Loading...
06-1828R-004LEGEND ABV ABOVE CD CEILING DIFFUSER CFM CUBIC FEET PER MINUTE CLG. CEILING CONN CONNECT, CONNECTION DB DRY BULB DDC DIRECT DIGITAL CONTROL DI DIGITAL INPUT DN DOWN DP DIFFERENTIAL PRESSURE DR DRAIN DWG DRAWING EA. EACH ENT ENTERING EQUIP EQUIPMENT GA. GAUGE GALV. GALVANIZED HTR. ELECTRICAL HEATER HP HORSEPOWER KW KILOWATTS IN INCHES MAX. MAXIMUN MIN MINIMUN No. NUMBER NTS NOT TO SCALE 0/A OUTSIDE AIR P.D. PRESSURE DROP PSF POUND PER SQUARE FOOT QTY QUANTITY R/A RETURN AIR RPM REVOLUTIONS PER MINUTE RTU ROOFTOP UNIT S/A SUPPLY AIR S.P. STATIC PRESSURE SPS STATIC PRESSURE SENSOR TEMP. TEMPERATURE TRF TRANFER TS TEMPERATURE SENSOR TYP. TYPICAL UC UNDERCUT UP UP VAV VARIABLE AIR VOLUME VD MANUAL VOLUME DAMPER VEL VELOCITY VVT VARIABLE VOLUME AND TEMPERATURE V /PH VOLTAGE /PHASE WB WET BULB - - -� DASHED LINES DEPICT EXISTING 0.8 DUCTWORK / DEVICES TO REMAIN. BRANCH TAKEOFF WITH 450 SHOE FITTING WITH MANUAL VOLUME DAMPER. DUCT ELBOW WITH DOUBLE THICKNESS TURNING VANES CJOCXXXX)• FLEXIBLE ROUND DUCT. INSIDE DIMENSIONS. 1 -- ®-- SUPPLY AIR, CEILING MOUNTED REGISTER RETURN AIR, CEILING MOUNTED REGISTER DIFFUSER GRILLE TAG WITH REQUIRED O560 AIR VOLUME. SEE SCHEDULE FOR SIZES CFM AND THROW PATTERN. DIAMETER O T� ROOM THERMOSTAT OR THERMIDISTAT. 1 NUMBER NEXT TO SYMBOL DENOTES A/C UNIT MARK. FD FIRE DAMPER, EQUAL TO AIR BALANCE INC., A MODEL 119C, LEAKAGE CLASS II. SIZE DAMPER AS REQUIRED TO MAINTAIN SAME FREE AREA AS DUCT. VD MANUAL VOLUME DAMPER SD DUCT MOUNTED SMOKE SENSOR HVAC DESIGN REQUIRES: YES NO DUCT SMOKE DETECTOR AHU -2 AHU -3 FIRE DAMPER(S) CEILING e -mail: peter®diezarchitecture.com SMOKE DAMPER(S) WAITING ROOD SYSTEM /AREA SERVED FIRE RATED ENCLOSURE 0008996 FIRE RATED ROOF FLOOR CEILING ASSEMBLY MANUFACTURER COOK FIRE STOPPING TRANE = - - - - - SMOKE CONTROL GC -140 MODEL NUMBER J EXHAUST FAN SCHEDULE MARK EF -1,2 AHU -1 AHU -2 AHU -3 LOCATION CEILING e -mail: peter®diezarchitecture.com AREA SERVED WAITING ROOD SYSTEM /AREA SERVED RESTROOMS 0008996 MANUFACTURER COOK TRANE TRANE = - - - - - MODEL NUMBER GC -140 MODEL NUMBER TWEO49E13FB TWEO49E13FB WEIGHT (LBS) APPROX. 18 NOMINAL TONS SYSTEM TYPE EXHAUST 5.0 DESIGN CFM SETTING 75 14.00 14.00 13.50 E.S.P. (IN WATER) 0.25 TOTAL AIR SUPPLY CFM 1,490 FAN TYPE CENTRIFUGAL FAN RPM 1,058 200 280 MOTOR SIZE HP 43 WATTS ELECTRICAL SERVICE 115/1/60 z DRIVE TYPE DIRECT CONTROL FSC 5 1,230 1,310 1,360 SONE RATING (MAX.) 1.9 c� BACKDRAFT DAMPER MODEL No. 100 SERIES z ACCESSORIES /REMARKS GEMINI ISO KIT 0 EXTERNAL STATIC PRESSURE I.W.G. 0.6 0.6 0.8 z NOTES: 1 FANS LOCATED ON THE EXTERIOR OF THE BUILDING SHALL BE CONSTRUCTED AND INSTALLED TO WITHSTAND A WIND PRESSURE OF FROM ANY DIRECTION AS PER F.B.C. 2 ALL FANS SHALL HAVE UL APPROVED LOCAL DISCONNECT MEANS, SUPPLIED BY ELECTRICAL CONTRACTOR. 3 ROOF FANS AND VENTS SHALL HAVE BACK -DRAFT DAMPERS AND BIRD SCREENS. 4 FANS SHALL BE OF WELDED CONSTRUCTION UTILIZING CORROSION RESISTANT FASTENERS. ALL STEEL FAN COMPONENTS SHALL HAVE A SUPERFICIAL ELECTROSTATIC COATING TREATMENT TO PREVENT CORROSION. 5 MOTORS SHALL BE HEAVY DUTY TYPE WITH PERMANENTLY LUBRICATED SEALED BALL BEARINGS AND FURNISHED TO THE SPECIFIED VOLTAGE, PHASE AND ENCLOSURE. 6 FAN SHALL BE OF AN AMERICAN MANUFACTURER AND MANUFACTURED AT AN ISO 9001 CERTIFIED FACILITY. 7 ALL FAN SHALL BEAR AMCA CERTIFIED RATING AND UL LISTING. 8 FANS EF -1 AND 2 SHALL BE SWITCHED BY LIGHTS. --- - - ----- A/C EQUIPMENT SCHEDULE street UNIT DESIGNATION AHU -1 AHU -2 AHU -3 fax: (305) 663 -2312 e -mail: peter®diezarchitecture.com AREA SERVED WAITING ROOD OFFICES OFFICES 0008996 UNIT MANUFACTURER TRANE TRANE TRANE = - - - - - . L _ISYytm dL L.� MODEL NUMBER TWEO49E13FB TWEO49E13FB TWE065EIYB NOMINAL TONS 4.0 4.0 5.0 SYSTEM (S)EER 14.00 14.00 13.50 TOTAL AIR SUPPLY CFM 1,490 1,510 1,640 OUTSIDE AIR CFM 260 200 280 z RETURN AIR CFM 1,230 1,310 1,360 c� z 0 EXTERNAL STATIC PRESSURE I.W.G. 0.6 0.6 0.8 z = FAN SIZE HP 3/4 3/4 3/4 a FAN MOTOR FLA AMP 7.0 7.0 7.0 ENTERING AIR TEMPERATURE (DB /WB)° F 79.3 66.7 779 64.0 79'1 65.5 LEAVING AIR TEMPERATURE (DB /WB)° F 0 56.0 %8 53.1 55.5 54.0 TOTAL COOLING COIL CAPACITY MBH 46.9 49.0 56.5 TOTAL SENSIBLE CAPACITY MBH 33.0 38.9 41.7 TOTAL HEATING CAPACITY MBH 12.3 12.3 12.3 ELECTRIC HEATER SIZE (230 V) Kw 5 5 5 HEATER MCA / MOCP AMP 24 24 24 25 25 25 ELECTRICAL CHARACTERISTICS V /O /Hz 208/1/60 208/1/60 208/1/60 WEIGHT lbs. 196 196 196 DIMENSIONS (HxWxD) INCH 63x26x21 63x26x21 63x26x21 UNIT DESIGNATION CU -1 CU -2 CU -3 UNIT MANUFACTURER TRANE TRANE TRANE MODEL NUMBER 2TTA3048A3000A 2TTA3048A3000A 2TTA3060A3000A LOCATION ROOF ROOF ROOF Fz AMBIENT TEMPERATURE ° F 95 95 95 z z REFRIGERANT R 22 22 22 0 v COMPRESSOR MOTOR RLA AMP 11.6 11.6 17.3 0 w o FAN MOTOR SIZE HP 1/6 1/6 1/5 0 o: FAN MOTOR FLA AMP 1.4 1.4 1.2 a MCA / MOCP AMP 16 16 23 25 25 40 ELECTRICAL CHARACTERISTICS V /O /Hz 208/3/60 208/3/60 208/3/60 WEIGHT lbs. 267 267 256 DIMENSIONS (HxWxD) INCH 410704 410704 41x37x34 NOTES: 1 ALL UNITS SHALL BE HORIZONTALLY MOUNTED WITH TOP SUPPLY AND BOTTOM RETURN AS INDICATED ON DRAWINGS. 2 SIZE REFRIGERATION PIPING AS PER MANUFACTURER RECOMMENDATIONS. OVERSIZE LINES AS REQUIRED TO COMPENSATE FOR LINE LOSS WITH MINIMUM CAPACITY REDUCTION. SUBMIT SHOP DRAWINGS. 3 AIR HANDLING UNIT SHALL CONTAIN SOLID STATE INTERLOCK BOARD WITH BUILT IN FUSE AND TIME DELAY RELAY. 4 PROVIDE 5 YEAR WARRANTY ON ALL REFRIGERATION COMPONENTS. 5 PROVIDE ALL RELAYS, TRANSFORMERS, ETC. AS REQUIRED FOR COMPLETE OPERATING SYSTEM. 6 UNITS SHALL BE PROVIDED WITH A 4 INCH THICK PLEATED FILTER WITH A 30% MINIMUM EFFICIENCY. UNIT CONSTRUCTION AND INSTALLATION SHALL GUARANTEE AN EASY ACCESS TO FILTER SECTION FOR PROPER FILTER INSPECTION AND REPLACEMENT. 7 UNIT INSULATION AND ADHESIVE SHALL COMPLY WITH NFPA 90A REQUIREMENTS FOR FLAME SPREAD AND SMOKE GENERATION. INSULATION SHALL CONTAIN AN EPA REGISTERED IMMOBILIZED ANTI - MICROBIAL AGENT TO EFFECTIVELY RESIST THE GROWTH OF BACTERIA AND FUNGI IN ACCORDANCE WITH ASTM STANDARDS G21 AND G22. 8 FAN MOTOR SHALL BE HIGH EFFICIENCY TYPE. 9 FAN AND MOTORS SHALL BE PROVIDED WITH CIRCUIT PROTECTION. 10 CONDENSATE DRAIN PANS SHALL BE INSULATED AND SLOPED TO OUTLET. PANS SHALL HAVE STAINLESS STEEL LINERS. PROVIDE A OVERFLOW DETECTION SYSTEM CAPABLE OF SHUTDOWN THE UNIT UPON DECTTON OF HIGH LEVELS CONDENSATE DRAIN. 11 SUPPORT UNIT HIGH ENOUGH ABOVE CEILING TO ACCOMMODATE CONDENSATE DRAIN TRAPS IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS. 12 THE FAN DRIVE SHALL BE SELECTED FOR 125% OF THE MOTOR RATED HORSEPOWER. 13 CONTRACTOR SHALL GUARANTEE ADECUATE CLEARANCE ALL AROUND THE UNIT FOR MAINTENANCE ACCESS. 14 CONDENSING UNIT SHALL BE INSTALLED TO WITHSTAND WIND PRESSURE FROM ANY DIRECTION AS PER THE "HVHZ" REQUIREMENTS OF THE F.B.C. 15 ALL UNITS SHALL BE OF DOUBLE WALL CONSTRUCTION. ALL UNITS SHALL BE PROVIDED WITH ADEQUATE INSULATION. PROVIDE INSULATION LINERS TO PREVENT SURFACE CONDENSATION UNDER ALL CONDITIONS. 16 ALL UNITS SHALL HAVE A STAINLESS STEEL, DOUBLE SLOPED DRAIN PAN WITH INSULATION LINERS IN ACCORDANCE WITH ASHORE 62. 17 UNITS SHALL BE OF AMERICAN MANUFACTURER, DESIGNED AND RATED IN ACCORDANCE WITH ALL APPLICABLE ASHRAE, AIR AND NFPA CODES AND STANDARDS AND SHALL BE UL LISTED. 18 CONDENSER COILS SHALL BE PROVIDED WITH A PROTECTIVE GUARD. 19 ALL UNITS SHALL BE PROVIDED WITH A 2 -STAGE PROGRAMMABLE, DIGITAL THERMOSTAT WITH DEHUMIDIFICATION CONTROL EQUAL TO HONEYWELL MODEL No. TH8321U1006 AND SHALL BE CAPABLE OF PROVIDING AFTER HOURS SET BACK FOR ENERGY CONSERVATION PURPOSES. 20 DUCT MOUNTED SMOKE DETECTOR FOR ALL UNITS SHALL BE PROVIDED AND INSTALLED BY MECHANICAL CONTRACTOR AND WIRED BY FIRE ALARM CONTRACTOR. i c diez architecture inc. 7430 sw 48th street miami, florida 33155 phone: (305) 663 -1970 fax: (305) 663 -2312 e -mail: peter®diezarchitecture.com ^ pedro diez, ro president ar 0008996 ENGINEERING CONSULTANT Puga and Associates, Inc. Engineers /Consultants # EB 0005813 7326 S.W. 48th Street Miami, Florida 33155 (305) 661 -7700 1�. IT. jq" elf cea 4th FLOOR 6141 SUNSET DRIVE SOUTH MIAMI, FLORIDA PROJECT No. 04.158.041 REVISIONS ,1 03/13/07 Owner Revision SCALE: AS SHOWN DATE: October 9, 2006 M -3 �,•, t: ^ } I, . r� ( r MA '•t I . L _ISYytm dL L.� SCALE: AS SHOWN DATE: October 9, 2006 M -3