05-1856R-004Al
FINISH SCHEDULE
FLOOR
ROOM NAME
FLOOR
BASE
WALLS
CEILING
LC%
REMARKS
WOO D
PAINT
PAINT
0008996
ENGINEERING CONSULTANT
S E NOTES 9 1 6
SEE NOTES 1
N
O
U.
z
v
g
.,
z
SEE NOTES 1
N
U�
�
SEE NOTES 1
°•3
�
�
SEE NOTES 14, I6
K
C4
c�
Q
Q
in
0
Q
O
Q
O
SEE NOTES 14
U
Q
SEE NOTES 14
a>
U>
U
WW
SEE NOTES 14
a
S
SEE NOTES 1
to
W
a5
C�7
CORRIDORS
•
•
•
•
REFER TO REFLECTED CEILING FOR ELEVATIONS
ac
WAITING ROOM
•
•
•
•
•
REFER TO REFLECTED CEILING FOR ELEVATIONS
SEXAM
ROOMS
•
•
•
•
REFER TO REFLECTED CEILING FOR ELEVATIONS
u-
Q
MEN
•
•
•
•
REFER TO REFLECTED CEILING FOR ELEVATIONS
WOMEN
•
•
•
•
REFER TO REFLECTED CEILING FOR ELEVATIONS
LAB/DRUG OFFICE
•
•
•
•
REFER TO REFLECTED CEILING FOR ELEVATIONS
OFFICES
•
•
•
•
•
REFER TO REFLECTED CEILING FOR ELEVATIONS X
STORAGE
•
•
•
•
REFER TO REFLECTED CEILING FOR ELEVATIONS
BREAKROOM
•
•
}
•
•
REFER TO REFLECTED CEILING FOR ELEVATIONS
CONFERENCE ROOMS
•
•
•
•
REFER TO REFLECTED CEILING FOR ELEVATIONS
JANITOR ROOM
•
•
}
•
•
REFER TO REFLECTED CEILING FOR ELEVATIONS
PBX ROOM
L
•
-
•
-
SEE NOTES 1, 11
}
•
-
-
-
•
WINDOW NOTES
1. FIELD VERIFY ALL OPENINGS PRIOR TO ORDERING WINDOWS
2. INTERIOR WINDOWS TO BE 1/4' CLEAR CATEGORY 2 TEMPERED GLASS
IN ALUM FRAMES, FOR INTERIOR APPLICATIONS
3. SUBMIT SHOP DRAWINGS OF ALL WINDOWS, TO ARCHITECT FOR REVIEW
FINISH NOTES:
I. ALL GYP. BOARD SHALL BE TAPED, SPACKLED AND SANDED SMOOTH TO RECEIVE
TWO COATS OF SEMI GLOSS INTERIOR LATEX PAINT. COLOR SELECTED
BY DEVELOPER
2. ALL FLOORING t0 BE SELECTED BY DEVELOPER
3. AGCOUSTICAL CEILING TO BE ARMSTRONG OR EQUAL 2'x2' ON A WHITE 15/16' GRID,
GEORGIAN TEGULAR STYLE.
4. SUBMIT SAMPLES OF TILES TO ARCHITECT 4 VCT TO ARCHITECT FOR REVIEW
5. PROVIDE CARPET REDUCERS AT ALL CHANGE OF MATERIAL LOCATIONS
6. PROVIDE A I' WIDE SOLID COLOR VINYL STRIP is ALL CORRIDOR TO DOOR LOCATIONS
WHERE FLOORING MATERIALS CHANGE
1. INTERIOR FINISHES SHALL BE OF CLASS B. FLAMESPREAD 26 -15, SMOKE DEVELOPED
0 -450. TYPICAL
6. WOOD DOORS TO BE PAINTED FINISH.
S. CERAMIC TILE WORK a TOILETS TO HAVE COVED BASES AND ASSOCIATED TRIM. TENANT
TO SELECT COLOR,
10. PROVIDE A 2' WIDE MARBLE THRESHOLD ® DOORS FROM TOILETS TO CORRIDOR
AND a LOBBY TO HALLWAY.
PAMMON LEGEND
W -1 EXISTING W CONC. BLOCK WALL, PROVIDE 5/8'
GYP. BD. OVER 1/8' METAL FURRING a 24' OC. TD 9' -6' A.F.F. is
INTERIOR W/ ALFOIL R -4.2 INSULATION TO UNDERSIDE OF DECK
P -1 NEW 3 5/8' 25 GA METAL STUDS a 24' OC W/ 5/8' GYP. BD 9
EACH SIDE TO V -6' AFF., PROVIDE 4' THICK FIBERGLASS
INSULATION WHERE SHOUJN IN PLANS PROVIDE 20 GA STUDS
9 PHONE ROOMS 4 WHERE CABINETRY IS SUPPORTED,
PARTITION TO BE BRACED TO STRUCTURE ABOVE ® 4'•0' OC
P -2 NEW I HR FIRE RATED PARTITION 3 5/8'25 GA METAL STUDS
s 24' OC. W/ ONE FULL LENGTH LAYER OF 5/8' TYPE 'X'
GYP. BD APPLIED VERTICALLY WITH 1' LONG % DRYWALL
SCREWS TO EACH SIDE SCREWS ARE 8' O.G. is PERIMETER
AND 12' OC. AT THE INTERMEDIATE STUDS. UL • 465
P -3 NEW 6' 25 GA METAL STUDS a 24' OC W/ 5/8' GYP. BD 9
EACH SIDE TO 8' -6' AFF. VERIFY MOUNTING OF CABINETS,
COUNTERTOPS, ETC t PROVIDE 12 GAUGE ANCHOR PLATES
BETWEEN STUDS THE LENGTT OF THE ITEM. 4' SOUND
INSULATION s WALLS. WHERE NOTED.
P -4 NEW 15/8' 25 GA METAL STUDS s 24' OC W/ 5/8' GYP. BD e
EACH SIDE TO V -6' AFF.
P -5 NEW 3 5/8' 25 GA METAL STUDS 9 24' OC W/ 5/8' GYP. BD
4 SOUND BATTING TO UNDERSIDE OF STRUCTURE
P -6 NEW 3 5/8' 25 GA METAL STUDS a 24' OC W/ 5/8' GYP. BD a
INTERIOR SIDE TO 9' -6' A.F.F.
P -1 NEW 3 5/8'25 GA METAL STUDS a 24' OC W/ 5/8' GYP. BD
TO UNDERSIDE OF STRUCTURE
)K NOTE: REFER TO REFLECTED CEILING FOR ROOMS RECEIVING
GYP. BD. SOFFIT d ELEVATIONS
DOOR NOTES:
1- ALL WOOD DOORS SHALL BE PAINTED
SEMI GLOSS LATEX FINISH
2- NOT USED
3- SUBMIT SHOP DRAWINGS OF ALL DOORS 4 FRAMES TO ARCHITECT
FOR REVIEW
4- ALL DOORS AND HARDWARE SHALL COMPLY WITH SECURITY AND FORCED ENTRY
REQUIREMENTS AND ALL OTHER REQUIREMENTS AND THE AMERICAN DISABILITIES
ACT.
5- ALL HOLLOW METAL AND WOOD DOORS TO HAVE LATCHSET OR LOCKSETS, LEVER
DESIGN. BRUSHED SS FINISH.
6- ALL METAL AND SOLID CORE DOORS TO HAVE 1V2' PAIR OF STEEL HAGER
HINGES FULL MORTISE 02'4/2'
1- PROVIDE WALL DOOR STOP, HAGER MODEL 232W, STAINLESS STEEL AND FLOOR
STOP HAGER MODEL 241F OR EQUAL
8- INTERIOR STOREFRONT DOORS TO BE 1/4' CLEAR TEMPERED GLASS CATEGORY 2 IN WHITE ESP,
ALUM FRAMES, W/ CONCEALED CLOSER 4 SS OFFSET PUSH/ FULL HANDLES a EACH SIDE 1' P
SUBMIT SHOP OU65 OF ALL GLAZING SYSTEMS.
9- PROVIDE DOOR CLOSER s FIRE RATED DOORS
10- SYMBOL ®= EXISTING FIRE RATED DOOR TO REMAIN.
II- HINGES TO ALLOW FOR 180 DEGREE DOOR SWING. PROVIDE DOOR STOP a BOTH ENDS
OF SWING AS REQUIRED. CLOSER TO RETURN TO CLOSED POSITION.
12- DOOR TO BE I HOUR FIRE RATED
- 4' -0' - - TOW VE TUlO PAIR OF HINGES. - - - - - - - -
B- UNDERCUT ALL TOILET ROOM DORS 1'.
16- DOOR TO HAVE NO LOCKING DEVICES ON EITHER SIDE. DOOR NOT SUBJECT TO LOCKING.
c.
FI
01
C
DOOR TYPE ELEVATIONS 1/4
X
PHEDULE: THIRD FLOOR
TRIAL
FINISH
LABEL /
FIRE RATING
UNDER
CUT
HDW.
REMARKS
663 -2312
peter ®diezarchitecture.com
WOO D
PAINT
PAINT
0008996
ENGINEERING CONSULTANT
S E NOTES 9 1 6
SEE NOTES 1
SEE NOTES 16
SEE NOTES 1
SEE NOTES 1
SEE NOTES 14, I6
SEE NOTES 1
SEE NOTES 14
SEE NOTES 14
SEE NOTES 14
SEE NOTES 14
SEE NOTES 1
}
}
}
}
-
-
-
SEE NOTES 1, 11
}
-
-
-
SEE NOTES 1
r
r
r
r
r
r
r
r
r
r
r
r
SEE NOTES 13
r
SEE NOTES 13
r
SEE NOTES 13
r
SEE NOTES 13
}
SEE NOTES 13
}
-
-
SEE NOTE 11
r
r METAL
I HOUR
-
-
SEE NOTE 1, 9
WOOD
-
-
-
SEE NOTE 1
r
CATEGORY 2 SAFETY
GLAZING
TYPICAL DOUBLE
SWING DOOR
A
AS BUI!_TS
THE REVISIONS SHOWN ON THESE SET OF DRAWINGS HAVE BEEN COPIED FROM
THE CONTRACTOR'S AS -BUILT MARK UP SET. SUCH REVISIONS REFLECT
CHANGES AND FIELD COORDINATIONS DONE BY THE CONTRACTOR DURING
THE COURSE OF CONSTRUCTION.
DIEZ ARCHITECTURE, INC. IS NOT RESPONSIBLE FOR THE ACCURACY OF THE
INFORMATION CONTAINED HEREIN.
APPROWD BY
MIAWBADE COUNTY FIRE K
SPy�.__B DG. PERMIT
WATER AIN EXTISN
DATEq ,-
_ - - - - -- - --
Z
A. >a>
u re,
. ,
7430 sw 48th
street
miami, florida
33155
phone: (305)
663 -1970
fax: (305)
663 -2312
peter ®diezarchitecture.com
pedro diez, ra
president Or
0008996
ENGINEERING CONSULTANT
G141
Office Building
3rd Floor
6141 SUNSET DRIVE
SOUTH MIAMI, FLORIDA
PROJECT No. 04- 158.03
REVISIONS
10 11 -14 -2005
08-11-2006
DOOR + FINISH
SCHEDULES
THIRD FLOOR
9
:
. _•`'
SCALE: AS SHOWN
DATE: NOVEMBER 2. 2005
A7.0