Loading...
97-498-113o~ PLAN NOTES: e`'o� 'i •7 a MOUNT THIS BOARD 6" BELOW CEILING TO TOP AND 361, RIGHT OF PROJECTION PORT CENTERLINE' TO CENTERLINE Q CONSOLE POWER- 6"x6'x6" Box WITH SCREW COVER- 12 _ '� •� .. 120/208V0LT, 3PHASE SWIRE ISOLATED GROUND CIRCUIT _ O O FROM BOOTH POWER : PANEL, #BWIRE. LEAVE 1' -0" LOOSE 00 - ' - 2 MOUNT 6' -0" -A.F.F. AND 36" RIGHT OF CENTERLINE WIRE AT BOX. VV IT + + HI !� 1/2n CONDUIT TO , 4'x4" BOX; W/SLANK COVER PLATE AND SINGLE 5 12 GANG PLASTER RINGS. LOCATED ON AUDITORIUM SIDEWALL. MOUNT BOX 6' -0" A.F.F.. AT LOCATION INDICATED. - FUTURE REMOTE FOCUS. ' MID + TRI- TRI- + MID ■ LEFT BLU AMP ■ AMP BLU RIGHT ■ 3� AUTOWIND= ' DUPLEX RECEPTACLE 120V0LT, 20AMP, #12WIRE �/� O O O O 1 1- ONLY ONLY - 5 5 O O O' O CIRCUIT TO EACH FROM BOOTH POWER PANEL OW + + RED Q 2 RECEPTACLE- DUPLEX RECEPTACLE, 120V0LT, (BLK) FEED COM HI + + HI 12WIRE CIRCUIT FROM BOOTH POWER PANEL 1 - - 5 WHT WHT MAX. 3 PER CIRCUIT. - REW N S , _ _ Gould'. ( / HI + + HI S Q 6"x6"x6" HINGED WIREWAY- 5 -tT LONG. AUTO (GRN) FLAT WHT_ MID + TRI- TRI- MID ■ ■ SOUND ■ 2 - - 4 ■ LEFT BLU _ AMP ■ AMP LUE RIGHT■ 66 SOUND AMPLIFIER POWER- fx4!xC BOX WITH SCREW COVER. MASKING (BRN) SCOPE E A FORMAT 1 1 - ONLY ONLY - 5 5 (1) 120V0LT, . 60AMP.. #6WtRE do 1 #8WIRE ISOLATED GROUND, _ LEFT MID + TRI- TRI- +' MID RIGHT DEDICATED SEPARATE NEUTRAL CIRCUIT. LEAVE 1' -0" LOOSE SR - ■ CENTER B2 E - ONLY ■ ONLY _ BLUE CENTER ■ Evcms (RED) COM. RE + + LOW WIRE AT BOX. (BLU) FLAT DIGIT 1 - - 5 . (ORN) RE + + LO 7 TERMINAL BOX AUTOMATION. SEE DETAIL - TYPICAL ALL Mg FUTUR 2 _ - R4D HI + + HI AUDITORIUMS. #INDICATES AUDITORIUM NUMBER. (ORC) (STRONG) O O O O �.' �` O O O O W2 - - W4 CONTRACTOR TO MAKE ALL TERMINATIONS. - (WHT) 1 CON LEFT MID + TRI- TRI- + MID RIGHT Aa TERMINAL BOX AUDIO. SEE DETAIL - TYPICAL ALL &wiatesLC ALARM/ HI + SUB + ■CTR. BLU AMP ■ AMP WE CTR. ■ AUDITORIUMS. # INDICATES AUDITORIUM NUMBER. �. STATUS (GRN) 2 Scm WHT _ LINE _ . SUB 1 2 2 - ONLY ONLY - 4 4 CONTRACTOR TO MAKE ALL TERMINATIONS. NOT ■ COM (RED) 4 ■ 9 2 DIMMER ■ SIGNAL LOW + +LAW REMOTE ALARM STATUS PANELS (30 REQUIRED AT 10 LOCATIONS), FURNISHED USED MID + TRI- SHIELD R RED BY OWNER. 'INSTALLED AND CONNECTED BY ELECTRICAL. CONTRACTOR. HOT (BL.K) 5 Sm CENTER BLUE AMP 2 - - 4 3 3 - ONLY SUB + hillissadwseft �► 1/2" CONDUIT WITH (1) BELDON #9841 -2 CONDUCTOR SHIELDED CABLE 7� •- (BRN) 6 Std 4 ■ LOW + LINE _ SUB 2 O O 0 O COLOR CODED. MAKE CONNECTIONS AT ALL ALARM STATUS PANELS AND 1AWrme KS 66Q44_2256 • 0 0 0 0 3 _ ■ SHIELD SIGNAL ■ WHI + SUB- + 1 AUTOMATION TERMINAL BOARDS. SEE DETAIL SHEET E19, 913/842 3800 FIRE 1 1 DOOR •� 3 - LINE - A NOT USED. 913/842 3830 fax ALARM RELEASE SPARE + o o + SUB 3 _ i0 GOlt� ■ 2 ■ 2 ■ a Z a = _ LINE ■CT• MID RIP ■ SHIELD SUBS ■ N 12GA - Z Z FAIL 3 3 SPARE o m 0 w 3 3- ONLY SUB + 2 SIGNAL SAFE SPARE + a � a � + SUB 4 2 10 NOT USED. 4 4 10GA- 0 ion .0 cn LINE LOW + LINE - O O 00 (ORC) (STRONG) O O O O 3- SHIELD r SPARE 1 1 BL.K SHIELD + + ' ® NOT USED. � ■ 2 2 (RED DATA GND ORG + + GRY PHONE - - 3 SUBS ■ (RED) ■ SUR. - - SUR. 3 3 (WHT) DATA - SYNC. ■ LEFT ORG + ■ + GRY RIGHT ■ ■ SHIELD + 4 LINE ® NOT USED. 4 4 (GRN) DATA + 2 _ _ 2 - SPA2RE ■ - FUTURE + GA SPARE + 5 5 (BRN) ORG + + GRY 10 AUX. 11 GRAFIX EYE DIMMER CONTROL MODULE AND AV INTERFACE. f ' 6 6 (BLU) 3--m - - 3 SHIELD GA - MOUNT 4' -0" A.F.F. RIGHT OF VIEW PORT AS INDICATED. O O O O TYPICAL ALL AUDITORIUMS, SEE DETAIL j O O 00 ORG + + GRY A 3/4" CONDUIT WITH 2 #12 do 1 BELDON #9461 SHIELDED ` 4 4 CABLE. MAKE CONNECTION IN DIMMER CABINET AND AT ■- STRAIN REUEF CABLE TIE CUPS BOX- 12"x15' ORANGE ORG + + GRY GREY GRAFIX EYE CONTROL MODULE. (SEE DETAIL THIS SHEET). S 5 t® 1/t CONDUIT TO TERMINAL BOX AUTOMATION WITH 5#12. BOOTH, - - MAKE CONNECTIONS TO AV INTERFACE AND TERMINAL STRIP IN TERMINAL BOX AUTOMATION. ■ ORG + ■ + GRYI ■ t2 SCREEN WALL SPEAKERS- 8 CHANNEL TRI -AMP (1,2.3,4,5 E TERMINAL BOARD AUTOMATION - - &SPARE) (18 PAIR) VAMPIRE COLOR CODED 12GA CABLES. ALL unja j IN 2" CONDUIT TO TERMINAL BOARD AUDIO /SCREENWALL (ROUTE PURCHASE FR -0 M SOUND CONNECTIONS I NT' L, INC. 0 0 0 0 OVERHEAD). MAKE CONNECTION IN TERMINAL BOXES AT BOTH ENDS. ■ - STRAIN RELIEF CABLE TIE CUPS SEE DETAILS- TYPICAL ALL AUDITORIUMS. ELECTRICAL CONTRACTOR (813) 948 -2707 — STUART MARCUS Aux. A + + B AUX• SHALL INSTALL TAPE MARKER IN EACH CONDUIT TO DETERMINE ac� < t SCREEN WALL LENGTHS OF CABLE. PURCHASE FROM SOUND CONNECTIONS I „ � NOTES: ELECTRICAL CONTRACTOR SHALL MAKE ALL. TERMINATIONS ON THIS BOARD - - INT'L. INC. (813)' 948 -2707 - STUART MARCUS - � d r i ON OUTER TERMINALS. INNER TERMINAL CONNECTIONS BY OWNER. + + �011$jl `;my I. QSCREEN WALL SPEAKERS- 6 CHANNEL TRI -AMP (1.3.5,SUB1 PULL ALL CABLES MINIMUM 18• PAST BOTTOM OF PANEL BACKGROUND 1 - - IMPaRED 2 BOARD A SPAR 12 PAIR) VAMPIRE COLOR CODED 12GA. CABLES. ALL` IN 1 1 / ROUTE CABLES AROUND THE APPROPRIATE OUTER SIDES OF PANEL ■ SHIELD ■ SHIELD ■ CONDUIT TO TERMINAL BOARD AUDIO /SCREENWALL (ROUTE LI OVERHE!DL.(� AKE CONNECTION IN • + + , SEE DETTYPICAL ALL AUDITORIUMS., ELECTRICAL CONTRACTOR ; , `, TRIM TO LENGTH, STRIP 1 /4 , AND CRIMP ON BARRIER SPADE CONNECTOR P U R C HAS E FR 0 M S 0 U N D C 0 N N ECTI O N S I NT L, I N C . SHALL INSTALL TAPE MARKER IN EACH CONDUIT TO DETERMINE ; TO CABLE. ' FUTURE 2 _ _ MICROPHONE (813) 948 -2707 — STUART MARCUS LENGTHS OF CABLE. PURCHASE FROM SOUND CONNECTIONS INT'L.. INC. (813) 948 -2707 - STUART MARCUS ; BARRIER SPADE CONNECTORS ARE FURNISHED WITH TERMINAL BOARD. ` SHIELD SHI NOTES: ELECTRICAL CONTRACTOR SHALL MAKE ALL TERMINATIONS ON THIS BOARD O O O O UTILIZING OUTER TERMINALS. INNER TERMINAL CONNECTIONS BY OWNER. SCREEN WALL SPEAKERS- 6 CHANNEL BI -AMP (1.3.5,SUB1 ; do SPARK (9 PAIR) VAMPIRE COLOR CODED 12GA. CABLES. ALL ILI PULL ALL CABLES 18" PAST BOTTOM OF PANEL IN 1 1/T CONDUIT TO TERMINAL BOARD AUDIO /SCREENWALL. (ROUTE , ■ - STRAIN RELIEF CABLE TIE CUPS BOX- 12"x24" OVERHEAD). MAKE CONNECTION IN TERMINAL BOXES AT BOTH ENDS. ROUTE CABLES AROUND THE APPROPRIATE OUTER SIDES OF PANEL SEE DETAILS - TYPICAL ALL AUDITORIUMS. ELECTRICAL CONTRACTOR SHALL INSTALL TAPE MARKER IN EACH CONDUIT TO DETERMINE TRIM TO LENGTH, STRIP 1/4% AND CRIMP ON BARRIER SPADE CONNECTOR LENGTHS OF CABLE. PURCHASE FROM SOUND CONNECTIONS ~ BOOTH TO CABLE. INrL. INC. (813) 948 -2707 - STUART MARCUS ., r 8 BARRIER SPADE CONNECTORS ARE FURNISHED WITH TERMINAL BOARD. t3 4 -PLEX ISOLATED GROUND RECEPTACLE. MOUNT IN BACKGROUND TERMINAL BOARD A MUSIC RACK THIS LOCATION FOR BACKGROUND MUSIC EQUIPMENT WITH ISOLATED GROUND. w PURCHASE FROM SOUND CONNECTIONS INT'L, INC. Z A 1/f CONDUIT WITH (1) BELDEN #8770 TO J -BOX AT (813) 948-2707 STUART MARCUS tt BACKGROUND MUSIC SOURCE LOCATION- BOOTH WALL AT NOTES: ELECTRICAL CONTRACTOR SHALL MAKE ALL TERMINATIONS ON THIS BOARD AUD. #13. MAKE CONNECTIONS IN AUDIO TERMINAL BOARD O UTILIZING OUTER TERMINALS. INNER TERMINAL CONNECTIONS BY OWNER. AND BACKGROUND MUSIC RACK THIS LOCATION. PULL ALL CABLES MINIMUM 18" PAST BOTTOM OF PANEL. t4 1/2" CONDUIT WITH 7 #18 TO AUTO MASKING J -BOX AT DAISEY CHAIN SCREEN WALL BELDEN #8467 CABLE. MAKE ALL TERMINATIONS. a ROUTE CABLES AROUND THE APPROPRIATE OUTER SIDES OF PANEL TO OTHER CO TROL ERS TYPICAL, t5 SURROUND SOUND WIRING RIGHT AND LEFT. ONE VAMPIRE 12GA r� TRIM TO LENGTH, STRIP 1/4% AND CRIMP ON BARRIER SPADE CONNECTOR DIMMER LUTRON CABLE TO EACH SPEAKER, TO CABLE. DIMMING Q J -BOX ON WALL ABOVE CEILING 6" MAX. ABOVE CEILING LINE) BARRIER SPADE CONNECTORS ARE FURNISHED WITH TERMINAL BOARD. CABINET Z / FOR SURROUND SOUND 'CABLE. 1 12GA. CABLE. 2# 2 C. 1V/ LEAVE 10' -0" OF FLEX 1/2' CONDUIT WITH CABLE FOR i • BELDEN # SEE PLANS CONNECTION TO SPEAKER. L 9461 SHIELDED FOR QUANTITIES t6 LIGHT FIXTURE- 120V0LT WALL MOUNTED E 'S'- SEE . CABLE. TYPICAL AND LOCATIONS �' EACH AUDITORIUM SCHEDULE). MOUNT 7' -0" A.F.F. IN LOCATIONS INDICATED. w 5#12 TO TERMINAL t7 DIMMERS - 1 DIMMER FOR AISLE LIGHTS PROVIDED BY AMC, 1 LABELED DIMMER CONTRACTOR INSTALLED. 1 DIMMER FOR RISER' UGHTS PROVIDED AND INSTALLED BY TO TB AUTO ELECTRICAL CONTRACTOR- LUTRON #DVF- 103P -BL WITH PRESET. EACH AUDITORIUM 1 SWITCH FOR -TYPE 'S' FIXTURE PROVIDED AND INSTALLED BY CONTRATOR GRX -AV INTERFACE MOUNTED 18 AISLE LIGHTS TRANSFORMERS SUPPLIED BY OWNER, INSTALLED ABOVE EACH CONTROLLER BY ELECTRICAL CONTRACTOR. t tt 19 ELECTRONIC LOW VOLTAGE DIMMER INTERFACE PROVIDED AND INSTALLED BY { GRAFIX- EYE #4104 SCENE ELECTRICAL CONTRACTOR., LUTRON #ELV1 -1000. MOUNT IN Cx C BOX CONTROLLER LOCATED RIGHT WITH EXTENDER FOR 3 1/t DEPTH. SIDE, EACH VIEW PORT Q CEILING FAN CONTROLLERS. INSTALLED BY ELECTRICAL CONTRACTOR. SEE SPECIFICATIONS. � TYPICAL DIMMER CONTROL WIRING O ' 2t TO RELAY IN FIRE ALARM CONTROL PANEL., 4 #16. j NO SCALE GENERAL NOTES 1. ALL CONDUIT, BOXES. PANELS, ETC. ARE TO BE SURFACE MOUNTED ON BOOTH WALLS. NOTE: CONTRACTOR MAY ROUTE CONDUITS 2. ALL WIRING #14 GAUGE AND SMALLER SHALL BE STRANDED COPPER WITH 600 VOLT • VERTICALLY IN THIS AREA TO ABOVE INSULATION RATING EXCEPT SOUND CABLE. I TO CEILING FANS 8' -0" A.F.F.. THEN TO CORRESPONDING BOOTH PANEL IN STRUCTURAL SPACE 3. ALL POWER WIRING . TO BE FED FROM APPROPRIATE BOOTH POWER PANEL (TYPICAL ALL AUDITORIUMS) 4. ALL WIRING TO BE IN ACCORDANCE WITH BUILDING SPECIFICATIONS, LOCAL CODES AND MANUAL STARTER ORDINANCES. 1 W /PILOT LIGHT FOR EF -10 PROJECTOR EXHAUST 5. SEE ARCHITECTURAL DRAWINGS FOR EXACT LOCATION ,OF PROJECTION, VIEW AND SLIDE FAN (LABEL AUD. TO PROJECTION PORTS. CEILING #1 #12) FANS 6. ALL WIRING SHALL BE INSTALLED IN RIGID CONDUIT OR ELECTRICAL METALLIC TUBING j \ 7. ALL EQUIPMENT AND WIRING IN PROJECTION BOOTHS COMPLY WITH N.E.C. SECTION A c� Naee j 16 ( 18 540 -11(b) EXCEPTION NO. 2. K� KS I MO t9 t \ 8. ,NO CONDUIT OR CABLE PENETRATIONS WILL BE ALLOWED THROUGH =FL P� TB1 P� DIMMER \ M2 AUDITORIUM DEMISING WALLS. AZ 'BPK #1 \ j 1 - -- — _ No. Revi�on Date PR)j i X \ f I Q oo \� i B oo i f PO�iT I It. r I I P� I 11 S �) #' ' 1 ' o 0 AISLE LIGHT j + AUDI tf2 TB1 I 4 4 I TRANSFORMERS i I — f' _._. TB2 - 3 UT 1 1 "C. 7 ( 1 4 1 "c• Dram GWJ Checked GJW f Project W. AMC r i \ 1 "C. -- ' � Date NOVEMBER 1996 i 5' -0" TYPE -z- (Typ) (TYPICAL) BOOTH ELEVATIONS PROJECTION -BOOTH AUD. #1 AND #2 SCALE: 3/8" a 1' -0~ E16