Loading...
05-1856-007I DOUR FIRE RATED WALL ASSEMBLY REFER TO WALL TYPE FOR ADDITIONAL INFORMATION FILL MATERIAL TO 8 FORCED INTO ANNUL TO MAXIMUM EXTENC POSSIBLE PENETRATION AS LISTED BELOW 1/4' TO 1/2' LARSER THAN OUTSIDE DIAM OF PENETRANT FILL MATERIAL A MINIMUM 1/2' CROWN TO FORM AROUND PENETRATING ITEM AND LAPPING 1/4' BEYOND PERIPHERY zy1LK VT _ 1- PENETRANT TYPE ( ONE OF THE FOLLOWING) A STEEL PIPE NOMINAL 12' DIA OF SMALLER SCHEDULED OR HEAVIER B. CONDUIT NOMINAL 6' DIA OR SMALLER EMT OR STEEL CONDUIT C. COPPER TUBING NOMINAL 6' DIA OR SMALLER TYPE L OR HEAVIER D. COPPER TUBING NOMINAL 6' DIA OR SMALLER REGULAR OR HEAVIER 2- FIRESTOP SYSTEM HILTI CONSTRUCTION CHEMICALS INC. TYPE FS 605 OR FS ONE SEALANT A 1 HR FIRE RATING UL DESIGN NO: W -L- 1085 rED r REFER =0R ADDITIONAL I_1 `,LANT TO COMPLETELY FILL - IULAR SPACE BETWEEN THE E AND GYPSUM BOARD iEMBLY J 3/4, MAX 11/4' 'PE AS LISTED SECTION A -A 1- PENETRANT TYPE ( ONE OF THE FOLLOWING) A NON METALLIC PIPE, POLY VINYL. CLORIDE (PVC) NOM 2' DIA OR SMALLER 2- FIRESTOP SYSTEM HILTI CONSTRUCTION CHEMICALS INC. TYPE FS 611A OR FS ONE SEALANT C 1 HR FIRE RATING UL DESIGN NO: W -L -2098 A – " –` – 4TED WALL ASSEMBLY ALL TYPE FOR ADDITIONAL N TYPE A LISTED BELOW y N �rL TYPICAL >S IN WW THIGICNE55 OP f.__ ....._, _..._ APPLIED WITH THE ANNULUS, FLUSH WITH BOTH SURFACES OF WALL SECTION A -A ' 1. PENETRANT TYPE CONE OR MORE NOMINAL 1' DIA) A STEEL ELECTRIC TUBING MINIMUM 1/2' MAX 1' CONDUIT RIGIDLY SUPPORTED ON BOTH SIDES OF WALL 2. FIRESTOP SYSTEM HILT[ CONSTRUCTION CHEMICALS INC. TYPE FS ONE SEALANT A4--] B 1 HR FIRE RATING 3° UL DESIGN NOS W -L -1095 1/2' MIN THICKNESS APPLIED WITHIN ANNULUS FLUSH WITH BOTH SIDES OF WALL SEALANT AND PACKING MATERIAL MIN 3' THK OF 5 PCF MINERAL WOOD BATT FOR PIPES 4' SMALLER 12' MAX DIA OF OPENING ANNULAR SPACE SHALL BE O AT THE POINT OF CONTACT TO A MAX OF 11/4' OF OUTSIDE DIAMETER OF PENETRANT I H S' CMU ASSEMBLY I HOUR RATED REFER TO WALL TYPES AND LIFE SAFETY PLANS FOR ADDITIONAL INFORMATION SECTION A -A I- PENETRANT TYPE ( ONE OF THE FOLLOWING) A STEEL PIPE NOMINAL 10' DIA OF SMALLER SCHEDULED OR HEAVIER B. CONDUIT NOMINAL 4' DIA OR SMALLER EMT OR STEEL CONDUIT C. COPPER TUBING NOMINAL 4' DIA OR SMALLER TYPE L OR HEAVIER D. COPPER TUBING NOMINAL 4' DIA OR SMALLER REGULAR OR HEAVIER 2- FIRESTOP SYSTEM HILTI CONSTRUCTION CHEMICALS INC. TYPE FS 601 / OR FS 604 / FS ONE SEALANT 1 HR FIRE RATING IHR FIRE RATED WALL ASSEMBLY REFER TO WALL TYPE NON -RATED WALL ASSEMBLY REFER TO WALL TYPE 1 HR FIRE RATED PARTITION UL DESIGN NOS C -AJ -1149 � )JOINT DETAIL 0 i GENERAL NOTES I. ALL THROUGH PENETRATIONS SHOWN ABOVE ARE BASED UPON SPECIFIC PRODUCTS AND MANUFACTURERS. FOR OTHER ACCEPTABLE MANUFACTURER'S REFER TO PROJECT SPECIFICATIONS. 2. ALL ASSEMBLIES SHOWN ABOVE ARE REPRESENTATIVE ONLY FOR COMPLETE CONSTRUCTION REQUIREMENT. REFER TO EACH ASSEMBLY NUMBER IN THE 'UL' MANUAL, VOLUME 2, M1513 EDITION. 3. FOR OTHER APPLICABLE REQUIREMENTS REFER TO PROJECT SPECIFICATIONS. 4. FOR FIRE RATED WALL ASSEMBLY TYPES BEARING UL LABLE REFER TO PARTITION TYPES. L; a r %c.- Kit o , f inc. 7430 sw 48th street miami, florida 33155 phone: (305) 663 -1970 fax: (305) 663 -2312 peter®diezarchitecture.com pedro diez, ra president ar 0008996 ENGINEERING CONSULTANT G141 Office Building 3rd Floor 6141 SUNSET DRIVE SOUTH MIAMI. FLORIDA PROJECT No. 04- 158.03 REVISIONS FIRE PENETRATION DETAILS A6.0 SCALE: AS SHOWN DATE: NOVEMBER 2, 2005 A6.0