05-1856-014DUCTWORK LEGEND 2412 UP DIN IIIIIIIIIIIIIIIIIIIIIII 10X8 0 I VIII (� LIC E -NEW DUCTWORK, FIRST DIMENSION IS SIDE SHOILN - CHANGE OF ELEVATION - FLEXIBLE DUCT - TRANSITION, CONCENTRIC - TRANSITION, ECCENTRIC - TRANSITION, SQUARE -TO -ROUND - SQUARE THROAT ELBOW W/TURNING VANES - RADIUS ELBOW - RECTANGULAR/ROUND BRANCH TAKE -OFF OR ROUND/ROUND BRANCH TAKE -OFF - MANUAL BALANCING DAMPER - RECTANGLE -TO -ROUND TAKE -OFF - STANDARD BRANCH TAKE -OFF - SPIN -IN TAKE -OFF - CEILING DIFFUSER ROUND NECK (CEILING DIFFUSERS ARE 4 -WAY THROW UNO) -ROUND DIFFUSER - CEILING RETURN - CEILING EXHAUST FAN - CEILING DIFFUSER RECTANGULAR OR SQUARE NECK (CEILING DIFFUSERS ARE 4 -WAY THROW UNO) - SUPPLY REGISTER OR GRILLE (VERTICAL MOUNT, SIDEWALL) -DOOR GRILLE - UNDERCUT DOOR - FLEXIBLE CONNECTION -DUCT SMOKE DETECTOR -FIRE DAMPER W /ACCESS PANEL -DUCT MOUNTED MOTORIZED DAMPER - DAMPER TO BE CONTROLLED BY -A DUCT MOUNTED PRESSURE SENSOR - REVISION REFERENCE - DETAIL REFERENCE: TOP - DETAIL! BOTTCM- DRAWNGO SHOWN ON - THEWOSTAT/TEMPERATURE SENSOR - CONNECT TO EXISTING - DEMOLISH TO POINT INDICATED AIR COOLED CONDENSING UNIT SCHEDULE AIR HANDLING UNIT SCHEDULE (DX SPLIT) MODEL NO. COOLING CAPACITY ELECTRICAL DATA PIPING DATA SEER WEIGHT (LBS) GTC (mbh) TSC (mbh) AMB. TEMP ENT /LVG CONDITIONS ELECTRICAL DATA N0. FANS PLAN MCA MODEL MATCHING OUTSIDE TOTAL AIR EXT. ENT ENT LVG LVG HEATING FAN 1 MAX VOLT/ WEIGHT 41.0 80 208/3 1 -1 /6 1/2 1 MARK 5013 N0. COND. UNIT AIR CFM CFM S.P. PH LBS. RTU -1 I RLKA -A- 085-JK -006 3000 1 2600 FLA 1.5 1 XXX XXX 2 1 XX 1 2 1 XX I 105 1 2.0 46.0 DB WB DB W13 KW /STEPS H.P. 2040 FUSE PHASE (LBS) AHU -3 -1 CU -3 -3 RHGE -ICOZL CU -3 -1 450 4000 125 18 65 56 55 - 3 15 15 208/3 341 AHU -3 -2 CU -3 -2 UNITS AND ASSOCIATED EXHAUST FANS SHALL SHUT DOWN UPON FIRE ALARM SIGNAL 6. PROVIDE SINGLE POINT ELECTRICAL CONNECTION - 15 15 AHU -3 -3 DESIGN TEMPERATURE IS 105 F ° CU -3 -3 ri ri ri ri ri ©� - AHU -3 -4 W CU -3 -4 CU -3 -F C5-002 22.2 16.6 - - - - - 11.1 35.0 208/1 3/4 No AHU -3 -F O 00AOOOA00 CU -3 -F 190 800 052 80 61 55 538 10 1/3 36.9 45 208/1 151 TOTAL O/A = 1,990 NOTES: 1. MODEL NUMBER OF AHU -3 -F IS BASED ON AAON ALL OTHERS ARE BASED ON RHEEM. 2. AIR HANDLING UNIT AND ASSOCIATED EXHAUST FAN SHALL SHUT DOWN UPON FIRE ALARM SIGNAL, DUCT SMOKE DETECTOR SENSING PRODUCTS OF COMBUSTION OR MANUAL ACTUATION OF AHU OR EXHAUST STARTER TO "OFF" POSITION. 3. PROVIDE WITH 30% EFFICIENCY FILTERS IN COMPLIANCE WITH ASHRAE STANDARD 52 -76. 4. HEAD PRESSURE CONTROLLER FOR OPERATION IN AMBIENT TEMPERATURES DOWN TO 30 'F. 5. PROVIDE SINGLE POINT ELECTRICAL CONNECTION. STARTER, RELAY, HEATING ELEMENT AND CONTROLS TO BE PART OF PACKAGED UNIT. 6. AMBIENT DESIGN TEMP IS 95 'F. 7. PROVIDE DUCT MOUNTED SUPPLY AIR TEMPERATURE SENSOR TO CONTROL LEAVING AIR TEMPERATURE. AIR COOLED CONDENSING UNIT SCHEDULE PLAN MARK MODEL NO. COOLING CAPACITY ELECTRICAL DATA PIPING DATA SEER WEIGHT (LBS) GTC (mbh) TSC (mbh) AMB. TEMP SAT SUCT TEMP NO. COMP. COMP. RLA(EA) N0. FANS COND. FLA(EA) MCA MAX FUSE VOLT/ PHASE RS O.D. RL O.D. N0. CIRC. CU -3 -1 BAWD- 100 -CAZ 126.5 893 95 40 1 33.6 2 22 41.0 80 208/3 1 -1 /6 1/2 1 9.0 5013 CU -3 -2 KW HP MCA MOCP PH LBS. RTU -1 I RLKA -A- 085-JK -006 3000 1 2600 1 400 1.5 1 XXX XXX 2 1 XX 1 2 1 XX I 105 1 2.0 46.0 I 60 I 208/3 620 NOTES: WO -600 2040 1. ALL MODELS BASED ON UNITS MANUFACTURED BY: RHEEM 1500 -3000 CU -3 -3 2. PROVIDE HOT -GAS BYPASS AND MODULATING HOT GAS REHEAT FOR RTU -OA 3. PROVIDE FACTORY ROOF CURB. COORDINATE WITH ARCHITECTURAL PLANS FOR EXACT THICKNESS OF ROOF INSULATION PRIOR TO ORDERING CURB. 4. PROVIDE 6 -ROW COOLING COIL WITH STIANLESS STEEL DRAIN PAN 5. ROOFTOP UNITS AND ASSOCIATED EXHAUST FANS SHALL SHUT DOWN UPON FIRE ALARM SIGNAL 6. PROVIDE SINGLE POINT ELECTRICAL CONNECTION 7. PROVIDE CU -3 -4 8. AMBIENT DESIGN TEMPERATURE IS 105 F ° ri ri ri ri ri ri ri ©� CU -3 -F C5-002 22.2 16.6 - - - - - 11.1 35.0 208/1 3/4 No 13 282 NOTES: 1. MODEL NUMBERS FOR UNITS CU -3 -1 THRU CU -3 -4 ARE BASED ON RHEEM; UNIT CU -3 -F IS AAON. 2. REFRIGERANT PIPING SIZED BASED ON USING LONG RADIUS ELBOWS EXCEPT FOR SUCTION LINE TRAP AT CONDENSING UNIT. 3. TABULATED REFRIGERATION CAPACITIES ARE REQUIRED CAPACITIES AT ENTERING, LEAVING AND CONDENSING TEMPERATURES INDICATED. 4. PROVIDE HOT GAS BY -PASS TO ALLOW FOR UNIT CAPACITY CONTROL MODULATION. FAN SCHEDULE PLAN MARK MODEL NO. MFG. TYPE CFM STATIC PRESS. FAN RPM MOTOR VOLT/ PHASE DRIVE TYPE FAN SERVICE ACCESSORIES RPM P/ EF -1 10OClODH LOREN -COOK CENTRIFUGAL 300 0.25 1050 1050 &/99 115/1 DIRECT BATHROOMS BIRD SCREEN; SPEED CONTROL; FACTORY 12"H ROOF CURB EF -2 90SQN -12D LOREN -COOK CENTRIFUGAL 300 0.55 1600 1600 )6/137 115/1 DIRECT PROCEDURE RM. ACID COAT; EXPLOSION PROOF KW HP MCA MOCP PH LBS. RTU -1 I RLKA -A- 085-JK -006 3000 1 2600 1 400 1.5 1 XXX XXX 2 1 XX 1 2 1 XX I 105 1 2.0 46.0 I 60 I 208/3 620 NOTES: NOTES: L BASIS OF DESIGN: TITUS MODEL "DESV" 2. ALL HEATING: COILS UNDER 5K SHALL BE 208VA VERIFY WITH ELECTRICAL DRAWINGS AVAILABLE VOLTAGE PRIOR ORDERING A/C EQUIPMENT. 3. SEQUENCE OF CONTROL: ON A RISE OF ROOM TEMPERATURE THE ELECTRIC HEAT WILL DE- ENERGIZE. ON A FURTHER RISE OF ROOM TEMPERATURE THE VAV CONTROLLER WILL MODULATE COOL AIRFLOW FROM MINIMUM (SEE SCHEDULE) TO MAXIMUM SETTING. AIR DISTRIBUTION TAG PACKAGED ROOFTOP UNIT SCHEDULE AIR FLOW DUCT j ACCESSORIES PEOPLE DENSITY P (CFM) SIZE TAG A MODEL SUPPLY RETURN I OUTSIDE I EXT. I GTH I TSC COMP. COMP FAN FAN HEATER I. FA UNIT UNIT VOLT / WEIGHT I 12x12 ROUND NECK 5 AIR AIR CFM AIR CFM S.P. MBH MBH QTY. RLA QTY FLA KW HP MCA MOCP PH LBS. RTU -1 I RLKA -A- 085-JK -006 3000 1 2600 1 400 1.5 1 XXX XXX 2 1 XX 1 2 1 XX I 105 1 2.0 46.0 I 60 I 208/3 620 NOTES: WO -600 2040 1. ALL MODELS BASED ON UNITS MANUFACTURED BY: RHEEM 1500 -3000 2424 2. PROVIDE HOT -GAS BYPASS AND MODULATING HOT GAS REHEAT FOR RTU -OA 3. PROVIDE FACTORY ROOF CURB. COORDINATE WITH ARCHITECTURAL PLANS FOR EXACT THICKNESS OF ROOF INSULATION PRIOR TO ORDERING CURB. 4. PROVIDE 6 -ROW COOLING COIL WITH STIANLESS STEEL DRAIN PAN 5. ROOFTOP UNITS AND ASSOCIATED EXHAUST FANS SHALL SHUT DOWN UPON FIRE ALARM SIGNAL 6. PROVIDE SINGLE POINT ELECTRICAL CONNECTION 7. PROVIDE WITH 30% EFFICIENCY FILTERS IN COMPLIANCE WITH ASHRAE STANDARDS 52.1 -1992 8. AMBIENT DESIGN TEMPERATURE IS 105 F ° ri ri ri ri NOTES: L BASIS OF DESIGN: TITUS MODEL "DESV" 2. ALL HEATING: COILS UNDER 5K SHALL BE 208VA VERIFY WITH ELECTRICAL DRAWINGS AVAILABLE VOLTAGE PRIOR ORDERING A/C EQUIPMENT. 3. SEQUENCE OF CONTROL: ON A RISE OF ROOM TEMPERATURE THE ELECTRIC HEAT WILL DE- ENERGIZE. ON A FURTHER RISE OF ROOM TEMPERATURE THE VAV CONTROLLER WILL MODULATE COOL AIRFLOW FROM MINIMUM (SEE SCHEDULE) TO MAXIMUM SETTING. AIR DISTRIBUTION TAG I MODEL AIR FLOW DUCT j ACCESSORIES PEOPLE DENSITY P (CFM) SIZE - A LTCD 0-25 6X6 FINISH: SEE ARCH DUrs -------- - - - - -- FIRE RATED ROOF /FLOOR CEILING ASSEMBLY - -- 25-15 8x8 ODDS YES --------------- SMOKE CONTROL 80 - 150 10x10 MATERIAL: ALUM" 0.05 0 136 -250 12x12 ROUND NECK 5 20 251 -400 16x16 40 TOTAL 11,211 316 -650 2040 11 1,145 501 -900 2424 RA RH 0 -250 10x6 FINISH: SEE ARCH DUXs ER 250 -400 12x8 DAMPER YES 400400 12x12 o ri • ri o ri ri ri ©� WO -600 2040 1500 -3000 2424 ri ri ri ri ri ri ri ©� NOTES: L BASIS OF DESIGN: TITUS MODEL "DESV" 2. ALL HEATING: COILS UNDER 5K SHALL BE 208VA VERIFY WITH ELECTRICAL DRAWINGS AVAILABLE VOLTAGE PRIOR ORDERING A/C EQUIPMENT. 3. SEQUENCE OF CONTROL: ON A RISE OF ROOM TEMPERATURE THE ELECTRIC HEAT WILL DE- ENERGIZE. ON A FURTHER RISE OF ROOM TEMPERATURE THE VAV CONTROLLER WILL MODULATE COOL AIRFLOW FROM MINIMUM (SEE SCHEDULE) TO MAXIMUM SETTING. AIR DISTRIBUTION TAG I MODEL AIR FLOW DUCT j ACCESSORIES PEOPLE DENSITY FIRE DAMPER (S) (CFM) SIZE j CONSTRUCTIO A LTCD 0-25 6X6 FINISH: SEE ARCH DUrs -------- - - - - -- FIRE RATED ROOF /FLOOR CEILING ASSEMBLY - -- 25-15 8x8 ODDS YES --------------- SMOKE CONTROL 80 - 150 10x10 MATERIAL: ALUM" 0.05 0 136 -250 12x12 ROUND NECK 5 20 251 -400 16x16 40 TOTAL 11,211 316 -650 2040 11 1,145 501 -900 2424 RA RH 0 -250 10x6 FINISH: SEE ARCH DUXs ER 250 -400 12x8 DAMPER YES 400400 12x12 MATERIAL: ALUMINUM 600 -800 Ibxlb WO -600 2040 1500 -3000 2424 NOTES: 1 ALL MODELS BASED ON UNITS BY: METALAIRE 2 VERFIY MODELS AND FINISH WITH ARCHITECT 3 VERIFY MOUNTING FRAMES WITH ARCHITECT 4 PROVIDE SQUARE TO ROUND ADAPTER FOR CG. 5 PROVIDE PLASTER FRAMES FOR ALL AIR DEVICES. HVAC DESIGN REQ YES NO DUCT SMOKE DETECTOR(S) CFM / SQ. FT. PEOPLE DENSITY FIRE DAMPER (S) RECEPTION 418 SMOKE DAMPER(S) 15 FIRE RATED ENCLOSURE - 315 OFFICE -------- - - - - -- FIRE RATED ROOF /FLOOR CEILING ASSEMBLY - -- -- - - - - -- - -------------- - - - - -- FIRE STOPPING - -- --------------- SMOKE CONTROL 1310 N/A GENERAL NOTES: 1. CONNECTION TO EQUIPMENT SHALL BE VERIFIED WITH MANUFACTURER'S CERTIFIED DRAWINGS. TRANSITIONS TO ALL EQUIPMENT SHALL BE VERIFIED AND PROVIDED FOR EQUIPMENT FURNISHED. 2. VERIFY AT JOB SITE AVAILABLE VOLTAGE PRIOR TO ORDERING EQUIPMENT. 3. NOTIFY ARCHITECT OF ANY DISCREPANCIES BETWEEN CONSTRUCTION DOCUMENTS AND ACTUAL FIELD CONDITIONS. 4. DIMENSIONS SHALL BE FIELD - VERIFIED AND COORDINATED PRIOR TO PROCUREMENT OR FABRICATION. COORDINATE THE WORK WITH OTHER TRADES INVOLVED. FIELD MODIFICATIONS SUCH AS OFFSETS IN PIPING OR DUCTWORK (INCLUDING DIVIDED DUCTWORK) NEEDED DUE TO OBSTRUCTIONS OR INTERFERENCE SHALL BE PROVIDED AT NO ADDITIONAL COST. FOR PROJECTS INVOLVING RENOVATION, COORDINATE NEW WORK WITH EXISTING ELEMENTS SUCH AS THE BUILDING STRUCTURE AND ARCI-IITE:CTURAL FEATURES, SPRINKLER PIPING, LIGHTS, PLUMBING, AND ELECTRICAL CONDUIT. 5. DUCT CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE LATEST EDITION OF THE SMACNA HVAC DUCT CONSTRUCTION STANDARD. 6. PROVIDE AIR TURNING VANES IN ALL 50 DEGREE RECTANGULAR DUCT ELBOWS. 1. DUCT SIZES AND ALL OPENINGS THROUGH BUILDING CONSTRUCTION SHALL SUIT EQUIPMENT FURNISHED. 8. COORDINATE DIFFUSER, GRILLE AND REGISTER LOCATIONS WITH ARCHITECTURAL CEILING PLANS AND EQUIPMENT FROM ALL TRADES. c3. PROVIDE PROGRAMMABLE THERMOSTAT FOR ALL AIR HANDLING UNITS. 10. LOCATE THERMOSTATS, TEMPERATURE SENSORS, HUMIDISTATS, AND HUMIDITY SENSORS AT 48" ABOVE FINISHED FLOOR UNLESS NOTED OTHERWISE. COORDINATE LOCATIONS WITH OTHER EQUIPMENT, FURNITURE, AND DOOR SWINGS. 11. ALL EQUIPMENT, DUCTWORK, ETC., SHALL BE SUPPORTED AS DETAILED AND /OR SPECIFIED. PROVIDE ADDITIONAL SUPPORTS AS REQUIRED TO PROVIDE A VIBRATION -FREE, RIGID INSTALLATION. 12. ALL DUCT SIZES SHOWN ARE INSIDE CLEAR DIMENSIONS. 13. DAMPERS AND IN5IDES OF DUCTS VISIBLE THROUGH GRILLES, REGISTERS AND DIFFUSERS 5HALL BE PAINTED FLAT BLACK. 14. REFER TO TYPICAL DETAILS FOR PIPING AND INSTALLATION OF EQUIPMENT. 15. TRAPPED CONDENSATE DRAINS FROM ALL MECHANICAL EQUIPMENT SHALL BE PROVIDED FOR PROPER DRAINAGE TO SUIT EQUIPMENT FURNISHED. 16. ACCESS PANELS IN DUCTWORK AND CEILINGS SHALL BE PROVIDED WHERE REQUIRED FOR OPERATION, BALANCING OR MAINTENANCE OF ALL MECHANICAL EQUIPMENT. 11. ALL DUCTWORK AND PIPING 15 SHOWN SCHEMATICALLY. PROVIDE ALL TRANSITIONS, TURNING VANES, ELBOWS, FITTINGS, ETC., TO ALLOW SMOOTH FLOWS. 18. ALL SPLIT DUCT FITTINGS SHALL TRANSITION TO FULL 51ZE OF THE SUM OF BOTH BRANCHES, UPSTREAM OF SPLIT. 19. VERIFY MODELS AND FINISH WITH ARCHITECT PRIOR TO PURCHASING GRILLES, REGISTERS, DIFFUSERS, LOUVERS AND OTHER AIR DISTRIBUTION DEVICES. 20.PROVIDE FLEXIBLE DUCT CONNECTIONS ON ALL DUCTWORK CONNECTING TO EACH FAN, AIR HANDLING UNITS, AND FAN COIL UNITS. 21. PROVIDE TRANSITIONS AT DIFFUSER NECKS AS REQUIRED TO MATCH SIZES OF FLEX DUCTS TO BE CONNECTED. 22. INTERRUPTIONS TO EXISTING SERVICES SHALL BE SCHEDULED FOR TIMES OTHER THAN NORMAL OPERATING HOURS (SUCH AS NIGHTS AND WEEKENDS). SUCH INTERRUPTIONS TO SERVICES SHALL NOT BE MADE WITHOUT THE PRIOR WRITTEN CONSENT OF THE OWNER'S REPRESENTATIVE AND PROPER COORDINATION WITH OTHER TRADES. PRE -WORK SHALL BE PERFORMED TO MAKE THE SHUTDOWN PERIOD AS BRIEF AS POSSIBLE. 23. MAINTAIN CLEARANCE OF A MINIMUM OF 6" BETWEEN DUCTWORK, PIPING, EQUIPMENT, ETC., AND ALL FIRE RATED AND FIRE /SMOKE RATED PARTITIONS TO ALLOW FOR INSPECTIONS OF RATED WALLS. 24. DUCT RUNOUTS TO DIFFUSERS SHALL MATCH THE SIZE OF THE DIFFUSER NECK. UNLESS OTHERWISE NOTED, 25. ALL EQUIPMENT AND VALVE DRAINS 514ALL BE INDEPENDENTLY PIPED FULL 51ZE TO THE NEAREST PLUMBING DRAIN. ASHRAE STANDARD 62 -2001 OUTDOOR AIR REQUIREMENTS FOR VENTILATION APPLICATION AREA (SF) PEOPLE / 1000 SF CFM / PERSON CFM / SQ. FT. PEOPLE DENSITY 0/A CFM RECEPTION 418 60 15 25 315 OFFICE 9046 1 20 63 1260 STORAGE / CORRIDORS 1310 N/A N/A 0.05 0 10 BREAK ROOM 311 5 20 2 40 TOTAL 11,211 11 1,145 r i !I diez architecture, inc. 5001 sw 74th court suite 105 miami, florida 33155 phone:. (305) 663 -1970 fax: (305) 663 -2312 II e-mail: peter®diezarchitecture.com pedro diez, ra president or 0008996 i ENGINEERING CONSULTANT PRV ENGINEERING, INC. Mechanical!- Electrical - Plumbing - Fire Protection 6452 NW 77 Gt. MwrN, FL 33taa - Ph: 305.959.8827 - Fx: 305.858.5955 Board of Professional EnaineNm Authorization No.: 00009M ( Mechanical Ent 111 P1 "rt Valdes, PE PE 31328 A e I Electrical ear • ROWrtarV9nereo, PE PE 32078 PR C AChi tk+r•••D it �,dfl1 INV G 4 f 6141 Sunset 5141' SOUT PROJEI REVISIC SUNSET DRIVE i MIAMI, FLORIDA S No. 03 -115 �I SCHEDULES DETAILS LEGEND ANIJ NOTES SCALE: A5 NOTED DATE: 1 1 �- 14 -05 1000