05-1856-006i
BOTTOM OF EXISTING
STRUCTURE
BRACE PARTITIONS
e4' -0'OC
EXTEND PARTITION —
A MIN. OF 6' ABOVE THE
CEILING LINE (TYP)
CARPET OR VINYL BASE
CONCRETE BLOCK WALL FURRING DETAIL 1-- 1/2"
w -i
BOTTOM OF EXISTING
STRUCTURE
NEW 2' X 2' SUSPENDED ACOUSTICAL
CEILING ON A WHITE 15/16' GRID.
25 GA 5 5/8" METAL STUDS
24" O.G. W/ 5/8" GYP. BOARD
EACH SIDE. PROVIDE INSULATION
WHERE GALLED FOR IN PLANS.
PAINT W/ SEMI GLO55 PAINT.
COLOR SELECTED BY TENANT.
3 5/8' METAL TRACK ANCHORED
TO CONCRETE FLOOR SLAB
WITH 1/4' TAPCON, SPACED 24' OC MAX.
EXISTING CONCRETE SLAB
TYPICAL PARTITION DETAIL
P -1
Zb
1 1/21m
0
FIRE `- BOTTOM OF EXISTING STRUCTURE
CAULK zl-� �� H I \
ALL AROUND PARTITION TO BE TIGHT TO
BOTTOM OF STRUCTURE. ABOVE
PROVIDE A STENCILLED SIGN AT 15' -0'
O.C. ABOVE CEILIW -% STATING 'FIRE AND
SMOKE BARRIER PROTECT ALL
OPENMGS'. I' LETTERS ALONG FIRE
RATED PARTITIONS.
ANY PENETRATIONS TO THIS
PARTITION TO BE FIRE CAULKED
NEW 2' X 2' SUSPENDED ACOUSTICAL
CEILING, ON A WHITE 15/16' GRID.
I HR FIRE RATED PARTITION 5 5/5":26, GA
METAL STUDS ® 24" O.G. W/ ONE FULL
LENGHT LAYER OF 5/8" TYPE "x" GYP. BD.
APPLIED VERTICALLY WITH I" LONG #6
DRYWALL 50REW5 TO EACH SIDE. SCREWS
ARE 8" O.G. o PERIMETER AND 12" O.G. AT
THE INTERMEDIATE STUDS.
UL #465
GYP. BD TO BE 1 -'A L .
TAPED, SPACKLED, 4' SOUND BATTS DEMISING
SANDED, t PAINTED. , PARTITION
COLOR SELECTED BY
TENANT
CARPET OR VINYL
BASE ATTACH BOTTOM RUNNER TO SLAB
WITH 1/4' TAPCONS, SPACED 24' OC MAX
EXISTING CONCRETE
SLAB
I
A
BOTTOM OF EXISTING STRUCTURE
COMPOUND 9 . ' I
ALL AROUND PARTITION TO BE TIGHT TO
BOTTOM OF STRUCTURE. ABOVE
NEW 2' X 2' SUSPENDED ACOUSTICAL
CEILING, ON A WHITE 15116' GRID.
25 GA 5 5/8" (MIN.) METAL STUDS
® 24" O.G. W/ 5/8" GYP. BOARD
EACH SIDE TIGHT TO BOTTOM OF
STRUCTURE ABOVE. PROVIDE
INSULATION TO BOTTOM OF
STRUCTURE ABOVE. PAINT W/ SEMI
GLOSS PAINT. COLOR SELECTED
BY TENANT.
4" SOUND BATTS TO BOTTOM
OF STRUCTURE ABOVE
GYP. BD TO BE
TAPED, SPACKLED,
SANDED, t PAINTED.
COLOR SELECTED BY
TENANT
CARPET OR VINYL
BASE MIN, 3 5/8' METAL TRACK ANCHORED
TO CONCRETE FLOOR SLAB WITH
1/4' TAPCON, SPACED 24' OC MAX.
EXISTING CONCRETE
SLAB
FIRE RATED PARTITION 11/2" TYPICAL PARTITION DETAIL 1 U2'
P -2
P -5
diez
arch ate r ,
0
inc.
7430 sw 48th
street
miami, florida
33155
phone: (305)
663 -1970
fax: (305)
663 -2312
peter®diezarchitecture.com
pedro diez, ra
president ar
0008996
ENGINEERING CONSULTANT
G141
Office Building
3rd Floor
6141 SUNSET DRIVE
SOUTH MIAMI, FLORIDA
PROJECT No. 04- 158.03
REVISIONS
WALL DETAILS
lot
A • 111 ''
SCALE: AS SHOMJ '
DATE: NOVEMBER 2, 2005
A5.0
i
i -