 20 AMP /120 -277 VOLT 0.93 LIGHTING SWITCH, THREE -WAY -MOUNT 44" A.F.F. UNLESS OTHERWISE NOTED 3 20 AMP /120 -277 VOLT RECEPTACLES 3 - #12, 1/2" SWITCH, FOUR -WAY -MOUNT 44" A.F.F. UNLESS OTHERWISE NOTED 4 20 AMP /120 -277 VOLT 3 - #12. 1/2" 17 1/20 SWITCH, DIMMER -SIZE DIMMER WITH TOTAL LAMP WATTAGE 3 - #12, 1/2" $ D 120 -277 VOLT 0.38 LIGHTING $R SWITCH, FAN DIMMER -SIZE DIMMER WITH TOTAL MOTOR LOAD 0.72 RECEPTACLES 120 VOLT RHEOSTAT SWITCH, MOTOR RATED -RATED FOR USE WITH TOTAL MOTOR LOADS M 20 AMP, 120 -277 VOLT 1/20 0.72 $K SWITCH, KEY -AS MANUFACTURED BY "LEVITON" 20 AMP, 120 -277 VOLT MODEL #1221 -2L / 55500 $0 SWITCH, OCCUPANCY SENSOR -AS MANUFACTURED BY "SENSOR SWITCH" IRECEPTACLES 20 AMP /120 -277 VOLT MODEL #WSD -1 3/25 LUTRON SMART SWITCH -AS MANUFACTURED BY " LUTRON" L 20 AMP /120 VOLT MODEL # 0 TELEPHONE OUTLET -MOUNT 18" A.F.F. UNLESS OTHERWISE NOTED 26 -EMPTY 3/4" EMT STUBBED ABOVE CEILING W/ BUSHING (HEAT) DATA /PHONE OUTLET -MOUNT 18" A.F.F. UNLESS OTHERWISE NOTED 1/20 1.00 -EMPTY 3/4" EMT STUBBED ABOVE CEILING W/ BUSHING O TELEPHONE JUNCTION BOX -EMPTY 1.25" EMT STUBBED ABOVE CEILING W/ BUSHING WALL MOUNT O DATA JUNCTION BOX -EMPTY 1.25" EMT STUBBED ABOVE CEIUNG W/ BUSHING RECEPTACLES WALL MOUNT UNLESS OTHERWISE NOTED. © POWER JUNCTION BOX - CONNECT TO ELECTRICAL PANEL AS PER PLANS 3 - #10. 1/2" WALL MOUNT 1/20 O JUNCTION TION BOX - VERIFY MOUNTING HEIGHT 32 5.00 rqP POWER POLE -SIZE AND HEIGHT TO MATCH CEILING REQUIREMENTS 1/20 0.54 DUAL CHANNEL FOR POWER AND DATA D DISCONNECT -SIZED AND FUSED AS PER EQUIPMENT NAMEPLATE RATING ®1 H.O.A. STARTER - VERIFY HEATER STRIP SIZE WITH EQUIPMENT ® MOTOR STARTER - VERIFY HEATER STRIP SIZE WITH EQUIPMENT VFD VARIABLE FREQUENCY - PROVIDED BY MECHANICAL CONTRACTOR 3 - #10. 1/2" DRIVE 1/20 ,v EXHAUST FAN /MOTOR -SEE MECHANICAL DRAWINGS FOR DETAILS LC LIGHTING CONTACTOR - VERIFY NUMBER OF POLES ❑K CARD READER / KEYPAD -EMPTY 3/4" EMT STUBBED ABOVE CEILING W/ BUSHING RI INTERCOM -EMPTY 3/4" EMT STUBBED ABOVE CEILING W/ BUSHING O DOME CAMERA IN CEIUNG -EMPTY 3/4" EMT STUBBED ABOVE CEILING W/ BUSHING �4 MONITOR CAMERA -EMPTY 3/4" EMT STUBBED ABOVE CEILING W/ BUSHING " ALARM CONTACTS 1 0.50 Q DOOR BUZZER 42 0 LOW VOLTAGE CEILING MOUNTED SPEAKERS r 7 DENOTES FLOOR OR ROOF MOUNT L PANEL A TYPE : SQD -NQOD MAINS : M.L.O. SECTION 11 MNT : FLUSH BUS : 400A LOC : TENANT SPACE VOLTS : 120/208, 3PHS, 4W FEEDER : 2 SETS OF 4 - #3/0, 2.0" A.I.C. : 10,000 IK L ( ^1 DENOTES CEIUNG MOUNT D SC TIO R C T kOZ=,, VA DENOTES CORD DROP DEVICE - VERIFY MOUNTING HEIGHT PANEL A TYPE : SQD -NQOD MAINS 400A M.L.O. W/ FEED THRU LUGS SECTION I MNT : FLUSH BUS 400A LOC : TENANT SPACE VOLTS 120/208, 3PHS, 4W FEEDER : 2 SETS OF 4 - #3/0, 2.0" A.I.C. 10,000 CKT POLE KVA DESCRIPTION WIRE, C CKT POLE KVA DESCRIPTION WIRE, C 1 1/20 1.20 REFRIGERATOR 2 - #12. 1/2"- 2 1/15 1.80 TUBE STAND 3 - #12. 1/2" 3 1/20 1.50 UTILITY OUTLET 2 - #12, 1/2" 4 3/100 30.00 X -RAY MACHINE 3 - #3 1.25" 5 1/20 1.50 1 UTILITY OUTLET 2 - #12, 1/2" 6 1 ® NEW RECEPTACLES TO BE INSTALLED IN COUNTER SPACE. VERIFY EXACT W/ #6 GND. 7 1/20 0.72 RECEPTACLES 3 - #12, 1/2" 8 H.V.A.C. DUCT SMOKE DETECTORS SHALL BE INSTALLED AS PART OF THE SHUNT TRIP 9 1/20 1.92 DEXA MACHINE 3 - #12. 1/2" 10 1/20 1.02 UGHTING 3 - #12, 1/2" 11 1/20 0.72 RECEPTACLES 3 - #12, 1/2" 12 1/20 1.28 UGHTING 3 - #12. 1/2" 13 1/20 0.90 RECEPTACLES 3 - #12, 1/2" 14 1/20 0.93 LIGHTING 3 - #12, 1/2" 15 1/20 0.72 RECEPTACLES 3 - #12, 1/2" 16 1/20 1.79 LIGHTING 3 - #12. 1/2" 17 1/20 0.90 RECEPTACLES 3 - #12, 1/2" 18 1/20 0.38 LIGHTING 3 - #12, 1/2" 19 1/20 0.72 RECEPTACLES 3 - #12, 1/2" 21 1/20 0.72 RECEPTACLES 3 - #12. 1/2' 22 j 23 1/20 1.08 IRECEPTACLES 3 - #12. 11/2 24 3/25 1.46 A.H.U. #1 3 - #10, 1/2" 25 1/20 0.54 RECEPTACLES 2 - #12. 1/2" 26 5.00 (HEAT) 27 1/20 1.00 RECEPTACLES 2 - #12. 1/2'/ 28 29 1/20 0.50 RECEPTACLES 2 - #12, 1/2'k 30 3/25 1.46 A.H.U. #2 3 - #10. 1/2" 31 1/20 0.90 RECEPTACLES 2 - #12. 1/2" 32 5.00 (HEAT) 33 1/20 0.54 RECEPTACLES 2 - #12. 112-64\ 34 35 1/20 1.00 COPIER 3 - #12, 1/2'k 36 3/25 1.46 A.H.U. #3 3 - #10. 1/2" 37 1/20 0.50 RECEPTACLES 2 - #12. 1/2' 38 5.00 (HEAT) 39 1/20 0.54 RECEPTACLES 2 - #12. 11/2" 40 41 1/20 1 0.50 IRECEPTACLES 2 - #12. 1/2'k 42 SUB -TOTAL 18.62 KVA SUB -TOTAL 56.24 KVA PANEL A TYPE : SQD -NQOD MAINS : M.L.O. SECTION 11 MNT : FLUSH BUS : 400A LOC : TENANT SPACE VOLTS : 120/208, 3PHS, 4W FEEDER : 2 SETS OF 4 - #3/0, 2.0" A.I.C. : 10,000 IK L P E KV D SC TIO R C T kOZ=,, VA DE RIP ON E. 43 44 SPACE 45 3/20 3.33 C.U. -1 3 - #10. 1/2" 46 SPACE 47 48 ISPACE 49 0 2 50 \3-A2. 2" 51 3/25 3.33 C.U. -2 3 - #10. 1/2" 2 1/20 1.50 SERVER 3 - #12, 1/2" 53 4 1/20 1.50 SERVER 3 - #12, 1/2" 55 6 1/20 0.50 T.T.B. 3 - #12, 1/2" 57 3/25 4.78 C.U. -3 3 - #10, 1/2" 8 1/20 1.08 RECEPTACLES 3 - #12. 1/2" 59 0 1/20 0.50 RECEPTACLE 3 - #12. 1/2 . 61 SPACE 2 2/80 14.04 PANEL 'Al' 3 - #4, 1.25" 63 SPACE 4 65 SPACE 6 1/20 0.40 CONDENSATE PUMPS 2 - #12, 1/2" 67 PAC 68 SPACE 69 SPACE 70 SPACE 71 SPACE 72 SPACE 73 SPACE 74 SPACE 75 SPACE 76 SPACE 77 SPACE 78 SPACE 79 SPACE 80 SPACE 81 SPACE 82 SPACE 83 SPACE 84 SPACE TOTAL 30.06 KVA TOTAL 77.26 KVA 107.32 KVA - TOTAL CONNECTED LOAD 1.67 KVA - 25% OF CONTINUOUS LOAD 97.55 KVA - TOTAL DEMAND LOAD (HEATING AND COOUNG LOADS ARE NON- CONCURRENT) 97.55 KVA / 208 X r3- = 271.0 AMPS PANEL Al TYPE : SOD-NQOD MAINS M.L.O. MNT : FLUSH BUS 1ODA LOC : TENANT SPACE VOLTS 120/208, 1PHS. 4W FEEDER : 3 - #4, 1.25" A.I.C. 10,000 CKT POLE KVA DESCRIPTION WIRE, C CKT POLE KVA DESCRIPTION WIRE, C 1 1/20 2.40 TABLE 3 - #12, 1/2" 2 1/15 1.80 TUBE STAND 3 - #12. 1/2" 3 1/15 1.80 GENERATOR 3 - #12, 1/2" 4 1/15 1.80 WALL STAND 3 - #12. 1/2" 5 2/30 6.24 SPARE EXISTING FUTURE FLOOR SPACE. NO ELECTRICAL WORK TO BE PERFORMED IN 6 THIS AREA UNDER THIS PERMIT AND /OR CONTRACT DOCUMENTS. ® NEW RECEPTACLES TO BE INSTALLED IN COUNTER SPACE. VERIFY EXACT ' 7 INSTALLATION. COORDINATE ALL WORK WITH MILLWORK DRAWINGS AND 1 DETAILS PROVIDED BY THE ARCHITECT AND /OR MILLWORK CONTRACTOR. 8 H.V.A.C. DUCT SMOKE DETECTORS SHALL BE INSTALLED AS PART OF THE EXISTING FIRE ALARM SYSTEM. DETECTORS SHALL BE INSTALLED BY 9 1 CONTRACTOR. COORDINATE ALL FIRE ALARM WORK WITH THE BUILDING FIRE ALARM MAINTENANCE CONTRACTOR. 10 NEW FIRE ALARM DEVICES SHALL BE INSTALLED TO MATCH EXISTING. CONNECT INITIATING AND SIGNALING DEVICES TO EXISTING ZONE(S). COORDINATE ALL 11 11 FIRE ALARM SHOP DRAWINGS, SIGNED AND SEALED, AS REQUIRED BY THE JURISDICTION HAVING AUTHORITY SHALL BE PROVIDED BY THE FIRE ALARM 12 CONTRACTOR AND THEIR OWN RESPECTIVE ENGINEER. 1© ALL ELECTRICAL WIRING IN TREATMENT ROOMS SHALL CONFORM WITH N.E.C., TOTAL 10.44 KVA TOTAL 3.60 KVA 14.04 KVA - TOTAL CONNECTED LOAD 14.04 KVA / 208 = 67.5 AMPS FOURTH FLOOR ALL SWITCHGEAR. BOXES, DEVICES, CONDUIT AND WIRE INDICATED ON THIS PLAN BY A DASHED LINE ARE EXISTING TO REMAIN. ALL DOTTED LINES INDICATE EXISTING EQUIPMENT TO BE REMOVED OR REPLACED. ALL SWITCHGEAR, BOXES, DEVICES, CONDUIT AND WIRE INDICATED ON THIS PLAN BY A I. SOUD UNE ARE NEW. SECOND FLOOR FIRST FLOOR PANEL PANEL PANEL DISC. • 'A' 'A' 'A1' _ too 400A 100A 3 100 MLO MLO SEC. I SEC. II 1 PHASE FIELD VERIFY EXISTING CHASE AND OR CONDUITS FROM SECOND FLOOR ELECTRIC ROOM TO THIS TENANT. rISC1. I ols C.] J DISC. L�J LJ 3 1 `� I 6 Q 400A K -7 METER CAN 1 C .� r•3 fir• ,� � ti diezr r hit a c e�e,.�1< . inc, 7430 sw 48th street miami, florida 33155 Y phone: (305) 663 - 197;.•. •;,,r fax: (305) 663 -231,2 e -mail: peter®diezarchiteiture.coXq, •, pedro diez, ra ter' rf,< president or 0008996 ENGINEERING CONSULTANT 6. ".J Puga and Associates, Inc. Engineers /Consultants J # EB 0005813 7326 S.W. 48th Street - • ,rs,:,,� Miami, Florida 33155 4% (305) 661 -7700 J „ A i R!� 09 Itb jq" . ..... Oa M st 4 .'R.a 4th FLOOR 6141 SUNSET DRIVE SOUTH MIAMI, FLORIDA PROJECT No. 04.158.041 1% REVISIONS 01 03/13/07 Owner Re�Tsion .1 �1 •1r 1 NUMBERED ELECTRICAL NOTES O1 PRIOR TO BID, THE CONTRACTOR SHALL VISIT THE JOB SITE AND BECOME FAMIUAR WITH ALL EXISTING CONDITIONS. NOTIFY THE ARCHITECT OR 1 ENGINEER OF ANY DISCREPANCIES. THE CONTRACTOR SHAD_ QUALIFY THE BID WIRE IN 2.0 C W / #3 CU GND EACH ACCORDINGLY. O2 SUBMIT SHOP DRAWINGS FOR ACCEPTANCE BY THE ARCHITECT AND /OR NEW 3 - #4 THWN CU WIRE IN 1.25" ENGINEER BEFORE PROCEEDING WITH THE PURCHASE OR INSTALLATION OF 1sT. ZTLI THE EQUIPMENT AND MATERIALS. O3 THE DESIGNATED NUMBERS ARE SHOWN ON THESE PLANS AS PER THE C W /#6 CU GND ORIGINAL DOCUMENTS FOR THE EXISTING PANEL AND ARE FOR IDENTIFICATION ONLY. CONTRACTOR SHALL SHOW THE CIRCUIT NUMBERS ACTUALLY USED IN EXISTING 2 SETS OF 4 -#600 MCM THE INSTALLATION ON THE "AS- BUILT' DRAWINGS. ® MAINTAIN FIRE RATING IN ALL PENETRATIONS THRU DEMISING AND FIRE RATED I WALLS. O5 REPORT ANY DISCREPANCIES TO THE ARCHITECT OR ENGINEER PRIOR TO BID. © CONNECT EXIT AND EMERGENCY LIGHTS AHEAD OF SWITCH LEG ON EACH EXISTING 2 SETS 4 - #1 MCM THWN UGHTING CIRCUIT AS PER PLANS. ' O7 EXISTING FUTURE FLOOR SPACE. NO ELECTRICAL WORK TO BE PERFORMED IN THIS AREA UNDER THIS PERMIT AND /OR CONTRACT DOCUMENTS. ® NEW RECEPTACLES TO BE INSTALLED IN COUNTER SPACE. VERIFY EXACT ' LOCATION AND MOUNTING HEIGHT OF EACH DEVICE PRIOR TO ROUGH INSTALLATION. COORDINATE ALL WORK WITH MILLWORK DRAWINGS AND 1 DETAILS PROVIDED BY THE ARCHITECT AND /OR MILLWORK CONTRACTOR. O9 H.V.A.C. DUCT SMOKE DETECTORS SHALL BE INSTALLED AS PART OF THE EXISTING FIRE ALARM SYSTEM. DETECTORS SHALL BE INSTALLED BY MECHANICAL CONTRACTOR AND FURNISHED AND WIRED BY ELECTRICAL 1 CONTRACTOR. COORDINATE ALL FIRE ALARM WORK WITH THE BUILDING FIRE ALARM MAINTENANCE CONTRACTOR. �A L� 10 NEW FIRE ALARM DEVICES SHALL BE INSTALLED TO MATCH EXISTING. CONNECT INITIATING AND SIGNALING DEVICES TO EXISTING ZONE(S). COORDINATE ALL WORK WITH THE BUILDING FIRE ALARM MAINTENANCE CONTRACTOR. 11 FIRE ALARM SHOP DRAWINGS, SIGNED AND SEALED, AS REQUIRED BY THE JURISDICTION HAVING AUTHORITY SHALL BE PROVIDED BY THE FIRE ALARM CONTRACTOR AND THEIR OWN RESPECTIVE ENGINEER. 1© ALL ELECTRICAL WIRING IN TREATMENT ROOMS SHALL CONFORM WITH N.E.C., ARTICLE 517, SECTION II. 13 ALL ELECTRICAL WIRING IN X -RAY ROOMS SHALL CONFORM WITH N.E.C., ARTICLE 517, SECTION V. 14 FIELD VERIFY EXISTING CHASE OR CONDUITS TO PROVIDE ELECTRICAL 1 SERVICE TO THIS TENANT. 15 INSTALL NEW 2.0" CONDUIT FOR TELEPHONE. EXTEND CONDUIT OVERHEAD TO NEW T.T.B. FROM EXISTING TELEPHONE ROOM ON THIRD FLOOR LOCATION 16 ALL WORK SHALL CONFORM TO THE FLORIDA BUILDING CODE AND ALL OTHER APPUCABLE STATE AND LOCAL REGULATIONS AND ORDINANCES. 1© CONTRACTOR SHALL WARRANT ALL WORK TO BE FREE OF DEFECT IN WORKMANSHIP AND MATERIALS FOR A PERIOD OF ONE YEAR AFTER ACCEPTANCE OF THE PROJECT. 18 VERIFY EXACT LOCATION OF ALL EQUIPMENT WITH TENANT PRIOR TO ROUGH INSTALLATION. FOURTH FLOOR ALL SWITCHGEAR. BOXES, DEVICES, CONDUIT AND WIRE INDICATED ON THIS PLAN BY A DASHED LINE ARE EXISTING TO REMAIN. ALL DOTTED LINES INDICATE EXISTING EQUIPMENT TO BE REMOVED OR REPLACED. ALL SWITCHGEAR, BOXES, DEVICES, CONDUIT AND WIRE INDICATED ON THIS PLAN BY A I. SOUD UNE ARE NEW. SECOND FLOOR FIRST FLOOR PANEL PANEL PANEL DISC. • 'A' 'A' 'A1' _ too 400A 100A 3 100 MLO MLO SEC. I SEC. II 1 PHASE FIELD VERIFY EXISTING CHASE AND OR CONDUITS FROM SECOND FLOOR ELECTRIC ROOM TO THIS TENANT. rISC1. I ols C.] J DISC. L�J LJ 3 1 `� I 6 Q 400A K -7 METER CAN 1 C .� r•3 fir• ,� � ti diezr r hit a c e�e,.�1< . inc, 7430 sw 48th street miami, florida 33155 Y phone: (305) 663 - 197;.•. •;,,r fax: (305) 663 -231,2 e -mail: peter®diezarchiteiture.coXq, •, pedro diez, ra ter' rf,< president or 0008996 ENGINEERING CONSULTANT 6. ".J Puga and Associates, Inc. Engineers /Consultants J # EB 0005813 7326 S.W. 48th Street - • ,rs,:,,� Miami, Florida 33155 4% (305) 661 -7700 J „ A i R!� 09 Itb jq" . ..... Oa M st 4 .'R.a 4th FLOOR 6141 SUNSET DRIVE SOUTH MIAMI, FLORIDA PROJECT No. 04.158.041 1% REVISIONS 01 03/13/07 Owner Re�Tsion .1 �1 •1r 1 PARTIAL RISER N.T.S. �' R I r� •l^ SCALE: AS SF$)WN .Tr DATE: October 9 :ej(°! w �.• ik,� '' >I: ' • •¢ ._ � ;:,'tom ' K• I ELECTRICAL FEEDER SCHEDULE 1 NEW 2 SETS OF 4 - #3/0 THWN CU WIRE IN 2.0 C W / #3 CU GND EACH 2 NEW 3 - #4 THWN CU WIRE IN 1.25" C W /#6 CU GND 1sT. ZTLI 3 NEW 3 - #3 THWN CU WIRE IN 1.25" C W /#6 CU GND 4 EXISTING 2 SETS OF 4 -#600 MCM THWN CU WIRE IN 4.0" C W / #1/0 CU GND EACH - D_ 7] I 5 EXISTING 4 - #1 MCM THWN CU WIRE IN 2.0" C W /#6 CU GND - -t 6 EXISTING 2 SETS 4 - #1 MCM THWN CU WIRE IN 2.0" C W / #4 CU GND 1.71 J I I I I PARTIAL RISER N.T.S. �' R I r� •l^ SCALE: AS SF$)WN .Tr DATE: October 9 :ej(°! w �.• ik,� '' >I: ' • •¢ ._ � ;:,'tom ' K•