Loading...
06-1828-015BRANCH TAKEOFF WITH 450 SHOE FITTING WITH MANUAL VOLUME DAMPER. Lk t� DUCT ELBOW WITH DOUBLE THICKNESS TURNING VANES (�C�OC{XXX)' FLEXIBLE ROUND DUCT. INSIDE DIMENSIONS. i -- ®-- SUPPLY AIR, CEILING MOUNTED REGISTER RETURN AIR, CEILING MOUNTED REGISTER DIFFUSER GRILLE TAG WITH REQUIRED O560 AIR VOLUME. SEE SCHEDULE FOR SIZES CFM AND THROW PATTERN. 0 DIAMETER O ROOM THERMOSTAT OR THERMIDISTAT. 1 NUMBER NEXT TO SYMBOL DENOTES A/C UNIT MARK. FD FIRE DAMPER, EQUAL TO AIR BALANCE INC., MODEL 119C, LEAKAGE CLASS II. SIZE DAMPER AS REQUIRED TO MAINTAIN SAME FREE AREA AS DUCT. VD MANUAL VOLUME DAMPER SD DUCT MOUNTED SMOKE SENSOR HVAC DESIGN REQUIRES: LEGEND ABV ABOVE CD CEILING DIFFUSER CFM CUBIC FEET PER MINUTE CLG. CEILING CONN CONNECT, CONNECTION DB DRY BULB DDC DIRECT DIGITAL CONTROL DI DIGITAL INPUT ON DOWN DP DIFFERENTIAL PRESSURE DR DRAIN DWG DRAWING EA. EACH ENT ENTERING EQUIP EQUIPMENT GA. GAUGE GALV. GALVANIZED HTR. ELECTRICAL HEATER HP HORSEPOWER KW KILOWATTS IN INCHES MAX. MAXIMUN MIN MINIMUN No. NUMBER NTS NOT TO SCALE 0/A OUTSIDE AIR P.D. PRESSURE DROP PSF POUND PER SQUARE FOOT QTY QUANTITY R/A RETURN AIR RPM REVOLUTIONS PER MINUTE RTU ROOFTOP UNIT S/A SUPPLY AIR S.P. STATIC PRESSURE SPS STATIC PRESSURE SENSOR TEMP. TEMPERATURE TRF TRANFER TS TEMPERATURE SENSOR TYP. TYPICAL UC UNDERCUT UP UP VAV VARIABLE AIR VOLUME VD MANUAL VOLUME DAMPER VEL VELOCITY VVT VARIABLE VOLUME AND TEMPERATURE V /PH VOLTAGE /PHASE WB WET BULB OPERATION UNDER ALL LOAD CONDITIONS AS PER ASHIRAE -62 VENTILATION RATE PROCEDURE. DASHED LINES DEPICT EXISTING DETERMINED ON THE BASIS OF AVERAGE OCCUPANCY FOR BUILDINGS, FOR THE DURATION OF OPERATION OF THE DUCTWORK / DEVICES TO REMAIN. BRANCH TAKEOFF WITH 450 SHOE FITTING WITH MANUAL VOLUME DAMPER. Lk t� DUCT ELBOW WITH DOUBLE THICKNESS TURNING VANES (�C�OC{XXX)' FLEXIBLE ROUND DUCT. INSIDE DIMENSIONS. i -- ®-- SUPPLY AIR, CEILING MOUNTED REGISTER RETURN AIR, CEILING MOUNTED REGISTER DIFFUSER GRILLE TAG WITH REQUIRED O560 AIR VOLUME. SEE SCHEDULE FOR SIZES CFM AND THROW PATTERN. 0 DIAMETER O ROOM THERMOSTAT OR THERMIDISTAT. 1 NUMBER NEXT TO SYMBOL DENOTES A/C UNIT MARK. FD FIRE DAMPER, EQUAL TO AIR BALANCE INC., MODEL 119C, LEAKAGE CLASS II. SIZE DAMPER AS REQUIRED TO MAINTAIN SAME FREE AREA AS DUCT. VD MANUAL VOLUME DAMPER SD DUCT MOUNTED SMOKE SENSOR HVAC DESIGN REQUIRES: YES NO DUCT SMOKE DETECTOR • OUTSIDE AIR FIRE DAMPER(S) AIR EXHAUSTED EXH. EQUIP. SMOKE DAMPER(S) AREA SERVE NET. SQ. FT. FIRE RATED ENCLOSURE CFM /PERSON OR TRANSFER FIRE RATED ROOF FLOOR CEILING ASSEMBLY REQUIRED USED_.! FIRE STOPPING WAITING ROOM 275 SMOKE CONTROL 10 ( +) 100 BUILDING AIR PLOW RECAPITULATION SCHgDULE A/C EQUIP. INxINECK AREA SERVED UNIT DESIGNATION AHU -1 AHU -2 AHU -3 OUTSIDE AIR TOTAL OUTSIDE AIR AIR EXHAUSTED EXH. EQUIP. TAG No. AREA SERVE NET. SQ. FT. PEOPLE CFM /PERSON OR TRANSFER TAG No. REQUIRED USED_.! AHU -1 WAITING ROOM 275 10 10 ( +) 100 100 - - OFFICES 781 4 20 80 100 -75 EF -2 24x24 AHU -2 OFFICES 581 10 20 200 200 -75 EF -1 AHU -3 OFFICES 649 12 20 240 240 - - MOTOR SIZE HP LOUVERED FACE DIRECTIONAL O 24x24 0 PRICE AMD- 3P -B12 AHU -4 OFFICES 596 4 20 80 80 - - - -- LOUNGE 176 6 10 ( *) 60 80 - - TOTALS O 1 +800 -150 PRICE BUILDING PRESSURIZATION + 650 CFM NOTES: l� 1 OUTDOOR AIR PROVISIONS FOR VENTILATION SHALL SATISFY THE MINIMUM REQUIREMENTS FOR ACCEPTABLE INDOOR AIR QUALITY AS PER ASHARE;62 -19p', VENTILATION RATE PROCEDURE. 2 THE FULL VOLUME OF OUTSID�• AIA "ESTABLISHED IN THIS SCHEDULE SHALL BE DELIVER TO THE SPACE AT ALL TIMES THAT THE BUILDING IS OCCUPIED 3 FOR ALL VARIABLE AIR VOLUME MACHINES, CONTROL SYSTEM SHALL GUARANTEE THAT THE REQUIRED AMOUNT OF OUTSIDE AIR IS DELIVERED TO EVERY SPACE DURING BUILDING OPERATION UNDER ALL LOAD CONDITIONS AS PER ASHIRAE -62 VENTILATION RATE PROCEDURE. ( +) 6.1.3.4 ... "WHERE PEAK OCCUPANCIES OF LESS THAN TFHREE HOURS OCCUR, THE OUTDOOR AIR FLOW RATE MAY BE DETERMINED ON THE BASIS OF AVERAGE OCCUPANCY FOR BUILDINGS, FOR THE DURATION OF OPERATION OF THE SYSTEM, PROVIDED THE AVERAGE OCCUPANCY USED I& NOT LESS THAN ONE -HALF THE MAXIMUM." AIR DISTRIBUTIION SCHEDULE MARK INxINECK 33155 UNIT DESIGNATION AHU -1 AHU -2 AHU -3 AHU -4 SYMBOLS MFGR MODEL SERIES REMARKS FACE NECK RESTROOMS 0008996 UNIT MANUFACTURER TRANE MANUFACTURER COOK TRANE LOUVERED FACE DIRECTIONAL O 24x24 5 "0 PRICE AMD- 3P -B12 SUPPLY DIFFUSER NOMINAL TONS 2.5 4.0 SYSTEM TYPE EXHAUST LOUVERED FACE DIRECTIONAL O 24x24 6"0 PRICE AMD -3P -812 SUPPLY DIFFUSER E.S.P. (IN WATER) 0.25 930 1,510 LOUVERED FACE DIRECTIONAL C 24x24 8 "0 PRICE AMD- 3P -B12 SUPPLY DIFFUSER 1,058 160 MOTOR SIZE HP LOUVERED FACE DIRECTIONAL O 24x24 10 "o PRICE AMD- 3P -B12 SUPPLY DIFFUSER DRIVE TYPE DIRECT LOUVERED FACE DIRECTIONAL O 12x12 - -- PRICE AMD -1 -1312 SUPPLY DIFFUSER SONE RATING (MAX.) 1.9 LOUVERED FACE DIRECTIONAL O 12x8 - -- PRICE 620DAL- F -L -B12 SUPPLY REGISTER Q EXTERNAL STATIC PRESSURE I.W.G. 0.6 LOUVERED FACE DIRECTIONAL O 26x10 - -- PRICE 620DAL- F -L -B12 SUPPLY REGISTER NOTES: 1 FANS LOCATED ON THE EXTERIOR OF THE BUILDING SHALL BE CONSTRUCTED AND INSTALLED TO WITHSTAND A WIND PRESSURE OF FROM ANY DIRECTION AS PER F.B.C. 2 ALL FANS SHALL HAVE UL APPROVED LOCAL DISCONNECT MEANS, SUPPLIED BY ELECTRICAL CONTRACTOR. 3 ROOF FANS AND VENTS SHALL HAVE BACK -DRAFT DAMPERS AND BIRD SCREENS. 4 FANS SHALL BE OF WELDED CONSTRUCTION UTILIZING CORROSION RESISTANT FASTENERS. ALL STEEL FAN COMPONENTS SHALL HAVE A SUPERFICIAL ELECTROSTATIC COATING TREATMENT TO PREVENT CORROSION. 5 MOTORS SHALL BE HEAVY DUTY TYPE WITH PERMANENTLY LUBRICATED SEALED BALL BEARINGS AND FURNISHED TO THE SPECIFIED VOLTAGE, PHASE AND ENCLOSURE. 6 FAN SHALL BE OF AN AMERICAN MANUFACTURER AND MANUFACTURED AT AN ISO 9001 CERTIFIED FACILITY. 7 ALL FAN SHALL BEAR AMCA CERTIFIED RATING AND UL LISTING. 8 FANS EF -1 AND 2 SHALL BE SWITCHED BY LIGHTS. = FAN SIZE HP 1/2 3/4 3/4 1/2 LOUVERED EXHAUST O2 12x12 - -- PRICE 635- F -L -B12 SURFACE MOUNTED Ly LOUVERED RETURN O 24x24 22x22 PRICE 635 -TB -L -812 24x24 PANEL NOTES: 1- REFER TO PLAN FOR QUANTITY, LOCATION AND FAIR THROW PATTERN. EXHAUST FAN SCHEDULE MARK EF -1,2 33155 UNIT DESIGNATION AHU -1 AHU -2 AHU -3 AHU -4 LOCATION CEILING WAITING ROOM OFFICES OFFICES SYSTEM /AREA SERVED RESTROOMS 0008996 UNIT MANUFACTURER TRANE MANUFACTURER COOK TRANE MODEL NUMBER GC -140 TWE049E13FB TWE049E13FB TWEO31E13F8 WEIGHT (LBS) APPROX. 18 NOMINAL TONS 2.5 4.0 SYSTEM TYPE EXHAUST SYSTEM (S)EER DESIGN CFM SETTING 75 14.00 14.00 E.S.P. (IN WATER) 0.25 930 1,510 1,390 FAN TYPE CENTRIFUGAL OUTSIDE AIR CFM 200 FAN RPM 1,058 160 MOTOR SIZE HP 43 WATTS ELECTRICAL SERVICE 115/1/60 DRIVE TYPE DIRECT RETURN AIR CFM CONTROL FSC 5 1,150 730 SONE RATING (MAX.) 1.9 BACKDRAFT DAMPER MODEL No. 100 SERIES z ACCESSORIES /REMARKS GEMINI ISO KIT Q EXTERNAL STATIC PRESSURE I.W.G. 0.6 0.6 0.6 0.6 NOTES: 1 FANS LOCATED ON THE EXTERIOR OF THE BUILDING SHALL BE CONSTRUCTED AND INSTALLED TO WITHSTAND A WIND PRESSURE OF FROM ANY DIRECTION AS PER F.B.C. 2 ALL FANS SHALL HAVE UL APPROVED LOCAL DISCONNECT MEANS, SUPPLIED BY ELECTRICAL CONTRACTOR. 3 ROOF FANS AND VENTS SHALL HAVE BACK -DRAFT DAMPERS AND BIRD SCREENS. 4 FANS SHALL BE OF WELDED CONSTRUCTION UTILIZING CORROSION RESISTANT FASTENERS. ALL STEEL FAN COMPONENTS SHALL HAVE A SUPERFICIAL ELECTROSTATIC COATING TREATMENT TO PREVENT CORROSION. 5 MOTORS SHALL BE HEAVY DUTY TYPE WITH PERMANENTLY LUBRICATED SEALED BALL BEARINGS AND FURNISHED TO THE SPECIFIED VOLTAGE, PHASE AND ENCLOSURE. 6 FAN SHALL BE OF AN AMERICAN MANUFACTURER AND MANUFACTURED AT AN ISO 9001 CERTIFIED FACILITY. 7 ALL FAN SHALL BEAR AMCA CERTIFIED RATING AND UL LISTING. 8 FANS EF -1 AND 2 SHALL BE SWITCHED BY LIGHTS. 0 diez architecture, inc. 7430 sw 48th A/C EQUIPMENT SCHEDULE miami, florido 33155 UNIT DESIGNATION AHU -1 AHU -2 AHU -3 AHU -4 fax: (305) AREA SERVED WAITING ROOM OFFICES OFFICES OFFICES president ar 0008996 UNIT MANUFACTURER TRANE TRANE TRME TRANE MODEL NUMBER TK031El3F9 TWE049E13FB TWE049E13FB TWEO31E13F8 NOMINAL TONS 2.5 4.0 4.0 2.5 SYSTEM (S)EER 14.00 14.00 14.00 14.00 TOTAL AIR SUPPLY CFM 930 1,510 1,390 890 OUTSIDE AIR CFM 200 200 240 160 z RETURN AIR CFM 730 1,310 1,150 730 0 z Q EXTERNAL STATIC PRESSURE I.W.G. 0.6 0.6 0.6 0.6 = FAN SIZE HP 1/2 3/4 3/4 1/2 Ly a FAN MOTOR FLA AMP 4.3 7.0 7.0 4.3 ENTERING AIR TEMPERATURE (DB /WB)° F 80.0 67.9 77.9 64.0 79'0 65.4 80'1 66.4 LEAVING AIR TEMPERATURE (DB /W8)° F 58.5 6 54.8 531 55.5 54.0 55.2 54.0 TOTAL COOLING COIL CAPACITY MBH 29.1 49.0 48.4 29.5 TOTAL SENSIBLE CAPACITY MBH 19.1 38.9 35.7 21.0 TOTAL HEATING CAPACITY MBH 12.3 12.3 12.3 12.3 ELECTRIC HEATER SIZE (230 V) Kw 5 5 5 5 HEATER MCA / MOCP AMP 24 25 24 25 24 25 24 25 ELECTRICAL CHARACTERISTICS V /O /Hz 208/1/60 208/1/60 208/1/60 208/1/60 WEIGHT I b s. 118 196 196 118 DIMENSIONS (HxWxD) INCH 43x22x21 63x26x21 63x26x21 43x22x21 UNIT DESIGNATION CU -1 CU -2 CU -3 CU -4 UNIT MANUFACTURER TRANE TRANE TRANE TRANE MODEL NUMBER 2TTA303OA3000A 2TTA3048A3000A 2TTA306OA3000A 2TTA303OA30WA LOCATION ROOF ROOF ROOF ROOF N AMBIENT TEMPERATURE ° F 95 95 95 95 z Z REFRIGERANT R 22 22 22 22 0 0 COMPRESSOR MOTOR RLA AMP 6.8 11.6 11.6 6.8 0 0 FAN MOTOR SIZE HP 1/8 1/6 1/6 1/8 0 Of FAN MOTOR FLA AMP 03 1.4 1.4 0.7 MCA / MOCP AMP 13 20 16 25 16 25 13 20 ELECTRICAL CHARACTERISTICS V /O /Hz 208/3/60 208/3/60 208/3/60 208/3/60 WEIGHT Ibs. 197 267 267 197 DIMENSIONS (HxWxD) INCH 330300 410704 41x37x34 33x33x30 NOTES: 1 ALL UNITS SHALL BE HORIZONTALLY MOUNTED WITH TOP SUPPLY AND BOTTOM RETURN AS INDICATED ON DRAWINGS. 2 SIZE REFRIGERATION PIPING AS PER MANUFACTURER RECOMMENDATIONS. OVERSIZE LINES AS REQUIRED TO COMPENSATE FOR LINE LOSS WITH MINIMUM CAPACITY REDUCTION. SUBMIT SHOP DRAWINGS. 3 AIR HANDLING UNIT SHALL CONTAIN SOLID STATE INTERLOCK BOARD WITH BUILT IN FUSE AND TIME DELAY RELAY. 4 PROVIDE 5 YEAR WARRANTY ON ALL REFRIGERATION COMPONENTS. 5 PROVIDE ALL RELAYS, TRANSFORMERS, ETC. AS REQUIRED FOR COMPLETE OPERATING SYSTEM. 6 UNITS SHALL BE PROVIDED WITH A 4 INCH THICK PLEATED FILTER WITH A 30% MINIMUM EFFICIENCY. UNIT CONSTRUCTION AND INSTALLATION SHALL GUARANTEE AN EASY ACCESS TO FILTER SECTION FOR PROPER FILTER INSPECTION AND REPLACEMENT. 7 UNIT INSULATION AND ADHESIVE SHALL COMPLY WITH NFPA 90A REQUIREMENTS FOR FLAME SPREAD AND SMOKE GENERATION. INSULATION SHALL CONTAIN AN EPA REGISTERED IMMOBILIZED ANTI - MICROBIAL AGENT TO EFFECTIVELY RESIST THE GROWTH OF BACTERIA AND FUNGI IN ACCORDANCE WITH ASTM STANDARDS G21 AND G22. 8 FAN MOTOR SHALL BE HIGH EFFICIENCY TYPE. 9 FAN AND MOTORS SHALL BE PROVIDED WITH CIRCUIT PROTECTION. 10 CONDENSATE DRAIN PANS SHALL BE INSULATED AND SLOPED TO OUTLET. PANS SHALL HAVE STAINLESS STEEL LINERS. PROVIDE A OVERFLOW DETECTION SYSTEM CAPABLE OF SHUTDOWN THE UNIT UPON DECTION OF HIGH LEVELS CONDENSATE DRAIN. 11 SUPPORT UNIT HIGH ENOUGH ABOVE CEILING TO ACCOMMODATE CONDENSATE DRAIN TRAPS IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS. 12 THE FAN DRIVE SHALL BE SELECTED FOR 125% OF THE MOTOR RATED HORSEPOWER. 13 CONTRACTOR SHALL GUARANTEE ADECUATE CLEARANCE ALL AROUND THE UNIT FOR MAINTENANCE ACCESS. 14 CONDENSING UNIT SHALL BE INSTALLED TO WITHSTAND WIND PRESSURE FROM ANY DIRECTION AS PER THE "HVHZ" REQUIREMENTS OF THE F.B.C. 15 ALL UNITS SHALL BE OF DOUBLE WALL CONSTRUCTION. ALL UNITS SHALL BE PROVIDED WITH ADEQUATE INSULATION. PROVIDE INSULATION LINERS TO PREVENT SURFACE CONDENSATION UNDER ALL CONDITIONS. 16 ALL UNITS SHALL HAVE A STAINLESS STEEL, DOUBLE SLOPED DRAIN PAN WITH INSULATION LINERS IN ACCORDANCE WITH ASHORE 62. 17 UNITS SHALL BE OF AMERICAN MANUFACTURER, DESIGNED AND RATED IN ACCORDANCE WITH ALL APPLICABLE ASHRAE, AIR AND NFPA CODES AND STANDARDS AND SHALL BE UL LISTED. 18 CONDENSER COILS SHALL BE PROVIDED WITH A PROTECTIVE GUARD. 19 ALL UNITS SHALL BE PROVIDED WITH A 2 -STAGE PROGRAMMABLE, DIGITAL THERMOSTAT WITH DEHUMIDIFICATION CONTROL EQUAL TO HONEYWELL MODEL No. TH8321U1006 AND SHALL BE CAPABLE OF PROVIDING AFTER HOURS SET BACK FOR ENERGY CONSERVATION PURPOSES. 20 DUCT MOUNTED SMOKE DETECTOR FOR ALL UNITS SHALL BE PROVIDED AND INSTALLED BY MECHANICAL CONTRACTOR AND WIRED BY FIRE ALARM CONTRACTOR. diez architecture, inc. 7430 sw 48th street miami, florido 33155 phone: (305) 663 -1970 fax: (305) 663 -2312 e -mail: peter @diezorchitecture.com pedro diez, ra president ar 0008996 ENGINEERING CONSULTANT Puga and Associates, Inc. Engineers /Consultants # EB 0005813 7326 S.W. 48th Street Miami, Florida 33155 (305) 661 -7700 17a. jq" (99k" 4th FLOOR 6141 SUNSET DRIVE SOUTH MIAMI, FLORIDA PROJECT No. 04.158.041 REVISIONS c ; bc 2006 .4 1 15AVID PUOA v D.� M- w.44 � Ivi