Loading...
06-113(2)-010FINISH SCHEDULE FLOOR ROOM NAME FLOOR BASE WALLS CEILING F G, REMARKS UNDER CUT HDW. 1- U N 3z U > U to 0 FRAME DOOR O 3 I U A a. Q O O v WOOD SC WOOD � PAINT 0- 0O t7 SEE DOOR NOTE&I 14, 12 _ 2 COMMON CORRIDOR B 3' -0' 6' -8' 10 WOOD HC WOOD PAINT PAINT • - - SEE DOOR NOTES' 1" • 3 EXAM 1 • 13/4' WOOD SC REFER TO REFLECTED CEILING FOR ELEVATIONS WAITING ROOMS • • • EXAM 2 • 1 3/4' WOOD SC REFER TO REFLECTED CEILING FOR ELEVATIONS RECEPTIONS • • _ 5 • • 13/8' WOOD HC REFER TO REFLECTED CEILING FOR ELEVATIONS WORK AREA • • 6 OFFICE 2 • • REFER TO REFLECTED CEILING FOR ELEVATIONS INTERIOR CORRIDOR • • 1 • • REFER TO REFLECTED CEILING FOR ELEVATIONS REFER TO REFLECTED CEILING FOR ELEVATIONS DOCTORS • • _J • 8 OFFICE 4 • OFFICES • • • 9 EXAM 3 • REFER TO REFLECTED CEILING FOR ELEVATIONS WOOD SC EXAMS • • • 10 EXAM 4 • REFER TO REFLECTED CEILING FOR ELEVATIONS SLEEP • • • 11 DOCTOR 1 • REFER TO REFLECTED CEILING FOR ELEVATIONS -- f>' EXAM 313 • • • 12 • REFER TO REFLECTED CEILING FOR ELEVATIONS LOUNGE • • • • EXAM 6 REFER TO REFLECTED CEILING FOR ELEVATIONS a: FILE ROOM • • • • 14 DOCTOR 2 REFER TO REFLECTED CEILING FOR ELEVATIONS GYM • • • • 15 EXAM 1 REFER TO REFLECTED CEILING FOR ELEVATIONS STORAGE • • • • 16 EXAM 8 REFER TO REFLECTED CEILING FOR ELEVATIONS MEN • • • • 11 DOCTOR 3 REFER TO REFLECTED CEILING FOR ELEVATIONS WOMEN • • • • 18 REFER TO REFLECTED CEILING FOR ELEVATIONS RESTROOMS • 13/6, WOOD HC • • • 19 EXAM 9 REFER TO REFLECTED CEILING FOR ELEVATIONS BATHROOMS • 1 3/4' WOOD SC • • • 20 MOISTURE RE515TANT GYP. BD. CEILNG B JANITOR ROOM V -0' • WOOD Sc METAL PAINT PAINT • • 21 WOMEN B 3' -0' 6' -8' • WOOD SC WOOD PAINT REFER TO REFLECTED CEILING FOR ELEVATIONS ELECTRICAL ROOMS • SEE DOOR NOTES 1 22 MEN • 3' -0' 6' -8' • WOOD Sc WOOD PAINT PAINT • L REFER TO REFLECTED CEILING FOR ELEVATIONS L_ 23 FILE ROOM B 3' -0' 6' -8' 1 3/8' WOOD HC WOOD PAINT PAINT 24 — - - WINDOW NOTES I. FIELD VERIFY ALL OPENINGS PRIOR TO ORDERING WINDOWS. 2. INTERIOR WINDOWS TO BE 1/4" CLEAR CATEGORY 2 TEMPERED GLASS IN ALUM FRAMES, FOR INTERIOR APPLICATIONS. 3. SUBMIT SHOP DRAWIN65 OF ALL WINDOWS, TO ARCHITECT FOR REVIEW. FINISH NOTES: I. ALL GYP. BOARD SHALL BE TAPED, SPACKLED AND 5AN1;1ED SMOOTH TO RECEIVE TWO GOATS OF SEMI GLOSS INTERIOR LATEX PAINT. COLOR SELECTED BY DEVELOPER. 2. ALL FLOORING TO BE SELECTED BY DEVELOPER. 3. ACGOUSTICAL CEILNG TO BE ARMSTRONG 2' X 2' ON WHITE 15116" GRID, GEORGIAN TEGULAR STYLE OR APPROVED EQUAL. 4. SUBMIT 5AMPLF-5 OF TILES TO TENANT d VGT TO TENANT FOR REVIEW. 5. PROVIDE CARPET REDUCERS AT ALL CHANGE OF MATERIAL LOCATIONS. 6. PROVIDE A I" WIDE 5OL112 COLOR VINYL STRIP (D ALL CORRIDOR DOOR LOCATIONS WHERE FLOORING MATERIALS CHANGE. -1. INTERIOR FINISHES SHALL BE OF CLASS B. FLAMESPREAD 26 -15, SMOKE DEVELOPED 0 -450. TYPICAL. 8. WOOD DOORS TO BE PAINTED FINISH. 11. CERAMIC TILE WORK ® TOILETS TO HAVE COVED BASES AND ASSOCIATED TRIM. TENANT TO SELECT COLOR. 10. PROVIDE A 2" WIDE MARBLE THRESHOLD ® DOORS FROM TOILETS TO CORRIDOR AND @ LOBBY TO HALLWAY. PARTITION LEGEND W -1 EX15TINO 8" GONG. BLOCK WALL PROVIDE 5/8" GYP. BD. OVER 7/8" METAL FURRING @ 24" O.G. TO q' -6" A.F.F. ® INTERIOR W/ ALFOIL R -4.2 INSULATION TO UNDERSIDE OF DECK. P -I NEW 3 5/8" 25 GA METAL STUDS @ 24" O.G. W/ 5/8" GYP. BD. ® EACH SIDE TO q' -6" A.F.F. PROVIDE 4" THICK FIBERGLASS INSULATION WHERE SHOWN IN PLANS. PROVIDE 20 GA STUDS @ PHONE ROOMS t WHERE CABINETRY 15 SUPPORTED. PARTITION TO BE BRACED TO STRUCTURE ABOVE ® 4' -0" O.G. P -2 NEW I HR. FIRE RATED PARTITION 3 5 /8" 25 GA METAL STUDS ® 24" O.G. W/ ONE FULL LENGTH LAYER OF 5/8" TYPE "X" GYP. BD. APPLIED VERTICALLY WITH I" LONG #6 DRYWALL 50REW5 TO EACH SIDE. SCREWS ARE 8" O.G. ® PERIMETER AND 12" O.G. AT THE INTERMEDIATE STUDS. UL #465. PROVIDE A STENCILED SIGN ® 15-0" O.G. ABOVE CEILING STATING "FIRE AND SMOKE BARRIER PROTECT ALL OPENIGNS:. I" LETTERS ALONG FIRE RATED PARTIIONS. P -3 NEW 6" 25" GYP. B GA METAL 5TUD5 @ 24" O.G. W/ 5 /8D. ® EACH 51DE TO I' -6" A.F.F. VERIFY MOUNTING OF CABINETS, COUNTERTOPS, ETC. 8 PROVIDE 20 GA 5TUD5 AND 12 GAUGE ANCHOR PLATES BETWEEN STUDS THE LENGTH OF THE ITEM. 4" SOUND INSULATION @ WALL5 EHERE NOTED ON PLANS. P -4 NEW MIN. 3 5/8" 25 GA METAL STUDS ® 24" O.G. W/ 5 /8" GYP. BD. EACH SIDE TO Q' -6" A.F.F. ® ONE 51DE AND TIGHT TO 5TRUGTUREABOVE ® CORRIDOR SIDE, PROVIDE 4" THICK FIBERGLASS INSULATION WHERE SHOWN IN PLANS. PROVIDE 20 GA STUDS @ PHONE ROOMS $ WHERE CABINETRY 15 SUPPORTED. CAULK AND SEAL AS REQUIRED ALONG WALLS, WINDOWS, STRUCTURE ABOVE AND ® ALL PENETRATIONS. PROVIDE A STENCILED SIGN @ 15' -0" O.G. ABOVE CEILING STATING "SMOKE BARRIER PROTECT ALL OPENIN65 ". I" LETTERS ALONG SMOKE BARRIER. P -5 FURR OUT WALL5 FOR PLUMBING W/ 6" 25 GA METAL 5TUDS ® 24" O.G. W/ 5/8" GYP. BD. ® INTERIOR SIDE A5 SHOWN ON PLANS. N GAM TA STUDS ®24 O.G. 5 8 GYP. BD. ®EACH -6 EW 3 5 8 25 METAL W/ / P / SIDE AND SOUND BATTING TO UNDERSIDE OF STRUCTURE ABOVE. PROVIDE 20 GA STUDS @ PHONE ROOMS ®EHER CABINETRY 15 SUPPORTED. CAULK AND SEAL AS REQUIRED ALONG WALLS, WINDOWS, STRUCTURE ABOVE AND ® ALL PENETRATIONS. PROVIDE A STENCILED SIGN ® I5' -0" O.G. ABOVE CEILING STATING "SMOKE BARRIER PROTECT ALL OPENIN65 ". I" LETTERS ALONG SMOKE BARRIER. CIE NOTE: REFER TO REFLECTED CEILING FOR ROOMS RECEIVING GYP. BD. SOFFIT E ELEVATIONS DOOR NOTES: I- ALL WOOD DOORS SHALL BE PAINTED SEMI GLOSS LATEX FINISH. 2- METAL FRAMES SHALL BE WELDED IN LIEU OF KNOCK DOWN AND PAINTED. COLOR SELECTED BY TENANT, SEMI GLOSS FINISH. 3- SUBMIT SHOP DRAWWG5 OF ALL DOORS t FRAMES TO ARCHITECT FOR REVIEW. 4- ALL DOORS AND HARDWARE SHALL COMPLY WITH SECURITY AND FORCED ENTRY REQUIREMENTS AND ALL OTHER REQUIREMENTS AND THE AMERICAN DISABILITIES ACT. 5- ALL HOLLOW METAL AND WOOD DOORS TO HAVE LATCHSET OR LOCKSET6, LEVER DESIGN BRUSHED S.S. FINISH. 6- ALL METAL AND SOLID CORE DOORS TO HAVE 111/2' PAIR OF 6TEEL HAGER HINGES FULL MORTISE 411/2' X 411/2'. 1- PROVIDE WALL DOOR STOP, HAGER MODEL 232W, STAINLESS STEEL AND FLOOR STOP HAGER MODEL 241F OR EQUAL. 8- INTERIOR STOREFRONT DOORS TO BE 1/4' CLEAR TEMPERED GLASS CATEGORY 2 IN WHITE ESP ALUM FRAMES W/ CONCEALED COSER t 6.6, OFFSET PUCH/ PULL HANDLES a EACH SIDE 1' m. SUBMIT SHOP DINGS OF ALL GLAZING SYSTEMS. '3- PROVIDE DOOR CLOSER a FIRE RATED DOORS. 10- SYMBOLS 0 - EXISTING FIRE RATED DOOR TO REMAIN. 11- DOOR TO BE I HR FIRE RATED. 12- DOORS TO HAVE TWO PAIR OF HWAVY DUTY HINGES W/ METAL OR WOOD FRAME. 13- UNDERCUT ALL TOILET ROOM DOORS 1'. 14- DOOR TO HAVE 180' HINGE. DOOR SCHEDULE: FIFTH FLOOR FLOOR MARK LOCATION DOOR ELEV. DOOR OPENING SIZE MATERIAL FINISH LABEL / FIRE RATING UNDER CUT HDW. REMARKS W. H. T. DOOR FRAME DOOR FRAME I WAITING ROOM A 2 -3' -0' V -0' 13/4' WOOD SC WOOD PAINT PAINT - - - SEE DOOR NOTE&I 14, 12 _ 2 WAITING ROOM B 3' -0' 6' -8' 1 3/8' WOOD HC WOOD PAINT PAINT - - - SEE DOOR NOTES' 1" 3 EXAM 1 13/4' WOOD SC 4 EXAM 2 1 3/4' WOOD SC _ 5 OFFICE 1 13/8' WOOD HC 6 OFFICE 2 1 OFFICE 3 _J 8 OFFICE 4 9 EXAM 3 1 3/4' WOOD SC 10 EXAM 4 11 DOCTOR 1 12 EXAM 5 13 EXAM 6 14 DOCTOR 2 15 EXAM 1 16 EXAM 8 11 DOCTOR 3 18 OUNG L E 13/6, WOOD HC 19 EXAM 9 1 3/4' WOOD SC 20 EXAM 9B B 3' -0' V -0' 13/4' WOOD Sc METAL PAINT PAINT SEE DOOR NOTES 2, 1, 12 21 WOMEN B 3' -0' 6' -8' 1 3/4' WOOD SC WOOD PAINT PAINT SEE DOOR NOTES 1 22 MEN B 3' -0' 6' -8' 13/41 WOOD Sc WOOD PAINT PAINT 23 FILE ROOM B 3' -0' 6' -8' 1 3/8' WOOD HC WOOD PAINT PAINT 24 CORRIDOR B 3' -0' 8' -0' 1 3/4' WOOD SC WOOD PAINT PAINT SEE DOOR NOTES 1, 12 25 ELECTRICAL ROOM B 3' -0' V -0' 1 3/4' WOOD SC WOOD PAINT PAINT SEE DOOR NOTES 1, 12 26 CORRIDOR B Y -0' V -0' 1 3/4' WOOD SC WOOD PAINT PAINT SEE DOOR NOTES 1,12 21 BATH 1 B 3' -0' V -8' 1 3/4' WOOD SC WOOD PAINT PAINT _ SEE DOOR NOTES 1 UJ 28 OFFICE 1 1 3/8' WOOD HC 29 OFFICE 2 30 OFFICE 3 31 SLEEP I 32 SLEEP 2 33 BATH 2 1 3/4' WOOD SC 34 SLEEP 3 1 3/6' WOOD HC 35 SLEEP 4 36 SLEEP 5 - -- 31 SLEEP - 38 GYM — 39 OFFICE 4 40 OFFICE 5 41 RESTROOM 1 3/4' WOOD SC 42 STORAGE 13/5, WOOD HC 43 WAITING ROOM 1 3/6' WOOD HC 44 WAITING ROOM B Y -0' V -0' 1 3/4' WOOD SC WOOD PAINT PAINT SEE DOOR NOTES 1, 12 45 WAITING ROOM B Y -0' V -0' 1 3/4' WOOD SC WOOD PAINT PAINT SEE DOOR NOTES 1, 12 46 RECEPTION B Y -0' 6' -8' 13/6, WOOD HC WOOD PAINT PAINT SEE DOOR NOTES 1 41 EXAM I B Y -0' V -8' 1 3/4' WOOD SC WOOD PAINT PAINT SEE DOOR NOTES 1 48 STORAGE I C 3' -0' 6' -8' - WO LOUVER WOOD PAINT PAINT - 49 EXAM 2 B Y -0' V -8' 1 3/4' WOOD SC WOOD PAINT PAINT SEE DOOR NOTES 1 50 51 52 OFFICE 1 OFFICE 2 EXAM 3 I 1 13/6, 1 3/6' 1 3/4' WOOD HC WOOD HC WOOD SC -t t 53 STORAGE 2 C 2 -3' -0' 6' -8' - WO LOUVER WOOD PAINT PAINT - 54 OFFICE 3 B Y -0' 6' -8' 13/6' WOOD HC WOOD PAINT PAINT SEE DOOR NOTES 1 55 OFFICE 4 1 1 3/6' WOOD HC 56 EXAM 4 1 3/4' WOOD SC 51 RESTROOM 2 58 RESTROOM 1 59 LOUNGE 8' -0' WOOD PAINT PAINT SEE DOOR NOTES 1, 12 60 ELECTRICAL ROOM 3' -0' 8' -0' WOOD PAINT PAINT 1 HR RATED SEE DOOR NOTES 1, 3, 12 61 JANITOR 2' -10' 8' -0' WOOD PAINT PAINT - SEE DOOR NOTES 1, 12 o RE6TROOM B Y -0' V -0' 1 3/4' WOOD SC WOOD PAINT PAINT - SEE DOOR NOTES 1, 12 F-11 B DOOR TYPE ELEVATIONS 1/4" APPROVEO WffAMI -DAi3E COUNTY FIRE FIRE ALARM., -.,,.. BLDra PERMIT_„ WATER MAIN E)(T. --- - FIRE SUPFiiESSION___._� : a��/::::.::....: ..................:.......... ............................... ti. :.. :. :.: »,....:331/1/:./ :r.3.:...::.... a diez arci 4 --1 j t h, :.'.lea" c . F. ''1/ e,., :, ,,,,/ `, c 7430 sW 48th street miami, florida 33155 phone: (305) 663 -1970 fax: (305) 663 -2312 peter ©diezarchitecture.com pedro diez or 0008996 ENGINEERING CONSULTANT G141 Office Building 5th Floor 6141 SUNSET DRIVE SOUTH MIAMI, FLORIDA PROJECT No. 04- 158.05 REVISIONS DOOR + FINISH SCHEDULES FOURTH FLOOR ae +r �+ k SCALE: AS,, t1bWN �'; DATE: JANUARY 4, 2006 w6ft