Loading...
05-1856-002SW 61 AVE SW 61 CT *I SITE PLAN 1:30 L LEGAL DESCRIPTION I PROJECT DATA I GENERAL NOTES n N Z co CONSTRUCTION NOTES SCOPE OF WORK WORK CONSISTS OF THE INTERIOR BUILD OUT THE EXISTING VACANT SPACE, INCLUDED IN WORK ARE ELECTRICAL, PLUMBING, HVAC DUCTWORK, FLOORING, CEILING, PARTITIONS AND PAINTING. SEE PLANS FOR EXTENT. 7430 sw 48th street I. CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS AND SHALL 1. LOCATE EXIST SANITARY SEWER AND EXTEND AS REQUIRED FOR NEW LOTS 8 THROUGH 15, BLOCK 2, LESS THE SOUTH 21 FEET FOR RIGHT OF WAY ZONING DISTRICT MU -4 / MU -5 NOTIFY THE ARCHITECT IF ANY DISCREPANCIES ARE DISCOVERED BEFORE SERVICES. DEDICATION OF SW 12 ST, LARKIN CENTER ACCORDING TO THE PLAT THEREOF, AS pedro diez, ra PROCEEDING WITH THE WORK 2. GENERAL CONTRACTOR SHALL PROVIDE ALL SHORING AND TEMPORARY RECORDED IN PLAT BOOK 21, PAGE 61. AND LOT 5, BLOCK 2, ROSSWOOD SAFEGUARDS, DUST BARRIERS AND WARNING SIGNS AS REQUIRED. ACCORDING TO THE PLAT THEREOF, AS RECORDED IN PLAT BOOK 13, PAGE 62. SITE AREA 30,964 SF 2.- CONTRACTOR TO ACQUIRE ALL REQUIRED PERMITS FOR THE CONSTRUCTION 3. GENERAL CONTRACTOR SHALL NOTIFY OWNER/ BLDG. MANAGER IN WRITING BUILDING AREA AND SUBSEQUENT OCCUPANCY OF PROJECT. THREE DAYS PRIOR TO MAJOR ELECTRICAL OR MECHANICAL SHUTDOWN 3.- ALL WORK DONE UNDER THE SUPERVISION OF THE CONTRACTOR SHALL BE DONE t REQUIRED DOWNTIME SO THAT APPROPRIATE ACTION CAN BE TAKEN. EXISTING GROUND FLOOR 9,121 SF IN A NEAT AND WORKMAN -LIKE MANNER AND IN ACCORDANCE WITH ALL GOVERNING 4. CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS t SHALL EXISTING SECOND FLOOR 494 SF AGENCIES, RULES AND REGULATIONS HAVING JURISDICTION. NOTIFY THE ARCHITECT IN WRITING OF ANY DISCREPANCIES. EXISTING THIRD FLOOR 11,181 SF 4._ CONTRACTOR TO PROVIDE ALL SUPPLEMENTARY MATERIALS REQUIRED TO INSTALL, 5. ACTUAL EXISTING DIMENSIONS SHALL GOVERN. EXISTING FOURTH FLOOR 11,164 SF SUPPORT, BRACE AND SHORE ALL BUILDING COMPONENTS. 6. ALL DEBRIS TO BE DISPOSED OF BY CONTRACTOR - EXISTING FIFTH FLOOR 10342 SF 10,342 5.- PRIOR TO COMMENCING WORK, THE CONTRACTOR SHALL VERIFY THE LOCATION TOTAL SF OF ALL EQUIPMENT AND UTILITIES TO BE REMOVED OFF STREET PARKING REQUIRED 129 SPACES REMOVALS SHALL BE COORDINATED WITH THE OWNER AND ALL BUILDING AUTHORITIES HAVING JURISDICTION EXISTING OFF STREET PARKING PROVIDED 134 SPACES 6.- CONTRACTOR SHALL PROVIDE THE ARCHITECT WITH RED -LINED EXISTING BUILDING DATA EXISTING ON STREET PARKING PROVIDED 1 SPACES AS BUILT DRAWINGS FOR ANY AND ALL FIELD CHANGES AND/ OR ADDITIONS TO THE WORK INCLUDED IN THE DRAWINGS. AREA OF WORK I.- IF ANY CHANGES AND /OR DEVIATIONS ARE MADE TO THESE PLANS WITHOUT THE WRITTEN AUTHORIZATION OF THE ARCHITECT, THE CONTRACTOR SHALL THIRD FLOOR 11,181 SF BEAR FULL RESPONSIBILITY FOR SUCH CHANGES AND/ OR DEVIATIONS. 5 STORY CBS BLDG WITH CONCRETE JOIST FLOOR AND ROOF STRUCTURE AND 8.- IF DURING THE COURSE OF CONSTRUCTION ANY DEVIATIONS ARE MADE CONCRETE INTERIOR COLUMNS. AT THE FIELD, AGAIN, THE CONTRACTOR SHALL BEAR FULL RESPONSIBILITY BLDG TYPE - TYPE III I HR PROTECTED W/ FULLY AUTOMATIC FIRE SPRINKLER SYSTEM THROUGHOUT ENTIRE BLDG FOR SUCH CHANGES AND / OR DEVIATIONS. ACCESIBILITY NOTES 9.- ALL SHOP DRAWINGS SHALL BE SUBMITTED TO THE ARCHITECT FOR FIRE RESISTANCE RATING- 1 HR FIRE RATING FOR STRUCTURAL ELEMENTS t FLOORS AND DESIGN CONFORMANCE ONLY 2 HR FIRE PROTECTION FOR EXTERIOR WALLS AS PER FBC 2004 TABLE 601. 10.- SUBSTITUTIONS MUST BE REVIEWED AND APPROVED BY THE ARCHITECT OR ENGINEERS 1. RESULTS OF THIS RENOVATION WILL NOT CREATE ANY OFFICES TO HAVE A FIRE ALARM SYSTEM AND AN AUTOMATIC FIRE SUPRESSION SYSTEM. ARCHITECTURAL BARRIERS (4.1614.18 FA.C). 11.- CONTRACTOR AND SUBCONTRACTORS SHALL BE RESPONSIBLE FOR CLEANING HIS OR HER 2. ALL LEVELS ARE ACCESSIBLE OPERATION AND REPAIRING ANY DAMAGE TO HIS WORK WHILE PROJECT IS UNDER 3. ALL NEW DOORS ARE 2' -10' WIDE MIN, 32' CLEAR OPENING, UNDER CONSTRUCTION 4. COMMON PATH OF TRAVEL, MAXIMUM LEVEL 12.- ALL WORK SHALL BE PERFORMED TO MEET AND COMPLY WITH A.D.A. DIFFERENCE 1/2' STANDARDS AND 2004 F.B.G. CHAPTER 11, F.A.C. 13.- ALL DESIGNS AND DRAWINGS HERE IN AND PRINTS ISSUED BY THE ARCHITECT ARE THE PROPERTY OF THE ARCHITECT AND SHALL NOT BE REUSED ON ANY OTHER LOCATION EXCEPT FOR THE ONE FOR WHICH THEY WERE EXPRESSLY DESIGNED . IF THESE DRAWINGS OR ANY PART THERE OF IS REPRODUCED WITHOUT THE CONSENT OF THE ARCHITECT, THE PERSON SO DOING WILL BE INDEBTED TO THE ARCHITECT FOR HIS FULL COMMISSION SCOPE OF WORK WORK CONSISTS OF THE INTERIOR BUILD OUT THE EXISTING VACANT SPACE, INCLUDED IN WORK ARE ELECTRICAL, PLUMBING, HVAC DUCTWORK, FLOORING, CEILING, PARTITIONS AND PAINTING. SEE PLANS FOR EXTENT. 7430 sw 48th street miami, florida 33155 phone: (305) 663 -1970 fax: (305) 663 -2312 peter0diezarchitecture.com pedro diez, ra president ar 0008996 ENGINEERING CONSULTANT G141 Office Building 3rd Floor 6141 SUNSET DRIVE SOUTH MIAMI, FLORIDA PROJECT No. 04- 158.03 REVISIONS SITE PLAN �I �n SCALE: AS SHOWN DATE: NOVEMBER 2, 2005 A1.0