06-1828R-005GENERAL ELECTRICAL NOTES — ALL ELECTRICAL WORK PERFORMED UNDER THIS CONTRACT SHALL COMPLY WITH LOCAL CODES AND ORDINANCES AND ALL STANDARDS OF CONSTRUCTION ESTABLISHED BY THE LANDLORD. — SUBMIT SHOP DRAWINGS FOR ACCEPTANCE BY THE ARCHITECT AND /OR ENGINEER BEFORE PROCEEDING WITH THE PURCHASE OR INSTALLATION OF THE EQUIPMENT AND MATERIALS. NO FACSIMILES OR FACSIMILE COPIES SHALL BE ACCEPTED. — ALL CONDUCTORS SHALL BE THW OR THWN COPPER. ALL EXPOSED CONDUITS SHALL BE RUN AS NEAT AS POSSIBLE. P.V.C. CONDUIT SHALL ONLY BE USED IN SLAB OR UNDERGROUND AT A MINIMUM DEPTH OF 24 INCHES. — ALL DEDICATED OUTLETS SERVING EQUIPMENT SUCH AS REFRIGERATORS, WATER COOLERS, COPIERS, FAXES, ETC. SHALL HAVE SEPARATE NEUTRAL CONDUCTORS TO EACH DEVICE OR APPLIANCE. — FLEXIBLE CONDUIT SHALL BE USED FOR CONNECTION TO ALL VIBRATING EQUIPMENT SUCH AS MOTORS, ETC. — ALL WIRING DEVICES SHALL BE LEVITON COMMERCIAL GRADE (WHITE DECORA) OR EQUAL AS APPROVED BY ARCHITECT OR ENGINEER. — ALL RECEPTACLES SHALL BE INSTALLED AT 18" A.F.F. UNLESS OTHERWISE NOTED. — ELECTRICAL POWER AND CONTROL WIRING FOR H.V.A.C. AND MECHANICAL EQUIPMENT SHALL BE FURNISHED AND INSTALLED BY THE ELECTRICAL CONTRACTOR. — ELECTRICAL CONTRACTOR SHALL VERIFY THE CEILING FINISHES AND SUSPENSION SYSTEMS FOR SELECTION OF THE PROPER TRIM AND SUPPORT ARRANGEMENTS OF THE FIXTURE. — ELECTRICAL CONTRACTOR SHALL COORDINATE HIS WORK WITH THE ARCHITECT BEFORE ROUGH INSTALLATION OF LIGHTS, RECEPTACLES, SWITCHES AND EQUIPMENT FOR EXACT LOCATION. — ALL ELECTRICAL EQUIPMENT SHALL BE APPROVED AS SAFE FOR USE IN THE U.S. WORKPLACE, AS PER A "NRTL" RECOGNIZED ORGANIZATION. (U.L., C.S.A., ETC.) — ALL BRANCH CIRCUITS SHALL BE SIZED IN ACCORDANCE WITH N.E.C. 210 -19 REGARDLESS OF SIZES SHOWN ON PLANS OR PANEL SCHEDULES. — PROVIDE EXPANSION JOINTS WHERE REQUIRED AS PER N.E.C. 300 -7(b). — ALL UNDERGROUND CONDUIT INSTALLATIONS SHALL COMPLY WITH N.E.C., TABLE 300 -5. — IF ANY COF +LICT IS ENCOUNTERED WITHIN THE DESIGN DOCUEMNTS, REGARDLESS OF TRADE OR RESPONSIBILITY, THE GREATER SCOPE OF WORK SHALL PREVAIL. 0 ELECTRICAL POWER PLAN VERIFY WITH OWNER CABLE TYPE TO BE INSTALLED BETWEEN CPU'S AND DISPLAY MONITORS FOR THE DIGITAL X —RAY SYSTEM IN PATIENT CARE ROOMS. ENSURE CONDUITS FOR DATA DROPS ARE LARGE ENOUGH TO ACCEPT THESE CABLES. VERIFY EXACT MOUNTING HEIGHT PRIOR TO INSTALLATION. VERIFY ALL DETAILS FOR THE X —RAY ROOM AND EQUIPMENT PRIOR TO INSTALLATION. CONTACT CARLOS VELOSO OF DIEZ ARCHITECTURE INC. 3/16n THE OWNER HAS REQUESTED THAT PHONE LINES ONLY BE INSTALLED WHERE THE PHONE SYMBOLS DENOTE. THE DATA SYMBOLS DENOTE LOCATIONS FOR INSTALLATION OF DATA CABLING. diez archit inc. ecture, 7430 sw 48th street miami, florida 33155 phone: (305) 663 -1970 fax: (305) 663 -2312 e —mail: peter®diezarchitecture.com pedro diez, ra president ar 0008996 ENGINEERING CONSULTANT Puga and Associates, Inc. Engineers /Consultants # EB 0005813 7326 S.W. 48th Street Miami, Florida 33155 (305) 661 -7700 `l�tt. jq" elmm 4th FLOOR 6141 SUNSET DRIVE SOUTH MIAMI, FLORIDA PROJECT No. 04.158.041 REVISIONS &1 03/13/07 Owner Revision SCALE: AS SHOWN DATE: October 9, 2006 E -1 1 200 LnAul`,.b:. SCALE: AS SHOWN DATE: October 9, 2006 E -1