06-113(2)-018DUCTWORK LEGEND 24x12 -NEW DUCTWORK, FIRST DIMENSION 15 SIDE SHOLLI UP DN - CHANGE OF ELEVATION IIIIIIIIIIII IIIIIIIIIII - FLEXIBLE DUCT - TRANSITION, CONCENTRIC - TRANSITION, ECCENTRIC 10x8 80 - TRANSITION, SQUARE -TO -ROUND - SQUARE THROAT ELBOW W /TURNING VANES - RADIU5 ELBOW i i RECTANGULAR/ROUND BRANCH TAKE -OFF OR ROUND /ROUND BRANCH TAKE -OFF - MANUAL BALANCING DAMPER } - RECTANGLE -TO -ROUND TAKE -OFF - STANDARD BRANCH TAKE -OFF - SPIN -IN TAKE -OFF 10 I I' 11111 - CEILING DIFFUSER, ROUND NECK (CEILING DIFFUSERS ARE 4 -WAY THROW UNO) i -ROUND DIFFUSER - CEILING RETURN - CEILING EXHAUST FAN - CEILING DIFFUSER, RECTANGULAR OR SQUARE NECK (CEILING DIFFUSERS ARE 4 -1.11AY THROW UNO) - SUPPLY REGISTER OR GRILLE (VERTICAL MOUNT, SIDEWALI � J -DOOR GRILLE UCH - UNDERCUT DOOR It - FLEXIBLE CONNECTION ® - REVISION REFERENCE 0 VAV UNIT SCHEDULE - DETAIL REFERENCE: TOP - DETAIL" M -� BOTTOM - DRAWING" SHOILN ON MIN. CFM - THERM05TAT /TEMPERATURE SENSOR p� - CONNECT TO EXISTING �- - DEMOLISH TO POINT INDICATED 0 VAV UNIT SCHEDULE PACKAGED ROOFTOP UNIT SCHEDULE MAX. CFM MIN. CFM INLET SIZE MAX. APD (1N WG) HEATING COIL KW STEPS V5 -2 -1 1250 1400 200 TAG7 MODEL SUPPLY AIR RETURN AIR CFM OUTSIDE AIR CFM EXT. S.P. GTH MBI1 TSC MB[I COMP. QTY. COMP. R L A FAN QTY FAN FLA H KW L FAN HP UNfT MCA UNIT MOCP VOLT/ WH WEIGHT LBS. RTU -1 (EXISTING) - - - - - - - - - - - - - - - - RTU -2 RLKA- A- 035 -JK -006 3000 2600 400 1.25 90.0 x73.4 1 14 1 2.8 10.5 1.5 39.0 50 20x/3 ro20 RTU -3 RLKA -A- 085 -,)K-006 3000 2600 400 1.25 90.0 63.4 1 14 2 2.8 105 1.5 39.0 50 200/3 020 RTU -4 RLKB- A- 120 -CL -000 4000 3200 800 1.5 125.0 90.0 2 20 2 3.0 14.0 3.0 59.0 10 2083/3 '1 RTU -5 RLKA- A- 035 -1oIK -006 3000 2x&00 400 1.25 90.0 ro3.4 1 14 2 2.8 10.5 1.5 39.0 50 200/3 820 NOTES: 1. ALL MODELS BASED ON UNITS MANUFACTURED BY: RHEEM 2. PROVIDE HOT -GAS BYPASS FOR ALL RTU'S 3. PROVIDE FACTORY ROOF CURB. COORDINATE WITH ARCHITECTURAL PLANS FOR EXACT THICKNESS OF ROOF INSULATION PRIOR TO ORDERING CURB. 4. PROVIDE 6 -ROW COOLING COIL WITH STAINLESS STEEL DRAIN PAN 5. ROOFTOP UNITS AND ASSOCIATED EXHAUST FANS SHALL SHUT DOWN UPON FIRE ALARM SIGNAL 6. PROVIDE SINGLE POINT ELECTRICAL CONNECTION 7. PROVIDE WITH 30% EFFICIENCY FILTERS IN COMPLIANCE WITH ASHRAE STANDARDS 52.1 -1992 8. AMBIENT DESIGN TEMPERATURE IS 105 F0 0 VAV UNIT SCHEDULE PLAN MARK DESIGN CFM MAX. CFM MIN. CFM INLET SIZE MAX. APD (1N WG) HEATING COIL KW STEPS V5 -2 -1 1250 1400 200 12 0.15 4.5 1 V5 -2 -2 515 800 95 8 0.15 2 1 V5 -2 -3 1350 1400 200 12 0.15 4.5 1 V5 -3 -1 1100 1200 125 10 0.15 3 1 V5-3-2 900 1200 125 10 0.15 3 1 V5-3-3 1000 1200 125 10 0.15 3 1 V5 -5 -1 1025 1200 125 10 0.15 3 1 V5 -5 -2 850 1200 125 10 0.15 3 1 V5 -5 -3 1250 1 1400 200 12 0.15 4.5 1 1500 -3000 1444 24x24 NOTES: 1 ALL MODELS BASED ON UNITS BY: METALAIRE 2 VERAY MODELS AND FINISH WITH ARCHITECT 3 VERIFY MOUNTING FRAMES WITH ARCHITECT 4 PROVIDE SQUARE TO ROUND ADAPTER FOR CG. 5 PROVIDE PLASTER FRAMES FOR ALL AIR DEVICES. NOTES: I. BASIS OF DESIGN: TITUS MODEL "DE5V" 2. ALL HEATING COILS UNDER 5K SHALL BE 203V /I. VERIFY WITH ELECTRICAL DRAWINGS AVAILABLE VOLTAGE PRIOR ORDERING A/C EQUIPMENT. 3. SEQUENCE OF CONTROL: ON A RISE OF ROOM TEMPERATURE THE ELECTRIC HEAT WILL DE- ENERGIZE. ON A FURTHER RISE OF ROOM TEMPERATURE THE VAV CONTROLLER WILL MODULATE COOL AIRFLOW FROM MINIMUM (SEE SCHEDULE) TO MAXIMUM SETTING, AIR DISTRIBUTION SCHEDULE Y. TAG MODEL AIR FLOW (CFM) DIFF SIZE DUCT SIZE ACCESSORIES/ CONSTRUCTION A LTC[) 0 - 25 6x6 4 "0 FINISH: SEE ARCH 016 OFFICE FIRE RATED ROOF /FLOOR CEILING ASSEMBLY 25 15 8x3 6 "0 O.B.D.: YES 180 SMOKE CONTROL w - 150 !0x10 64 MATERIAL: ALUMINUM 0 S !36-250 !2x!2 100 ROTUND NECK 1 251.400 111 12 "0 3164050 2040 144 51 24,24 16 110 RA RH 0.250 !0x.6 12 4 FINISH: SEE ARCH DA ER 250 -400 126 14 "0 DAMPER: YES 400 -600 124 16 "0 MATERIAL: ALUMINUM 600 -300 Ibxl6 Ibxlb ROUND OR 51 300 -1500 20x.20 20x20 NECK AS REQ'D 1500 -3000 1444 24x24 NOTES: 1 ALL MODELS BASED ON UNITS BY: METALAIRE 2 VERAY MODELS AND FINISH WITH ARCHITECT 3 VERIFY MOUNTING FRAMES WITH ARCHITECT 4 PROVIDE SQUARE TO ROUND ADAPTER FOR CG. 5 PROVIDE PLASTER FRAMES FOR ALL AIR DEVICES. IIVAC DESIGN REQ Y. NO DUCT SMOKE DETECTOR(S) /ES Ix PEOPLE DENSITY FIRE DAMPER (S) )/ 505 SMOKE DAMPER(S) 15 FIRE RATED ENCLOSURE 1� OFFICE FIRE RATED ROOF /FLOOR CEILING ASSEMBLY 1 20 FIRE STOPPING / Ix 180 SMOKE CONTROL 1,485 N/A J Lf CA 1.) 111 IVA 114 5411 Z[V11 v I km 1. CONNECTION TO EQUIPMENT SHALL BE VERIFIED WITH MANUFACTURER'S CERTIFIED DRAWINGS. TRANSITIONS TO ALL EQUIPMENT SHALL BE VERIFIED AND PROVIDED FOR EQUIPMENT FURNISI -QED. 2, VERIFY AT JOB SITE AVAILABLE VOLTAGE PRIOR TO ORDERING EQUIPMENT. 3. NOTIFY ARCHITECT OF ANY DISCREPANCIES BETWEEN CONSTRUCTION DOCUMENTS AND ACTUAL FIELD CONDITIONS. 4. DIMENSIONS SHALL BE FIELD - VERIFIED AND COORDINATED PRIOR TO PROCUREMENT OR FABRICATION. COORDINATE THE WORK WITH OTHER TRADES INVOLVED. FIELD MODIFICATIONS SUCH AS OFF5ET5 IN PIPING OR DUCTWORK (INCLUDING DIVIDED DUCTWORK) NEEDED DUE TO OBSTRUCTIONS OR INTERFERENCE SHALL BE PROVIDED AT NO ADDITIONAL COST, FOR PROJECTS INVOLVING RENOVATION, COORDINATE NEW WORK WITH EXISTING ELEMENTS SUCH AS THE BUILDING STRUCTURE AND ARCHITECTURAL FEATURES, SPRINKLER PIPING, LIGHTS, PLUMBING, AND ELECTRICAL CONDUIT. 5. DUCT CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE LATEST EDITION OF THE SMACNA HVAC DUCT CONSTRUCTION STANDARD. �. PROVIDE AIR TURNING VANES IN ALL 90 DEGREE RECTANGULAR DUCT ELBOWS. 1. DUCT SIZES AND ALL OPENINGS THROUGH BUILDING CONSTRUCTION 5HALL SUIT EQUIPMENT FURNISHED. 8. COORDINATE DIFFUSER, GRILLE AND REGISTER LOCATIONS WITH ARCHITECTURAL CEILING PLANS AND EQUIPMENT FROM ALL TRADES. 9, PROVIDE PROGRAMMABLE THERMOSTAT FOR ALL AIR HANDLING UNIT5. 10, LOCATE THERMOSTATS, TEMPERATURE SENSORS, 1HUMIDISTAT5, AND HUMIDITY SENSORS AT 48" ABOVE FINISHED FLOOR UNLE55 NOTED OTHERWISE, COORDINATE LOCATION5 WITH OTHER EQUIPMENT, FURNITURE, AND DOOR SWINGS. 11. ALL EQUIPMENT, DUCTWORK, ETC., SHALL BE SUPPORTED AS DETAILED AND /OR SPECIFIED. PROVIDE ADDITIONAL SUPPORTS AS REQUIRED TO PROVIDE A VIBRATION -FREE, RIGID INSTALLATION. 12. ALL DUCT 31ZE5 SHOWN ARE INSIDE CLEAR DIMENSIONS. 13, DAMPERS AND INSIDES OF DUCTS V15I5LE THROUGH GRILLES, REGISTERS AND DIFFUSERS SHALL BE PAINTED FLAT BLACK, 14. REFER TO TYPICAL DETAILS FOR PIPING AND INSTALLATION OF EQUIPMENT. 15, TRAPPED CONDENSATE DRAINS FROM ALL MECHANICAL EQUIPMENT SHALL BE PROVIDED FOR PROPER DRAINAGE TO SUIT EQUIPMENT FURNISHED. 14�,. AGCE55 PANELS IN DUCTWORK AND CEILINGS SHALL BE PROVIDED WHERE REQUIRED FOR OPERATION, BALANCING OR MAINTENANCE OF ALL MECHANICAL EQUIPMENT. 11. ALL DUCTWORK AND PIPING IS SHOWN SCHEMATICALLY. PROVIDE ALL TRANSITIONS, TURNING VANES, ELBOWS, FITTINGS, ETC., TO ALLOW SMOOTH FLOWS. 18, ALL SPLIT DUCT FITTINGS SHALL TRANSITION TO FULL 51ZE OF THE SUM OF BOTH BRANCHES, UPSTREAM OF SPLIT. 19, VERIFY MODELS AND FINISH WITH ARCHITECT PRIOR TO PURCHASING GRILLES, REGISTERS, DIFFUSERS, LOUVERS AND OTHER AIR DISTRIBUTION DEVICES. 20.PROVIDE FLEXIBLE DUCT CONNECTIONS ON ALL DUCTWORK CONNECTING TO EACH FAN, AIR HANDLING UNITS, AND FAN COIL UNIT5. 21. PROVIDE TRANSITIONS AT DIFFUSER NECKS AS REQUIRED TO MATCH SIZES OF FLEX DUCTS TO BE CONNECTED. 22. INTERRUPTIONS TO EXISTING SERVICES SHALL BE SCHEDULED FOR TIMES OTHER THAN NORMAL OPERATING HOURS (SUCH AS NIGHTS AND WEEKENDS). SUCH INTERRUPTIONS TO SERVICES SHALL NOT BE MADE WITHOUT THE PRIOR WRITTEN CONSENT OF THE OWNER'S REPRESENTATIVE AND PROPER COORDINATION WITH OTHER TRADES. PRE -WORK SHALL BE PERFORMED TO MAKE THE SHUTDOWN PERIOD AS BRIEF AS POSSIBLE, 23, MAINTAIN CLEARANCE OF A MINIMUM OF 7" BETWEEN DUCTWORK, PIPING, EQUIPMENT, ETC., AND ALL FIRE RATED AND FIRE /SMCKE RATED PARTITION5 TO ALLOW FOR INSPECTIONS OF RATED WALLS. 24. DUCT RUNOUTS TO DIFFUSERS SHALL MATCH THE SIZE OF THE DIFFUSER NECK. UNLE55 OTHERWISE NOTED, 25. ALL EQUIPMENT AND VALVE DRAINS SHALL BE INDEPENDENTLY PIPED FULL 51ZE TO THE NEAREST PLUMBING DRAIN. ASHRAE STANDARD 62 -2001 OUTDOOR AIR REQUIREMENTS FOR VENTILATION APPLICATION AREA (SF) PEOPLE/ 1000 SF CFM / PERSON CFM / SQ. FT. PEOPLE DENSITY O/A CFM RECEPTION 505 60 15 30 454 OFFICE 5,555 1 20 39 180 STORAGE / CORRIDORS 1,485 N/A N/A 0.05 0 S BREAK ROOM 145 5 20 1 20 TOTAL 1,690 10 1,262 diez architecture, inc. 7430 sw 48th street miami, florido 33155 phone: (305) 663 -1970 fax: (305) 663 -2312 peter @diezarchitecture.com pedro diez or 0008996 ENGINEERING CONSULTANT PRV ENGINEERING, INC. Mechanical - Electrical - Plamb'ng - Fire Protectior 6452 NW 77 Gt., Miao, , VV jl �k 05.859_627 - Fx: 305.856.5955 Board of Profess' 1i n sneers u� No.: 00009635 k - Mechanical Ii P. I�ope i{4� � �� PE 31326 •+ Eleqtri4l 1i Rigob�r�o�ej , �i PE 32076 04 • OL iw 4. w to P. R08ERT #VAL'DEB, f'l�v' PE #: 31326 G141 Office Building 5th Floor 6141 SUNSET DRIVE SOUTH MIAMI, FLORIDA PROJECT No. 04- 158.05 REVISIONS FIFTH FLOOR HVAC SCHEDULES NOTES AND LEGEND SCALE: AS SHOWN DATE: JANUARY 4, 2006 - T FalLf 6