Loading...
06-1828-002LEGAL DESCRIPTION LOTS 5 THROUGH 15, BLOCK 2, LESS THE SOUTH 21 FEET FOR RIGHT OF WAY DEDICATION OF SW -72 ST, LARKIN CENTER ACCORDING TO THE PLAT THEREOF, AS RECORDED IN PLAT BOOK 27, PAGE 6 -1. AND LOT 5, BLOCK 2, RO55WOOD AGGORDING TO THE PLAT THEREOF, AS RECORDED IN PLAT BOOK 15, PAGE 62. OCCUPANT LOAD AND BUILDING TYPE GR055 FOURTH FLOOR AREA 11,764 60FT. CODE E OCCUPANCY — 2004 FLORIDA BUILDING CODE BUSINESS GROUP B OCCUPANT LOAD (1/100 6.F.) 11,1641100 = 116 BUILDING CONSTRUCTION TYPE — TYPE III B PROTECTED PLUMBING FIXTURES REQUIRED AS PER FBC -P- 403.1, BUSINESS 3 WC 2 LAV I SERVICE SINK 2 DF PLUMBING FIXTURES PROVIDED ON FOURTH FLOOR 9 WC 9 LAV I SERVICE SINK 2 DF GROSS PROJECT AREA 3,384 SQ,FT. CODE ¢ OCCUPANCY — 2004 FLORIDA BUILDING CODE BUSINESS GROUP B OCCUPANT LOAD (1/100 SF.) 3,384/100 = 33 BUILDING CONSTRUCTION TYPE —TYPE III B PROTECTED PLUMBING FIXTURES REQUIRED AS PER FBC -P- 403.1, BU61NESS 1 WC 1 LAV 1 SERVICE 51NK I DF PLUMBING FIXTURES PROVIDED WITHIN TENANT AREA ON FOURTH FLOOR 2 WC 2 LAV REMAINING FIXTURES ARE PROVIDED WITHIN THE FOURTH FLOOR COMMON ARE 1 SERVICE SINK 1 DF SW 61 AVE SITE PLAN PROJECT DATA TONING 015TRICT SW 61 CT MU -4 / MU -5 SITE AREA 30,%4 5F BUILDING AREA: phone: (305) 663-1970 EXISTING GROUND FLOOR AREA 9,121 6F EXISTING SECOND FLOOR AREA 494 6F EXISTING THIRD FLOOR AREA 11,181 6F EXISTING FOURTH FLOOR AREA 11,164 6F EXISTING FIFTH FLOOR AREA 10,342 SF TOTAL AREA 43,508 6F OFF STREET PARKING REQUIRED 129 SPACES EXISTING OFF STREET PARKING PROVIDED 134 SPACES EXISTING ON STREET PARKING PROVIDED 1 6PACE8 AREA OF WORK: FOURTH FLOOR (TOTAL AREA OF WOW) 384 6F EXISTING BUILDING DATA 5 STORY CBS BLDG. WITH CONCRETE JOIST FLOOR AND ROOF STRUCTURE AND CONCRETE INTERIOR COLUMNS. BLDG. TYPE- TYPE III I HR PROTECTED W/ FULLY AUTOMATIC FIRE SPRINKLER SYSTEM THROUGHOUT ENTIRE BLDG. FIRE RESISTANCE RATING- I HR FIRE RATING FOR STRUCTURAL ELEMENTS s FLOORS AND 2 HR FIRE PROTECTION FOR EXTERIOR WALLS A$ PER FBC 2004 TABLE 601. OFFICE6 TO HAVE A FIRE ALARM SYSTEM AND M AUTOMATIC FIRE 6UPPRE68ION SYSTEM. SUBMIT SHOP DRAWING FOR REVIEW. 1 :30 GENERAL NOTES i-' U) N f\ W 0) Z I,- CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITION$ AND SHALL NIOTIFY THE ARCHITECT IF ANY D15CREPANCIE6 ARE DISCOVERED BEFORE PROCEEDING WITH THE WORK. 2- CONTRACTOR TO ACQUIRE ALL REQUIRED PERMITS FOR THE CONSTRUCTION AND SUBSEQUENT OCCUPANCY OF PROJECT. 3.- ALL WORK DONE UNDER THE SUPERVISION OF THE CONTRACTOR SHALL BE DONE IN A NEAT AND WORKMAN -LIKE MANNER AND IN ACCORDANCE WITH ALL GOVERNING AGENCIE6 , RULES AND REGULATIONS HAVING JURISDICTION. 4- CONTRACTOR TO PROVIDE ALL SUPPLEMENTARY MATERIALS REQUIRED TO INSTALL, 61UPPORT, BRACE AND 6HORE ALL BUILDING COMPONENTS. 5- PRIOR TO COMMENCING WORK, THE CONTRACTOR SHALL VERIFY THE LOCATION OF ALL EQUIPMENT AND UTILITIES TO BE REMOVED REMOVALS SHALL BE COORDINATED WITH THE OWNER AND ALL BUILDING AUTHORITIES HAVING JURISDICTION. 6- CONTRACTOR SHALL PROVIDE THE ARCHITECT WITH RED -LINED 46 BUILT DRAWINGS FOR ANY AND ALL FIELD CHANGES AND/ OR ADDITIONS TO THE WORK INCLUDED IN THE DRAWINGS. 1: IF ANY CHANGES AND /OR DEVIATIONS ARE MADE TO THESE PLANS WITHOUT TIRE WRITTEN AUTHORIZATION OF THE ARCHITECT , THE CONTRACTOR SHALL BEAR FULL RESPONSIBILITY FOR SUCH CHANGES AND/ OR DEVIATIONS. 8 IF: DURING THE COURSE OF CONSTRUCTION ANY DEVIATIONS ARE MADE AT THE FIELD, AGAIN, THE CONTRACTOR SHALL BEAR FULL RESPONSIBILITY FCR SUCH CHANGES AND / OR DEVIATIONS. 9.-ALL -SHOP DRAWINGS SHALL BE SUBMITTED TO THE ARCHITECT FOR DE51GN CONFORMANCE ONLY. 10- 61U55TITUTION5 MUST BE REVIEWED AND APPROVED BY THE ARCHITECT OR ENGINEERS. 11.- CONTRACTOR AND SUBCONTRACTORS SHALL BE RESPONSIBLE FOR CLEANING HIS OR HER OPERATION AND REPAIRING ANY DAMAGE TO HIS WORK WHILE PROJECT 15 UNDER UNDER CONSTRUCTION 12.- ALL WORK SHALL BE PERFORMED TO MEET AND COMPLY WITH A_DA. STANDARDS AND 2004 F.B.C. CHAPTER 11, F.A.C. 13.- ALL DESIGNS AND DRAWINGS HERE IN AND PRINTS ISSUED BY THE ARCHITECT ARE THE PROPERTY OF THE ARCHITECT AND SHALL NOT BE REUSED ON ANY OTHER LOCATION EXCEPT FOR THE ONE FOR WHICH THEY WERE EXPRE68LY DESIGNED. IF THESE DRAWINGS OR ANY PART THERE OF 16 REPRODUCED WITHOUT TIHE CONSENT OF THE ARCHITECT, THE PER60N DOING 60 WILL BE INDEBTED TO TIRE ARCHITECT FOR H16 FULL COMMISSION. CONSTRUCTION NOTES I. LOCATE EXIST SANITARY SEWER AND EXTEND AS REQUIRED FOR NEW SERVICES. 2, GENERAL CONTRACTOR SHALL PROVIDE ALL SHORING AND TEMPORARY SAFEGUARDS, DUST BARRIERS AND WARNING SIGN$ AS REQUIRED. 3. GENERAL CONTRACTOR SHALL NOTIFY OWNER/ BLDG. MANAGER IN WRITING THREE DAYS PRIOR TO MAJOR ELECTRICAL OR MECHANICAL 6HUTDOUN 4 REQUIRED DOWNTIME SO THAT APPROPRIATE ACTION CAN BE TAKEN. 4. CONTRACTOR SHALL VERIFY ALL DIMEN51ON5 AND CONDITIONS a SHALL NOTIFY THE ARCHITECT IN WRITING OF ANY DISCREPANCIES. 5. ACTUAL EX16TING DIMENSIONS SHALL GOVERN. 6. ALL DEBRIS TO BE DISPOSED OF BY CONTRACTOR. ACCESSIBILITY NOTES 1. RESULTS OF THIS RENOVATION WILL NOT CREATE ANY ARCHITECTURAL BARRIERS (4.1614.18 FA.C). 2. ALL LEVELS ARE ACCESSIBLE 3. ALL NEW DOORS ARE 2' -10' WIDE MIN, 32' CLEAR OPENING, 4. COMMON PATH OF TRAVEL, MAXIMUM LEVEL DIFFERENCE 1/2' SCOPE OF WORK WORK CON613T6 OF THE INTERIOR BUILD OUT THE EXISTING VACANT SPACE, INCLUDED IN WORK ARE ELECTRICAL, PLUMBING, HVAC DUCTWORK, FLOORING, CEILING, PARTITIONS AND PAINTING, SEE PLANS FOR EXTENT. 7430 sw 48th street miami, florida 33155 phone: (305) 663-1970 fax: (305) 663 -2312 e –mail: peter (gdiezarchitecture.com pedro diez, ra president or 0008996 ENGINEERING CONSULTANT e� 4th FLOOR 6141 SUNSET DRIVE SOUTH MIAMI, FLORIDA PROJECT No. 04.158.041 REVISIONS SITE PLAN otel