06-113(2)-028EXIST. 4TH FL WIREWAY 100 i I L — EXIST. TENANT 4A EXIST. TENANT 4B 5114 FL WIREWAY rE31 TENANT 5A SEE - RISER THIS SHEET 2ND FLOOR METER ROOM FIRE ALARM GENERAL NOTES: EXIST. METER 30P J li r - - - - -� I I WIREWAY TO BE MOUNTED TO STRUCTURE I � I I L — — — — J I. MINIMUM RACEWAY SIZE SHALL BE 3/4'. WIRING TO COMPLY WITH N.E.C. ARTICLE 160 -16. 2. ACTUAL FIELD WIRING REQUIREMENTS FOR NEW DEVICES SHALL BE AS INDICATED BY EQUIPMENT SUPPLIER ON APPROVED SHOP DRAWINGS. 3. MAXIMUM CONDUIT FILL - 40% OF CONDUIT AREA 4. ALL EQUIPMENT SHALL BE U.L. LISTED BY UNDERWRITERS LABORATORIES FOR THE INTENDED USE AND SHALL MEET WITH THE APPROVAL OF THE LOCAL FIRE AUTHORITIES. THE COMPLETE INSTALLATION SHALL BE MADE IN ACCORDANCE WITH NFP.A. "12 SERIES. ALL LOCAL CODES AND REQUIREMENTS, NFP.A. 101 AND N.E.G. ARTICLE 160. 5. FIRE ALARM CONTRACTOR TO PROVIDE ALL PROGRAMING, ALL FINAL CONNECTIONS, ALL TESTING AND CERTIFICATION. 6. PROVIDE NEW CONDUIT AND WIRING AS REQUIRED TO PROVIDE A COMPLETE AND WORKABLE SYSTEM AS DESCRIBED IN SPECIFICATION SECTION 16121. 1. CONTRACTOR SHALL VERIFY WITH MANUFACTURER FOR ACTUAL MANUFACTURER WIRING REGOMMNEDATIONb. 8. THE DEVICE DESIGNATION INDICATED 15 FOR INFORMATION ONLY. THE CONTRACTOR SHALL PROVIDE HIS OWN DEVICE DESKNATION FOR APPROVAL. 11 MATCH EXISTING FIRE ALARM DEVICES, WIRE CIRCUITS AND PROVIDE POWER SUPPLY AS REQUIRED. 10. CONTRACTOR TO PROVIDE BATTERY CALCULATION TO AVOID BATTERY OVERLOAD IN THE SYSTEM. 11. CONNECT NEW APPLIANCES INTO EXISTING NOTIFICATION CIRCUIT. 12. CONNECT NEW DETECTION DEVICE INTO THE EXISTING DETECTOR LOOP. 13. HORWSTROBE SHALL MEET 'ADA' REQUIREMENTS OF 6 -6' AFF. OR 6' BELOW CEILING WHICHEVER 15 LOWER 1/2 it i TENANT 5C. SEE RISER THIS SHEET TENANT 513. SEE RISER THIS SHEET IL I GI`IHI'41 JF HtiG�7 PARTIAL RISER NOTES 18 1D EXISTING 3000 AMP 1201208V, 3PH, 4111 PANEL 'HDA' ] GLG. SPACE l4 EXISTING 12' X 12' X 60' WIREWAY TO REMAIN Q EXISTING (2) SETS OF 4 -600 MCI-1 t ?M /O GND IN 4' COND EACH 16 ® KWHR METER IN NEMA 1 ENCLOSURE Q NEW 24' X 24' X 46' WIREWAY © NEW 2 PANEL 5A, Q Q NEW PANEL 513. 18 5 n ® 3 POLE 400 AMP DISC SWITCH NEMA 1 WITH 225 AMP FUSES 42 KAIC. (PANEL '5A') Og 4" 4/ 0 t 1 04 GND IN A' CONDUIT (PANEL '5A') PANEL 3DP ® EXISTING 3P.800AMP CIRCUIT BREAKiER 11 2 -2' EC WITH PULLWIRE FOR FUTURE TENANT SPACE 2� 2' EC WITH PULLWIRE FOR SPACE Q STUB 2' EC INTO EXISTING CEILING SPACE AND CAP f(a) 4 "V 0 t 1 "6 GND IN 2' COND. (PANEL '5G) 3 POLE 20041P DISC. SWITCH NEMA II WITH 150 AMP FUSES 42 kAIC. (PANEL '5C') (9) NEW PANEL '5C' ` .; r([D 3 POLE 400AMP DISC. SWITCH NEMA '1 WITH 225 AMP FUSES 42 kAIG. (PANEL 'SB') 4 " 4I 0 i i "4 GND IN 2 1/2' CONDUIT (PANEL '5B') IL I GI`IHI'41 JF HtiG�7 13 (TYP OF 4) ROOF 18 ] GLG. SPACE l4 16 1 9 6 Il 12 5TH FLOOR 11 n 18 5 n TO FIRE ALAW PANEL IST FLOIOR D� D (TYP) D g g S 5 RTU -5 RTU -4 RTU -3 RTU -2 ROOF E nE 15 CD 110 CD E E ELEVATOR LOBBY F F I F E E 5TH FLOOR 0011N TO EXIST. f/ FRCP IN 1st FLOOR (TYP) 4TH FLOOR 3rd FLOOR 2nd FLOOR EXISTING FIRE ALARM CONTROL PANEL (FACP) FIRST FLOOR PARTIAL ELECTRICAL RISER DIAGRAM STUB 6 INTO GLG SPACE WITH PLASTIC BUSHING AT END OF CONDUIT. 1' EC WITH PULLWIRE (TYP) DATA / VOICE OUTLET (TYP) VOICE OUTLET (TYP) "SUBJECT TO FIELD INSPECTION " N.T.S. VOC WITH PULLWIRE TO PBX ROOM. 3RD FLOOR 11(v vJ `P'J`;T COMPLY WITH: r: c. # (/ 10 FLORIDA E3UIL; I `i CODE PLUS LOCH L f,` IENDME'NTS BY: CLO. SPACE FIRE ALARM RISER DIAGRAM N.T.S. TELEPHONE \ DATA RISER DIAGRAM 4' -0' XS' -0' X 3/4' PLYWOOD PAINTED BLOCK TELEPHONE TERMINAL BOARD 5TH FLOOR N.T.S. diez archlffecture,* 0yy] 7430 sw 48th street miami, florida 33155 phone: (305) 663 -1970 fax: (305) 663 -2312 peter ©diezorchitecture.com pedro diez a 0008996 ENGINEERING CONSULTANT -PRV ENGINEERING, INC. 6452 NW 77 Ct., Miami, Ft. 33166 Ph 65.8,$627 Fx: 905.856.5955 Board of Professional En thrrYZttq OQQ09635 — 'qtr+- - --•-, Mechanical Engineer Electrical Engineer PROJECT ';o:�� ©s�'� G141 Office Building 5th Floor 6141 SUNSET DRIVE SOUTH MIAMI, FLORIDA PROJECT No. 04- 158.05 REVISIONS I GENERAL REVI510N 01 -27 -06 ELECTRICAL ROOM PLANS AND RISER DIAGRAM :�52 >+�.y:'�•;; 55rs»�; ;3��,')i� ,` <` Z.. „xxx�w, =�„ ;•• xx: _. SCALE: AS SHOWN DATE: JANUARY 4, 2006 E -5