05-1856R-003I
OCCUPANT LOAD AND
BUILDING TYPE
GRO55 AREA PER FLOOR 11,181 SOFT.
CODE d OCCUPANCY — 2004 FLORIDA BUILDING CODE
BU51NE55 GROUP B
OCCUPANT LOAD (1/100 5F.) 11,181/100 - 118
OCCUPANT LOAD (1/100 SF.) 4,129/100 = 42
BUILDING CONSTRUCTION TYPE —TYPE III PROTECTED
PLUMBING: FIXTURES REQUIRED AS PER F15C -P- 403.1, 5U51NE55
PER 11,181 SQ FT
3 WC
2 LAV
1 SERVICE SINK
2 DF
FLUM51NG FIXTURES PROVIDED ON THIRD FLOOR
AREA OF WORK ON THIRD FLOOR: 11,231 Sa FT.
4 WC (HC ACCE5515LE)
4 LAV (HC ACCESSIBLE)
1 SERVICE SINK
2 DF (HC ACCESSIBLE)
1 WC
1LAV
BUILDING WILL HAVE A FIRE ALARM AND A SPRINKLER SYSTEM
e•
0
THIRD FLOOR FIRE EXIT PLAN
SCALE: 3/16' - T-0'
A5 BUILT5
THE REV15IONS SHOWN ON THESE SET OF DRAWINGS NAVE BEEN COPIED FROM THE
CONTRACTOR'S AS- BUILT MARK UP SET. SUCH REVISIONS REFLECT CHANGES AND
FIELD COORDINATIONS DONE BY THE CONTRACTOR DURING THE COURSE OF
CONSTRUCTION.
DIEZ ARCHITECTURE, INC. IS NOT RESPONSIBLE FOR THE ACCURACY OF THE
INFOWATION CONTAINED HEREIN.
NOTE: THIRD FLOOR IS OCCUPIED
BY A SINGLE TENANT.
,,...._BLDG. PERW�`�
WATER MAIN EXT5NS
DATEyI`��1� RvO�,
,
a „� 3
dC3E ,,L`
7430 sw 48th street
miami, florida 33155
phone: (305) 663 -1970
fax: (305) 663 -2312
peter®diezarchitecture.com
pedro diez, ra
president ar 0008996
ENGINEERING CONSULTANT
6747
Office Building
3rd Floor
6141 SUNSET DRIVE
SOUTH MIAMI, FLORIDA
='M' ii,:r..r:: ^ i:,. <,.rM=a��,'.yx;:,h„`
PROJECT No. 04- 158.03
REVISIONS
A 11-14-2005
20 08 -11 -2006
THIRD FLOOR
FIRE EXIT PLAN
SCALE: AS SHOWN
DATE: NOVEMBER 2, 2005
A4.0
•j.
mW:S
a „� 3
dC3E ,,L`
7430 sw 48th street
miami, florida 33155
phone: (305) 663 -1970
fax: (305) 663 -2312
peter®diezarchitecture.com
pedro diez, ra
president ar 0008996
ENGINEERING CONSULTANT
6747
Office Building
3rd Floor
6141 SUNSET DRIVE
SOUTH MIAMI, FLORIDA
='M' ii,:r..r:: ^ i:,. <,.rM=a��,'.yx;:,h„`
PROJECT No. 04- 158.03
REVISIONS
A 11-14-2005
20 08 -11 -2006
THIRD FLOOR
FIRE EXIT PLAN
SCALE: AS SHOWN
DATE: NOVEMBER 2, 2005
A4.0
•j.