Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
06-1828-016
FIRE RATED ASSEMBLY 9/32 "0 GALVANIZED STEEL PIVOT ROD OF RIVET. FIRE DAMPER TYPE "B" - ALTERNATE ACCESS DOOR VEM LOCATION FUSIBLE LINK. "S" JOINT COLLAR TO DUCT. (TYPICAL TO BOTH SIDES OF FIRE DAMPER.) 16 GAUGE STEEL SLEEVE NOTE: 1. SLEEVE TO BE 16 GAUGE THROUGH 36 "x24" AN 14 GAUGE ON ALL LARGER SIZES. 2. FIRE DAMPER INSTALLATION SHALL MEET U.L. REQUIREMENTS. GALVANIZED SLEEVE (SEE NOTE) FIRE RETARDANT ROPE PACKING ONE PIECE ROLL FORMED GALVANIZED STEEL FRAME BLADE LOCK ACCESS DOOR STAINLESS STEEL NEGATOR CLOSURE SPRING 1 1 /2 "x1 11/2"A/8" GALVANIZED ANGLE. FASTEN DAMPER TO SLEEVE BY WELDING 6" ON CENTER. (ON ALL 4 SIDES) TYPICAL FIRE DAMPER DETAIL tLT.3. 2" SHEET METAL BAND, 16 GAUGE. (TYPICAL OF 2) ATTACH UNIT TO SUPPORT STAND WITH 1/2 "0, GALVANIZED STEEL, TIE DOWN BOLTS, AT 24" OC. PROVIDE WASHERS, DOUBLE LOCKING NUTS AND VIBRATION ISOLATOR AS REQUIRED AT EVERY TIE DOWN. 1/2 "0, GALVANIZED STEEL, BOLTS AND NUTS. (TYPICAL) 2 1/2 "x2 1/2 "0/4" GALVANIZED ANGLE. TYPICAL OF 4. (TWO PER SIDE) EXISTING CONDENSING UNIT SUPPORT. EXISTING ROOF. 11/2"0 EXPANSION BOLT INTO STRUCTURE WITH 1" EMBEDMENT AHU CASING NEW CONDENSING UNIT. NOTE: 1- CONTRACTOR TO SIZE UNIT TIE DOWN TO WITHSTAND WIND FORCES PER F.B.C. 2- CONTRACTOR TO VERIFY THAT EXISTING STRUCTURE IS IN GOOD CONDITION AND ITS STRUCTURAL MEMBERS AND TIE DOWNS TO EXISTING ROOF ARE SIZED TO SUPPORT THE NEW EQUIPMENT. CONDENSING UNIT MOUNTING DETAIL MT.3 SUPPORT CROSS ANGLE (2 1/2 "x2 1/2 "0/4 ") TREADED NNGER ROD ATION ISOLA" 2Y HANGER F Ault PACIAIP /2" (12ga) JILL. {� VI 1/11.LL. TOP HUNG BOTTOM HUNG NOTES: 1- TOP OR BOTTOM INSTALLATION SHALL BE USED DEPENDING MANUFACTURER RECOMMENDATION, AND FIELD CONDITIONS. 2- FOLLOW MANUFACTURER RECOMMENDATION FOR REQUIRED HANGING ROD DIAMETER SIZE. 3- VERIFY EXISTING SUPPORTING BUILDING STRUCTURE BEFORE INSTALLATION. 4- USE DOUBLE LOCKING NUTS AND WASHERS. AHU SUPPORT DETAIL N.T.S. CONNECTING DUCTWORK XHAUST FAN CABINET NOTE: FASTEN FAN TO STRUCTURE AS PER MANUFACTURER RECOMMENDATIONS CEILING EXHAUST FAN DETAIL MT.& FINISHED ROOF D NOTE OSHEET METAL GOOSENECK, 22 GA, O ATTACHED GOOSENECK TO AIR AND WATER TIGHT. APPLY A CURS AS REQUIRED. WEATHER PROTECTIVE COATING. 6O ROOF SYSTEM. @END GOOSENECK WITH A RIVETED OR SPOT WELDED ANGLE FRAME. 7O FLASHING AS REQUIRED BY OTHERS. ALL AROUND. O SHEET METAL DUCTWORK. @PROVIDE 1/2" ALUMINUM BIRD SCREEN. 8 SEE PLANS FOR SIZES. O INSULATED ROOF CURB. NOTES: 1. SECURE ASSEMBLY AS REQUIRED TO WITHSTAND, HURRICANE FORCE WINDS AS PER F.B.C. 2. FOLLOW SMACNA CONSTRUCTIION GUIDELINES. TYPICAL GOOSENECK DETAIL MT.& SEAL JOINT WITH DUCT SEALER AND TAPE MANUAL VOLUME DAMPER DRAW -� BAND SPIN COLLAR WITH DAMPER AND EXTRACTOR 3/4 "0 AUXILIARY DRAIN PAN PIPING TO A CONSPICUOUS LOCATION. SEE PLUMBING PLANS FOR CONTINUATION. AIR FLOW LOW VELOCITY SUPPLY AIR DUCT (SEE PLAN VIEW) 0 MANUAL VOLUME DAMPER INSTALL FLEXIBLE DUCT SUPPORT AS REQUIRED FOR NO SAG. INSULATED AND VAPOR SEALED COLLAR AND DIFFUSER BACK PANEL DIFFUSER -� DETAIL ''A" D1T.3. FOLLOW SMACNA DUCT CONSTRUCTION STANDARDS 1/4" ALUMINI BIRD SCREEN FLASHING FINISHED — ROOF i 1/2" SHEET METAL SCREW (4 TYPICAL) 23" DIAM. 10" MIN \_SHEET METAL SUPPORT STRAPS SHEET METAL DUCT. SEE FLOOR PLAN FOR SIZES. NOTES: 1. SECURE ASSEMBLY AS REQUIRED TO WITHSTAND, HURRICANE FORCE WINDS AS PER F.B.C. 2. FOLLOW SMACNA CONSTRUCTION GUIDELINES. ROOF CAP INSTALLATION DETAIL RT.8. FLEXIBLE DUCT CONNECTION DETAIL MT.& SUPPORT TO STRUCTURE. AS PER DETAIL THIS DRAWING. FAN SECTION ACCESS PANEL LIQUID AND SUCTION -LINES TO CU. FILTER ACCESS COIL SECTION ACCESS PANEL FOAM RUBBER ISOLATION BETWEEN CHANNEL AND UNIT OR AUXILARY PAN (TYPICAL) FLEXIBLE CONNECTION (TYPICAL) AUXILIARY DRAIN PAN. MINIMUN CONDENSATE DRAIN PIPING. DEPTH 1 1/2 AND 22 GAGE, AND SEE PLUMBING PLANS FOR .SHALL BE EXTENDED 3" BEYOND CONTINUATION. p UNIT PERIMETER. PROVIDE A FLOAT SWITCH TO SHUT DOWN THE UNIT IN THE EVENT OF CONDENSATE SPILL INTO THE AUXILIARY PAN. NOTES: 1 PROVIDE 36" SERVICE CLEARANCE FOR ALL ACCESS PANELS. 2 PROVIDE ADEQUATE ACCESS TO! FILTER SECTION. AIR HANDLING UNIT INSTALLATION DETAIL tLT.9. DETAIL "A" AIR FLOW SPIN COLLAR FITTING WITH EXTRACTOR AND DAMPER. QUADRANT OPERATOR TO BE OUTSIDE INSULATION. PROVIDE INSULATION GUARD WHERE NECESSARY. SEAL JOINT WITH DUCT �_ SEALER AND TAPE 12 GAGE MINIMI SIZE SUPPORT EXISTING STRU( POWER ACTUATER FASTENERS (TYP.). ALTERNATE TYPE �- ROOF SYSTEM DUCT WORK SECURE WITH PLASTIC STRAPS TO INSULATION REFRIGERANT LIQUID LINE ADJUST THIS DIMENSION IN STRUCTURE FIELD AS REQ'D q�REFRIGERANT HOT GAS LINE STRAP HANGER INSULATION END VIEW ADJUST THIS DIMENSION IN FIELD AS REQ'D T REFRIGERANT LIQUID LINE REFRIGERANT HOT GAS LINE INSULATION J SADDLE SUPPORT SIDE VIEW NOTES: 1- PROVIDE DIELECTRIC ISOLATION BETWEEN DISSIMILAR METALS 2- PROVIDE SADDLE PROTECTION AT EACH SUPPORT RANT PIPING �:TI! STRUCTURAL BEAM BEAM CLAMP —(TYP.) HANGER / —RODS (TYP.) STRUCTURE ATTACHMENT DETAIL N.T.8. AT 5' -0" ON CENTER FOR DUCTS UP TO 35" AND 6' -0" FOR DUCTS UP TO 59 ", PER SMACNA RECOMENDATIONS. RECTANGULAR DUCT SUPPORT DETAIL N,T.B. diez architecture, inc, 7430 sw 48th street miami, florido 33155 phone: (305) 663 -1970 fax: (305) 663 -2312 e -mail: peter©diezarchitecture.com pedro diez, ro president or 0008996 ENGINEERING CONSULTANT Puga and Associates, Inc. Engineers /Consultants # EB 0005813 7326 S.W. 48th Street Miami, Florida 33155 (305) 661 -7700 ODIC J?icFi 4th FLOOR 6141 SUNSET DRIVE SOUTH MIAMI, FLORIDA !' EMBEDMENT PROJECT No. 04.158.041 REVISIONS 3HER 1 1/2" 26 GAUGE, MINIMUM HANGER STRAPS SUPPORTED FROM EXISTING STRUCTURE. SHEET METAL J S I t ADDLE MINIMUM 5' -0" ON CENTER 6" MIN. NOTE: HANGERS SHALL BE LOCATED AT DUCT JOINTS OR AS CLOSE AS POSSIBLE AS PER SMACNA DUCT CONSTRUCTION STANDARDS FIBROUS ROUND AND FLEXIBLE DUCT ROUND DUCT SUPPORT DETAIL tLT.B �:.. oc '9 `up f� J. UAVIO P P.�. Rio. 4 SCALE: AS SHOWN DATE: October 9, 2006